ความคิดเห็น • 50

  • @johnabiodun5540
    @johnabiodun5540 ปีที่แล้ว +4

    Next time try a hairdryer on the Vaillant board. Unplug all the connections heat them all up then plug them back in. Works a treat! 👌🏽

  • @sudhiradhikari19
    @sudhiradhikari19 ปีที่แล้ว +2

    One more thing I forgot to mention, watching your back of van video I changed woster return manifold, it was my first major job on my first month of gas engineer job with no plumbing background, it all went well, thank you so much for simplifying things.

    • @advancedboilertraining
      @advancedboilertraining  ปีที่แล้ว +2

      Ah im glad to hear the video helped! Before I done this repair I went back and watched my own video 😂 I haven’t changed a return manifold in a while

  • @user-li8gr8ur8l
    @user-li8gr8ur8l 4 หลายเดือนก่อน

    A top quality video. ❤. I love how much detail you share. Thank you.

  • @onelifelivit.5183
    @onelifelivit.5183 ปีที่แล้ว +2

    Always enjoy fault finding,tanx for the upload

  • @yensabi
    @yensabi ปีที่แล้ว +2

    Nice one , I had exact same fault on a vaillant last November , kept cutting out but not blowing fuse , unplug fan and it stayed on rang the tech and was told it was pcb , had spare on van and changed all good , 20 years working on vaillants and never seen that fault before...
    cheers
    👍

  • @sudhiradhikari19
    @sudhiradhikari19 ปีที่แล้ว +3

    Always enjoy your video, wish you could have showed the outer part of the flue. one little request if you do vertical flue can you please make video in detail please, there are no videos on TH-cam for vertical flue installation.

    • @advancedboilertraining
      @advancedboilertraining  ปีที่แล้ว +2

      Next time I do a vertical flue I’ll make sure to upload it for you 👍

  • @mikegallagher2107
    @mikegallagher2107 ปีที่แล้ว +2

    great content love ya videos really good keep up the good work

    • @advancedboilertraining
      @advancedboilertraining  ปีที่แล้ว +1

      Ah thanks Mike! I really appreciate all your comments. Glad you’re enjoying all the content

  • @BENNU-RETAIN
    @BENNU-RETAIN ปีที่แล้ว +1

    high quality video keep posting👍👍👍

  • @muhammadAli-kd2zp
    @muhammadAli-kd2zp ปีที่แล้ว +2

    Excellent video thank you for your time

  • @abdulaziz-pb5ni
    @abdulaziz-pb5ni ปีที่แล้ว +1

    Thanks for uploading I love fault finds and I like long videos like u do

  • @ozwellalford5015
    @ozwellalford5015 ปีที่แล้ว +1

    I like your videos its really educative

  • @sheriefgerges7789
    @sheriefgerges7789 ปีที่แล้ว +1

    You are brilliant engineer as knowledge and explanation

  • @mattygeepph4115
    @mattygeepph4115 ปีที่แล้ว +2

    Top work bud had the same fault on vaillant ecotec pro after installing a rf stat think it's quite common fault 😎👍😎😎👍😎👍😎👍

    • @advancedboilertraining
      @advancedboilertraining  ปีที่แล้ว

      Yeah you’re the second person to say that they also had this recently, must be common. Thanks for the comment 👊

  • @olalekanoyedokun4494
    @olalekanoyedokun4494 ปีที่แล้ว +1

    I remember very well, I had exactly the same problem with this valliant model 3 years ago. I already got a new fan unit before valliant technical support told me it was PCB. Until this moment, I still have fan unit sitting their in my garage

    • @advancedboilertraining
      @advancedboilertraining  ปีที่แล้ว

      Haha, yeah if I didn’t call technical I would’ve thought it was the fan as well!

    • @willemgijs3803
      @willemgijs3803 5 หลายเดือนก่อน

      Those vaillant prints aren't the bests haha. PCB I mean. You guys in UK don't have intergas? Seems to be the best combi-boiler to me. No Three-way-valve. Two seperare circuits.

    • @willemgijs3803
      @willemgijs3803 5 หลายเดือนก่อน

      Im a boiler mechanic. Service technician whatever you want to call it, in the netherlands.

  • @paulrossiter9567
    @paulrossiter9567 ปีที่แล้ว +2

    Great video 🎉 I felt your pain under that Vaillant lol …

  • @delboy6384
    @delboy6384 ปีที่แล้ว +2

    Top vid geeza, Vailant repair a good find

    • @advancedboilertraining
      @advancedboilertraining  ปีที่แล้ว +1

      Thank you!💪

    • @delboy6384
      @delboy6384 ปีที่แล้ว +1

      I'm in the market for a press tool, just for 15mm 22mm and 28mm. Which brand do you recommend mate?

    • @advancedboilertraining
      @advancedboilertraining  ปีที่แล้ว

      @@delboy6384 I’ve been using Rems and haven’t had an issue with it so far. I’ve also tried the novopress which some people prefer. But personally I like rems

    • @delboy6384
      @delboy6384 ปีที่แล้ว +1

      @@advancedboilertraining cheers for replying, all the best

  • @colinfleming2244
    @colinfleming2244 ปีที่แล้ว +1

    Ye can the crap on the right hand manifold. Rhm prv flow adaptor.

    • @colinfleming2244
      @colinfleming2244 ปีที่แล้ว

      Never had to take gas pipe out. But wd is yer friend

  • @jamalamin082
    @jamalamin082 ปีที่แล้ว

    Hi, could you do a vid on how to replace a low water pressure sensor on a Potterton promax 28he ?

    • @strongbow310
      @strongbow310 ปีที่แล้ว

      Promax combi ?
      Same as a gloworm

  • @mohmmadmohseni8404
    @mohmmadmohseni8404 6 หลายเดือนก่อน

    Perfect 👍

  • @kennethbarr6842
    @kennethbarr6842 ปีที่แล้ว +1

    Hi Top Content, Where Do I Get THE Sprit Of Salt An The Samll ALAN KYE FOR PRVS PLEASE?

    • @advancedboilertraining
      @advancedboilertraining  ปีที่แล้ว

      Wera Allen Key Set: amzn.to/3xfbW6W
      Spirit of salts any plumbing shop

  • @The_Dua
    @The_Dua ปีที่แล้ว

    In the long run is it not more beneficial to just get a newer boiler fitted?

    • @frosty_soda
      @frosty_soda ปีที่แล้ว

      Why? Just get another 10 years out of it 😊

  • @kennethbarr6842
    @kennethbarr6842 ปีที่แล้ว +1

    HI And WHATS Your PRESS TOOL Please?

  • @stuarthughes808
    @stuarthughes808 ปีที่แล้ว +1

    I always put an old towel over the pcb when I work on any boiler to try and stop any drips. 👍🏻👍🏻

    • @advancedboilertraining
      @advancedboilertraining  ปีที่แล้ว

      Definitely going to start doing that, it’s really not worth the risk

    • @olalekanoyedokun4494
      @olalekanoyedokun4494 ปีที่แล้ว

      I always practice towel techniques to afford flooding pcb. My hair dryer is always handy as well