RV TIPS: Atwood/Dometic Water Heater Issue

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 ส.ค. 2024
  • SIMPLE INEXPENSIVE FIX if your Atwood/Dometic water heater isn't working on electric or gas & if it's not the board that went bad (which would be a far more expensive fix).

ความคิดเห็น • 96

  • @daleswindler
    @daleswindler หลายเดือนก่อน

    My thermal switch was not bad, but in checking it I found that the wire on the other side of the thermostat was disconnected. Thanks for your video. It helped me understand the system and consequently found the loose connection.

    • @missionrvservices
      @missionrvservices  หลายเดือนก่อน

      Glad it helped and that you ended up resolving your issue!

  • @chichirodriguez9363
    @chichirodriguez9363 7 หลายเดือนก่อน

    One of the better videos. Simple part. After getting light, I went to work with the shop vac.

  • @ddmacrae
    @ddmacrae 6 หลายเดือนก่อน

    Great video and information. This was exactly what my problem was. I would have been chasing my tail for a while if I hadn't come across this.

  • @panaproducts3988
    @panaproducts3988 5 หลายเดือนก่อน

    Great video Drew... thanks for the straight forward and easy-to-understand video!

  • @barbaracox3119
    @barbaracox3119 ปีที่แล้ว

    Thanks I'm headed to get 2 now, I feel pretty lucky this is the first time and I've lived in mine full time since 2017

    • @MrAbsentdriver
      @MrAbsentdriver 4 หลายเดือนก่อน

      This is the fix for my 2018 flying house home. Thanks for your help

  • @joshcerasale9502
    @joshcerasale9502 9 หลายเดือนก่อน

    Really appreciate you making this video! Saved my camping trip.

    • @missionrvservices
      @missionrvservices  9 หลายเดือนก่อน

      So glad to hear that!

    • @joshcerasale9502
      @joshcerasale9502 9 หลายเดือนก่อน

      First world problems hahaha. Camping without hot water, happy wife happy life.

  • @chicagochris1988
    @chicagochris1988 3 หลายเดือนก่อน +1

    I haven’t even had my new camper two weeks and used the hot water maybe 5 times. Today no ignition and electric hot water wouldn’t work either. Removed the thermal fuse plugged it right into the board and everything is working perfect again. Ordered a pack on Amazon should be here next week. Until
    Then I bypassed it

  • @6awww
    @6awww 6 หลายเดือนก่อน

    Exactly the solution I needed. Thanks for the helpful video!

  • @rongray4118
    @rongray4118 8 หลายเดือนก่อน +2

    You just have to love a company that manufactures a water heater that has T&P ABOVE the propane regulator/inlet tube... knowing it will eventually leak directly onto the assembly. This little drip fouls the controls on the propane regulator, drips on the wiring and fuse, etc., etc, - so stupid of a design a Kindergartener could do a better design...why am I saying all of this? Because the drip fouled out the propane regulator on the Jayco Jayflight LOFT that we have... between the manufacturer and parts suppliers - none of these RV's are worth what we are all baring the price we are paying for them...

  • @edwinroldan8239
    @edwinroldan8239 ปีที่แล้ว +1

    Thank you for the video. I just fixed mine!

  • @MrChiefy420
    @MrChiefy420 7 หลายเดือนก่อน

    Have the same issue. Water heater is only 6 mo. old used 2 times and Quit 2nd day on a week long trip. So far everything has power and no fuses blown so i will do that test next. What volt meter do you use? I like the one you have. Best video I've seen on this issue.

  • @lundworks9901
    @lundworks9901 19 วันที่ผ่านมา

    Thermocoupler, igniter test perfectly, still tries to ignite 3 times, blows the fuse.
    Neither gas nor electric will ignite.
    Parts replaced, still the same .

  • @OurSecondLife
    @OurSecondLife ปีที่แล้ว

    Another outstanding tip!

  • @XqeDiosxqe
    @XqeDiosxqe หลายเดือนก่อน

    Short and simple.

  • @alanshaw4655
    @alanshaw4655 ปีที่แล้ว +1

    ran the multi-meter on my thermal fuse, as i guesses b4 i watched this video, sure it enough, it tested bad. although you said NOT to do the by-pass to get it working ?, i did hook the wire straight to the thermstat board, just to see if it was indeed the fuse ?, sure enough, i turned the water heater switch on, within 3 sec's it lit the water heater as normal, guess these fuses are cheap crap from china ?, my hot water heater has not been ran much at all ! ( 2015 camper ), and now i went on a weekend trip, come to find out the water heater would not light at all. checked all the fuses cept the thermal fuse outside like you did in this video, sure enough, it tested bad. JUST TO BE SURE ?!..i hooked the wire straight to the thermastat ( yes..i know you said do not do it ?, but i wanted to be 100% sure it was just this fuse ), sure enough, the water heater worked like it was suppose to do will be headed to rv place to grab some extra fuses !!. great video !!!.

  • @shaevandetvort7732
    @shaevandetvort7732 5 หลายเดือนก่อน

    Will i still hear the clicking of the ignitor if this is the problem or would that be dead also?

  • @vincentsaunders8935
    @vincentsaunders8935 หลายเดือนก่อน

    I replaced the thermal switch and I hear a bussing sound and the tick tick sound. Then the flame comeson and then goes out! ???????

    • @missionrvservices
      @missionrvservices  หลายเดือนก่อน

      @@vincentsaunders8935 sounds like it may be a bad igniter/flame sensor.

  • @michaelblock4279
    @michaelblock4279 3 หลายเดือนก่อน

    Hello, great video! I can hear my Atwood sparking to fire but then I hear a boom and see blue flames coming out of the vent. Sometimes my hot water heater fires just fine but seems like it's inconsistent. The loud boom with the blue flames coming out of the vent tells me maybe my igniter is going bad. Please help!

    • @missionrvservices
      @missionrvservices  2 หลายเดือนก่อน

      Sounds like you may have a blockage in your flue tube or in your gas supply tube.

  • @Leeryannavy
    @Leeryannavy 7 หลายเดือนก่อน

    The thermal fuse will blows a few minutes after turning the hot water on; I’ve replaced two so far

  • @denniscorbello2037
    @denniscorbello2037 10 หลายเดือนก่อน

    Thank you this is good to know

  • @mychannelsirr
    @mychannelsirr 20 วันที่ผ่านมา

    do these water heater switch off when it gets to hot temp

  • @KennethSmith-kk1tb
    @KennethSmith-kk1tb 10 วันที่ผ่านมา

    I have continuity threw my Thermo switch! what next please

    • @missionrvservices
      @missionrvservices  10 วันที่ผ่านมา

      @@KennethSmith-kk1tb
      may have a bad board

  • @henrysanabria8507
    @henrysanabria8507 3 หลายเดือนก่อน

    Thanks you are very kind

  • @babyfaceglobal-poweredbyro1659
    @babyfaceglobal-poweredbyro1659 ปีที่แล้ว

    Hi there. I have a 1988 American Appliance brand 6 gallon hot water heater that won’t fire up on gas or electric. Would the fix you showed in this video possibly fix mine, or could you please point to a video about my brand specifically? Thanks in advance and sure appreciate all the knowledge you’re sharing!!!

    • @missionrvservices
      @missionrvservices  ปีที่แล้ว +1

      First off, what a great run for that water heater! 35 years? Wow!
      American was bought by Suburban which is different manufacturer than the one from the video. Without being there to diagnose your water heater, it’s hard to say what may be wrong. You can still get some
      Parts for these units but you would have to reach out to Suburban directly to cross reference. Wish we could be more helpful!

  • @vickidamron
    @vickidamron 4 หลายเดือนก่อน

    Thanks for info but my 2amp fuse on the solid state board keeps blowing any suggestions?

    • @missionrvservices
      @missionrvservices  4 หลายเดือนก่อน

      Unfortunately it sounds like you have a bad board 😞

  • @Hugo-Hernandez
    @Hugo-Hernandez ปีที่แล้ว +1

    Great video, did you get certified at the NRVTA ? If you did, do you recommend them ?

    • @missionrvservices
      @missionrvservices  ปีที่แล้ว +3

      Yes I did and Yes I do! One of the best decisions I've ever made! The training and the post grad community is second to none!

    • @Hugo-Hernandez
      @Hugo-Hernandez ปีที่แล้ว

      @@missionrvservices
      Thank you for your response

  • @cody5591
    @cody5591 5 หลายเดือนก่อน

    Where do I get the thermal switch?

  • @noahmclaughlin3005
    @noahmclaughlin3005 4 หลายเดือนก่อน

    If the propane works, but electric doesn’t- will it be another problem then?

    • @missionrvservices
      @missionrvservices  4 หลายเดือนก่อน

      If electric doesn’t work, it could be the electric relay in the back, it could be a circuit breaker in your circuit breaker box, it could be a loose wire, it could be a bad electric element, or even a faulty switch. You have to follow the power with your volt ohm meter.

    • @missionrvservices
      @missionrvservices  4 หลายเดือนก่อน

      If you need a tech, to find one in your area, go to MyRvResource.com

  • @josephcandela7628
    @josephcandela7628 ปีที่แล้ว

    Thanks. i have a 2015 grand design 5th wheel electric will not turn on to heat water gas works great. What do you think could be the problem?

    • @missionrvservices
      @missionrvservices  ปีที่แล้ว

      Could be a bad board or temperature sensor or a bad ECO switch or as simple as a bad water heater element.

  • @np805smith3
    @np805smith3 9 หลายเดือนก่อน

    Great Advice

  • @kat2533
    @kat2533 หลายเดือนก่อน

    Is there supposed to be water in the pipe that ignites??

    • @missionrvservices
      @missionrvservices  หลายเดือนก่อน

      @@kat2533 no.

    • @kat2533
      @kat2533 หลายเดือนก่อน

      @@missionrvservices and if there is?

  • @alanparker7473
    @alanparker7473 9 หลายเดือนก่อน

    Drew I have the same Atwood water heater in my Discovery 40E...My electric heat is working and the gas is not working...any ideas?

    • @missionrvservices
      @missionrvservices  9 หลายเดือนก่อน

      If it is trying to ignite at the water heater on gas but is not, it could be an igniter/flame sense issue, not enough spark to ignite. Could also be a gas delivery issue. Check your propane tank, also check to see if you smell gas when the heater is trying to light. If you need a tech go to the RVTAA.org

  • @daniverson4592
    @daniverson4592 11 หลายเดือนก่อน

    I replaced the thermal switch and the motherboard twice. The gas unit will start and then extinguishes after several seconds. It repeats this three times and then shuts down. What are the next steps in trouble shooting the problem? The unit is a new one on a 21 nexus rebel.

    • @missionrvservices
      @missionrvservices  11 หลายเดือนก่อน

      Sounds like a bad thermal couple/igniter. Sounds like it’s not sensing the flame.

  • @JorgeJimenez-pv4dy
    @JorgeJimenez-pv4dy 9 หลายเดือนก่อน

    I have an Atwood water heater, it turns on for 3 minutes and then turns off. What do you think the problem is?

    • @missionrvservices
      @missionrvservices  9 หลายเดือนก่อน

      Could be one of a few items. My first inclination would be you have a faulty igniter/flame sense. Reads for a minute or two then tells the board there is no flame. Could also be a faulty temp switch or eco. You need to check those with your multimeter. That’s the areas I would start. But first clean your igniter with some light sandpaper or scotch bright and see how it goes. If you need a tech, head to the RVTAA.org to find one near you.

  • @fidenciovalle5882
    @fidenciovalle5882 10 หลายเดือนก่อน

    So my heater/fire tube is igniting but not getting any hot water to the shower.

    • @missionrvservices
      @missionrvservices  10 หลายเดือนก่อน

      Are you getting hot water to anywhere else?

  • @RPO6464
    @RPO6464 ปีที่แล้ว

    My Atwood gch10a-4k doesn’t heat my water in electric or gas mode. The gas comes on for a second and then shuts off. After two cycles it won’t come on anymore. Is the fuse the same issue for me?

    • @missionrvservices
      @missionrvservices  ปีที่แล้ว +2

      No. If it was the fuse, it wouldn’t ignite at all. Sounds like you have an ECO (emergency cut off) issue, a thermostat issue or a bad board. Hard to know without being there. You’d need to put a volt ohm meter on it to check for both 12 volt DC and 120 volt AC. Follow the electric from beginning to end.

  • @peggymcmanis5731
    @peggymcmanis5731 5 หลายเดือนก่อน

    How can I test the switch so I know if electric is getting power to board

    • @missionrvservices
      @missionrvservices  5 หลายเดือนก่อน

      There's a relay next to the water heater element that you have to check. You check for power there and at the water heater element by setting your volt meter to AC. You're looking for 120v AC.

  • @user-cj7zy1vn6o
    @user-cj7zy1vn6o ปีที่แล้ว

    my atwood water heater is runing at about 170 deg. how can i turn temp down .also the presure relief valve is dripping even the new replacement one

    • @missionrvservices
      @missionrvservices  ปีที่แล้ว

      1. Factory preset on an Atwood is 140 degrees and that setting is non-adjustable. The emergency cut-off for an Atwood is 180 degress, so as long as that temperature is between 140-179 degrees, it's operating at normal range with no way to adjust it down. 2. Pressure relief valve - did you just replace it or has it been a while? Minerals can get in there even after a month. Did you do a thorough cleaning of the tank before installing the valve? Hard water can stick those open, but it is possible that you have a defective new valve. You can try tapping the end of it to see if it reseats. Hard to say more than that without being there. You can find a qualified tech near you at RVTAA.org.

  • @33Bigdogyears
    @33Bigdogyears ปีที่แล้ว

    I know you said not to run the unit without the thermal switch but can you remove it then plug straight in just to see if the switch is bad if I don’t have a meter to check the switch?

    • @missionrvservices
      @missionrvservices  ปีที่แล้ว

      Though you could check it that way We can’t recommend that you check it that way, since we don’t know what caused it to fail.

    • @33Bigdogyears
      @33Bigdogyears ปีที่แล้ว

      Guess I need to get a mobile repair guy out here to check things out. Mine isn’t working on gas or electric

    • @missionrvservices
      @missionrvservices  ปีที่แล้ว

      @@33Bigdogyears could be a board or a thermostat issue. RVTAA.org has a tech locator for your area.

  • @Maddielove2468
    @Maddielove2468 11 หลายเดือนก่อน

    We have a 2019 jayco north point. We just replaced our thermal fuse a month ago and it’s been working great since we replaced it. Now it won’t light or tick at all. Tried a new replacement fuse and nothing. Not sure what else could be wrong. There’s a brown wire that connects to the thermal fuse. Could that have gone out?

    • @missionrvservices
      @missionrvservices  11 หลายเดือนก่อน

      Could be that the igniter is bad. Could be a bad thermostat or bad ECO (Emergency Cut Off) which is right by the thermal fuse.

    • @Maddielove2468
      @Maddielove2468 11 หลายเดือนก่อน

      @@missionrvservices thank you. How can I figure out what part has gone bad without replacing everything. Either ignition or electrical board?

    • @missionrvservices
      @missionrvservices  11 หลายเดือนก่อน

      @@Maddielove2468 Use a mulitmeter to check for continuity on the thermostat or ECO. If you don't have one, you can order one from Amazon (our affiliate link) here: amzn.to/45U9K4u. There's no real way to check the board though.You have to follow the flow of power to see where it's going bad. Also, Keep in mind that there's a chance that the thermal fuse, although new, could have gone bad again.

    • @missionrvservices
      @missionrvservices  11 หลายเดือนก่อน

      In case you need a tech to come out, visit RVTAA.org and put in your city to find a certified tech in the area.

  • @wheretheskygrows
    @wheretheskygrows ปีที่แล้ว

    I can't remove the thermal cutoff fuse. How hard do I need to pull?

    • @missionrvservices
      @missionrvservices  ปีที่แล้ว

      You have to hold one end with a pair of needle nose pliers and then pull the other end with another pair of needle nose pliers to separate it at the connectors. Do that for both ends. Good luck.

  • @scottmathewson9540
    @scottmathewson9540 10 หลายเดือนก่อน

    My gas fire lights but goes out after 5-10 seconds. Also no electric water heater. Any suggestions??

    • @missionrvservices
      @missionrvservices  10 หลายเดือนก่อน

      Possible bad ignitor/thermocouple

  • @nightryder1227
    @nightryder1227 10 หลายเดือนก่อน

    Hi my Atwood water heat in my class A will not keep the water hot. It kicks on runs a while then stops working. Do you have any suggestions. I did take some of the connections lose and cleaned them. Thanks

    • @missionrvservices
      @missionrvservices  10 หลายเดือนก่อน +1

      Are you getting any hot water? Is it hot then goes cold quickly?

    • @arnulfotrujillo5570
      @arnulfotrujillo5570 3 หลายเดือนก่อน

      Bad thermocouple

    • @nightryder1227
      @nightryder1227 2 หลายเดือนก่อน

      Yes it fills up the bath sink and then goes cold.

  • @user-il8ed1el4b
    @user-il8ed1el4b 11 หลายเดือนก่อน

    This thermo switch works like a fusible link?

  • @waynerobinsonwcsd
    @waynerobinsonwcsd 10 หลายเดือนก่อน

    What about when gas is working-but electricity is not?

    • @missionrvservices
      @missionrvservices  10 หลายเดือนก่อน

      Your start following the flow of electricity. Do you have power at the element (check with multimeter)? If yes, do you have good resistance at the element? If it’s not the element where the problem is, it could be a bad relay or a faulty board at the 120v side.

  • @Bobodeman
    @Bobodeman ปีที่แล้ว

    Are you located in Australia by any chance?

  • @TomasFlores-gm8xq
    @TomasFlores-gm8xq 2 วันที่ผ่านมา

    flame is not blue. it needs to be blue. something important that should be noted. and your are not back in business.

  • @kennethweatherford9172
    @kennethweatherford9172 ปีที่แล้ว

    Why is my water 💦 heater putting of a smut it did not do this before I cleaned it it had a blown fuse link that comes from the board so I bye passed it and it worked but I did notice more shutting then it was before

    • @missionrvservices
      @missionrvservices  ปีที่แล้ว

      Not sure what “smut” is. Maybe there is something in the burn tube. Spider webs? Acorns? Dauber nests? Bugs?