Lazy Spa E02 Error - Easy replacement of the impeller shaft.

แชร์
ฝัง
  • เผยแพร่เมื่อ 21 พ.ค. 2020
  • This short video shows how to remove the pump on a Lazy Spa Egg style unit, shows how replace the impeller shaft, very easy fix and not expensive, so you dont have go out to buy a new Hot Tub!!!!!
    Looking to retrofit?
    Impeller assembly approximate Specs: Inner Shaft Length 70mm, Shaft Diameter 3mm. Impeller Diameter (Rotor and plastic impeller complete) 16mm, (combined length of rotor and impeller) 54mm. Impeller total blade Diameter 39mm x6 paddles in all, depth of the blades 8mm.
    Hope this information helps you find an alternative make of Impeller to fit your defective inner workings of your pump.

ความคิดเห็น • 258

  • @prendlp1705
    @prendlp1705 2 หลายเดือนก่อน +1

    Brilliant instructions! Received my replacement impeller in the post today, fitted it and low and behold the hot tub is working again!! So very pleased! The part I removed was definitely gone - completely split and rusted. Thanks so much 👍😁

  • @dianesellers4407
    @dianesellers4407 3 ปีที่แล้ว +2

    So pleased we found you the advice and the instructions for the repair were spot on E02 is no more!!

  • @angelamangnall6334
    @angelamangnall6334 11 หลายเดือนก่อน +1

    Thanks from New Zealand. We bought the new impeller and installed it following your very clear and concise instructions. Our spa is currently reheating and I'm looking forward to getting in! Thanks

  • @clarestewart6306
    @clarestewart6306 3 ปีที่แล้ว +5

    Hi after spending a noisy 2-3 months of E02 error and constant filter changes etc etc, I came across this email, spent £9.99 on a new impeller, changed it this morning, it is now running as quiet as a mouse. fingers crossed it now heats up and I can get back in tomorrow. Thank you so much. Clare

  • @MarkBajaj
    @MarkBajaj 3 ปีที่แล้ว +1

    Thanks for the Video Dave! I have a HydroJet pump, slightly different to pull apart, but it fixed my E02 error! Wouldn't have given it a go without watching this as I am a DIY disaster. I ordered the new impeller from the link in the comments. The impeller wasn't broken, but was clearly worn in places and had discoloured due to the heat. Swapped it out and all good! Thanks!

  • @carlosfandangothe1
    @carlosfandangothe1 4 ปีที่แล้ว +5

    Hi. Thanks for posting.
    My Vegas E02 error was fixed by an impeller change.
    The impeller looked ok and the spindle was not broken, but the lower rubber cup was elongated.
    The leaks in the flow and return pipes, where they fit to the spa, were due to perished rubber washers.
    However be careful to get a 39mm inside diameter O ring for the magnetic reed switch housing.
    When I removed mine to check for debris and check it was working correctly, when refitted, it leaked due to age compression of the original o ring.
    I got mine from a car parts shop with a box of assorted o rings. It was a bit fat but works well with a bit of vaseline on it on on re-assembly.
    Good Luck. You can do it.

  • @chriswhitlock4153
    @chriswhitlock4153 3 ปีที่แล้ว +1

    Spot on Dave - followed your instructions and E02 fixed. Top Man!

  • @chrisjones8558
    @chrisjones8558 3 ปีที่แล้ว

    Thanks Dave for the great film, followed your instructions and now my spa pumps fixed!

  • @Harleyquo
    @Harleyquo 2 ปีที่แล้ว +1

    Dave just watched your video, ordered the part it came today, took me about 5 minutes to do! Used Vicks vapour rub too as it was all I had! Many thanks👍

  • @stutheurologist1
    @stutheurologist1 4 ปีที่แล้ว +4

    Dave, just wanted to say thank you for this. I have followed your video and have replaced the impeller for £12 instead of buying a new pump for 250! Thanks again. I’ll be watching your videos whenever I’m in trouble with the spa!

    • @davelewis560
      @davelewis560  4 ปีที่แล้ว +1

      Hi Stuart, thank you for your post, well done!!!

    • @warrenliddington5352
      @warrenliddington5352 9 หลายเดือนก่อน

      ​@@davelewis560hi dave, how much is a pump service kit for St Moritz?
      All removed, looks like leaking outer seal between two sections. Also play in impellor

  • @thecountsaintgermaine7937
    @thecountsaintgermaine7937 3 ปีที่แล้ว +1

    Excellent video, easy to follow and worked a treat. Thank you

  • @pomdekiwi4818
    @pomdekiwi4818 4 ปีที่แล้ว +1

    That's brilliant info mr Lewis and saved it just in case I need it. Looking forward to future tips

  • @mikethomas5794
    @mikethomas5794 3 ปีที่แล้ว +2

    Worked perfectly, thanks Dave! Took me about 45 minutes start to finish, and 10 of that was hunting for the vaseline :D I was a bit worried this wasn't the problem as the plastic shaft on my impeller was fine when I got it out but the magnet bit around it was cracked and corroded. Replacing with a new 12 quid impeller fixed it right up and it's running smooth and quiet now. Thanks!

    • @jonoble8498
      @jonoble8498 3 ปีที่แล้ว

      Where did you buy the impella pleas?

    • @davelewis560
      @davelewis560  3 ปีที่แล้ว

      @@jonoble8498 www.ebay.co.uk/itm/114329460248?hash=item1a9e911e18:g:kHgAAOSwn0dgecB0

    • @loug8364
      @loug8364 2 ปีที่แล้ว

      Hi I have gone on the link provided and I am just wondering if you deliver to France

  • @paulanderson803
    @paulanderson803 3 ปีที่แล้ว +2

    Amazing. Don’t watch any other videos about filters being blocked. Order my new impeller and it’s all sorted. Cheers Dave

  • @slawekb.8279
    @slawekb.8279 ปีที่แล้ว

    Thank you for this video - it helped me tremendously! In my case nothing broke inside the pump - it just became too entangled in some hair to move correctly.
    Thanks again!

  • @warzoneboii2693
    @warzoneboii2693 3 ปีที่แล้ว +2

    Hey dave, I followed your instructions and found it relatively easy to do. It seems to have sorted out the error 2 problem I had. Thank you so much for this video. It has saved me a right headache and money which I don't really have to buy a new one, and it is absolutely much quieter.
    You sir, I salute you, legend. 👍
    Cheers... gaz

    • @shawnmason5893
      @shawnmason5893 2 ปีที่แล้ว

      You prolly dont give a shit but does any of you know of a method to get back into an instagram account?
      I stupidly forgot my account password. I appreciate any help you can give me!

    • @holdenmilo24
      @holdenmilo24 2 ปีที่แล้ว

      @Shawn Mason Instablaster ;)

    • @shawnmason5893
      @shawnmason5893 2 ปีที่แล้ว

      @Holden Milo thanks for your reply. I got to the site thru google and im trying it out atm.
      I see it takes a while so I will get back to you later with my results.

    • @shawnmason5893
      @shawnmason5893 2 ปีที่แล้ว

      @Holden Milo It worked and I now got access to my account again. I am so happy:D
      Thanks so much you really help me out !

    • @holdenmilo24
      @holdenmilo24 2 ปีที่แล้ว

      @Shawn Mason you are welcome :)

  • @PRIMEDUDE101
    @PRIMEDUDE101 4 ปีที่แล้ว +1

    Thank you for this post. My egg pump developed a rattling sound which at 1st stopped when I gave it a whack on the side. It then became premenant and quite loud. It never stopped with an alarm etc just became really noisy. This quick fix has got it back to working at just a quiet hum. Really pleàsd with the result. Thank you again for posting Dave!!

    • @davelewis560
      @davelewis560  4 ปีที่แล้ว

      No Problem Paul, its amazing how quiet it is after the retrofit isn't it? where did you get the impeller from, did you get it from my suggested link?

    • @PRIMEDUDE101
      @PRIMEDUDE101 4 ปีที่แล้ว

      @@davelewis560 yes really quiet 🙌. Surprising how this fix to the rattling issue isn't as widely known. I didnt purchase through your link tbf - I saw in the comments that you were working on being able supply the parts but missed purchasing via the link. If this issue happens again will deffo buy from you and encourage others 👍

    • @GoldStarHoneybees
      @GoldStarHoneybees 3 ปีที่แล้ว +2

      Same here. No E02 error (I've had that before and it was solved by changing the filter), it was just noisy to beat the band. Hard to even be in the tub the noise was so loud, it made you close the bedroom window to stop hearing it at night. Found the impeller at Amazon (US - #58113) for about $11, opened up the egg, the impeller shaft itself was not broken, but the housing that contains the magnet was cracked and things were just out of round in general. I worked Dave's fix, replaced the entire impeller - now it's so quiet you have to get REALLY close and listen REALLY hard to even be sure the pump is running. Thanks, Dave!

  • @fazerphil6125
    @fazerphil6125 2 ปีที่แล้ว +1

    Thank you very much for the video. fixed my E02 error. Impeller shaft was split open and corroded.

  • @user-ru1cz4vw6b
    @user-ru1cz4vw6b 2 หลายเดือนก่อน

    I am so grateful for you taking the time to make this video! Our hot tub wouldn’t start up this week when we got it out for the summer, we were worried we’d need a whole new ‘egg’ but this video has meant I’ve been able to fix it in minutes for a fraction of the price! Weirdly our plastic bit wasn’t broken, but the replacement impeller worked so something must have been up 😂😂

    • @davelewis560
      @davelewis560  2 หลายเดือนก่อน

      Brilliant! Well done and happy Hottubbin'

  • @user-rh8fc8hd5y
    @user-rh8fc8hd5y ปีที่แล้ว

    Perfect thank you for this I thought I was going to have to but a new pump completely. Top fella

  • @JDJD-hg9hu
    @JDJD-hg9hu 2 ปีที่แล้ว

    Your a rockstar
    Thank you for the amazing video
    Just like you said my shaft cracked
    Stay happy healthy and fluid

  • @mariapistotnik907
    @mariapistotnik907 4 ปีที่แล้ว +1

    great to see these tubs can be fixed

  • @xratedmanic
    @xratedmanic 3 ปีที่แล้ว

    Would like to say thanks for this video and kit my lay z spa is now repaired and silent 👍

  • @katiedavies5286
    @katiedavies5286 4 ปีที่แล้ว +1

    Well fingers crossed this is my issue Thanks for the video! 🤞👌

  • @pamelamcd7652
    @pamelamcd7652 3 ปีที่แล้ว +1

    Perfect fix! Thanks a bunch!

  • @loug8364
    @loug8364 2 ปีที่แล้ว +1

    I have replaced the impeller (very proud of myself) thank you

  • @rhysmorris5689
    @rhysmorris5689 4 ปีที่แล้ว

    The master at work!

    • @kevinbell1352
      @kevinbell1352 4 ปีที่แล้ว

      Hi
      Any news on your kits.
      Thanks kev

  • @dawidm.bertelsen7531
    @dawidm.bertelsen7531 3 ปีที่แล้ว

    Perfect repair, it works great 👌🏻😎

  • @davelewis560
    @davelewis560  4 ปีที่แล้ว +9

    I will be putting a link on later for spares, im trying to get good prices as there's too many rubbish spares out there... watch this space!

    • @amandawood4173
      @amandawood4173 4 ปีที่แล้ว

      Hi Dave do you have the part number got the impeller as I am trying to source one for our hot tub thanks in advance x

    • @lansingschantz6853
      @lansingschantz6853 3 ปีที่แล้ว

      Hi Dave
      Can you furnish me with new parts that will work. Thanks

    • @bethannaowen5038
      @bethannaowen5038 3 ปีที่แล้ว

      Does this work without the caps at the start, we got the hot tub second hand and they binned the caps

    • @Kate-gz1io
      @Kate-gz1io 3 ปีที่แล้ว

      Hey can you send the link to order this part please thanks 🙏

    • @L10EDIT
      @L10EDIT 4 วันที่ผ่านมา

      Hi where can I get this impeller ?? I think I need a new one

  • @dannylyons824
    @dannylyons824 4 ปีที่แล้ว +1

    My bottom pipe is bent for filter to work how do you straighten it? It's right inside the inflate part itself causing bleep after 5 minutes annoying will get in touch now with lazy spa.

  • @davelewis560
    @davelewis560  4 ปีที่แล้ว +3

    Hi all my fab subscriber's, if you need any advice on on Electrical or Mechanical equipment please let me know your issue, be it Boilers, Refrigeration, Hot Tubs anything, I will guide you and try my best to sort your issue out...

  • @Max66MkII
    @Max66MkII 3 ปีที่แล้ว

    so got the dreaded E-02 done all the usual quick fixes including a descale fitted new seals etc but same issue after running it for about 10 mins where can I get the replacement impeller parts from ?

  • @davelewis560
    @davelewis560  3 ปีที่แล้ว +4

    Coming up soon, complete replacement of the lazy spa pump, I'm retrofitting the bestway pump as fed up with replacing the impeller every 2 months, watch this space :)

    • @susanswann6672
      @susanswann6672 3 ปีที่แล้ว

      Dave do you answer questions ref EO2 error just replaced impeller yesterday following your utube. It ran fine much quieter heater working. Near new filter replaced . This morning E02 code again, help

    • @davelewis560
      @davelewis560  3 ปีที่แล้ว

      @@susanswann6672 Its probably the impeller a bit stuck, its happened to me, take the pump apart and reassemble its hopefully that.

    • @Sunshine-rk6yk
      @Sunshine-rk6yk 3 ปีที่แล้ว

      Dave how do I buy a replacement impeller kit from you?????? Sallyharvey468@gmai.com

    • @danieldenis8514
      @danieldenis8514 3 ปีที่แล้ว

      Similar question, where can i order z replacement impeller ?

    • @davelewis560
      @davelewis560  2 ปีที่แล้ว

      www.ebay.co.uk/itm/114329460248?hash=item1a9e911e18%3Ag%3AkHgAAOSwn0dgecB0@@danieldenis8514

  • @MarkFarrington-nq1dp
    @MarkFarrington-nq1dp 2 หลายเดือนก่อน

    Dave many thanks your suggested fix worked well amazing thanks.

  • @Leo-gt1bx
    @Leo-gt1bx ปีที่แล้ว

    Great video thanks. I've got a customer's heating trip the mains when turned on any suggestions?

  • @garybond161
    @garybond161 3 ปีที่แล้ว +1

    Nice one Dave CHEERS :)

  • @stevegidlow5839
    @stevegidlow5839 2 ปีที่แล้ว

    thanks for the tutorial where do i get the new impellor shaft from

  • @Max-ew5kg
    @Max-ew5kg ปีที่แล้ว

    Absolute Legend!! Many thanks 👍

  • @Golfmastermen
    @Golfmastermen 3 ปีที่แล้ว

    Hi Dave love your videos can you tell me what size is the impeller for a lazy spa vegas please as I have an e02 error and need a new one or can you supply me with one

  • @davelewis560
    @davelewis560  4 ปีที่แล้ว +1

    Did you know the most common Domestic Boiler issue is with Low water pressure, if you have less than 1 Bar pressure on the gauge on your boiler then your boiler (depends on the manufacturer) will fault out, I can help by showing you how to top up your system, let me know by a like so its worth me doing a vid :)

  • @RVnld
    @RVnld 4 ปีที่แล้ว +1

    Germany. Thanks for your reply

  • @malctongue
    @malctongue 3 ปีที่แล้ว

    Hi Dave, thanks for the advice, I am just about to strip down my pump, do you still sell the spare impeller & is so how do I get one from you please?

  • @122popey
    @122popey 3 ปีที่แล้ว

    Hi Dave mate I changed my impeller due to old one cracked , I turn the new one on spins for 3 seconds then cuts out again , any ideas pal ,cheers

  • @jonstromberg477
    @jonstromberg477 3 ปีที่แล้ว

    Where can i find a new impeller for my lazy spa?

  • @StuartHough
    @StuartHough 3 ปีที่แล้ว +3

    Thank you kindly sir, turned out to be the exact problem. Shoddy plastic. Temp fix with a bamboo stick till the replacement arrives!

    • @bbhomebody
      @bbhomebody 3 ปีที่แล้ว

      THANKS FOR THE BAMBOO STICK IDEA. I was just thinking, "What could I use temporarily?"

    • @StuartHough
      @StuartHough 3 ปีที่แล้ว

      @@bbhomebody my stick is still going, never had to put the real replacement in!

    • @noraface9364
      @noraface9364 3 ปีที่แล้ว

      What kind of bamboo stick please? I think the ones I have are too thick..

  • @threecccs1
    @threecccs1 ปีที่แล้ว

    hi Dave,,,,know anything about the Heater ? when I press my heater button on a Miami it trips out my elec supply ?

  • @turnertiler
    @turnertiler 3 ปีที่แล้ว

    I have flow in out of egg. But when I turn heater on it stays on for 20 or so secs then cuts out. Eo2 error has been playing up on and off for months. Could this be the impeller also??

  • @sailingandrunning
    @sailingandrunning 3 ปีที่แล้ว +1

    Dave, thanks. It was indeed the impeller

  • @Melissapondlove
    @Melissapondlove ปีที่แล้ว

    I just bought one first pump saluspa cup holder one got error EO2 got the next pump egg one same thing do you think both could be broken like that?? They are sending me a third…. So instead of throwing them out maybe I could buy this well 2 kits !

  • @carmeltuckley7139
    @carmeltuckley7139 ปีที่แล้ว

    Is this possible for an e6 temp fault on wave hot tub

  • @christiankalambaie
    @christiankalambaie 3 ปีที่แล้ว

    How do I get this part please

  • @philwilkinsonphotographyvi932
    @philwilkinsonphotographyvi932 8 วันที่ผ่านมา

    Hi, thanks for the video, any advice, my pump seems to go for couple of secs then says EO2, much appreciated

  • @bretthudson4196
    @bretthudson4196 29 วันที่ผ่านมา +1

    What if this doesn’t fix the problem…?
    Impeller magnet was split open the length of the magnet! Thought for sure that was what it would need. Going to start opening it up again and maybe the pump gasket which was about a mm or 2 too long is causing the problem.
    Pressure switch available ?

    • @davelewis560
      @davelewis560  20 วันที่ผ่านมา

      Yes, keep trying or buy a complete new pump if required.

  • @deanbirkhead8738
    @deanbirkhead8738 3 ปีที่แล้ว

    Hi Dave. Really good video, to the point and easy to follow. I ordered an impeller as mine was showing an E02 error and descaling it made no difference. Got to the impeller and mine wasn’t broken but changed it anyway along with the supplied washers. Turned on the unit and after 60 seconds, E02 error again. Any other suggestions on what it could be, I’m at a loss now.
    Many thanks

    • @davelewis560
      @davelewis560  3 ปีที่แล้ว +2

      Sorry Dean for not getting back to you sooner, sounds like a lack of water flow, could be the pump is still not pumping or the water flow switch is defective, so with the spa only half full, turn on your egg, does water start flowing out of the top, if so then the pumps ok so its the flow sensor, you could short it out but better fitting a new one, plenty of vids on you tube to show you how, let me know how you got on mate.

  • @jakeclaassen7521
    @jakeclaassen7521 3 ปีที่แล้ว +1

    Thanks for this video mine is not even a month old and I can not get it out off the E02 error

  • @ronaldstewart8933
    @ronaldstewart8933 3 ปีที่แล้ว

    Hi Dave, I have tried to descale the pump and I have replaced all the rubber washers but the water still leaks from the descale unit and the E02 keeps coming on the egg 🤬🤬

  • @hybridav4266
    @hybridav4266 4 ปีที่แล้ว

    Hi Dave great video do you also no where I can purchase the bungs to place on the filter and flow pipes ?

    • @davelewis560
      @davelewis560  4 ปีที่แล้ว

      Hello, thank you for your kind comment, if you go on ebay and type in "lazy spa rubber stopper" you will see the black round stoppers and you'll also see the grey one for the air. Silly prices for what they are you could use a cut off from a plastic bag and elastic bands for the flow pipes, I'm fairly sure that the air one has a rubber flap so when you disconnect water shouldn't come out, again if it does rubber band and plastic bag time, just have to get someone to pull the egg away as you bung it up!!!

  • @janford8667
    @janford8667 4 ปีที่แล้ว

    Thank you for this. It was really helpful. My pump is making one hell of a noise! I've tried doing the reverse flow routine with a hose pipe. It momentarily reduced the noise (about 5 mins worth), then started again! Could this be the impeller? I would be very grateful for your thoughts.

  • @LILSPARK77
    @LILSPARK77 3 ปีที่แล้ว

    I have the dreaded E02. The seals of the a b and c were all damaged so I’ve replaced those. I’ve replaced the filters and cleaned the debris screens and did the backflow cleaning. Also cleaned that water sensor area as there was some debris. I’m only able to run bubbles. If I try to run heat or filtration the E02 code comes up. Would the impeller be the only other option? Where can I purchase one online? Thank you.

    • @davelewis560
      @davelewis560  3 ปีที่แล้ว

      Hi, it could be the 12v transformer that serves the pump but more likely to be the impeller sticking, take it apart and replace it with a new one , as per the vid, www.ebay.co.uk/itm/114329460248?hash=item1a9e911e18:g:kHgAAOSwn0dgecB0

  • @warzoneboii2693
    @warzoneboii2693 3 ปีที่แล้ว

    Awesome cheers 👍🍻👍👍👍

  • @gaylecole9726
    @gaylecole9726 4 ปีที่แล้ว

    Hi Dave where is your link to buy the replacement impeller kit as my pumps packed up.I've flooded the video my pole doesn't appear broken but the chaps are no good

    • @davelewis560
      @davelewis560  3 ปีที่แล้ว

      www.ebay.co.uk/itm/Lay-Z-Spa-Impeller-Repair-Kit-Water-Pump-Full-Set-6-SEALS/224161237771?_trkparms=aid%3D1110012%26algo%3DSPLICE.SOIPOST%26ao%3D1%26asc%3D225076%26meid%3Dc26f6af95d584c9681b8cd6f9086bc73%26pid%3D100011%26rk%3D2%26rkt%3D12%26sd%3D224092764886%26itm%3D224161237771%26pmt%3D1%26noa%3D0%26pg%3D2047675%26algv%3DPromotedSellersOtherItemsV2%26brand%3DLay-Z-Spa&_trksid=p2047675.c100011.m1850

  • @9012caz
    @9012caz 3 ปีที่แล้ว

    did you find a link for parts

  • @noraface9364
    @noraface9364 3 ปีที่แล้ว

    Please help me I've just taken it all apart and the stick is fine i don't know what to do now 😔

  • @ericamcneal2794
    @ericamcneal2794 4 ปีที่แล้ว +1

    I like the spa but I have had nothing butt problems with this pump

  • @urolas
    @urolas 3 ปีที่แล้ว

    Hi Dave got a lazy Spa Cancun tried the E02 basics but the motor for the pump isn’t kicking in at all. Which impeller do I need for the cancun or are they all the same?

    • @davelewis560
      @davelewis560  3 ปีที่แล้ว

      they all the same Urolas

  • @victorypromotion
    @victorypromotion 2 ปีที่แล้ว

    Where do you get the impeller?

  • @Elin-Esteem84
    @Elin-Esteem84 4 ปีที่แล้ว

    Hi my hot tub blows the breaker on its plug after 5 sec of being plugged in, its never done this b4, can u help me figure out what might b the problem? Ty

    • @davelewis560
      @davelewis560  4 ปีที่แล้ว

      Its more than likely a component like the heater or Pump , try to disconnect the pump, try the breaker if it still trips, try the heater ... and so on, eventually you will find the issue...

  • @brian07andrews
    @brian07andrews 4 ปีที่แล้ว +1

    Very good, are you available for a few in the Portsmouth area ?

  • @sueporter4420
    @sueporter4420 3 ปีที่แล้ว

    How can I tell if it's bad it looks ok

  • @sophiekessell9526
    @sophiekessell9526 4 ปีที่แล้ว

    If the shaft has snapped In the pump, will the bubbles still work? I’m loosing will to live with our spa. It’s eo2 error and I’ve tried everything 😩

    • @davelewis560
      @davelewis560  4 ปีที่แล้ว +1

      Hi Sophie, the way it works is when you turn the unit on, immediately the pump should start, if the pump doesn't start it could be that 1. There's no power going to the pump , this could be the Transformer or no output from the PCB, 2. If there's power going to the pump (12V AC) then the pumps defective. The unit has a flow sensor its like a little paddle sat in the water pipe, when water flows it makes the paddle go from a down like position into a horizontal position, when that paddle is in the horizontal position it makes a switch that more or less tells the PCB there's water flow, the PCB then powers up the heater and normal operation you can also then turn on the air to produce bubbles. Advise you have a qualified electrical person to check this, its not that difficult. I hope this helps.........

  • @heatherbrown6963
    @heatherbrown6963 3 ปีที่แล้ว

    Any other thoughts what it could be?..filters etc fine impellor replaced and still no luck

    • @davelewis560
      @davelewis560  3 ปีที่แล้ว

      No output from the 12V dc Transformer, loose cable connection, basically is there any noise at all from when you reset? Call me on 07837 215734 and ill talk you through some steps, but you will need to get a qualified sparks in as its quite high voltage when testing....

  • @trudimann7279
    @trudimann7279 3 ปีที่แล้ว

    I cannot find where to get the impeller from I've looked and everyone I look at is different looking for has different numbers

    • @davelewis560
      @davelewis560  3 ปีที่แล้ว

      www.ebay.co.uk/itm/Lay-Z-Spa-Impeller-Repair-Kit-Water-Pump-Full-Set-6-SEALS/224161237771?_trkparms=aid%3D1110012%26algo%3DSPLICE.SOIPOST%26ao%3D1%26asc%3D225076%26meid%3Dc26f6af95d584c9681b8cd6f9086bc73%26pid%3D100011%26rk%3D2%26rkt%3D12%26sd%3D224092764886%26itm%3D224161237771%26pmt%3D1%26noa%3D0%26pg%3D2047675%26algv%3DPromotedSellersOtherItemsV2%26brand%3DLay-Z-Spa&_trksid=p2047675.c100011.m1850

  • @bexocube
    @bexocube 2 ปีที่แล้ว

    Hi Dave do you sell the seals and propeller? If so where can I buy them (rather than get the wrong bits off eBay..) and would you recommend a metal stick in the middle or another plastic stick? Thanks

    • @davelewis560
      @davelewis560  2 ปีที่แล้ว

      www.ebay.co.uk/itm/114329460248?hash=item1a9e911e18%3Ag%3AkHgAAOSwn0dgecB0

  • @lpatterson5005
    @lpatterson5005 3 ปีที่แล้ว

    Hi great video dave!! Are all E02 errors for the same cause? I've only had mine a few weeks and its came on. The air comes out fine but its when I turn the heater on it comes on I haven't got any water in mind would that be why? It also smells of burning plastic
    Thanks in advance

    • @davelewis560
      @davelewis560  3 ปีที่แล้ว +1

      omg, it needs water mate!!

  • @TIPSANDTRICKSREALS
    @TIPSANDTRICKSREALS 4 ปีที่แล้ว

    My pump won’t kick in I get EO2 fault I’ve checked all the basic stuff , pump did sound a bit noisy before it stopped working

    • @davelewis560
      @davelewis560  4 ปีที่แล้ว

      Hi, you need to have an electrician to check if there is power going to your pump directly upon reset, you should have 12V ac at the transformer output for around 3 seconds, if you do have power on the transformer and the pump does not run or do anything then the pump is defective, if you dont have 12V then the pump maybe good, could be the transformer, or mains fuse blown, or no output from the controller, there's so many things it could be, dont try if your not qualified, the impeller change on the vid is only carried out when the unit is off and unplugged.

  • @gpux4514
    @gpux4514 4 ปีที่แล้ว

    Very good. Problem solved

  • @nigelcooper7695
    @nigelcooper7695 4 ปีที่แล้ว

    Hi Dave Very helpful video, can you tell me where you got your replacement impeller from, thanks.

    • @davelewis560
      @davelewis560  4 ปีที่แล้ว +1

      Hi Nigel, you can get the impeller and grommets here... th-cam.com/users/redirect?redir_token=QUFFLUhqa3dONFp0bHEySHdJRnFwMURfVlY0UjFxVEE5UXxBQ3Jtc0tsejZ2WGdleVJmSEVFOWI0eDZTOThWNnFSNGtuNW1VRGJtUnJUQ2FWU29xSC1zMGZWd0FEb1NXUERMTjFUTWliVEwtcWhOck1ZUEhuR25Bd05jRm1IdDQ0WTl5UVV2WmVvYXJneWVwS252SUZNQkNpQQ%3D%3D&q=https%3A%2F%2Fwww.ebay.co.uk%2Fitm%2FLay-Z-Spa-Water-Pump-Impeller-New-Fix-E02-Noisy-Pump-Issues-A-2-FREEBIE%2F254595715232%3FssPageName%3DSTRK%253AMEBIDX%253AIT%26_trksid%3Dp2057872.m2749.l2649&stzid=UgxbmoZoUg94LMgm0dF4AaABAg.99Q0kaqyeQI99QSzsC4woQ&event=comments

  • @malcolmk6025
    @malcolmk6025 3 ปีที่แล้ว

    Hi Dave, thanks for your video. I had an issue with the impeller and was able to replace using your help. This doesn't completely solve my problem though. Now it looks like I have no power getting to the pump - I have verified the pump works with an external power supply. Is it safe to simply replace the pump power supply/transformer, or is there possibly a fuse somewhere that has blown that might be causing this. Your thoughts would be appreciated.

    • @davelewis560
      @davelewis560  3 ปีที่แล้ว

      Give me a call 07837 215734

    • @malcolmk6025
      @malcolmk6025 3 ปีที่แล้ว

      @@davelewis560 Hi Dave, thanks for that option - I'm in New Zealand :-) I have done some more checking and definitely power getting to the D terminals where the pump power supply is connected so am pretty sure its the power supply thats stuffed. Just got to find a replacement now...if you have any links feel free to let me know

  • @kerrywest4103
    @kerrywest4103 3 ปีที่แล้ว

    Hi, we have the New York with an E02 error...tried everything, so am assuming its the impeller..can you recommend where to buy one please x

    • @davelewis560
      @davelewis560  3 ปีที่แล้ว

      www.ebay.co.uk/itm/Lay-Z-Spa-Impeller-Repair-Kit-Water-Pump-Full-Set-6-SEALS/224161237771?_trkparms=aid%3D1110012%26algo%3DSPLICE.SOIPOST%26ao%3D1%26asc%3D225076%26meid%3Dc26f6af95d584c9681b8cd6f9086bc73%26pid%3D100011%26rk%3D2%26rkt%3D12%26sd%3D224092764886%26itm%3D224161237771%26pmt%3D1%26noa%3D0%26pg%3D2047675%26algv%3DPromotedSellersOtherItemsV2%26brand%3DLay-Z-Spa&_trksid=p2047675.c100011.m1850

  • @amandadavey5323
    @amandadavey5323 4 ปีที่แล้ว

    Hi, I get this error code intermittently and my egg has got louder, so am going to change the impeller as you suggested how do I order this from you

    • @davelewis560
      @davelewis560  4 ปีที่แล้ว

      Hi Amanda, Ive ran out but you can get them from here www.amazon.co.uk/gp/product/B01E6V649Y/ref=ppx_yo_dt_b_asin_title_o07_s00?ie=UTF8&psc=1

  • @Fleming41st
    @Fleming41st 3 ปีที่แล้ว

    Hi Dave
    Hope your well? Were do you get them impeller part from please?
    Thanks
    James

    • @davelewis560
      @davelewis560  3 ปีที่แล้ว

      Here is the link mate www.ebay.co.uk/itm/114329460248?hash=item1a9e911e18:g:kHgAAOSwn0dgecB0

  • @RoyD2
    @RoyD2 ปีที่แล้ว

    I have changed the impeller and the flow sensor (entire pipe including sensor) but still running in E02. Any thoughts?

    • @adrianaramirez3104
      @adrianaramirez3104 ปีที่แล้ว

      I’m having the same issue, did anyone respond back to you?

  • @neilspendelow9487
    @neilspendelow9487 4 ปีที่แล้ว

    Hi Dave, I’ve got a really noisy pump. I have read that this can sometimes cause the issue, is this correct?

    • @davelewis560
      @davelewis560  4 ปีที่แล้ว

      Yes Neil, the shafts worn and causing the pump to be noisy

  • @shazess8123
    @shazess8123 3 ปีที่แล้ว

    Hi how can I order this part plz

  • @dawnpayne1298
    @dawnpayne1298 3 ปีที่แล้ว

    Hi Dave ...do you do servicing for the egg...im not brave enough to attempt to do this? cheers

    • @davelewis560
      @davelewis560  3 ปีที่แล้ว

      Hi Dawn, where abouts are you in the UK?

  • @lansingschantz6853
    @lansingschantz6853 3 ปีที่แล้ว +1

    Hi Dave,
    I've replaced the impeller, shaft and rubber bushings and still get a E02 code, Any ideas? thanks

    • @bethannaowen5038
      @bethannaowen5038 3 ปีที่แล้ว +1

      Error 2 can also be a filter issue, try changing the filter

    • @lansingschantz6853
      @lansingschantz6853 3 ปีที่แล้ว

      @@bethannaowen5038 I have thank you. Pretty sure it’s the impeller/pump issue.

    • @davelewis560
      @davelewis560  3 ปีที่แล้ว

      The flow switch may be at fault, do you get a noice from the pump as soon as you switch on?

  • @philquarmby4408
    @philquarmby4408 3 ปีที่แล้ว

    Mines not showing an error message but the unit is really loud. Any suggestions??

    • @davelewis560
      @davelewis560  3 ปีที่แล้ว +2

      Hi Phil, It will be the impeller starting to fail, the impeller rubber support ends start to wear and then the impeller starts to wobble on its axis and cause the noise.

  • @tinacollins5337
    @tinacollins5337 2 ปีที่แล้ว

    Where can I get a new impeller

  • @thenorwoodcoilektivllc4123
    @thenorwoodcoilektivllc4123 3 ปีที่แล้ว

    Where can one buy one of these from you??

  • @joecrandall8985
    @joecrandall8985 2 ปีที่แล้ว

    How do I get the parts

  • @danielbowler7709
    @danielbowler7709 2 ปีที่แล้ว

    Do you have a link to the impeller?

  • @RVnld
    @RVnld 4 ปีที่แล้ว +2

    Great video. Do you have the link where we can buy these spare parts, please? Do you use a stainless steel shaft?

    • @davelewis560
      @davelewis560  4 ปีที่แล้ว

      Hi RV, Link here..... and yes stainless steel shaft recommended...… www.ebay.co.uk/itm/Lay-Z-Spa-Water-Pump-Impeller-New-Fix-E02-Noisy-Pump-Issues-A-2-FREEBIE/254595715232?ssPageName=STRK%3AMEBIDX%3AIT&_trksid=p2057872.m2749.l2649

    • @daniellemiller4075
      @daniellemiller4075 4 ปีที่แล้ว

      Where are you based please ?

    • @RVnld
      @RVnld 4 ปีที่แล้ว

      @@daniellemiller4075 Germany. The seller in the link doesn't ship to Germany

    • @davelewis560
      @davelewis560  4 ปีที่แล้ว

      @@daniellemiller4075 Hi, we are based in Portsmouth

    • @davelewis560
      @davelewis560  4 ปีที่แล้ว

      @@daniellemiller4075 in Portsmouth and South Wales

  • @davelewis560
    @davelewis560  4 ปีที่แล้ว

    Do you all know what Chemicals to use in your now working hot tub? And where to buy?

    • @fredhollis3749
      @fredhollis3749 3 ปีที่แล้ว

      Hi Dave. Do you think this tub can use salt instead of chlorine? Thanks

  • @azadazady8360
    @azadazady8360 15 วันที่ผ่านมา

    Thanks

  • @peterspage997
    @peterspage997 4 ปีที่แล้ว

    Do you know where I can get the gasket that fits on the underside of the screw for the filter housing cover? It can't be that a n expensive spa is dependent on a £2.00 rubber gasket!!!

    • @davelewis560
      @davelewis560  4 ปีที่แล้ว

      Sorry, not sure I know which one, can you provide more info?

    • @peterspage997
      @peterspage997 4 ปีที่แล้ว

      The filter housing is held on by a large plastic screw for want of a better description. On the threaded side there is a black rubber gasket which I assume is there to form a vacuum seal of some sort. This is the filter housing that fits inside the spa itself. It's that rubber gasket that im looking for. Thanks

    • @davelewis560
      @davelewis560  4 ปีที่แล้ว

      @@peterspage997 Hi Peter, do you mean these rubber gaskets, if so heres where to get them... www.ebay.co.uk/itm/Lay-Z-lazy-Spa-pump-B-C-coupling-water-rubber-seal-x-2-new/264443259832?hash=item3d920bebb8:g:tvUAAOSw-2xe3Wo-

    • @peterspage997
      @peterspage997 4 ปีที่แล้ว

      Dave Lewis not those gaskets it’s the one on the underside if that big screw on the filter housing. The housing fits inside the spa in the water

    • @peterspage997
      @peterspage997 4 ปีที่แล้ว

      It’s the rubber seal on that big grey screw fitting

  • @tonyfisher6959
    @tonyfisher6959 3 ปีที่แล้ว

    How do I order from you and how much please thanks

  • @rosiejames1672
    @rosiejames1672 3 ปีที่แล้ว

    Hi have you got an up to date link for parts?

    • @davelewis560
      @davelewis560  3 ปีที่แล้ว

      www.ebay.co.uk/itm/114329460248?hash=item1a9e911e18:g:kHgAAOSwn0dgecB0

  • @daynacousins281
    @daynacousins281 3 ปีที่แล้ว

    Hi this sounds great. Could you give me a link for the right part to buy as there's so many I have no idea. Thank you in advance x

    • @davelewis560
      @davelewis560  3 ปีที่แล้ว

      Hi Dayna, this is a link for the impeller. www.ebay.co.uk/itm/114329460248?hash=item1a9e911e18:g:kHgAAOSwn0dgecB0

    • @jaymcpherson3645
      @jaymcpherson3645 3 ปีที่แล้ว

      @@davelewis560 hi there question my lazy spa model number 14133 and drain the other day filled it turned it on ran half day got that error code check all filter and did every suggested rest the pump turned on ran got about 88 degrees and error code aging just kinda wonder your thoughts it's water flow but can't find where thanks

  • @yoannap.3766
    @yoannap.3766 4 ปีที่แล้ว

    Hi Dave great video no bullshit straight to the point.
    I wonder if I could ask you a question on tap into your knowledge? I have a lazy z spa Miami. That started to Trip the RCD I have eliminated a few problems i.e. it’s not the pump that Tripping it out, but something to do with the heating side it only trips around the temperature set and not before.
    So the element is working fine I think (I haven’t stripped it down yet) but maybe something to do with The thermostat side??

    • @davelewis560
      @davelewis560  4 ปีที่แล้ว

      Hi Yoanna, thank you for your comments, there could be an earth leakage or it could be a defective heater or even a defective RCD, its difficult to say, I would personally check the amps drawn on the live cable on the heater with an amp clamp, its a 2kW heater, so using the power formula to find the correct Amps it should draw when running on heating is...……...P/V= I (P is for Power = 2000W - V is for Voltage = 240V and I is for Amps = 8.3A
      How that was worked out is a follows, 2000/240 = 8.3 Amps, you'll need a qualified electrician to check the current draw when the heater is on, then if its only around 8.3A, ISOLATE THE POWER SUPPLY and then have him disconnect the neutral at the heater and check the live connection that's still on the heaters connection (with a multimeter set on continuity) check between that live connection and a good proven earth point on the unit itself. if you pick up a reading then there's an earth fault on the 2kW heating element, you could even have him check the resistance of the heating element with the power off, can you work what the resistance should be, use this formula V/I= R V= Volts I = Amps = ? Ohms, as said do not do the physical testing yourself unless you are competent in electrics!!!!!! The resistance of the heating element should be _ _ . _ Ohms? Also make sure no cables are shorting out or getting wet when its running.

    • @yoannap.3766
      @yoannap.3766 4 ปีที่แล้ว

      Dave Lewis
      Thank you so much Dave, my neighbour as just qualified as an electrician it would be a great experience for him to do 😀

    • @yoannap.3766
      @yoannap.3766 4 ปีที่แล้ว

      I will pass on the information to him, it will be a great help for him. Thanks again 👍

    • @davelewis560
      @davelewis560  4 ปีที่แล้ว +1

      @@yoannap.3766 Have him post on here if he is stuck.

    • @davelewis560
      @davelewis560  3 ปีที่แล้ว

      @@yoannap.3766 How did he get on?

  • @roseyfield8746
    @roseyfield8746 3 ปีที่แล้ว

    How do I buy one of these from you please