Goodman Heat Pump Low On Refrigerant! Adding Leak Stop And Charging With R-410a!

แชร์
ฝัง
  • เผยแพร่เมื่อ 24 พ.ค. 2023
  • In this video I add One and Done Leak Sealant to a Goodman Heat Pump and top off it’s refrigerant charge with R-410a.
    Like and Subscribe

ความคิดเห็น • 68

  • @thewibb
    @thewibb หลายเดือนก่อน +2

    FINALLY someone purging the hoses correctly. Awesome video sir 😎

  • @ccthepope
    @ccthepope ปีที่แล้ว

    Nice information.

  • @anthonylosego
    @anthonylosego 25 วันที่ผ่านมา +1

    32.8 F, you're close to freezing your evaporator coils. It's possible in the condition it was in the customer lowered the thermostat. Could be a meat locker in there after recharging. And the leak stop didn't do that, it's the 3lbs you put in. You'll know (as a good tech) when you come back in 2 weeks to check the readings to see if it lost any refrigerant. I'm sure if the owner came home to a meat locker, he adjusted the stat. Could be poor air flow, but with a leak you probably just have a low charge situation. Leak stop is good on budget but as you said, a leak fix is better. I didn't see any caps on those Schrader valves so that might also be an issue. Core replacement is cheap and easy. Imagine putting leak stop in your compressor only to fix a leaky valve. lol

  • @chesstime356
    @chesstime356 ปีที่แล้ว

    I think you will be going back to this house to take check blower motor wheel evaporator coil , TD and check static pressure . Nice video fully watch.

  • @israelolguin1156
    @israelolguin1156 ปีที่แล้ว +4

    I had Nu-Calgon Ultimate Easy Seal 7.5 ton with UV installed in my RUUD R22 system and the charge has been holding for almost a year now and the house is a lot cooler. I also keep my coils clean and a Merv 1 filter but I did have a slow leak in the evap and Easy Seal 7.5ton UV worked. I did my homework first.

  • @Zepsswansong
    @Zepsswansong 3 หลายเดือนก่อน +6

    I would think the time the unit was running with a low charge while you were putting in the one and done, the evap coil frosted over, creating the issue of low evap pressure. When this happens, you only had to kill the condenser power for about 5 minutes, then you would have thawed the coil and pressure should come back up. That could have been verified by looking at the condensate drain and you would see that surge of condensate water coming out for a minute then stopping. If that didn't happen, then i would say cold room, dirty evap coil, fan speed or TXV issue. Just my thoughts here, from 41 years of experience.

  • @darylfortney8081
    @darylfortney8081 หลายเดือนก่อน

    Added it to my old r-22 that had a very slow leak and haven’t had a problem since. Been a few years.

  • @joshuaricks7730
    @joshuaricks7730 ปีที่แล้ว +8

    I don’t understand how you can add any refrigerant without cleaning that condenser coil first

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  ปีที่แล้ว +2

      My thought was that I’d rather have the head pressure a little higher on the cooler day that I did this repair. As opposed to cleaning it, having a sopping wet coil and have my head pressure even lower. As you can see from my readings, even with a full charge the dirty coil didn’t effect the head pressure.

  • @jmead6121
    @jmead6121 4 วันที่ผ่านมา

    good deal .Thanks .....not an true fan of one & done buy hey it does seem to work for some very small leaks with about an 65 - 75 % + - success rate

  • @EverythingHVACR
    @EverythingHVACR ปีที่แล้ว +4

    No load and possibly air flow, good call. Suction pressure rule of thumb saturation 30 -35 degrees less than entering air temp, so 65 degree space is possible.

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  ปีที่แล้ว +2

      Good Rule of Thumb!

    • @arrealhandymanservice4459
      @arrealhandymanservice4459 หลายเดือนก่อน +1

      That’s only for no load so if it’s 68 return air then the suction line temp should be arround 30

    • @EverythingHVACR
      @EverythingHVACR หลายเดือนก่อน

      @arrealhandymanservice4459 suction saturation would be 33 degrees at 68 degree return air, so any temperature over the SST "33" would be superheat. 30-degree suction line would indicate flooding.

  • @lanceditzler
    @lanceditzler 21 วันที่ผ่านมา

    Awesome. The whole evap coil will be covered in dye.

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  20 วันที่ผ่านมา

      Guess we’ll know where the leak is then.

  • @Sctronic209
    @Sctronic209 11 หลายเดือนก่อน

    I use them occasionally.

  • @jpenn727
    @jpenn727 ปีที่แล้ว +1

    I want to see the results.

  • @mark.r8900
    @mark.r8900 ปีที่แล้ว +1

    Hi, it's a very time consuming process to find a leak. Customers need to pay more for this process? Thanks

  • @jrh86
    @jrh86 ปีที่แล้ว

    Great instruction and information as always, what are your thoughts on your testo gauges ??

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  ปีที่แล้ว +1

      Love them. But the testo gauges, and testo smart probes are the only brand of electronic gauges I’ve used so I can’t compare them to others. I was on analog up until about 2 years ago.

    • @jrh86
      @jrh86 ปีที่แล้ว

      @@JeffsHVACAdventures thanks.👍👍

    • @anthonylosego
      @anthonylosego 25 วันที่ผ่านมา

      @@JeffsHVACAdventures Fieldpiece is rock solid. Never used Testo.

  • @maxpower8225
    @maxpower8225 ปีที่แล้ว +2

    Dirty evaporator or dirty air filter 👍

  • @taglyo96
    @taglyo96 ปีที่แล้ว +1

    Where did you buy that Leak Stop+? What store? I can't find it anywhere. And why did you choose that sealer instead of others (like Easy Seal)? This info would be very helpful to me. Thanks for the video!

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  ปีที่แล้ว

      United Refrigeration is where I got the leak soap and the One and Done. Really only used this brand because it was available. But I do use Easy Seal exclusively now.

    • @taglyo96
      @taglyo96 ปีที่แล้ว

      @@JeffsHVACAdventures Thanks Jeff! Much appreciated sir!!!

    • @rolohern9645
      @rolohern9645 3 หลายเดือนก่อน

      How is it use with 410a? Psi on the vapor line is usually in the 100psi and u need them to be under 65 psi. Thanks for the input.​@@JeffsHVACAdventures

  • @H2ObarryField
    @H2ObarryField 2 หลายเดือนก่อน

    What do you do if the low pressure switch is in lockout? Lennox system has a really slow leak. Plan to add sealant and then charge the system. However, can this be done when the compressor is off, due to the lockout?

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  2 หลายเดือนก่อน +1

      Bring the system up to full charge first and then add the sealant.

    • @H2ObarryField
      @H2ObarryField 2 หลายเดือนก่อน

      @@JeffsHVACAdventures Thanks Jeff. Is it okay to charge the refrigerant when switch is in lockout? I assume that the 410 tank pressure will add enough to deactivate the lockout, but not sure.

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  2 หลายเดือนก่อน

      @@H2ObarryField yea, it should take a good 3-4 lbs with the system not running. Should be enough to close the LPS.

    • @H2ObarryField
      @H2ObarryField 2 หลายเดือนก่อน

      @@JeffsHVACAdventures Thanks, Jeff. It worked!

  • @tman984
    @tman984 หลายเดือนก่อน

    how does this impact the lineset when it comes time to replace the entire system? gonna wreck the lineset?

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  หลายเดือนก่อน +1

      You should always change the line set when replacing the equipment when possible. But if you keep the same line set It wouldn’t bother it at all as long as you flush it properly.

    • @anthonylosego
      @anthonylosego 25 วันที่ผ่านมา

      @@JeffsHVACAdventures Blow a cleaner peg through it.

  • @DEValentine
    @DEValentine 14 วันที่ผ่านมา

    Will these leak-stops mess with TXV valves?

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  13 วันที่ผ่านมา +1

      I’ve never had a problem with them gumming up TXVs.

  • @1wash3r3
    @1wash3r3 2 หลายเดือนก่อน

    I paid someone to do the Max Seal Ultra and slso add 2lbs of R-22. He charged me $500 for the R-22 and $270 for the leak stopper. I was wondering if to high cost or this is average people are charging.

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  2 หลายเดือนก่อน +1

      Seems in line.

    • @chrisseabolt9593
      @chrisseabolt9593 2 หลายเดือนก่อน

      What color was the bottle of refrigerant

    • @darylfortney8081
      @darylfortney8081 หลายเดือนก่อน

      Leak stopper is like $40 on amazon and can be done at the same time as adding r-22 so he worked you hard on that upgrade.

    • @darylfortney8081
      @darylfortney8081 หลายเดือนก่อน

      Probably spent $30 in r-22 and should have taken all of 20 minutes to do.

    • @darylfortney8081
      @darylfortney8081 หลายเดือนก่อน +1

      That coil really needed cleaning, even a complimentary water hose spray down

  • @tommymein9046
    @tommymein9046 22 วันที่ผ่านมา

    How can you possibly charge a system accurately with filthy coils like that?

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  22 วันที่ผ่านมา

      It didn’t affect the head pressure as much as you would think.

  • @vladmir3203
    @vladmir3203 2 หลายเดือนก่อน +1

    Before to do something you must to clean this dirty condenser!!! :)))

  • @james10739
    @james10739 ปีที่แล้ว

    Letting refrigerant flow into your lines then cracking for a purge seems pointless to me the air that was in your hoses has already mixed with the refrigerant its not like the air is just compressed and separate from.the refrigerant the only thing that makes sense is if you had the line loose when you hook up the high side hose then maybe the refrigerant could push out the air but like that ita already mixed

    • @anthonylosego
      @anthonylosego 25 วันที่ผ่านมา

      Agreed. You need to open the high side and immediately purge. Otherwise, the air in your lines is leaking back into the system while you wait. The faster you purge after letting gas in the gauges the better. Ball valves are good for this, but you have to be quick while the pressure equalizes. Every second it is equalized allows air contamination to flow back into the high side connection. This is called diffusion. Higher concentrations move to areas of lower concentration by gas type. Hence, the air in the lines will bleed back into the system so long as the ball valve is open on the high side source. Minimizing the time the line is exposed to the high side source with air still in the lines is important. Bleed it quickly. Once you do that, you can take some time to push the stop leak in. A tiny bit is probably all that is required. You put a lot of liquid in the low side. I'd have turned it (the ball valve) each time very momentarily and do it half as many times as you did. Getting that last 3% of stop leak in there is less important than all that liquid on the suction side.

  • @channah8966
    @channah8966 หลายเดือนก่อน

    how we can buy that too

  • @rolohern9645
    @rolohern9645 3 หลายเดือนก่อน

    Don't get it! If u can't go inside the house,how is the ac on. If Temp inside is cold. Why is the ac running.

    • @anthonylosego
      @anthonylosego 25 วันที่ผ่านมา

      62F degree day. The subcooling shown would keep it fairly cool even with that level for that day. So the owner left it on. The subcooling was so low, it was just keeping up but running constantly. No match for a 90F degree day though.

    • @rolohern9645
      @rolohern9645 15 วันที่ผ่านมา

      @@anthonylosego thanks for ur response.

  • @tedzambrano8473
    @tedzambrano8473 หลายเดือนก่อน

    Some tech say it bad, will interfere and damage unit. Why can't they be on the same level, so much wishy-washy

    • @anthonylosego
      @anthonylosego 25 วันที่ผ่านมา

      Sticky sealants stick to your compressor too. So it will shorten its life. Like stop leak on oil leaks in your car. Cheap, but no really good in the long run. Last ditch effort for more time.

  • @donaldcurtis9229
    @donaldcurtis9229 3 หลายเดือนก่อน

    Took that little stem off.Guess what?The problem was the little Leo valve was stuck.That's how I lost all my refrigerator save myself a ton of money

  • @josrejonis7561
    @josrejonis7561 หลายเดือนก่อน

    this isn't a serious video right?

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  หลายเดือนก่อน +2

      Yes it’s a joke that only you understood.

    • @anthonylosego
      @anthonylosego 25 วันที่ผ่านมา

      @@JeffsHVACAdventures I understand your pension for working with customers. But for better results, insist on leak fixes. I suspect the Schrader valves may have had a hand in this leak. Simple fix, but a leak check could result in a paying customer and do it right. Better in the long run for the customer.

    • @JeffsHVACAdventures
      @JeffsHVACAdventures  23 วันที่ผ่านมา

      ​@@anthonylosegoi do push for leak searches. Most of the time, customers cheap out and take the least expensive route. This particular customer actually just sold this house last week, so that's why he was so cheap on this repair last year.