Blocked Plate Heat Exchanger (Sludge) | No Hot Water | How To Unblock | Viessmann Boiler

แชร์
ฝัง
  • เผยแพร่เมื่อ 29 พ.ย. 2024

ความคิดเห็น • 93

  • @assistantto007
    @assistantto007 ปีที่แล้ว +4

    Do you have to be gas safe registered to undertake that task?

    • @GasTraining
      @GasTraining ปีที่แล้ว +6

      Gas safe to touch the boiler components my friend. Don’t play with gas if you ain’t gas safe.

    • @dylanbrandley7888
      @dylanbrandley7888 ปีที่แล้ว +3

      Gas safe as soon as you open the combustion chamber!

    • @assistantto007
      @assistantto007 ปีที่แล้ว +2

      @@dylanbrandley7888
      OK, does that mean the water side of the boiler (& the electronics) can be serviced by non gas safe engineers ?

    • @ranat5526
      @ranat5526 ปีที่แล้ว

      ​@@assistantto00730 years ago I became a corgi registered gas engineer, 70% of the people on the course were duffer's!

    • @500bht
      @500bht 11 หลายเดือนก่อน +7

      No gas safe needed as you own the boiler it's your property so do what you like to it

  • @Carl-re6zb
    @Carl-re6zb ปีที่แล้ว +3

    Great vid for anyone wanting to gain confidence in boiler repairs.

  • @marcush6139
    @marcush6139 ปีที่แล้ว +2

    I will say karma I do enjoy your videos as a new engineer is help me out greatly. The only thing I will say you make it look so easy because you do all your jobs one-handed where I struggle with two lol. Roll on the next video

  • @ronalynaguipo9666
    @ronalynaguipo9666 5 หลายเดือนก่อน +2

    What chemical you have used sir? Thank you for sharing

  • @ArifPolicewala
    @ArifPolicewala 7 หลายเดือนก่อน +2

    That is a top in depth video as usual❤

  • @SuperVitz
    @SuperVitz 14 วันที่ผ่านมา +2

    I just did this a few weeks ago on a newer Viessmann. I'm not gas safe, but I am a competent engineer and will be getting someone out to do a gas safety check. I used central heating cleaner and left it in the heat exchanger for a few hours, took multiple flushes with hot water and shaking the plate to get it clean. In theory this should never block if there is a magnet filter and inhibitor chemicals in the water right? It would've been nice if you added some inhibitor at the end.

  • @dylanbrandley7888
    @dylanbrandley7888 ปีที่แล้ว +1

    Some of the things you do whilst holding a camera, sick 👍

  • @madmaycon2531
    @madmaycon2531 9 หลายเดือนก่อน

    Your videos are very good, they are very helpful, especially for new qualified gas engineers like me.
    Thank you so much !!!

  • @rm-mastering
    @rm-mastering ปีที่แล้ว +1

    Great video and yes top marks for one handed work 🏆

  • @cliverice5651
    @cliverice5651 5 หลายเดือนก่อน +2

    Thank you for a very informative video. What brand of spirit of salts do you use please? Thank you. Very best wishes Clive

    • @dreamkiss
      @dreamkiss 11 วันที่ผ่านมา

      I was also looking for what has he used what chemical is this?

  • @yotissp
    @yotissp วันที่ผ่านมา

    Does the heat exchanger self locate pipes to holes?

  •  5 หลายเดือนก่อน +1

    Iv heard you can use brick cleaner.?

  • @muhammadAli-kd2zp
    @muhammadAli-kd2zp ปีที่แล้ว +1

    Thank you for your time to share with us . Great job 👏

  • @abdulaziz-pb5ni
    @abdulaziz-pb5ni ปีที่แล้ว +1

    I watch all Ur videos they are good and top engineer. Can you do one doing right hand blocks and left blocks repairs

  • @paulhealey2984
    @paulhealey2984 17 วันที่ผ่านมา +1

    Where did you get the spirits of salts? Thanks.

  • @rickd6421
    @rickd6421 ปีที่แล้ว +1

    Great video mate. I wouldn't be able to film and work with 1 hand so great work :) If the plate hex seals feel and look smooth and not perished, do you just leave originals in when reinstalling plate hex?

    • @advancedboilertraining
      @advancedboilertraining  ปีที่แล้ว

      Haha! So I always try to change the seals when I can, but if I don’t have any in the van and they seem to be in good condition then I’ll leave them

  • @freddyc_1
    @freddyc_1 2 หลายเดือนก่อน

    Do you do repair work at all? I'm looking for a plumber for my HIU

  • @LaurieAlfonso
    @LaurieAlfonso 10 หลายเดือนก่อน

    Helpful video! If you find that the air valve on the expansion tank leaks out some water when you go to charge it, is that a problem or a sign of a faulty tank?

    • @davelaye7003
      @davelaye7003 10 วันที่ผ่านมา

      a lot of the time its not a fault but condensate from compressed air. viessmann put the valve in a stupid place. like the rest of their boilers' badly designed and piece of shit.

  • @alihapali
    @alihapali 6 หลายเดือนก่อน

    Any chance we can fit a filter somewhere to stop this blocking mine gets blocked every week even we powerwashed it

  • @tomdutton4673
    @tomdutton4673 ปีที่แล้ว +2

    What spirit salts do you use ?

  • @bluedwarf8858
    @bluedwarf8858 ปีที่แล้ว +3

    Did you have to use new o rings on the plate heat exchanger

    • @kevinschoales844
      @kevinschoales844 ปีที่แล้ว +1

      Not sure if he showed whether he cleaned the seals up or replaced them, allways good idea to have replacement seals. & they can fall off !

  • @richardhodgson7443
    @richardhodgson7443 ปีที่แล้ว +1

    Will the plate only go in one way? Cheers

  • @christophersherratt7299
    @christophersherratt7299 9 หลายเดือนก่อน

    What is spirit salts

  • @andrejrockshox
    @andrejrockshox ปีที่แล้ว

    what is the price of new plate?

  • @shafiqmustafa2777
    @shafiqmustafa2777 8 หลายเดือนก่อน

    I have the problem, will need to buy a new plate, £160 + labour cost, do you work in London

  • @msangwan7
    @msangwan7 ปีที่แล้ว +1

    Hi thanks for video. Do you find this PHE blockage on central heating close loop side or cold to hot fresh water side also. Can this unblocking be done on fire main heatexhanger side. does main HE ever get blocked providing there is an inhibitor in the close loop?

    • @advancedboilertraining
      @advancedboilertraining  ปีที่แล้ว

      So usually the blockage is on the CH side of the plate. I’ve never seen the HW side blocked up
      So yeah, if the system is really dirty then the main heat exchanger can also get blocked

    • @davelaye7003
      @davelaye7003 10 วันที่ผ่านมา +1

      always on the hot water side here in London. its thew calcium carbonate build-up that stops heat transfer, the harder the water area, the more common this is.

  • @raj080288
    @raj080288 7 หลายเดือนก่อน

    If there is a pin hole and you say the pressure in the boiler will always be going up, would that be when the heating is on or even without the heating being turned on?

    • @davelaye7003
      @davelaye7003 10 วันที่ผ่านมา

      at all times

  • @juniorjassal1995
    @juniorjassal1995 ปีที่แล้ว

    Would you always replace the 4 o-rings on the manifolds when taking out the plate?

    • @Dee-iy4ot
      @Dee-iy4ot 8 หลายเดือนก่อน

      no

  • @vladimird3575
    @vladimird3575 ปีที่แล้ว +1

    What chemical do you use to clean it?

  • @damiebgibbons5710
    @damiebgibbons5710 ปีที่แล้ว

    Morning great video , have a problem like yours , the thing with my vessmann is that the boiler is not firing on hot water, there is a full flow out of the hot tap , checked the 3 port vale and it is moving freely, could it be a stat or the heat exchanger thanks

    • @Dee-iy4ot
      @Dee-iy4ot 8 หลายเดือนก่อน

      not firing, is nothing like the problem in this video!!

    • @davelaye7003
      @davelaye7003 10 วันที่ผ่านมา

      the hall sensor

  • @Dee-iy4ot
    @Dee-iy4ot 8 หลายเดือนก่อน

    good info , = = = however spirit of salts ( Hydrochloric acid** ) = = = = is too harsh for stainless or alloy ( **Thats why they get pin holed ) . Use a regular kettle descaler instead. and flush both direction with water

  • @thebigblackguy
    @thebigblackguy ปีที่แล้ว

    Thanks for this. Subscribed 👍🏾

  • @mikegallagher2107
    @mikegallagher2107 ปีที่แล้ว +1

    great content i use this method as well 👌👊

  • @nipperh2o925
    @nipperh2o925 ปีที่แล้ว +1

    Great tips

  • @sharazali-tabassam3033
    @sharazali-tabassam3033 ปีที่แล้ว +1

    Good video 👍

  • @kovacstamas7332
    @kovacstamas7332 11 หลายเดือนก่อน

    Good job. Thank you. That was the soultion for me.

  • @joshd790
    @joshd790 ปีที่แล้ว +1

    Good video mate shame it was a only a 7 minute one

  • @digitaria
    @digitaria 2 หลายเดือนก่อน

    I didn’t see a filter and the discharge bottle wasn’t primed, apart from that great job.

  • @jockster5525
    @jockster5525 ปีที่แล้ว +1

    Nice job mate 👍

  • @jorgetristany
    @jorgetristany 8 หลายเดือนก่อน

    Name of liquid to clean the exchanger?

  • @karlsanderson8127
    @karlsanderson8127 7 หลายเดือนก่อน

    I need to do this on my glow worm the part was only £40 so going to give it ago changing it

  • @marty3553
    @marty3553 2 หลายเดือนก่อน

    Where to get spirits of salts ?

  • @DaveInBridport
    @DaveInBridport ปีที่แล้ว +1

    That HCl is evil stuff! Need to be SO careful.

  • @dreamkiss
    @dreamkiss 11 วันที่ผ่านมา +1

    Does anyone what chemicals have been used?

    • @advancedboilertraining
      @advancedboilertraining  11 วันที่ผ่านมา +1

      Spirits of salts

    • @dreamkiss
      @dreamkiss 11 วันที่ผ่านมา

      @@advancedboilertraining thanks just had a look Selco sells this only a few pounds.

  • @marcjohndavies8244
    @marcjohndavies8244 5 หลายเดือนก่อน

    Is it legal to flush that down the drain???

    • @kirren79
      @kirren79 5 หลายเดือนก่อน

      If it's a soak away drain, that's really not good for the environment, standard drain it's okay, personally I would just fit a new plate and have old plate recycled. Plus it a lot safer, did you hear him cough due to the flumes 😷

  • @andrewhull6776
    @andrewhull6776 ปีที่แล้ว

    Smart guy

  • @trevjones4564
    @trevjones4564 ปีที่แล้ว

    Thanks top video

  • @mcDarkD
    @mcDarkD 4 หลายเดือนก่อน

    a ballfix valve to fill the boiler no checkvalve. i do wonder why the plate was that clogged. not. why am i not surprised..

  • @ozwellalford5015
    @ozwellalford5015 ปีที่แล้ว +1

    Nyc Job

  • @cippollino83
    @cippollino83 ปีที่แล้ว +1

    Where do you buy spirit of salts?

  • @maddawglodbrock1380
    @maddawglodbrock1380 4 หลายเดือนก่อน +1

    It’s a common fault with these boilers its the 2 black rubber pipes that run up the side they corrode and the rubber falls off and blocks up the plate heat exchanger

    • @davelaye7003
      @davelaye7003 10 วันที่ผ่านมา

      terrible design, i would never install or advise to fit a Viessmann. as bad as Baxi

    • @maddawglodbrock1380
      @maddawglodbrock1380 10 วันที่ผ่านมา +1

      Worst thing was when you tried to claim on the warranty they would try blame it on old system pipe work saying it needed to be flushed I got wise to it when I’d installed a few new systems new everything and it would happen a few weeks later that’s why I never fit them any more especially when they don’t fix their faults and blame the installer that’s why I stick with Worcester most of the time there customer service is great and they fix there faults if one occurs

  • @richardpool481
    @richardpool481 6 หลายเดือนก่อน

    If you’re doing the shower hoaky coaky replace it don’t bodge it

  • @davebayliss3142
    @davebayliss3142 8 หลายเดือนก่อน

    Spirit of salts will rock the inside of that plate exchanger doesn’t matter how much water you flush through afterwards

  • @gabipaduraru2004
    @gabipaduraru2004 18 วันที่ผ่านมา

    After cleaning with HCl you must wash with a baking soda solution

  • @mehmetmetin8783
    @mehmetmetin8783 8 หลายเดือนก่อน

    👍🧿👏