- 82
- 170 739
Power Plant with Pratyush
เข้าร่วมเมื่อ 3 ม.ค. 2011
Hi friends,
"Power plant technical Pratyush" means just starting of sharing technical knowledge to all my friends. I am Mechanical Engineer , BOE and certified Energy manager Presently I have 16 years of work experience in Thermal power plant operation and maintenance the prime purpose to creat this channel is that to share the technical knowledge across the intrested persons.
My E mail id is kpatelbla@gmail.com
"Power plant technical Pratyush" means just starting of sharing technical knowledge to all my friends. I am Mechanical Engineer , BOE and certified Energy manager Presently I have 16 years of work experience in Thermal power plant operation and maintenance the prime purpose to creat this channel is that to share the technical knowledge across the intrested persons.
My E mail id is kpatelbla@gmail.com
Boiler Drum lifting procedure.
Boiler Drum lifting with important calculations.
@kpatelbla
@rahulsirclasses1987
@PowerPlantDiscussion
@PowerPlantGuruji
@BhagwanSRathore
@kpatelbla
@rahulsirclasses1987
@PowerPlantDiscussion
@PowerPlantGuruji
@BhagwanSRathore
มุมมอง: 340
วีดีโอ
Why Motor heating takes place at Low voltage ?
มุมมอง 2804 หลายเดือนก่อน
Why Motor heating takes place at Low voltage ? WHY MOTOR DRAW HIGH CURREN AT LOW VOLTAGE? Understand full concept behind this. @PowerPlantDiscussion @PowerPlantGuruji @BhagwanSRathore @rahulsirclasses1987
Boiler Turbine Absolute cold start-up curve
มุมมอง 6995 หลายเดือนก่อน
Boiler Turbine Absolute cold start-up curve th-cam.com/video/2RZV0xM9k8U/w-d-xo.htmlsi=e99uQ4KuWX2c8BsD th-cam.com/video/dqR_IoiYvTI/w-d-xo.htmlsi=cZ-O7xjB7jNVl9xo
Electro static Precipitator (ESP)
มุมมอง 7125 หลายเดือนก่อน
Electro static Precipitator (ESP) @PowerPlantDiscussion @BhagwanSRathore @rahulsirclasses1987 power plant discussion, power plant operation, ESP, Electrostatic precipitator, Function of ESP, Function of electrostatic Precipitator in Hindi, Corona effect, What is Corona in ESP, Why ESP works on Corona effect, Rapper in ESP, Collecting plate in ESP, Emitting electrode in ESP, Gas distribution pla...
How MDBFP rapid start -Up SOV works ? (Hindi me samjhe)
มุมมอง 6686 หลายเดือนก่อน
Step-by-Step Guide to Motor Driven BFP Rapid Start Up Process ? How MDBFP rapid start up SOV works? MDBFP rapid start up in detail. BFP rapid start up MDBFP auto pick up MDBFP rapid start & Protection of motor th-cam.com/video/WILqwqeLd9E/w-d-xo.htmlsi=RRiSaygZSVY6w9K5 @rahulsirclasses1987 @PowerPlantDiscussion @BhagwanSRathore
Coal Pulveriser Ignition permit | Coal Mill Ignition Energy | Coal Mill ignition permit logic
มุมมอง 9296 หลายเดือนก่อน
Coal Pulveriser Ignition permit | Coal Mill Ignition Energy | Coal Mill ignition permit logic. th-cam.com/video/lvC5ukKj3dw/w-d-xo.htmlsi=AA6Umx7OcvtRkLQ1 www.youtube.com/@kpatelbla Power Plant technical pratyush @rahulsirclasses1987 @PowerPlantGuide @PowerPlantGuruji @BhagwanSRathore @PowerPlantDiscussion
When Turbine shaft self sealing occurred ? What Conditons necessary for Turbine shaft seal charging
มุมมอง 1.1K7 หลายเดือนก่อน
When Turbine shaft self sealing occurred ? What Conditons necessary for Turbine shaft seal charging ? @PowerPlantDiscussion @PowerPlantGuruji @BhagwanSRathore @rahulsirclasses1987
Boiler circulation water pump important parameters & concept of Heat barrier
มุมมอง 1.2K7 หลายเดือนก่อน
BCW Pump Heat barrier and motor cavity importance. Boiler circulation water pump important parameters & concept of Heat barrier Power Plant technical Ptatyush @rahulsirclasses1987 @PowerPlantDiscussion
How Super Heater Attemperation Flow calculated? (For better resolution watch in 4K)
มุมมอง 6347 หลายเดือนก่อน
How Super Heater Attemperation Flow calculated? th-cam.com/video/BCWDZ4a6g5E/w-d-xo.htmlsi=iTXmQz0O_VAveAvO th-cam.com/video/1YC8f0D9Nzg/w-d-xo.htmlsi=oH7zmhpRPPBtX4Ql @PowerPlantDiscussion @BhagwanSRathore @rahulsirclasses1987
Bowl Mill internals & Working Principle | Coal mill internals & Working Principle | Coal pulveriser
มุมมอง 3.9K8 หลายเดือนก่อน
Bowl Mill internals & Working Principle | Coal mill internals & Working Principle | Coal pulveriser
How steam flow takes place in Boiler pressure parts | Boiler Pressure parts location
มุมมอง 1.6K8 หลายเดือนก่อน
How steam flow takes place in Boiler pressure parts | Boiler Pressure parts location
Why Boiler Drum Pressure increases when coal feeding increased in Bottom Mill.
มุมมอง 1.2K8 หลายเดือนก่อน
Why Boiler Drum Pressure increases when coal feeding increased in Bottom Mill.
Boiler Feed Pump change over | BFP change over
มุมมอง 1.1K8 หลายเดือนก่อน
Boiler Feed Pump change over | BFP change over
Boiler Drum internals & Their Functions.
มุมมอง 8448 หลายเดือนก่อน
Boiler Drum internals & Their Functions.
Boiler light up procedure in detail | Boiler start up
มุมมอง 1.6K8 หลายเดือนก่อน
Boiler light up procedure in detail | Boiler start up
Start permissives of Motor Driven Boiler Feed Pump (MDBFP) |BFP| Boiler Feed Pump
มุมมอง 8419 หลายเดือนก่อน
Start permissives of Motor Driven Boiler Feed Pump (MDBFP) |BFP| Boiler Feed Pump
Motor Driven Boiler Feed Pump (MDBFP)
มุมมอง 3.5K9 หลายเดือนก่อน
Motor Driven Boiler Feed Pump (MDBFP)
Boiler Super Heater control loop kaise kaam karta hai Hindi me samjhe.
มุมมอง 8219 หลายเดือนก่อน
Boiler Super Heater control loop kaise kaam karta hai Hindi me samjhe.
How Total air Flow Control loop works in Boiler ?
มุมมอง 1.6K9 หลายเดือนก่อน
How Total air Flow Control loop works in Boiler ?
Boiler pressure part Arrangement, FW flow path.
มุมมอง 7599 หลายเดือนก่อน
Boiler pressure part Arrangement, FW flow path.
coordinated Master control (CMC) I Coordinated control system ( CCS)
มุมมอง 1.7K10 หลายเดือนก่อน
coordinated Master control (CMC) I Coordinated control system ( CCS)
Turbine Follow Mode (TFM) I Turbine follow Boiler (TFB) in detail I Turbine follow mode logic
มุมมอง 1.8K10 หลายเดือนก่อน
Turbine Follow Mode (TFM) I Turbine follow Boiler (TFB) in detail I Turbine follow mode logic
How Aux power optimization done by PA HDR pressure optimization in Power plant
มุมมอง 48110 หลายเดือนก่อน
How Aux power optimization done by PA HDR pressure optimization in Power plant
Thermal power plant Generator Hydrogen ( H2) Dryer detail.
มุมมอง 3K10 หลายเดือนก่อน
Thermal power plant Generator Hydrogen ( H2) Dryer detail.
How MDBFP scoop tube works in VOITH coupling | MDBFP flow regulation by Scoop
มุมมอง 4.4K10 หลายเดือนก่อน
How MDBFP scoop tube works in VOITH coupling | MDBFP flow regulation by Scoop
Why Boiler Drum vent Close at 2 kg/cm2 during start-up |Why Boiler Drum vent open at 2 kg/cm2
มุมมอง 1.1K11 หลายเดือนก่อน
Why Boiler Drum vent Close at 2 kg/cm2 during start-up |Why Boiler Drum vent open at 2 kg/cm2
Super critical & sub critical Thermal Power plants comparisons
มุมมอง 1.6K11 หลายเดือนก่อน
Super critical & sub critical Thermal Power plants comparisons
Why LDO gun rotation recommended during Boiler Light-up | Boiler Drum top bottom | Boiler light
มุมมอง 58111 หลายเดือนก่อน
Why LDO gun rotation recommended during Boiler Light-up | Boiler Drum top bottom | Boiler light
PA Fan lube oil system & Control oil system in detail
มุมมอง 1.6K11 หลายเดือนก่อน
PA Fan lube oil system & Control oil system in detail
How Power plant Safe shutdown carried out
มุมมอง 82011 หลายเดือนก่อน
How Power plant Safe shutdown carried out
Sir ji key phaser ka kya kaam hota hai ....?
Please make video for maintenance related
Sir why in post purg trip if furnace postive the why id tripping is given
In our plant coal is 400 TPH and we maintain 2100 TPH then it will be 5 kg .Is it correct
Yes 5.25 kg air /kg of Coal.
Sir y there is 30% CV and 100% CV.At what load & pressure change over will be done .is the pressure will be more than critical pressure to do change over in 660 MW
It is related unit load means upto 30 % of Unit load u can use 30 % line of FW for 660 MW it's is 198 MW and more than it 100 % FW line. Don't wait for last moment for unit stability start it's change over in bwletween 25 to 30 % of Unit load.
Sir plz make more videos.
Ok
Sir why temperature difference between Hp exhaust & CRH temperature,
@@kpatelblaWhy in post purge fan trip I'd trips when furnace pressure become positive, ideally it should run to drive out the combustibles.Also in post purge trip do ID & fd trip on both furnaces postive & negative or only in positive.Plz explain
@@kpatelblaSir why temperature difference between Hp exhaust & CRH temperature,
Sir good morning Sir boiler commissioning ka video upload kijiye 660 mw
Sir as a boiler desk engineer, load ramp up or down me , boiler kaise behave karta hai , sh spray, burner tilt , ehtc , drum pressure kaise control karen, spray set point barana hai kab ghatana hai kab, metal excursion kaise prevent karen, , kindly explain, i have not getting concept clear where i work.please explain in a video . Or i want to clear in personal help.sir. Kindly give any contact
Sir please explain the purpose of small C and large C header in 2nd pass.
Ok
Thank you so much sir... Nice information..
Lube oil system ka video banao na sir aop jop acop etc please 🙏 abhibtak achha information video nahi bana hai
Ok
Sir.... 7:36 pr aap bole ki feeding change karega. M kah raha ki coal feeding change krega ki valve opening percent change krega.....? Kyonki ultimately pressure control tho valve se related hai na..... Bina feeding change kiye valve ka position change ho jaayga aur ref value of pressure mil jaayga??? Sahi socha ki nahi sir?
Sir, what are the problems that can arise while starting and stopping ldo gun? If it comes then how to handle it, make video on this also.
Ye burners k burnout ki kia reasons ho skti haan
Improper opening of SADC. Improper velocity of pulverised coal. Age factor of old burner. Volatile matter variation in coal for long run.
@kpatelbla sadc means sec air control dampers
Yes
Excellent ❤❤❤❤❤❤ sir
Sir please make a vedio about HPH & LPH charge on DCS
@@hanuman5800 ok
Working oil pump and lub oil pump voith coulping k inside hota hai??dono pump me kya difference hai?
Yes, it like MOP of main Turbine.
@@hetalrana8780 both Pumps are different one for lubrication another for supply working oil to VOITH coupling
S
dear sir, when we using pressure control mode operation and what is the turbine load for pressure control mode operation for 600 MW turbine.
@@chintu-o2l3n Pressure Control mode used to maintain desired pressure of Main steam evantualy RH circuit also maintained to avoid starvation of RH and pressure parts.
Sir, please explain hydrogen circulation in generator and cold and hot gas temp.
Ok
Thank you sir.sir, please give the information regarding load sharing capacity of HP ,IP,LP turbine as stated like 26%,34,40 percent of each.so what is load share and which aspect like steam flow, energy etc.
Vedeo boht hi vadia laggia ji mein dekhia v te subscribed v kitaa ji 🙏 ❤
do you forget to arrest the winch ?😀
Sir What is the cavity temperature and why cavity fill up through water.
To provide cooling for motor winding actually motor is close contact of Boiler hot Feed water
Sir BPA angel kitna hota h
0 to 33 Degree.
Sir can we run unit full load with one FD FAN, what parameters we should watch
Very well informative sir ❤❤
Thank you sir for stating valuable information.sir,can you tell us about reasons for hp exhaust temperature high.
@@jagdishkandekar917 Mostly this is happened when Turbine is in rolling condition for long time in this case steam passing through Turbine without doing useful work.
Sir, please explain about cold and hot gas temp.in generator
Ok
Fruitful information sir.sir,what will happen if coal layer secondary air opened greater than 20%
Will disturb Furnace to Windbox DP due to disturbance in PA & SA ratio.
Thank you sir
Very nice teaching Sir
Bfp mai booster pump kyo Diya rahata hai aur isako nahi rakha to kya hoga sir plg.jaldi bataiye
@@pravinselkar7439 Agar BFP ka suction me pressure below vapour pressure hoga to steam bubble form hoga koi bhi pump steam water ke mixture ko compress nahi kar sakta is case me steam bubble impeller ke pass akar burst hoga jis karan impeller me cavitation hoga isi ko prevent karne ke liye booster pump dekar BFP suction par pressure increase karate hai. Agar samajh me aaya ho to please comment karke batana.
Thank you sir
Great sir
Dear sir please 🙏 make a video on max dna hardware architechure Or net working sysytem please sir just a short video
Jai ho 🎉❤🎉❤🎉❤🎉
Excellant video sir
In 660MW unit where i work, we can only give load target when on CSS, but cant give load target in TF mode. So my Question is how load will increase if we cannot provide target load on HMI. Here in our powerplant, we increase load by increasing coal manually (rest on auto air, fW etc) ., donot give load target when on TF. ( iam unable to understand how boiler controller works here when there is no load target )
couldn't understand difference between meachinal seal cooling and jacket cooling , please explain in detail
Sir Why Gate Blower installed near ID fan O/L gate ? While there is no any blower after PA & FD Fan O/L gate.
To clean ash content near gate seal which reduce the chance of gate motor over load.
@@kpatelbla Thank You 😊 sir
Good explanation sir
What should be the rate of raise SH and RH steam temperature during cold startup.
Generator ABC triping
Thank you so much sir .... pressure control to load control changeover ke liye video bana dijiyega sir ....
Ok
When TSC fault occurs on EHTC page when unit is in service
Very nice ❤❤❤🎉
Very nice sir ji🎉❤🎉🎉❤
SIR CAN WE TAKE DM WATER THROUGH BOILER FILL PUMP IN DEARATOR IN CASE WHEN DM MAKE PUMPS ARE INSUFFICIENT TO ADD MAKE UP WATER IN CONDENSER. SPECIALLY WHEN WE HAVE OPENED IBD TO REDUCE SILICA OF BOILER.
@@vibhanshu1 it can be taken in case xtream urgent only.
Water flow