Mini-split Heat Pump Not Cooling / How To Properly Flare Without Leaks

แชร์
ฝัง

ความคิดเห็น • 272

  • @gordonborsboom7460
    @gordonborsboom7460 2 ปีที่แล้ว +14

    BTW the grooved sections of the tubing cutters are for cutting off flares.
    Put the flared end in the two groves in the rollers and the blade sits right next to the old flare to be cut off. This minimizes the amount of length reduction of the tube before re-flaring.

  • @Ted_E_Bear
    @Ted_E_Bear 2 ปีที่แล้ว +6

    Rick, I appreciate you working on equipment like this was at your house! You are Doing great work !

  • @DanielDavis1973
    @DanielDavis1973 2 ปีที่แล้ว +9

    mini-splits are very common here in the Seattle area because most houses and apartment/condo buildings weren't built with ducting. Until recently AC wasn't really a norm around here due to the normal air temperatures rarely getting much above 80 for most of the year. The past 10-15 years though have seen some pretty substantial increases in temps during the summer (hit around 110 in this area at the end of June this year) so a lot of people are getting them installed.

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว +6

      Interesting, Funny how the weather is taking a shit on that side of the country where most of the extremist climate change Legislation starts at🤦‍♂️🤣🤣

    • @daveyboy8907
      @daveyboy8907 ปีที่แล้ว +1

      ​@@HVACRSurvivalWeather Warfare... They never stop geoengineering.

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC 2 ปีที่แล้ว +5

    I have the Hilmor flare kit you referred to. It works great. The stop is nice as well. Lets you set the height for a nice flare. The kit also has swage adapters too. I also have the Hilmor hydraulic swage kit, i use it for any swage joint. The pistol grip and easy release are handy.

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว +1

      They are nice, I have the Hilmor pistol swagger and the bender. Thanks for watching!

  • @Eddy63
    @Eddy63 2 ปีที่แล้ว +5

    Gees Rickster you have a flair for flaring ... Lol ... Great job and vid ... Hey to Lora ...

  • @thesilentonevictor
    @thesilentonevictor 2 ปีที่แล้ว +1

    Man this is easy thanks for the video you a professional hvacr Rick 😆

  • @elmono4766
    @elmono4766 2 ปีที่แล้ว +4

    Pure 100% goobernomics. Lol. You are one funny entertaining man. Perfectly explained. Plus i learned what the groove is for after 28 years on the flare tool. Thanks. Keep up the good work

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว +1

      Awesome El Mono👍👍 thanks man!

  • @shine-cg9uf
    @shine-cg9uf 2 ปีที่แล้ว +3

    Great video. I use the flare kit they gave me at school. I use a nickel for thickness to size up the copper through the block. So far seems to work creating nice cone n proper fit. I also cut my thumb but didn't go to the hospital, I'm n idiot. Few days later I go get medical care n it was infected but thankfully didn't lose my thumb but too late for stitches. Missed a couple weeks of work. Thanks for sharing n that wrench tool was pretty cool.

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      I had a procedure done on it.

    • @shine-cg9uf
      @shine-cg9uf 2 ปีที่แล้ว +1

      Glad it's all good 👍

  • @hkhsm359
    @hkhsm359 2 ปีที่แล้ว +2

    Nice video
    Thanks for sharing your knowledge and experience

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      Your welcome, thanks 4 watching it!

  • @cruisemates
    @cruisemates 2 ปีที่แล้ว +3

    One of the best videos on vacuum processes and flares I have seen. You really know your stuff, especially about moisture and oil in the line sets. I am an amateur, but I would def hire you to do my installation. Most of the so-called mini-split experts around here do not even weigh in new coolant, they spitball it by reading PSI with the compressor running. Also - no nitrogen. I am new to your channel but I hope you have more videos like this. And I get why you dislike mini-splits - in theory they sound great, and if the install goes well they can be - but too many of them fail and then they are close to impossible to fix.

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว +1

      I have a few mini-splits videos and a lot of refrigeration. Click on my name HVACR Survival just below the thumbs button and that will take you to the channel, then you can search by all videos or category's

  • @matthewbeddow3278
    @matthewbeddow3278 2 ปีที่แล้ว +1

    Thanks for another great video.

  • @jayzzz1234
    @jayzzz1234 2 ปีที่แล้ว +2

    Hi rick great video, if the copper pipe isn't completely kinked its just slightly ovaled out. You can use the flaring block to straighten out the pipe, clamp and tighten rinse and repeat haha. Untill it straightens out, or the old school way i was shown use a shifter/ wrench jaws to straighten it out just round it off a little, end goal get that nut up enough to flare the pipe lol. Also i mostly do refrigeration but I've done some AC work over the years. Some of those split ACs have a recovery/ evacuation mode to open up the many thousands of solenoids contained within. You have to push this button on the PCB 10 times hold this button down for 10 seconds wait for this light to flash and so on.

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว +1

      Thanks man for the info! I use the crescent wrench trick sometimes.

  • @gas_man1565
    @gas_man1565 2 ปีที่แล้ว +1

    More and more of the ductless splits are being installed. when i first started in the trade, i rarely installed them and now adays almost every house has one. especially on the top floors of houses! When i grew up i didnt have an ac til i was like 21. been in the trade 20+ years things has changed since. good video

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      I fully understand, Same thing here. Thanks for checking it out gas man

  • @mansourramzey7711
    @mansourramzey7711 2 ปีที่แล้ว +1

    Another perfect job, and great learning video.
    🙏✌

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว +1

      Thanks for your kind words!

  • @crabmansteve6844
    @crabmansteve6844 ปีที่แล้ว +3

    I absolutely love mini splits, but some DIYers don't have any business installing hvac equipment.

  • @HVACingMyWay
    @HVACingMyWay 2 ปีที่แล้ว +1

    I use the yellow jacket 45 degree flaring tool and I love I’ve yet to have a bad flare out of it I actually used it today I installed two mini splits and I also always use nylog

  • @apollorobb
    @apollorobb 2 ปีที่แล้ว +3

    Amazing how the Basics of installation aren't adhered to . Great video Rick

    • @geomacdo
      @geomacdo 3 หลายเดือนก่อน

      On

  • @AG-tg9in
    @AG-tg9in 2 ปีที่แล้ว +2

    2:28 I see a lot here in Utah that most if not a good amount of them struggle with making a flare. The one you have is pretty good. For tubing idk why but I tend to stick with hillmore. I have the same flaring tool. Try the quick engage one it’s pretty great I have both but I tend to stick to the one your using. Perfect flaring looking on fleek haha good video Rick 👍🏻 💯

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      Awesome feedback Alex! Thanks 4 commenting!

  • @donnierobertson3088
    @donnierobertson3088 2 ปีที่แล้ว +1

    Nice job and video like always

  • @jarodreebel6686
    @jarodreebel6686 2 ปีที่แล้ว +1

    now i know what that groove in the pipe cutter is! I've wasted many inches of pipe lol thank you sir!!!

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      🤜🤛👍👍 glad I can help!

  • @farmerhunterjr
    @farmerhunterjr 2 ปีที่แล้ว +3

    Honestly wouldn't surprise me if those were the factory flares on the lineset. Ive learned the hard way to always check them before i screw them on. Ive even had one of my coworkers tell me after taking the training courses for mini splits they recommend cutting them off and redoing them using the flare nuts provided on the unit which are usually nicer heavier nuts. And also had great luck with the drill style "spin flare and swedge" tools. Between those and a tubing bender i hardly buy fittings anymore for soft copper.

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      I love my spin swage but I'm not sure I would trust the flare version because I looks like you could over flare it?

  • @winstonwright3613
    @winstonwright3613 2 ปีที่แล้ว +1

    Nice one Rick. I was wondering if you were gonna check the top flares after finding that one not-a-flare at the outdoor unit. Glad you did. I've actually been in the market for a torque wrench for those. So thx for the recommendation.

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      I haven't had any problems with it yet, but if the Nut gets larger it might not fit but I haven't found that to be the case yet. You can always use a claw foot on a regular torque wrench if you position it correctly.

  • @wd8557
    @wd8557 2 ปีที่แล้ว +1

    Noticed how you set the flare on the fitting of the valve then tighten nut by hand 100% correct. I have seen guy's just gab the line and start turning the nut on until it seat's

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      Thank you! I try to show the correct way because I learned the hard way.

  • @dennisssmock3553
    @dennisssmock3553 2 ปีที่แล้ว +1

    I'm getting rid of my Carrier Central air heat pump AC unit because I've had nothing but issues with it.. It's only 5 years old it was out at least once a year parts hard to find for. I'm going to be going back with Mini splits. The company I work for has several of they worked great.

  • @Ageehvac
    @Ageehvac ปีที่แล้ว +1

    Nice repair job...

  • @johnantonopoulous6381
    @johnantonopoulous6381 2 ปีที่แล้ว +6

    The worst thing about mini split is techs hate working on them so they charge a crap ton of money for no reason. My sister's quote was 35k for a 5 head 2 compressor install. I found both units for 11k so they are asking 24k for install.

    • @artics1031
      @artics1031 19 วันที่ผ่านมา

      No HVAC company will add the equipment price to the contract, to what you buy it for online, the 34k or whatever is for the quality workmanship and warranty, and ofcourse overhead.

  • @rogerf3622
    @rogerf3622 2 ปีที่แล้ว +11

    A word of caution. I have the Yellow Jacket torque wrench and inside the case cover it has a chart that states torque settings for pipe sizes that are way over what a mini-split manufacturer recommends. For example on a Pioneer system with ⅜ pipe, Pioneer recommends a torque of 19 ft-lbs while Yellow Jacket on their chart recommends 30 ft-lbs. For ⅝ pipe Pioneer recommends 34 ft-lbs and Yellow Jacket recommends a whopping 56 ft-lbs. 56 ft-lbs is way to high. Tightening too much will cause a leak by separating the flare from the pipe. And sometimes even break the flare nut. Be aware that copper pipe hardness varies and soft pipe (easy to bend) requires less torque. Check the data sheets on the mini-splits you are working on.

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว +3

      I looked up my specs from the MFG but I agree some do appear to high. Thanks 4 the info. I mainly do Mitsubishi and Carrier

  • @keepthinking2666
    @keepthinking2666 2 ปีที่แล้ว +2

    this is great its like watching and hearing myself work hahahahaha

  • @gregbowman3598
    @gregbowman3598 2 ปีที่แล้ว +1

    Good one Rick, don’t like flares or mini splits either👍

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      I cut out what I really feel😅🤣🤣👍👍

    • @gregbowman3598
      @gregbowman3598 2 ปีที่แล้ว +1

      @@HVACRSurvival I here you 😂

  • @jamesmooney5348
    @jamesmooney5348 ปีที่แล้ว +2

    I did a repair on a home owner diy unit. Had to open it up. In pulling a vacuum, I changed my oil 3 times. It would go cloudy very quickly. Wasn't my fault, so I just charged it.

  • @marjones69
    @marjones69 2 ปีที่แล้ว +3

    It does take a bit longer but i prefer to braze the lines that stick out from the Blower Unit, it just save a little headache and eliminate one leak point...I do not want to climb a ladder to look for a leak, no sir...Good work Rick

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว +1

      Long as your using nitrogen, why not👍

    • @marjones69
      @marjones69 2 ปีที่แล้ว +1

      @@HVACRSurvival always

    • @wakes_inc
      @wakes_inc ปีที่แล้ว +1

      Many manufacturers don't recommend brazing on mini splits. The reason is they have such fine mesh filters that they clog super easy. Sounds like you use nitrogen which is good - every time. Miss the nitrogen one time and it will clog the filter.

    • @marjones69
      @marjones69 ปีที่แล้ว +1

      @@wakes_inc I do flow nitrogen every time. I rather take a few minutes to set up than to come back on a leaky flare nut 20 ft in the air.

  • @karlschoen7297
    @karlschoen7297 2 ปีที่แล้ว +1

    I agree you touch it you own it

  • @ronwolkiewicz9570
    @ronwolkiewicz9570 2 ปีที่แล้ว +1

    some people that don't use a torque wrench tighten with everything they got, you can force the flare back to partially straight

  • @nitinsawant5453
    @nitinsawant5453 2 ปีที่แล้ว +1

    GOOD.👍

  • @berylwhite2983
    @berylwhite2983 2 ปีที่แล้ว +1

    I don't know when you got the cut but I'm so glad you got out stitches. ( your mom told you not to reach for the last piece of chicken)[ your Good Wife taught you the rule your mother's always right]🤣 no I truly hope the cut was nothing serious. Great work Thank for you for taking md

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      I had a procedure done on it 2 weeks ago and its doing great. I had my hand all bandaged up in a few of my videos that I haven't showed yet.

  • @badawesome3047
    @badawesome3047 10 หลายเดือนก่อน +2

    Some would say putting Nylog on the backside of the fitting rather than only on the mating surfaces will cause the torque to be inaccurate.

    • @HVACRSurvival
      @HVACRSurvival  10 หลายเดือนก่อน

      It could cause that but the whole point of lubrication is to not mare the rear surface and twist it. You can tell if it's getting too tight. Oil is fine too, it's just easier to carry nylog.

  • @ntsecrets
    @ntsecrets 2 ปีที่แล้ว +3

    I always feel like I’m going to snap those brass fittings when using my torque wrench. I have that same wrench.

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว +1

      That's why I verified I had the correct values. I have damaged the flares that are not correctly made. I found a chart with the main 4 or 5 brands requirements.

  • @tbelding
    @tbelding 2 ปีที่แล้ว +2

    For the items I carry in my car, that sit a long time, I use good qualilty Zinc Chloride Carbon Zinc batteries. (I also use them in remotes). They _will_ leak eventually, as all batteries will, but they don't leak an acid or alkaline. They leak salt water. They also don't leak as often as alkalines do. (People call Duracell the worst, they might be, but I've seen Energizer, Kirkland, etc, all die years before their 'use by' date when sitting in a device).
    No, they don't run as long, or under as heavy of a load, but batteries in a hot car wear out fast no matter what. In induction toners, probes, multimeters, remote controls, etc - they _still_ last years. (There's a reason that the smoke detector people use SHD batteries. It's not because they're cheaper anymore. It's because they last the full year necessary, and don't self destruct and eat the detector.)
    So, for a low drain (such as the digital torque wrench) device, that's used intermittently - ZCl batteries are perfect. If it's something you're using a lot, and drain batteries regularly - alkaline or NiMh for the win. Still a good idea to have spare batteries lying around. (Oh, if one leaks, you clean it up with water and a q-tip).
    Hope you save the copper pieces for recycling later :)
    Good to see you go those extra steps to make sure all of the connections are like they should be, rather than just fixing the obvious flaw (the loose one) and heading out. Too many people, especially if it's not _their_ name associated with the company, don't care about reputation.

  • @Parabellum-X
    @Parabellum-X 2 หลายเดือนก่อน +2

    My only complaint was that you didn't hook up your micron gauge to the opposite side of the system as your vacuum pump.
    Other than that, great job.

    • @HVACRSurvival
      @HVACRSurvival  2 หลายเดือนก่อน

      I still valve off and do the decay test once I’m down. Thanks for the feedback 👍👍

  • @freespeach1776
    @freespeach1776 9 หลายเดือนก่อน +1

    Excellent video…. Was wondering that you have the micron meter attached without an additional shut off… is there any reason others add a shutoff… Ty

    • @HVACRSurvival
      @HVACRSurvival  9 หลายเดือนก่อน

      They are worried about the gauge being damaged. Mine is built to take it, that's why I brag about this BluVac micron gauge as being the best. I've had Fieldpiece, CPS, and used a few others and they were all weak and didn't either hold up or they weren't as accurate.

  • @kevinpoore5626
    @kevinpoore5626 2 ปีที่แล้ว +2

    Well luckily I barely have to deal with flared fitting the only time I really do is with rehabbing some old gas other than that I tried to avoid them because I'm more of a plumber and do not have an HVAC license I do other things than plumbing but I have no EPA card. LOL

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว +1

      I've done all the departments at my previous employer, (plumbing, electrical and whatever needed done.) I don't have to any plumbing here😁. Thanks 4 watching!

  • @KadirYildiran
    @KadirYildiran 2 ปีที่แล้ว +1

    Rick you know air conditioner and washing machine, white goods are my business 😂😂 👍👍👍👏👏

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว +1

      The translation didn't work very good on that. I'm not sure what a white goods are and not sure if you meant you work on air conditioning and washing machines?

    • @KadirYildiran
      @KadirYildiran 2 ปีที่แล้ว +1

      @@HVACRSurvival Sorry Rick, I should have been more descriptive🙏... I install and repair appliances such as mini split air conditioners, household washing machines, dishwashers, refrigerators👍

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      @@KadirYildiran ok I understand now😁👍👍. That's a variety of things to keep it new.

  • @AVR-hf1rl
    @AVR-hf1rl 2 ปีที่แล้ว +1

    I think in one of your video's you were talking about the appion valve core removal tool as junk. Think I'm have the same issues. What kind are you using now and are the any good ? Thanks for your time

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      I like C&D, I use my appion for recovery and things that don't matter.

  • @UpRisingDown
    @UpRisingDown ปีที่แล้ว +1

    Burring makes the flare weak. And might get copper into the mini split. Some brands do have filters for debree though. Best is to use spring loaded cutter. And nylogg. And not to overtighten the flare.

  • @keepthinking2666
    @keepthinking2666 2 ปีที่แล้ว +1

    i love and wish i had the money for the navac little light weight battery vac pumps the jb is such a pain carrying around

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      There is a few times that it would be nice to have.

  • @AG-tg9in
    @AG-tg9in 2 ปีที่แล้ว +1

    8:40 don’t forget the flare nut! Haha it rarely happens to me but when it does that’s when my heads up my ass thinking of else what. 😯😲

  • @jrsmyth9761
    @jrsmyth9761 2 ปีที่แล้ว +2

    Fully agree with the comment on the ductless being a last resort and not service friendly!!!

  • @graywolf2694
    @graywolf2694 2 ปีที่แล้ว +1

    Good to know that they don't have protection, I want to install one on my RV, I think I'll install some low pressure cut offs, gonna install a drier too

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      Low pressure switch wouldn't be a problem just make sure you use a byflow dryer on the liquid line. They don't recommend it though just so you know

  • @sko242
    @sko242 9 หลายเดือนก่อน +1

    Q. Regarding pressure testing with nitrogen how many PSI and for how long?
    Thanks for great video..

    • @HVACRSurvival
      @HVACRSurvival  9 หลายเดือนก่อน

      The rating plate has the maximum pressure allowed and time depends on how determined you are to verify the system isn't leaking. 15-30 minutes is typical for a quick test with a digital gauge. Overnight to a couple days for large systems.

  • @bentlikeitsmaker
    @bentlikeitsmaker 2 ปีที่แล้ว +1

    Love hydraulic fittings hate flare

  • @Bass.Player
    @Bass.Player ปีที่แล้ว +1

    5.73 Lbs.? how many BTU's is that unit? Sounds like a lot of 410a? I really like these mini splits ,they are super efficient and very quiet with an easy install. I'm not so impressed with Carrier, hopefully it has a high pressure sensor? I hate that none of these M/S units have a high side port.

  • @greg778123
    @greg778123 ปีที่แล้ว +1

    Definitely need to know how to hack into them probably could be done with a raspberry pie and a few smart programs to get into its diagnostics and testing modes

  • @dra8907
    @dra8907 11 หลายเดือนก่อน +1

    Nice video. Where did you get that crescent wrench?

    • @HVACRSurvival
      @HVACRSurvival  11 หลายเดือนก่อน

      I should have a link to it in the description

  • @chetmyers7041
    @chetmyers7041 หลายเดือนก่อน +1

    13:50 Could you possibly get a "back-up wrench" on the hexagonal cap of the shut-off valve? You'd be coming at it perpendicular, but maybe the block and entire case would not be flexing so much.

  • @nuggetsweldingandrepair1703
    @nuggetsweldingandrepair1703 2 ปีที่แล้ว +1

    That’s why You use nitrogen to pressurize the system to check for leaks and nitrogen evacuate the moisture that’s in the system. Nitrogen purges the system to. Mini splits are very easy to work on. Dikin mini splits will also stop working if it’s low on gas so they won’t go in to vacuum

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      Nitrogen's only gonna do so much, Poe oil won't let go of the moisture like mineral oil will. That's why it's important to use nitrogen when you're brazing because the Poe oil scrubs the pipes clean and it's just a bad oil for people to do shit half ass.

  • @jamesmooney5348
    @jamesmooney5348 ปีที่แล้ว +2

    What you take your nitrogen up to?

  • @coldfinger459sub0
    @coldfinger459sub0 2 ปีที่แล้ว +3

    This is exactly why when you can (especially commercial) installation you install medium static indoor air handler or high static indoor air handler depending on your application so you could install filters and you have blower fan that doesn’t get dirty and a coil that doesn’t clog up.
    The wall mount I cut off the indoor flare fittings and braise it. Can never have a leak that way.

  • @johnwalker890
    @johnwalker890 2 ปีที่แล้ว +1

    Good job there, Rick. Call your apprentice and ask him how to fix the mini split, see what he says. Just kidding haha.

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      Unless you do muni-splits every day, it takes a while to be sure if a component is truly defective. Too many tests that you have to do in a certain order

    • @johnwalker890
      @johnwalker890 2 ปีที่แล้ว +1

      @@HVACRSurvival okay, no I don't work on them at all, I just do electrical maintenance, sometimes don't care for that either.

  • @nitinsawant5453
    @nitinsawant5453 2 ปีที่แล้ว +1

    Deepfreezer. Technician.from.India. 👍

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว +1

      Cool man! I love hearing from people from all over the world. Thanks for watching!

    • @nitinsawant5453
      @nitinsawant5453 2 ปีที่แล้ว +1

      please.send.more.different.videos.

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      Like what?

  • @theangrytechnician6649
    @theangrytechnician6649 2 ปีที่แล้ว +3

    I’m with you, I’m not a fan of ductless splits. But, seems to be the “way of the future “. Here’s hoping they see the error in their ways…. Good video as usual. Thanks for sharing.

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว +1

      Thanks Justin👍👍

    • @SupremeRuleroftheWorld
      @SupremeRuleroftheWorld 2 ปีที่แล้ว +3

      mini spits is fine from a good brand. carrier is NOT one of those for splits. stick to brands like MHI, panasonic and the likes that actually make their own units.

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      Normally we sell Mitsubishi👍 I agree with you, these people that wanna get in the market by letting someone else build their stuff is not a real bright idea. Reminds me of the generators made by made by Lennox and Carrier which were made by Kohler and Generac

  • @harrydickson4575
    @harrydickson4575 2 ปีที่แล้ว +2

    👍👍👍

  • @nilborne1
    @nilborne1 2 ปีที่แล้ว +1

    do you ever use a pre-made flare that has a sweat connection?

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว +1

      I have used them, but normally I just make them.

  • @pubchat2913
    @pubchat2913 2 ปีที่แล้ว +1

    Nice vid man, I’ve been in that situation before too.
    Hey did you consider at all to maybe add more refrigerant?

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      That would be a short term solution to a long term problem if I wouldn't have corrected it. The system pulled in air and moisture when it went into a vacuum, not to mention it would just have leaked back out.

    • @pubchat2913
      @pubchat2913 2 ปีที่แล้ว +1

      What can we do about all that moisture the system pulled in? And you’re thinking there is still a leak there somewhere?

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว +2

      It held at at a decent micron level when I was done. I'm not too worried about the moisture because of that. You could add a flare bi-flow filter dryer to it, the factory doesn't recommend it.

  • @sdsd4284
    @sdsd4284 2 ปีที่แล้ว +1

    Young tech hear Rick on these mini splits what voltages do u look for in diagnosing other than the high voltage I'm more familiar with conventional split high voltage and basic 24v .great video by the way

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว +1

      I've been through Mitsubishi's wreck of a school on City Multi and the M and P series.. To say the least I still call tech service. I don't work on enough of them to be proficient. Most problems with these are installation errors, refrigerant leaks, wiring problems along with dirty coils and fan blades.

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว +1

      The one thing I can tell you about voltages is how to know if the outside and inside units are communicating. They use 3 wires to power and communicate on. Two wires are the typical 230v, the third wire is DC voltage Mitsubishi will use the closest terminal to the DC terminal to communicate through. So if you measure Fluctuating DC voltage On those 2 terminals it's communicating. It averages 0v to 30v dc. Because the AC leg is isolated it can do this but FYI you will still get shocked if you touch the AC leg that carries the DC communications.

    • @sdsd4284
      @sdsd4284 2 ปีที่แล้ว +1

      Thanks Rick I appreciate you taking the time to respond men

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว +1

      No problem, you guys are the reason why I do these videos

  • @tronixfix
    @tronixfix 2 ปีที่แล้ว +1

    28:00 people always ask me why i’m bothering to invest money into my 40 year old R22 AC… QUALITY. I’ve seen so many new systems made from tin cans and plastic. I hate them, they have way to much electronics and sensors everywhere. I once had an AC job at a flour mill, they used small ACs to cool the controls and electronics of the milling machine. The control board of one of them failed and a replacement would have been around $800 from Germany. I replaced the control with some manual thermostats (luckily it wasn’t an inverter compressor) and a relay. They payed around $120 for spares and my salory.

    • @chetmyers7041
      @chetmyers7041 หลายเดือนก่อน

      You didn't pay yourself enough for your vast experience, knowledge, and resourcefulness. Hope you won a new customer with the "low-ball" price.

    • @tronixfix
      @tronixfix หลายเดือนก่อน

      @@chetmyers7041 I like to stay fair, it only took me an hour to fix it so I made around $90 for an hour of work. Btw when I asked them recently about the system they told me it's running perfect since the day I fixed it. I give it another 7-8 years.

  • @amicidavinci
    @amicidavinci 8 หลายเดือนก่อน +1

    What do you do when the lineset sizes are 6mm and 12mm? I can't find a 12mm flaring die ANYWHERE... 😢

    • @HVACRSurvival
      @HVACRSurvival  8 หลายเดือนก่อน

      Depending on what size I'm going, we talk in fractions where I'm at. 1/4, 3/8, 1/2, 5/8, 3/4, 7/8

    • @amicidavinci
      @amicidavinci 8 หลายเดือนก่อน

      @@HVACRSurvival ya, me too. Texas.

  • @christiansommer914
    @christiansommer914 2 ปีที่แล้ว +1

    Rick, would have been 🤤, if you heated your flair up after you made it..
    But Stella job as always👑👑

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      I've never heard that before, What is the thought behind heating it up the flare when your done?

    • @christiansommer914
      @christiansommer914 2 ปีที่แล้ว +1

      @@HVACRSurvival
      You heat it up, because you make the copper hard when you make the flair, and the you heat it up when you are done to make it soft copper again.

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      Interesting, I've never heard that before but makes sense👍👍💯

    • @jrsmyth9761
      @jrsmyth9761 2 ปีที่แล้ว +1

      @@christiansommer914
      Is that part of what a spin flare tool does?

    • @christiansommer914
      @christiansommer914 2 ปีที่แล้ว +1

      @@HVACRSurvival maybe Dave or Chris have heard of this.

  • @keepthinking2666
    @keepthinking2666 2 ปีที่แล้ว +1

    480 all day my friend my units range from 2ton to 234 ton, screw, scroll and semi-herm 22 and 410 lol a huge mess for my daily.

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      I hear you, I'll be on a small reach in coolers one call and a grocery rack or generator the next.

  • @stephwaylonwells3218
    @stephwaylonwells3218 2 ปีที่แล้ว +1

    👍

  • @keehn20
    @keehn20 2 ปีที่แล้ว +1

    Is that grove on the cutters really for the flare to ride in so you can cut it off close?

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      Exactly, sometimes you don't have much extra pipe to spare, like here on this call.

    • @keehn20
      @keehn20 2 ปีที่แล้ว +1

      13 years in the trade and I just learned this watching your video today lol 😂 amazing! Thank you 🙏

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      We don't do that many flares so it's understandable. Thanks 4 the feedback!

  • @hmedwards3
    @hmedwards3 2 ปีที่แล้ว +1

    Did you make that cheater with fuse and light, or do you use the Zebra one ?

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว +1

      I copied it and made it, my original one did not have a fuse or a lighted plug

  • @analogmoz
    @analogmoz 2 ปีที่แล้ว +1

    Wrestling Mini-Splits with Rick Flare!

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      Good one👍👍 I use to watch him😁

  • @issacrobertson
    @issacrobertson ปีที่แล้ว +1

    Did you have to pump down the system or was all the refrigerant lost?

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      It was all gone if I remember correctly

  • @Anthony-jq1ny
    @Anthony-jq1ny 10 หลายเดือนก่อน +1

    Should outside fan blow warm or cool coming from the house?

    • @HVACRSurvival
      @HVACRSurvival  10 หลายเดือนก่อน

      Are you in heat or cool mode? If cooling then warm, the inside and outside are the opposite of each other no matter the mode.

    • @Anthony-jq1ny
      @Anthony-jq1ny 10 หลายเดือนก่อน

      I appreciate the like ! But do you know if it should be blowing warm?

  • @keepthinking2666
    @keepthinking2666 2 ปีที่แล้ว +1

    i wonder if the wire was from a condenser fan with reversible connector

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      It was something I read on one of the Hvac forum's, yes, it was that wire. Most people never think about trimming that wire down and reconnecting it.. That wire does not need to be 5" long

  • @ntsecrets
    @ntsecrets 2 ปีที่แล้ว +1

    That’s looks like a midea clone too. Which is odd because the other clones like pioneer will detect if there is a leak condition (warm evap sensor is usually a dead giveaway)

    • @cruisemates
      @cruisemates 2 ปีที่แล้ว

      Got more information on clues to where the leaks are in a Pioneer system? I have had 5 of them, and 4 developed leaks after 2 or 3 years. @ntsecrets

    • @ntsecrets
      @ntsecrets 2 ปีที่แล้ว

      @@cruisemates almost always flare connections. I’ve found the factory made flares are often kinda crappy. Always inspect them closely. Usually if they are leaking you’ll see oil around them.

    • @cruisemates
      @cruisemates 2 ปีที่แล้ว

      @@ntsecrets Thank you for the info. I do electronics and can read DMMs, so I would happily get in there and read all those test codes, but the manual is so confusing in that department. There is a reply from HVACR about communication voltages. I will check that one out for sure.
      I installed my last two Pioneers and they are built much better than the early ones, they worked great for 2 -3 years, but then both pooped out. I have been looking for oil throughout the flares without taking them apart but it feels soapier and does not look blackish - just sticky from the insulation adhesive they use. But I DO suspect one or two were over-torqued. We were really straining on one of those flares (especially) - all took more tightening than I expected or ever saw a regular wrench user do. I am going to invest in the same digital torque wrench as in the vid. (we were using a modified ratchet style).
      I actually wanted to redo all the flares, but my helper (who knew more about the tools than I do) thought the flares we got looked pretty good. Now I know what to look for more closely.

  • @Sctronic209
    @Sctronic209 2 ปีที่แล้ว +1

    I believe the term is burnishing the flare.

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      Are you referring to the flare being scared from the tightening process without oil?

  • @wata_laf
    @wata_laf ปีที่แล้ว +1

    Did it have a 3 pipe compressor?

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      There are only two pipes between the evaporator and the condenser, otherwise it has a reversing valve in the condenser.

  • @duanefrost6068
    @duanefrost6068 6 หลายเดือนก่อน +1

    What kind of cheater cord setup are you using. New to HVAR/R and I absolutely love that.

    • @HVACRSurvival
      @HVACRSurvival  6 หลายเดือนก่อน +1

      Which cord was it?

    • @duanefrost6068
      @duanefrost6068 5 หลายเดือนก่อน +1

      @@HVACRSurvival the one with the light and fusible link.

    • @HVACRSurvival
      @HVACRSurvival  5 หลายเดือนก่อน

      I built it out of a lighted extension cord, and added a fuse to it, and some gator clips.

  • @moonsengineeringadventures623
    @moonsengineeringadventures623 2 ปีที่แล้ว +1

    Last good go-pro they made was the 4, everyone I have tried since has been bad.

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      Yeah, I've been very disappointed with all the locked up videos. This one here's never locked up and the battery life is longer Of course I've only had it about 2 weeks

  • @keepthinking2666
    @keepthinking2666 2 ปีที่แล้ว +1

    knipix yeahhhhhhh

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      Best tools out there👍👍

  • @brianmahoney154
    @brianmahoney154 2 ปีที่แล้ว +1

    I would reflare all connections and recharge to weight. We all better get used to it because they are becoming very popular.

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      Yep, and that's what I did👍

  • @roqueherrera8471
    @roqueherrera8471 ปีที่แล้ว +1

    14’ Wrench 🔧 😂

  • @ntsecrets
    @ntsecrets 2 ปีที่แล้ว +2

    One day when they start requiring GFCIs on AC disconnects those widow makers won’t work anymore ☹️

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว +4

      I'll get 230v to 120v transformer to step it down from a old RTU 😁

  • @keepthinking2666
    @keepthinking2666 2 ปีที่แล้ว +1

    thats crazy no low psi switch, crazy

  • @chetmyers7041
    @chetmyers7041 หลายเดือนก่อน +1

    15:09 Total JACKERY on the tie in to drain line. Someone didn't give a flip.

  • @chuco81
    @chuco81 6 หลายเดือนก่อน +1

    How much would this service cost?

    • @HVACRSurvival
      @HVACRSurvival  6 หลายเดือนก่อน

      I’m a technician not a salesman. I don’t see prices. Plus prices don’t mean a whole lot because that’s completely dependent on where you live at. People in Chicago, New York and California get screwed for three times as much as people in Ohio.

  • @ShadrachTheThird
    @ShadrachTheThird ปีที่แล้ว +1

    When in doubt , pull out 😅

  • @keithlassiter
    @keithlassiter ปีที่แล้ว +1

    Hacks use slip jaw pliers when a wrench is called for.

    • @HVACRSurvival
      @HVACRSurvival  ปีที่แล้ว

      If you say so, but people "say" a lot of wrong things👍👍🤣

  • @GeoffdeRuiter
    @GeoffdeRuiter หลายเดือนก่อน +1

    Very likely too much nylog was placed on the liquid line where it came out of the building. Couldn't reach torque specs then. Too much lube.

  • @wakes_inc
    @wakes_inc หลายเดือนก่อน +1

    There almost certainly wasn't an issue with the flare. That looks exactly like an over tightened flare which is very easy to do on the smaller pipes.... They didn't take much

  • @karaors8970
    @karaors8970 2 ปีที่แล้ว +1

    👍🤳🛠️🤳

  • @keepthinking2666
    @keepthinking2666 2 ปีที่แล้ว +1

    if schooled correctly you have it stick out about a penny thickness.

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      It really depends on the tool mfg, I've had ones where that is true and with this particular one it is not, it has to be flush.

  • @joshpearson1693
    @joshpearson1693 2 ปีที่แล้ว +1

    That's weird that it didn't turn off I had one I installed a couple years ago lose its charge from a leak on the evaporator and it threw a code and shut off. That was a three head unit.

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      Is probably a better built unit

    • @joshpearson1693
      @joshpearson1693 2 ปีที่แล้ว +1

      @@HVACRSurvival It was a carrier performance I assume they have same kind of boards and sensors.

  • @AG-tg9in
    @AG-tg9in 2 ปีที่แล้ว +1

    I use nylon on every mini split regardless what they tell you about it. Nylon doesn’t dry up. It’s like a rubber seal never had any leaks. 🥴🤔

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      I think it's great and convenient. But I use oil in some instances because it's easier to get into tight crevices behind certain types of fittings. Thanks for watching the video & commenting!

  • @Attest411
    @Attest411 2 ปีที่แล้ว +1

    Nylog= Poe oil at a different viscosity.. boom

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      Exactly, it was another TH-camr that said it.

  • @EverythingHVACR
    @EverythingHVACR 2 ปีที่แล้ว +1

    You know it's sad that no one can flare anything! Why can't we get low pressure switch on ductless, if that were a scroll you'd be screwed and probably Kill the compressor-10 should never happen! Well Done

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว +1

      Agreed Agreed Agreed!!!! Thanks Steve, Have a great weekend!!!

    • @jrsmyth9761
      @jrsmyth9761 2 ปีที่แล้ว +2

      Carrier, well made by Midea, don't seem to be fully engaged on all their equipment.
      Some of the Carrier branded units actually outperform Mitsubishi, but there are trade offs.

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      It looked just like the Lennox I repaired earlier this year. I figured it was from them

  • @electroshed
    @electroshed 2 ปีที่แล้ว +1

    and to the end users, if it's not working right and it's not lifeless, shut it off, you could save your unit!

  • @hvactechpr7872
    @hvactechpr7872 2 ปีที่แล้ว +1

    Most of the minis leak at flare connections... With the great QC from the "world's factory" found units with cracks in lines and bad brazes.....

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      True story!

    • @hvactechpr7872
      @hvactechpr7872 2 ปีที่แล้ว +1

      @@HVACRSurvival yep your right!!! And add to the list the no name prep tables that always clog the drier and captubes that have splices lol

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      Cheap junk👍

  • @tonylaw196
    @tonylaw196 2 ปีที่แล้ว +1

    It should be OEM by Midea and the quality is worst. I have a experience that the Carrier spilt AC always leak all refrigerant, I find all the copper pipe are normal, it should be leak inside the outdoor unit. I replace it with a Dakin spilt AC.

    • @HVACRSurvival
      @HVACRSurvival  2 ปีที่แล้ว

      We normally sell Mitsubishi. I still have issues with there tech support running you around in circles because they don't have proper training either. The Japanese don't fully disclose how everything works with there own technicians🤦‍♂️🤦‍♂️🤦‍♂️, Only what they need to know.