- 32
- 119 678
AK ElectroTech
Pakistan
เข้าร่วมเมื่อ 14 ม.ค. 2021
Guide to UPS Repairs
We repair different types of UPS including APC, PowerWare, Eaton, Liebert, etc. Mainly, our videos are focused on common faults of APC Online ups and how to fix them.
If you are in this field, then make sure to subscribe this channel as it will be helpful for you.
WhatsApp: +923215717132
We repair different types of UPS including APC, PowerWare, Eaton, Liebert, etc. Mainly, our videos are focused on common faults of APC Online ups and how to fix them.
If you are in this field, then make sure to subscribe this channel as it will be helpful for you.
WhatsApp: +923215717132
APC SURT 5KVA Dead SMPS power supply repaired
APC SURT 5KVA Dead SMPS power supply
In this video I am going to fix dead ups power supply
Common searches...
apc ups repair
online ups repair
ups not powering on
how to work ups smps
ups working principle
switch mode power supply ups repairing
apc dead ups
uninterruptible power supply
ups board repair
dead ups apc
power supply repair fault
#apc #ups #upsrepairing #apcups #akelectrotech #schneiderelectric
In this video I am going to fix dead ups power supply
Common searches...
apc ups repair
online ups repair
ups not powering on
how to work ups smps
ups working principle
switch mode power supply ups repairing
apc dead ups
uninterruptible power supply
ups board repair
dead ups apc
power supply repair fault
#apc #ups #upsrepairing #apcups #akelectrotech #schneiderelectric
มุมมอง: 1 208
วีดีโอ
Hp compaq elite 8300 sff upgrade | Hp Elite 8300 graphics card upgrade | Hp Elite 8300 ssd upgrade
มุมมอง 1.5K7 หลายเดือนก่อน
Hp compaq elite 8300 sff upgrade | Hp Elite 8300 graphics card upgrade | Hp Elite 8300 ssd upgrade Your Searches hp compaq elite 8300 gaming hp compaq elite 8300 sff hp elite 8300 gaming hp elite 8300 sff upgrade hp compaq elite 8300 upgrade hp compaq elite 8300 upgrade graphics card hp compaq elite 8300 ultra-slim pc upgrade hp elite 8300 sff hp compaq elite 8300 ssd upgrade hp compaq elite 83...
EUROSTAR 3KVA POTENZA Online UPS
มุมมอง 4698 หลายเดือนก่อน
#ups #ups repairing EUROSTAR 3KVA POTENZA Online UPS Common searches... ups repair online ups repair ups not powering on how to work on ups control card ups working principle computer ups repairing ups controller card repairing uninterruptible power supply ups board repair block diagram and configuration of ups potenza eurostar 3kva power supply repair eurostar ups eurostar potenza ups eurostar...
APC SRT 3KVA UPS Introduction
มุมมอง 1.1K8 หลายเดือนก่อน
#apc #ups #akelectrotech APC SRT 3KVA UPS Introduction Common searches... apc ups repair online ups repair ups not powering on how to work ups inverter ups working principle computer ups repairing uninterruptible power supply ups board repair block diagram and configuration of ups pfc power supply repair #apc #ups #upsrepairing #apcups #akelectrotech #schneiderelectric
Fixing APC SURTD UPS Bypass Fault | Troubleshooting & Repair Guide
มุมมอง 1.3K9 หลายเดือนก่อน
Fixing APC SURTD UPS Bypass Fault | Troubleshooting & Repair Guide Common searches... apc ups repair online ups repair ups not powering on how to work ups inverter ups working principle computer ups repairing apc ups software installation uninterruptible power supply ups board repair block diagram and configuration of ups pfc power supply repair #apc #ups #upsrepairing #apcups #akelectrotech #s...
How to Resolve -DC Soft Start Fault P.16 for APC SRT 5KVA UPS | Event Code 125
มุมมอง 1.8K10 หลายเดือนก่อน
#apc #ups How to Resolve APC SRT 5KVA Soft Start Fault P.16 | Step-by-Step Guide APC SRT 5KVA Soft Start Fault P.16 Fixing Error Solutions APC UPS Power supply APC Smart-UPS Technical issues Troubleshooting Power backup APC Support Electrical faults UPS maintenance Power management Electrical Maintenance Electrical troubleshooting Uninterruptible Power Supply DIY APC SRT 5KVA Soft Start repair ...
APC SRT 5KVA 02000 Inverter Hardware Ckt repaired
มุมมอง 4.1K10 หลายเดือนก่อน
#apc #ups #upsrepairing Apc Srt 5 Kva Ups Inverter Repair | Apc Ups Inverter Hardware Ckt | How to repair 02000 for Apc Ups NOTE: English subtitles are available for this video. The video language is urdu/hindi. If you don't understand this, then you can turn on the subtitles Your searches apc srt ups repair how to repair ups repair apc ups online ups repair ups repair apc ups 02000 error aps s...
APC SRT 3KVA UPS Firmware error solved
มุมมอง 1.3K11 หลายเดือนก่อน
#apc #ups #upsrepairing Apc Srt 3 Kva Ups firmware Repair | Apc Ups EEPROM Fault | How to repair software for Apc Ups NOTE: English subtitles are available for this video. The video language is urdu/hindi. If you don't understand this, then you can turn on the subtitles Your searches apc ups repair how to repair ups repair apc ups online ups repair ups repair apc ups aps srt 3000xli apc firmwar...
APC SRT 3KVA P.13 Inverter fault repaired
มุมมอง 4.4K11 หลายเดือนก่อน
#apc #ups #upsrepairing Apc Srt 3 Kva Ups Inverter Repair | Apc Ups Inverter Fault | How to repair inverter for Apc Ups NOTE: English subtitles are available for this video. The video language is urdu/hindi. If you don't understand this, then you can turn on the subtitles Your searches apc ups repair how to repair ups repair apc ups online ups repair ups repair apc ups aps surt 3000xli apc inve...
Liebert Emerson eXL-80NET 200KVA Inverter repair | Liebert 80-eXL 200KVA
มุมมอง 45511 หลายเดือนก่อน
Liebert Emerson eXL-80NET 200KVA Inverter repair | Liebert 80-eXL 200KVA In this detailed video, we delve into the intricacies of repairing the Liebert Emerson eXL-80NET 200KVA inverter, specifically focusing on the Liebert 80-eXL 200KVA model. If you've been encountering issues with your inverter system, whether it's malfunctions, error codes, or performance issues, you've come to the right pl...
APC SRV 2KVA Easy UPS introduction
มุมมอง 445ปีที่แล้ว
In this video i will tell you introduction of APC SRV 2KVA Easy UPS. NOTE: English subtitles are available for this video. The video language is urdu/hindi. If you don't understand this, then you can turn on the subtitles Your searches APC Repair APC Repair Complete Guide apc smart ups apc srv 2000va easy ups apc srv 2kva apc srv 2kva ups apc srv online ups apc srv ups apc ups apc ups apc ups i...
Powerware PW9120 700VA UPS Introduction
มุมมอง 343ปีที่แล้ว
#ups #introduction Powerware 9120 700VA UPS - Introduction Welcome to the Powerware PW9120 700VA UPS - Introduction! In this comprehensive video, we delve into the world of Powerware cutting-edge PW9120 Uninterruptible Power Supply (UPS) system. Whether you're a tech enthusiast, a small business owner, or an IT professional, this video provides an in-depth overview of the PW9120, highlighting i...
APC 10KVA SURT Inverter fault repairing troubleshooting (English Subtitles)
มุมมอง 3.2Kปีที่แล้ว
#apc #ups #upsrepairing Apc Surt 10 Kva Ups Inverter Repair | Apc Ups Inverter Fault | How to repair inverter for Apc Ups NOTE: English subtitles are available for this video. The video language is urdu/hindi. If you don't understand this, then you can turn on the subtitles Your searches apc ups repair how to repair ups repair apc ups online ups repair ups repair apc ups aps surt 10000xli apc i...
Powerware PW9120 3KVA UPS - Introduction
มุมมอง 741ปีที่แล้ว
#ups #introduction Powerware 9120 UPS - Introduction Welcome to the Powerware PW9120 UPS - Introduction! In this comprehensive video, we delve into the world of Powerware cutting-edge PW9120 Uninterruptible Power Supply (UPS) system. Whether you're a tech enthusiast, a small business owner, or an IT professional, this video provides an in-depth overview of the PW9120, highlighting its key featu...
APC SURTD UPS Software update | Online UPS software update tutorial
มุมมอง 1.4Kปีที่แล้ว
APC SURTD UPS Software update | Online UPS software update tutorial Welcome to AK ElectroTech! 🛠️ Learn how to update the software on your APC SURTD UPS with this quick and easy tutorial. Keeping your UPS software current ensures peak performance and reliability. 🔧 Steps Covered: Installing the software Update Configuring Settings Verifying the Update Troubleshooting Tips 🚀 Stay Powered Up: Opt...
Fix UPS APC: Repair Dead Power Supply | APC UPS not turning ON
มุมมอง 6Kปีที่แล้ว
Fix UPS APC: Repair Dead Power Supply | APC UPS not turning ON
IGBT Testing for Beginners | IGBT Testing Explained in Urdu | How to check IGBT
มุมมอง 655ปีที่แล้ว
IGBT Testing for Beginners | IGBT Testing Explained in Urdu | How to check IGBT
APC UPS Inverter Repair | How to troubleshoot inverter fault
มุมมอง 7Kปีที่แล้ว
APC UPS Inverter Repair | How to troubleshoot inverter fault
APC SURTD UPS Control Card Repair Guide: Step-by-Step Tutorial
มุมมอง 2.7Kปีที่แล้ว
APC SURTD UPS Control Card Repair Guide: Step-by-Step Tutorial
Troubleshooting APC UPS PFC Fault | Repair Guide
มุมมอง 8Kปีที่แล้ว
Troubleshooting APC UPS PFC Fault | Repair Guide
Apc Surt 10 Kva Ups Inverter Repair | Apc Ups Inverter Fault | How to repair inverter for Apc Ups
มุมมอง 2.9Kปีที่แล้ว
Apc Surt 10 Kva Ups Inverter Repair | Apc Ups Inverter Fault | How to repair inverter for Apc Ups
APC 10KVA ON OFF fault | APC SURT UPS ON Off Fault | APC 10KVA UPS Repairing
มุมมอง 2Kปีที่แล้ว
APC 10KVA ON OFF fault | APC SURT UPS ON Off Fault | APC 10KVA UPS Repairing
Hp compaq elite 8300 sff upgrade | Hp Elite 8300 graphics card upgrade | Nvidia Quadro p620 2 GB gpu
มุมมอง 3.7Kปีที่แล้ว
Hp compaq elite 8300 sff upgrade | Hp Elite 8300 graphics card upgrade | Nvidia Quadro p620 2 GB gpu
Hp compaq elite 8300 sff upgrade | Hp Elite 8300 graphics card upgrade | Hp Elite 8300 ssd upgrade
มุมมอง 30Kปีที่แล้ว
Hp compaq elite 8300 sff upgrade | Hp Elite 8300 graphics card upgrade | Hp Elite 8300 ssd upgrade
HP Elite 8300 sff PC TEARDOWN | hp elite 8300 disassembly
มุมมอง 16Kปีที่แล้ว
HP Elite 8300 sff PC TEARDOWN | hp elite 8300 disassembly
APC SRT 8KVA/10KVA UPS Introduction | Repairing guide
มุมมอง 2.1Kปีที่แล้ว
APC SRT 8KVA/10KVA UPS Introduction | Repairing guide
APC SURT UPS Fault Codes | All Diagnostic Codes
มุมมอง 8Kปีที่แล้ว
APC SURT UPS Fault Codes | All Diagnostic Codes
APC SURT 8KVA / 10KVA Online UPS and Details about its Board in English
มุมมอง 985ปีที่แล้ว
APC SURT 8KVA / 10KVA Online UPS and Details about its Board in English
APC SURT 8KVA / 10KVA Online UPS and Details about its Board in urdu
มุมมอง 631ปีที่แล้ว
APC SURT 8KVA / 10KVA Online UPS and Details about its Board in urdu
APC SURT 1KVA / 2KVA Online UPS and Details about its Board in Urdu
มุมมอง 1.8Kปีที่แล้ว
APC SURT 1KVA / 2KVA Online UPS and Details about its Board in Urdu
grate
Thanks
CAN WE CASE SWAP THIS PC??
Can i upgrade this PC for gaming? Thanks
HEY!! CAN YOU SUGGEST ME A CABINET TO SWAP THIS SMALL CABINET
Lvl
Thanks
Hi! My APC UPS has the code "Output Off Fault" on screen. Could that be similar to this?
Hi May be
Hello sir I am checking surt6kva having inverter fault on battery mode.Checked all power components without removed checked ok.Given 24v at capacitor.checked all optocouplers vcc to gnd 16.45v ok.Then trigger optocoupler using 3v battery at that time one optocoupler giving 13.9v remaining 13.6vdc.Another things I need to check
Hello You need to check battery relay or replace control card
Tegangan batree berapa volt?
@@ashari_cb 16 batteries are used and it is 12V x 16 batteries = 192V. Now charging voltage should be 13.5V charger x 16 batteries = 216V
sir last light on ha inverter ma kiya dekhien 10 kv
@@umairskhans-sw9cz Inverter portion, control card
great teach bro
@@umairskhans-sw9cz Thanks
Nvidia quadro p620 2gb gpu
Yes
i have another issue in my 1k UPS same brand , but its giving error " Red light on ( X ) with 2 lights in battery bar like ( 00110 ) i check the service manual i found this FAN Failure i changed all damaged components and i measured all resistors , capacitors "changed " , diods , all mosfets Checked , changed FAN and i changed 2 UC3845 IC's and regulator LM317 but still not working , i tried to change the control card i taked from another working UPS , but also not working Once in press Test both fan working then the back side stop again , can U please support me ??
Hello sir surtd3kva having high output voltage fault what i have to check give me an idea
@@ganeshm1735 Replace output capacitor
Output capacitor good I have tested with load for some time it was working but after sometime resistor near output capacitor getting heat some abnormal sound near the capacitor please give me an idea
@@ganeshm1735 Replace capacitor
HELLO .... TELL ME PLEASE IF YOU CAN HOW TO RESET OR CLEAR THE : FAULTY ERROR STATE ? AFTER REPAIR ,AND THEN OPERATE TESTING UPS .
@@giorg6959 Repair hardware issue showing in log history, and clear alarms
@AKElectroTech THANK YOU .
Aoa. Sir kia Hal hein? Sir mery apc surt 5000 xli hy. Usy battery per on kerty hein tu wo PFC wali middle led on kerta hy lekin fault ki led on nahi hoti. Utility power lagany per self test nahi kerta direct on ker deta hy. Battery per -dc bus low hoti hy. Relay 704 aur battery capacitor C804 bhi change ker dia hy. Lekin fault sahi nahi hua. Pls guide ker dein
Replace control card to varify fault
hey brother can you please help can i put this graphics card in my hp z230 sff with 240w supply and also can you please tell which is compatible power supply that can exactly fit in my this pc if i want to upgrade my psu.Thank you
Yes you can My power supply is also 240w and its working well
I don’t think sff cases have a psu upgrade option. But if you find any psu, you just need to make sure it fits inside and has the same connectors
@@AKElectroTech okay now i have to buy quadro p620 thanks brother
Ya Wala UPS app say mil Sakta hay ?
@@smartups1 Yes
Sir i have a problem with APC SUA 3000I dropping battery voltage very fast after switching to battery taking less than 2 minutes when fully charged, even after replaced with new batteries. Please help me with this Sir. And this happens even without any load Sir.
@@antonymakoye4410 Need software update for battery parameter.
I have a problem of UPS liebert 80-exl , it works good and no alarms and temprture inside it very good, but the proble is that its fan alwayes works in high speed however tempratue is not high
@@sabermoawad6544 There is no issue in UPS as well AZ in fans. These fan speed may vary due to temperature and may be UPS load etc.
Tengo una falla en un UPS APC SURTA 3000XL me da falla con led rojo en la parte de X y enciende el primer led de abajo para arriba qusiera saber que significa esa falla y como llegarle.. gracias
@@mariochiguila1812 Brother You have 110V UPS having inverter shortage. You may view my video on fault codes in AK Electrotech. Inverter is located near charger
Sir g mane yeh relay change krke bhi dekh li ni hu rha betry per bhi pfc fault arha hai
@@babarsultan8167 Check PFC portion for PFC fault
@AKElectroTech woh kon kon si sir plz guid
Hi do you have telegram ?
Hi No I haven't telegram but I have wattsapp +923215717132
Hello. I ask for help in resuscitating my APC SRT6KRMXLI. I launched a firmware update via the web interface of the built-in Network Management Card 2, it was copied to the APC, it installed and reported that it was necessary to hold the power button to turn off. But it did not work. Now it hangs with the same requirement and nothing helps. Before the update, there was version 04.0 (ID1013), updated to version 15.3 (ID1013). Will flashing the EEPROM chip help? Do you have firmware for it? The log says "Internal Comm. Fault. Event Code 154". When power is applied, the display shows: "Comm Event: To Pwr Off Press And Hold Pwr Button".
Dear AK Electro Tech, First, I would like to commend you on the quality of your content and express my gratitude for the continuous support you provide to users. Currently, I own an APC Back-UPS BR1100M2-ML, to which I have recently replaced the batteries. However, I have noticed that when a power outage occurs, the unit continues to shut down instead of operating with the new batteries. I have been informed that this issue might be resolved by updating the firmware of the device. I would greatly appreciate your guidance on the correct procedure to perform this update. Additionally, I kindly request, if possible, the link to download the corresponding firmware and the necessary tools to carry out this task. I look forward to your instructions and thank you in advance for your kind attention.
Thanks Check batteries because some time new battery may not function properly. Check battery connectors.
Aoa. Sir mery pass srt 5 kva Hy . Aur inverter hard ware kit fault Hy. Sari drives thek Hein aap k procedure se check kerne se. Sary igbt aur mosfets bhi thek Hy koi physical demage bhi nahi hy. Sir koi hal Bata dein
WAS Pl copy software in Description of video and reflash EEPROM
rx 550 ?
should work if its low profile
@@AKElectroTech Can you tell me a source for this motherboard? because I'm afraid this 240 won't hold up
Sir i am checking one surt3kva when i soft start battery relay 702 not closing,then i found q707 getting fault when start.i changed control card at that time q707 not getting fault.What may be the fault with control card having connector black flat type not the ethernet type
Sir I have another doubt can I use 10kva control to check 3kva to verify the problem with control card
@@ganeshm1735 there will be multiple faults that controller stop PSDR power.
@@AKElectroTech ok sir can I use 5kva control card in place of 3kva
@@ganeshm1735 Yes It it compatible with each other
sorry sir, I can't see the relay on the left corner because it's covered by the text AK ELECTRO TECH
@@namletrong-d2t Kindly send me problem of your UPS or tell me time of video where I said about relay. I will watch and tell you about relay
Sir, APC SURT 3KVA Online UPS occurred fault that error code light is top second and third are green (01100).. please how to repair this error..We will waiting your movie sir
@@PyaeSone-z4y3q Majorly there are three conditions. PFC shortage Q728 may be short Battery Fuses may be blown off.
What are some low profile CPU that will work I have Hp compaq 8200 Elite.
Sir i am checking surt3kva when start on battery giving battery capacitor soft start fault i have checked battery relay ok,th701 702 ok, checked q728,q701 ok but still have same fault.No short at pfc section also.Give me an idea to check
@@ganeshm1735 Have you checked battery fusea
@AKElectroTech fuses ok sir I found q707 faulty after replace also same fault,any other components to check
Sir srt6kva having p13 error with fault output distorted.i have replaced output capacitor still having same fault.give me a solution
@@ganeshm1735 Pl check log history
Checked log recent fault event code 168 output distorted,code 115 put svr over voltage
Code 115 output svr over voltage
@@ganeshm1735 Check resistor attached with output capacitor
@@AKElectroTechresistor value 0.3ohm
¿Alguien sabe cuál es el valor de R878 y Q704 (ya que se me dañaron por explosión de capacitor C770 de 20μF y 250 Vca)? Desde ya muchas gracias, el video es EXELENTE!
Yes R878 is attached with capacitor and have a value 0.15 ohm 7watt. The FET is a driver fir relay. You can see other FET used for relays, normally 150V because +24V is used on relay winding
It is N channel FET relay driver
inverter fault plz control card
@@sajidalam8565 ???
Asalamualaikum Wr.WB Sir, I don't have a SURT board. if I use a signal generator, what frequency and voltage do I use, can it be a square wave or must be a sine wave, thanks
@@aqilasyafamuthianingsih477 You can use 30khz to 50khz @ 15V signal.
@@AKElectroTech square Signal, Sir?
@@aqilasyafamuthianingsih477 Sine wave or you may apply sq wave
Sir apc surt input sence aur battery soft start fault pe vedio bnye
@@srana7804 Ok
Hello sir surt 10kva having inverter fault how to check igbt module and driver ic
@@ganeshm1735 For drivers check same video and for IGBT check IGBT testing video on my channel
@@AKElectroTech sir I have checked igbt module good.But for driver ic I don't know Hindi can u mention the pin number to check
@@ganeshm1735 Your country name and language
@@AKElectroTech I am from south India English ok
You haven't find English subtitle
Bhai which TYP IGBT is the Q1219 and others? Normal one 1200V 50A?
@@JaiDhatt You can use any IGBT having 50A1200V. It is not matter what number and company is.
@ Bhai Apc 3000 Event Code 157 fault IGBT from Inverter and the 20uf Cap. Allready changed . Any Idea? The Relais on the Bord are clicking. The Relai on the Output i dont know if its clicking
@@JaiDhatt Event code 157 deals with site wiring fault
@@AKElectroTech We only have 1 Phase neutral and grounding
@@JaiDhatt This is single phase and connect according to Line, Neutral and Earthing.
Can i put gtx 650ti? Single fan zotac
Yes. If its a Low Profile
asslamualikum Sir, video super sekali sangat membantu...
Thanks
boss mera 1 kva apc ups charg kar raha he lekin jab 220 nikal dete hen battrey low dikhata he battery b new laga li hen kaya karna pare ga
@@Saleem-dw2uo Software calibration needed
great boss❤
Thanks
hi if i want to change motherboard, is it a std micro atx?
How to fix if can't turn on 10KVA, Please help.
@@pirateszero You can watch my video for this issue.
Hello Thanks for the useful video I have an error with UPS SUA3000i it was working fine until yesterday Displays 3 LEDs (overload, battery charge, and battery error) along with 5 battery level LEDs, all flashing at the same time. this is when I don't connect the 220v power supply When connecting 220V voltage, 6 central LED lights will flash at the same time. i tried to restart it but no success. What is the cause and solution? Thank you and have fun.
One of battery relay is misbehaving, pl check all relays and relays drivers.
Boa noite mestre, gostaria de saber se consegue me ajudar, tenho aqui uma UPS APC 5Kva, ela esta apresentando erro Falha do conversor DC/DC luzes ( 01100 ), há algum vídeo que já tenha tratado disso ?
No video yet. But It is deals with PFC shortage, or may be shortage of Q728, or battery fuse blown off. Pl check
@@AKElectroTech Vou verificar, obrigado
Sir please APNA number dyn . جزاک اللہ خیرا
@@RahmatBabbar wattsapp 00923215717132
Sir Mary pass ye ups khula para hy wo bilkul on nhy Hu rah iski koi led on nhy Hu rahy .koi relay nhy lag rhY us K control volt drop Hu rahy hn kindly is ka circuit diagram send ker dyn. Jazak Allah
Check 13V at ON button if not present then check IC 4093 at control card.
@@AKElectroTech ok sir
Sir please share the apc 3kva main input power section circuit diagram.
@@RahmatBabbar Ok SRT or SURT
@@AKElectroTech SRT
@@RahmatBabbar Ok