BOILER KEEPS LOSING PRESSURE - WHY AND HOW TO FIX - Plumbing tips

แชร์
ฝัง
  • เผยแพร่เมื่อ 15 ม.ค. 2025

ความคิดเห็น • 921

  • @plumberparts
    @plumberparts  6 ปีที่แล้ว +27

    Please consider subscribing - Uploading still today!
    *Please Follow my Vlog, TimesWithJames* th-cam.com/users/timeswithjames
    *PLUMBERPARTS AMAZON TOOL SHOP* www.amazon.co.uk/shop/plumberparts

    • @user-ns7vj4tz5h
      @user-ns7vj4tz5h 6 ปีที่แล้ว

      My hot water pressure is very low. I have checked in all the taps and also the boiler pressure gauge pipe is not working. Normally it makes sound when i fill up the pressure but this time it's not making any sound so it means the water is not going into boiler. Please advice me. Thank you.

    • @tudormorgan3762
      @tudormorgan3762 4 ปีที่แล้ว

      P

    • @patrikgora4791
      @patrikgora4791 4 ปีที่แล้ว

      ++

    • @lemsdarkapprentice2535
      @lemsdarkapprentice2535 4 ปีที่แล้ว +1

      loads of thanks for this. my boiler keeps losing pressure. it's a new boiler, so i know it's not that. but my bathroom radiator valve (not a modern rtv, just a knob) leaks and goes cold after a time, even when heating is still on. might it be this causing the loss of pressure? and do you have any videos about how to change it to a new rtv? [el'sda2].

    • @IamSparticus2
      @IamSparticus2 3 ปีที่แล้ว +1

      @Maximus Hamza what are you saying, we should all hack your girlfriends account ?

  • @GIBLETTS
    @GIBLETTS 3 ปีที่แล้ว +45

    I am actually a plumber who is 63 , so our young friend is great for me to keep constantly updated ,, plus he is a really nice guy , thanks for sharing your knowledge , I can see you are going a long way ,,

  • @John-ob7dh
    @John-ob7dh 3 ปีที่แล้ว +11

    You can keep these new fangled boilers.ours was fitted in 67 .ideal stnd 40/ 60 boiler.floor standing.serviced every year. All its ever had fitted is one new gas valve ( 20 years ago ) i thermo couple ( 15 years ago ) and 1 new pump. Big detached house ,10 rads .even on coldest days we don't need heating on high.It never let's us down .As the last fitter said on its service .They don't make them like this anymore .I have all the spares ( only 3 spares) .gas valve ,thermo links ,thermostat assembly.no fancy electrics.No messing around adjusting pressure. Fingers crossed it will keep going as its only been here 54 years.lol

  • @sinbadcleo
    @sinbadcleo 5 ปีที่แล้ว +8

    Thanks for that clear explanation. I 'stumbled on' this vid not quite a week after I'd called out a tech-specialist plumber (Warranty Ts&Cs ) who found 'zackly what you described - a deflated pressure expansion 'balloon' and a gushing px. release valve hidden low down behind some spare bricks. Less than 5 minutes to diagnose, 20 minutes to service in and out..... and on his way. I really like it when a skilled pro works fast and right, like that.

  • @kelvinedwards5365
    @kelvinedwards5365 ปีที่แล้ว +1

    I have been a breakdown engineer for 40+ years and a friend has a flat in london and was being conned . instead of writing out all of the possible reasons for constantly topping up the system i pointed her to this video...very good... i might look at your other videos now...lol

  • @adamtannock
    @adamtannock 6 ปีที่แล้ว +37

    Another tip for combi boiler pressure drops. After trying all the above, if you’re still getting a drop you can fit 2 isolation valves under the boiler on the flow and return. Isolate this for 2 days and check pressure after. If it drops then it’s the boiler, if it holds and then drops after you open valves then it’s the pipe work.

    • @cglees
      @cglees 15 วันที่ผ่านมา

      That’s genius thank you!!!! 😊

  • @mr.dahliaking.202
    @mr.dahliaking.202 6 ปีที่แล้ว +1

    My neighbor recommended me for her friend, because she had a problem of her gas boiler mysteriously loosing pressure. On Sunday I will go there and check, maybe I will be able to fix it. Gosh, I haven't had many chances to work on heating systems, except in my own house, witch has become now sorta like my own learning grounds. Well, if there is a simple leak on system, or if there is simply bad vessel of Relief vale, I might as well get lucky. I'm learning everyday. I'm surprised that a middle aged woman is confident in 19 yo self thought plumber wannabe, in fixing her boiler. This video is going to be my guide. thanks a lot James.

  • @SkillBuilder
    @SkillBuilder 7 ปีที่แล้ว +181

    Why so many hates? A quarter of a million views means that a lot of plumbers have probably lost a lot of money, but the sad fact is that a lot of plumbers aren't great at fault finding. I have been out to jobs where they have had three or four plumbers in and none of them have noticed that the pump has been fitted the wrong way round or something equally simple.

    • @plumberparts
      @plumberparts  7 ปีที่แล้ว +25

      Yeah, I'm sure it's grumpy plumbers! Hey I'm a plumber so I know how grumpy we get!

    • @nukacola3795
      @nukacola3795 6 ปีที่แล้ว +10

      Plumbers didnt lose a penny from this as THEY CANT LOSE MONEY THAT WAS NEVER GOING TO THEM! see how money loss works now.

    • @pomzmetaldetecting1618
      @pomzmetaldetecting1618 6 ปีที่แล้ว +4

      A little knowledge can be dangerous, I could roll off 101 reasons why the general public should not follow out just some of the simple task in this video such as he recommends turning the pump speed down with no future content as what else could go wrong following that simple action like leading to the boiler overheating and in extreme cases split the heat exchanger, then your in a world of pain an see how you saved money by not calling a professional🙀

    • @williammcgrattan9583
      @williammcgrattan9583 6 ปีที่แล้ว

      Don't get myself? It's a helpful video

    • @SHANUSHAH
      @SHANUSHAH 5 ปีที่แล้ว +3

      @@plumberparts You mate are very Honest Plumber, good on you.

  • @swabs7004
    @swabs7004 8 ปีที่แล้ว +2

    I cannot understand why this video has so many dislikes, I have read numerous forum posts about pressure drops on boilers and none of them are as comprehensive as this video. This video fully explained to me the various reasons for pressure drop and the cut away expansion vessel was great. Loved the video . Thanks

    • @plumberparts
      @plumberparts  8 ปีที่แล้ว +2

      I honestly don't get it either. It's probably tossers! SUBSCRIBE! ➡️👉 th-cam.com/users/plumberparts 👈⬅️if you haven't already!

  • @Tonka-os9lt
    @Tonka-os9lt 3 ปีที่แล้ว +13

    Best video on boiler problems out there. Well done and thanks. You have helped me understand my problem comprehensively and it cost me nothing. Thanks again!

  • @jcrego
    @jcrego 4 ปีที่แล้ว +6

    I always find these videos extremely helpful. Was losing pressure, looked around and found o ring on magnetic filter was seeping. Opened filter cleaned it out (really horrible job) and replaced o ring with a new one. Pressure remains constant. Thank you very much!

  • @isaacsharp3886
    @isaacsharp3886 3 ปีที่แล้ว +4

    Currently working towards my nvq level 3 in plumbing and gas safe . Your videos help me a lot , thanks

  • @annewilliams7280
    @annewilliams7280 4 ปีที่แล้ว +2

    I have spent all day trying to fix this, online, phoning plumbers, getting baffled. I thought a picture of the valves might help, so spent more time online - then - I happened on this. IT IS BRILLIANT, a simple demo was all I needed. Thankyou ( one cold shower was quite enough)

  • @stardust5397
    @stardust5397 3 ปีที่แล้ว +6

    Explains it so clearly even I can understand it ! I had a new Combi installed 3 months ago & I’ve had to top it every couple of weeks - CH Engineer said it would settle - it hasn’t . Ive now good a good idea of what the problem is as overflow pipe outside is constantly dripping & so rather than feeling the Engineer is speaking to me in a foreign language I can have a more informed conversation with him - & that’s why the 3m dislikes as the old school cast iron boilers with a life span of 20 /30 years with occasional repairs have been replaced by boilers with umpteen plastic components, built in obsolescence & the creation of a whole new £££m industry to teach & test Heating Engineers who then go on to charge £££ to install , service & repair the dam things. They might be more efficient but I reckon these additional costs more than outweigh any savings on my gas bill

  • @ahmedthorlu-bangura2639
    @ahmedthorlu-bangura2639 2 ปีที่แล้ว

    Thanks

  • @garethsharp4039
    @garethsharp4039 4 ปีที่แล้ว +3

    Great video, thanks for posting. Used the bike pump trick to add a bit of air into the expansion vessel as it had been dropping pressure, and had gone through the other trouble shooting. Hopefully it'll get the boiler through the winter. It's on borrowed time to be fair, but not in a rush to replace it! Thanks again!

  • @stevenmcfarlane8831
    @stevenmcfarlane8831 3 ปีที่แล้ว +1

    Not a plumber just someone that has to frequently top up the filling loop. Two plumbers have attempted to fix / replace expansion vessel. Thank you for your thorough explanation.

  • @ColinWatters
    @ColinWatters 3 ปีที่แล้ว +10

    Once a Pressure Relief Valve has been forced open (perhaps by a faulty expansion vessel) they frequently start leaking or opening at a lower pressure. So if you have a faulty expansion vessel that causes the PRV to open consider replacing the PRV at the same time. Not always necessary but they aren't very expensive and might save you another drive to the plumbers merchant.

  • @m.f.b7144
    @m.f.b7144 3 ปีที่แล้ว +1

    Thank you for a thorough explanation. I’m having a pressure loss on my boiler and keep topping up twice a day so I can get hot water and heating. I had about 3 plumbers from BGas, I’m insured with them, coming over to my house and none of them did a thorough check. The first one, balanced the radiators and left. Water pressure still low, next engineer came over looked at the water pressure gauge and left (I had just refilled it). Third one recharged the expansion vessel and said boiler needs to be taken down to repair completely. At this point, after 5 weeks of engineers missing appointments and other engineers hardly looking at the boiler itself, the problem hasn’t been solved. I have taken notes from this video and next time I shall prompt the engineers to check on these points you mentioned before they leave an unsolved job. Thank you!

    • @lindaj5492
      @lindaj5492 3 ปีที่แล้ว +1

      I’m covered with same company: had three visits on consecutive days trying to fix pressure drop. On last visit, engineer was about to order new expansion vessel but found water stain on ceiling in a walk-in cupboard where there was no radiator. He’d already checked visible pipes & rads for leaks; glad he had a hunch to open that door! Stayed on another two hours to replace failed plastic T-joint, despite being soaked from the puddle above ceiling.

    • @RD-ox3ce
      @RD-ox3ce 3 ปีที่แล้ว +4

      Don’t let those BG cowboys near your system.
      Most are 6 week wonders and don’t have a clue

  • @fardellp
    @fardellp 6 ปีที่แล้ว +9

    Nice presentation and good advice. Worth pointing out though that the expansion vessel air pressure (1 to 1.2 Bar) is normally quoted for COLD condition. It shouldn't be pumped up and the pressure measured when the water is hot.

    • @dhiruparmar8908
      @dhiruparmar8908 3 ปีที่แล้ว

      Hi
      My boiler pressure is just above bar 1 in the mornings and when boiler is on it goes up to just under bar 2 range.
      Could you please advice is this normal.
      Thank you.

  • @petersabatino3136
    @petersabatino3136 7 ปีที่แล้ว +1

    Good man I'm a heating engineer of 30 years and you are a pleasure to listen too.

    • @tinamendonca7241
      @tinamendonca7241 3 ปีที่แล้ว

      Do you live near the Middlesex area?

  • @williambarr4822
    @williambarr4822 5 ปีที่แล้ว +117

    When Bradley Cooper’s brother fixes your boiler

  • @Goodchappy
    @Goodchappy 6 ปีที่แล้ว +2

    Excellent video. Videos like this educate people so that when they get a tradesman in they are more clued up and far less likely to get told a load of rubbish.

  • @ErikP95
    @ErikP95 7 ปีที่แล้ว +4

    Thanks man, very helpful and informative! Found a small leakage in my bathroom radiator..

  • @derrickmartin4894
    @derrickmartin4894 3 ปีที่แล้ว

    Brilliant ,as a heating engineer i did not learn any thing from this video
    , but most of the plumbers I know would,

  • @fardellp
    @fardellp 6 ปีที่แล้ว +4

    Another point - the PRV can develope a leaking seat, as it is contact with acidic/particle/general muck from the primary boiler water. This can be especially prevalent where the PRV has actuated due to over-pressure. When the pressure has reduced and the valve closes again, bits of grit are left on the valve seat which can fail to seal properly leading to a permanent dribble.

  • @herrklamm1454
    @herrklamm1454 2 ปีที่แล้ว

    Happiest plumber I’ve ever seen.

  • @linlegerton3482
    @linlegerton3482 5 ปีที่แล้ว +20

    Thank you this was so helpful, living on my own after 23 years of marriage, starting to get the hang of things 😄

    • @linlegerton3482
      @linlegerton3482 5 ปีที่แล้ว

      👍👍👍👍👍

    • @johnvonhorn2942
      @johnvonhorn2942 5 ปีที่แล้ว +5

      Ask Plumberparts to pop round and give you a good servicing causing his pressure release valve to explode. That would get ten million views and you'd both walk away as millionaires.

    • @bonkeydollocks1879
      @bonkeydollocks1879 5 ปีที่แล้ว

      I will pop round lin and fix it no probs

    • @JJ-bv7fc
      @JJ-bv7fc 4 ปีที่แล้ว

      @@johnvonhorn2942 loooool

  • @freespirit6209
    @freespirit6209 4 ปีที่แล้ว +1

    Brilliant. This will enable me to speak to my plumber much more intelligently! Thanks!

  • @meridpeace
    @meridpeace 8 ปีที่แล้ว +3

    Unlike your other excellent videos, this lecture seems to aim the already experts. This is a very fast lecture that flies over the head of 90% of the people who come to find a step-by-step procedures of fixing things in a very clear and brief presentation. Choose one or two kinds of popular boilers and show us doing it. People come to youtube to "see" not to hear. Otherwise, you are very knowledgeable and helpful. Please keep on helping.

    • @plumberparts
      @plumberparts  8 ปีที่แล้ว +16

      Hi Merid. Thanks for your comments and I hope you continue to keep watching! I would like to draw your attention to the pause button! All the best PP!

  • @AbdulJabbar-eh5ve
    @AbdulJabbar-eh5ve 3 ปีที่แล้ว

    You are a brilliant person, very nice any person with little experience of plumbing will love you mate have a nice day.

  • @corinthh11
    @corinthh11 3 ปีที่แล้ว +4

    We moved in to a brand new built house and for 16 years we had pressure drops in the heating .we had all the floors lifted multiple times looking for a leak but not could be found .the pressure drops always seemed random more in the winter and less in the summer ,in the end we just kept topping it up with the housing association permission about once or twice a month. At the beginning of Dec 2021 the pressure started dropping twice or more a day.however this time i could see and hear something not right in the kitchen steam was coming out from just under the boiler
    where the pipes where .on investigation i found a leak where the condensation pipe was touching the heating return pipe the acidity in the water had caused a small leak and water was squirting out it was very hard to see at first as the condensation pipe was covering the leak and was dripping from the pipe lower down .when i moved the condensation pipe the leak was obvious and the pipe had corroded to the point a pin hole leak could be seen this was obviously a job for the plumper who would not be able to get out this the morning .it was very cold and we needed the heating on over night and being a ex Rn marine engineer i decided to put a patch on it with some rubber and a pair of hose clips. this in when i noticed that as i manoeuvred the rubber and hose clamps and the pipe moved water would also squirt out of the elbow joint connected to the pipe, if i stopped putting a slight strain on the pipe the squirt stopped even though the system was pressurised .in the morning the plumber came out and spent most of the morning replacing the pipe that had corroded and i had mentioned to him about the elbow joint and that i though this was the cause of the pressure leaks we had lived with so long .after he had removed the pipes and fitted the new ones i noticed on inspection of the joint that they was NO solder around the back side of the pipe and they was a clear gap between the two components/joint and looked like it had been soldered by a monkey. they had been no evidence of a leak at this joint before hand and i suspect the very very small leak and the water that had come out had evaporated on the hot pipe condensed on the condensation pipe the before causing any noticeable damage and eventually rotted the return pipe e you would expect from a leak,coupled with the fact the very small place the pipes where located where under the kitchen units and where the pipes came from under the floor part of the floor was missing to allow the pipes to come up so any water damage was beneath where you could see without removing the units and floor.since the repair our pressure has not dropped once.bad plumbing is a nightmare to figure out especially when the joints are hard to see one tip i could give is wrap newspaper round any joint you suspect as when it gets wet it is easy to see the effect on the newspaper (trick i learned from my dad)

  • @metube9541
    @metube9541 3 ปีที่แล้ว +2

    Great video, never thought about the pump being set too fast but that makes sense. Thanks.

  • @radukapu
    @radukapu 6 ปีที่แล้ว +16

    You are amazing! Wish there were more professionals like you in the business! Thank you for sharing your knowledge!

  • @jimgrimes818
    @jimgrimes818 9 ปีที่แล้ว

    Good video, i'm sure many people have problems with pressure drop and this video will be of great help, however they should have their heating system checked before winter starts. Well worth it.

    • @plumberparts
      @plumberparts  9 ปีที่แล้ว

      Hasn't stopped there being 80odd dislikes!!! 😜

  • @DeborahWalkerXOXO
    @DeborahWalkerXOXO 5 ปีที่แล้ว +6

    "Stumbled across" this video! One minute and some change in and I am wondering if I will finish it... very engaging host but at this point I'm questioning my entire life!

    • @MrDaiseymay
      @MrDaiseymay 4 ปีที่แล้ว +2

      play the vid at 75% speed---much more absorbable.

  • @robertbridges5328
    @robertbridges5328 3 ปีที่แล้ว +1

    Thanks, I was always told by the plumbers who came out to us that we had a water leak in the pipes in the ground, after this video I can see it the Pressure relief valve as from day one we have had water running out the back of the boiler. Will look at tank also thanks.

  • @CoolMusicToMyEars
    @CoolMusicToMyEars 5 ปีที่แล้ว +7

    Dont forget also tighten up the heat exchanger to it's back plate & rubber washers, this happens on a Viessmann 200W boiler

  • @ade7163
    @ade7163 2 หลายเดือนก่อน

    Cheers mate, best plumbing videos on YT! Common sense advice along with your sense of humour! 😁 Now off to investigate that pressure loss after fitting magnetic filter yesterday! 😅

  • @johnkerr8019
    @johnkerr8019 5 ปีที่แล้ว +6

    Good one "Hose Mourinho".
    I have completed a check of all my radiators, no sign of leakage and removed cover on the boiler, no apparent leaks and looking very dry. The pressure is dropping and radiators appear to be outputing more heat than is indicated on the digital reading on the boiler. Do you think it could be PRV or is something else going on.
    Thanks for posting this excellent and say hello to "Mr.G"
    Greetings from Glasgow

  • @pkf4124
    @pkf4124 4 ปีที่แล้ว +1

    My friend is a heating engineer and we have this issue so its nice to know the basic checks so I can let him know, before he comes round. Thanks for your advise.

  • @fieldsofomagh
    @fieldsofomagh 9 ปีที่แล้ว +34

    Great info on the central heating system.The plumber finished with his girlfriend this weekend, he said; "it's over Flo"

    • @geoffcollins2094
      @geoffcollins2094 6 ปีที่แล้ว +1

      Awesome

    • @gdfggggg
      @gdfggggg 6 ปีที่แล้ว +1

      Only 9/10 as it needed to be a bit shitter

  • @johnfoster5427
    @johnfoster5427 4 ปีที่แล้ว

    Good to find somebody who sticks to the point and not waffling on about nothing, well done, good vidio

  • @christracey2837
    @christracey2837 6 ปีที่แล้ว +9

    Yes I stumbled across this. Excellent Vid Thank you

    • @plumberparts
      @plumberparts  6 ปีที่แล้ว +1

      No worries! Still making videos today, plus you can follow me on Instagram here: www.plumberparts.co.uk/social.php?social=Instagram FANKS!

  • @normanmcintosh4241
    @normanmcintosh4241 5 ปีที่แล้ว +1

    Excellent explanation and I think you have give me the answer I required. New pressure vessel required. Thank you sir

  • @esjay8066
    @esjay8066 8 ปีที่แล้ว +6

    Hi there been watching a few of your video's, wondering if you could guide me in the right direction? my boiler cut out due to the pressure dropping over a leaking radiator and we have had the heating on, the problem is.....I can't get water back into the system, turn on the filling and nothing is happening, no flow of water for some reason, I've bled the radiators, any help would be appreciated Thanks.

  • @danielpeters6129
    @danielpeters6129 2 ปีที่แล้ว

    Very good useful video. Explains clearly exactly what to check and how. Will certainly try this and see if I can find the problem.

  • @nakedtraitor1802
    @nakedtraitor1802 7 ปีที่แล้ว +3

    Excellent video. Thank you so much. My boiler keeps losing pressure and I'm having to top up everyday. Any idea what could be wrong?

    • @bonkeydollocks1879
      @bonkeydollocks1879 5 ปีที่แล้ว +2

      Err the answer is in the video you just watched..

  • @Hogman666
    @Hogman666 2 ปีที่แล้ว

    Great stuff we have a problem and it's looking like an expansion vessel and or pressure relief valve.
    Definitely feel more comfortable and confident on looking for quotes.

  • @modclan
    @modclan 6 ปีที่แล้ว +4

    Great Channel. I always come here for good honest advice. well done mate. keep the good work up.

  • @ofeliawotsits6080
    @ofeliawotsits6080 21 วันที่ผ่านมา

    The two scenarios I’ve had were a rust spot on a radiator that very slowly weeped water and the system lost pressure, and the other was the air bladder that keeps the pressure constant. Its diaphragm broke down and was a straightforward replacement on our Vaillant combi. Only other problem was the main circuit board went bad! A bit weird, but getting the right part number was slightly tricky however with the right part it was a doddle to replace and no trouble since.

  • @thermion7869
    @thermion7869 4 ปีที่แล้ว +10

    The main reason for removing the filling loop, is to prevent the contaminated water in the system getting back into the cold water mains supply.

    • @danlux4954
      @danlux4954 3 ปีที่แล้ว

      In Canada there’s a backflow prevention device on the fill.

    • @Finglesham
      @Finglesham 3 ปีที่แล้ว +1

      @@danlux4954 and in the UK

  • @rojhasan548
    @rojhasan548 ปีที่แล้ว

    Thanks, very insightful video.
    One comment though, pump cavitation occurs in the low pressure (usually vacuum) region at the eye of the impeller when the pump inlet pressure is too low. Due to the low pressure environment, the water's boiling temperature is much lower and what happens is that water changes phase into vapour, rather than the impeller splitting the water and air molecules.
    So instead.of water boiling at 100degC ( at sea level pressure) at the eye of the impeller it could be boiling at 40degC or even 25degC.
    Anyway once this cavitating flow enters the exit of the impeller its is represurised to due gaining the spinning work from the impeller and you will hear the vapour bubbles pop and burst letting out tiny acoustic waves that start to damage and grind away the impeller blades.
    One result.of cavitating flow, is the loss of pump exit pressure, it can be identified as NPSH3%.

  • @nickbrown3300
    @nickbrown3300 8 ปีที่แล้ว +5

    Looking forward to testing the Expansion vessel and PRV tonight! Great video, love the way you explain the system, makes it so clear.
    Cheers

    • @plumberparts
      @plumberparts  8 ปีที่แล้ว +1

      No worries, thanks Nick!

  • @daveshirley
    @daveshirley 3 ปีที่แล้ว +1

    Thank you soooo much! Thats saved us a bob or two! We had a filter installed as recommended but the guy hadn't tightened up one of the nuts quite enough and was trickling water out!! Tightened it up and Bob's yer uncle! Sorted!!

  • @amirhussain1449
    @amirhussain1449 9 ปีที่แล้ว +10

    lovely one pp,you've got good infomat've video's that's why you're getting the jealous plumbers disliking the vids

    • @plumberparts
      @plumberparts  9 ปีที่แล้ว

      +amir hussain Yeah, cheers Amir!

  • @mikeflynn4373
    @mikeflynn4373 3 ปีที่แล้ว

    Excellent as usual for Plumberparts.

  • @plumberparts
    @plumberparts  9 ปีที่แล้ว +29

    Why has this got so many dislikes?! :)

    • @thegrandmuftiofwakanda
      @thegrandmuftiofwakanda 9 ปีที่แล้ว +8

      +plumberparts Not sure. This is good quality stuff.

    • @plumberparts
      @plumberparts  9 ปีที่แล้ว +10

      +billiepipersteeth Weird isn't it? I think most people just want to solve the symptom, rather than just dealing with the actual cause!

    • @dieselbiggins
      @dieselbiggins 9 ปีที่แล้ว +23

      +plumberparts it must be professional plumbers building a resentments against you for giving away trade secrets. 😉 I on the other hand salute you sir!

    • @plumberparts
      @plumberparts  9 ปีที่แล้ว +5

      +dieselbiggins Ha! thanks dude!

    • @plumberparts
      @plumberparts  9 ปีที่แล้ว

      +Robert Granger Cheers Robert!

  • @johnkeys368
    @johnkeys368 ปีที่แล้ว

    Excellent video ,thank you James.

  • @denismoloney27
    @denismoloney27 9 ปีที่แล้ว +3

    Isn't the braided hose is removed to prevent mains water contamination.

    • @plumberparts
      @plumberparts  9 ปีที่แล้ว

      +denis moloney Well kinda. Mains water can't 'contaminate' as such, but it can over-pressurise the boiler water if the mains valves start to let by. PP!

    • @markrainford1219
      @markrainford1219 9 ปีที่แล้ว +3

      +plumberparts No, but the heating system water can contaminate the mains water if the check valve is faulty, that's why the bye laws say you have to remove the loop. I'm a plumber and Ithought this vid was pretty good, don't understand the dislikes either.

    • @jaxmar88
      @jaxmar88 8 ปีที่แล้ว

      Yes, it is a water bylaw but ignored by many forign boiler manufacturers, Worcester Bosch mostly use a removable key (bridge) to comply with the regulations.

    • @robertgreenaway5166
      @robertgreenaway5166 7 ปีที่แล้ว

      It creates an “air gap”. So that if the check valve fails then heating water can’t contaminate the mains if there were to be any loss in pressure to the mains... doesn’t happen often but it does happen. If a water main was to burst for an example there would be a sudden loss of pressure on the incoming main.

  • @lindaj5492
    @lindaj5492 3 ปีที่แล้ว +2

    3:25 Yep, finding a brown patch on a ceiling, or water dripping from a wall switch is BAD! Turned out to be a failed T-joint. Heating engineer who found eventually source of repeated pressure drops - on third visit - told me that the plastic “push-click” joints used with plastic central heating pipes “just do that” 😳 He had to go in through ceiling and replaced it with a brass one (‘luckily’ the smallish ceiling hole is in a walk-in cupboard, so not in my face whilst I wait for plasterer; insurance excess too high to cover cost).

  • @inkwhir
    @inkwhir 7 ปีที่แล้ว +11

    The cavitation does not produce hydrogen, but just steam. During cavitation the water is simply boiling at room temperature because of the low pressure.

    • @TW-mp8zx
      @TW-mp8zx 4 ปีที่แล้ว

      inkwhir correct and depending on the rate of cavitation it might sound like your heating system is circulating tiny marbles...

  • @train4905
    @train4905 2 ปีที่แล้ว

    An absoluteluy brilliant video sir.

  • @djfriskyd1857
    @djfriskyd1857 6 ปีที่แล้ว +5

    Plumbers and Gas Engineers are two different areas of work

  • @AbbasKhan-ud6mr
    @AbbasKhan-ud6mr 2 ปีที่แล้ว

    Thank you for your videos, you've helped me so much over the years and saved me a lot of dough.

  • @BrummieGuy
    @BrummieGuy 8 ปีที่แล้ว +3

    I've searched Google for hours and can't find an answer, my boiler loses pressure over a couple of weeks, but ONLY when the heating is on.
    If the heating is turned off, the presuure doesn't drop. I presume this rules out the PRV and expansion vessel?
    TIA

    • @markrainford1219
      @markrainford1219 8 ปีที่แล้ว

      It is almost certainly your boiler PRV or expansion vessel then.

    • @BrummieGuy
      @BrummieGuy 8 ปีที่แล้ว

      It's a Logic+ 30, it's now happening a couple of times a day. Isn't there a known fault with the logics and the error "Low flow lockout". All of the thermistors have been changed.

    • @markrainford1219
      @markrainford1219 8 ปีที่แล้ว +1

      Cleethorpes Kid
      You really need to get it sorted sooner rather than later. Every time you top it up , you introduce fresh oxygen into the system and you will rot out your rads prematurely.

    • @BrummieGuy
      @BrummieGuy 8 ปีที่แล้ว +1

      Sorry, I misread the error message when I originally posted 3 weeks ago, It's not losing pressure therefore I'm not topping it up. It keeps switching off with the error message "Low water flow lockout". If I reset the boiler it starts working again.

    • @Obsidianiron
      @Obsidianiron 8 ปีที่แล้ว

      That sounds like a blockage, some boilers will have a software lockout if there is an excessive temperature rise across the heat exchanger, this is due to poor water flow rate. The software is trying to protect the heat exchanger and let you know you have a problem before you lose the heat exchanger all together, then it gets expensive. If you are not loosing water you might have to chemically clean the water side of the heat exchanger, but that's not really a DIY job, you need to know what you are doing.

  • @michaellavery4899
    @michaellavery4899 9 หลายเดือนก่อน

    I like your video. It is the most comprehensive video regarding this problem I have seen. The only problem is you cover many topics whilst speaking really quickly, not giving the viewer time to comprehend the issues
    For example, you show the rusty nails and talk about hydrogen in the system. I don't think many viewers would have a good understanding of chemistry to understand that corrosion is the source of the hydrogen gas.
    I know viewers are put off by long videos, but they are also put off when they are overloaded with information they don't have time to understand.
    I know they can pause the videos but in reality they don't.

  • @dwarfsbaneironfist2527
    @dwarfsbaneironfist2527 6 ปีที่แล้ว +4

    Interesting, the gas fitter who services my boiler told me to leave the filling loop connected, previously I was removing it.

    • @plumberparts
      @plumberparts  6 ปีที่แล้ว

      Well most say don't just in case the fill valves start to let by.

    • @tectorama
      @tectorama 6 ปีที่แล้ว +1

      If you have a flexible loop, it's best to leave it disconnected, but a lot of boilers nowadays, don't have a flexible loop. They have a permanent connection, where you have to open two valves to let the water in.

    • @dwarfsbaneironfist2527
      @dwarfsbaneironfist2527 6 ปีที่แล้ว

      Thx, I have a flexible loop, next time I pressure it I ill remove it.

    • @daviddoyle2085
      @daviddoyle2085 6 ปีที่แล้ว +1

      During my courses there were a few reasons why you have to disconnect one is you could potentially contaminate mains water supply and the other was as mentioned if the valves let by and over pressurised the system. I've been on a visit where this has happens and it cracked the heat exchanger. Not cheap to replace.

    • @daviddoyle2085
      @daviddoyle2085 6 ปีที่แล้ว

      plumberparts Quick question could you get an airlock in an unvented system the same way a gravity system gets theirs? We have an issue on one of my site where we have checked absolutely everything and even added another expansion vessel on the system and changed the AAV but the systems still losing pressure.

  • @mozaman9005
    @mozaman9005 3 ปีที่แล้ว +2

    Hi I know this is quite old now, but if you happen to have drop in pressure which happens maybe over a month or so, with possible small leak, would you recommend the use of those leak sealer fluids?
    Can't seem to find the leak as described but havnt taken any floors up either on the ground floor, tiled and hardwood unfortunately!!

  • @matthewlowy3039
    @matthewlowy3039 7 ปีที่แล้ว +8

    Sorry, there's no way cavitation makes hydrogen and oxygen... cavitation is making little bubbles of (just about) vacuum with a little bit of water vapour in that collapse almost immediately and can damage the impeller in the pump.

    • @plumberparts
      @plumberparts  7 ปีที่แล้ว

      Can you read what you post before you post it! I don't understand the sentence...

    • @Biggles2498
      @Biggles2498 7 ปีที่แล้ว

      Matthew Lowy well done ! Cavitation also applies to Ship's Propellors (includes small boats) and causes damage to propellors under water ! I am an ex Ship's Officer.

    • @plumberparts
      @plumberparts  7 ปีที่แล้ว

      Good on you dear boy! My bro's in the RAF.

    • @mrbachittarsingh9243
      @mrbachittarsingh9243 7 ปีที่แล้ว

      It also affects the pcb

    • @tauttechminusmanagedmusic3778
      @tauttechminusmanagedmusic3778 6 ปีที่แล้ว +1

      Actually, it does. The cavitation is not just boiling of the water to create pockets of "air" (It's a combination of water vapour and dissolved air) - the bubbles are low pressure but they are most certainly NOT a vacuum. The physics of the situation dictates the water can break down into hydrogen and oxygen because in addition to the mechanical motion and heating there is also an electrical flow in progress. The multiple types of metal in the system ensure an electron flow. So yes, the pump is one of the places where water is split into hydrogen and oxygen. The popping you may hear in radiator is sometimes the two gasses recombining into water, but the amount of free oxygen is often less than the hydrogen because the oxygen binds to the corrosion inhibitors in the system or sometimes the chlorine in the water (molecular compound, not ionic). This leaves more free hydrogen to vent. Most of the gas coming out of the system when bleeding is just normal "air" that was dissolved in the water, but it has a higher concentration of hydrogen than the atmosphere. Cavitation damage to props and impellers is largely shock damage when the bubbles collapse. There are several videos on YT which explain how the bubbles are created using cavitation by snapping shrimp. Have you listened the din on hydrophones? - those shrimp a really loud!
      I'm no ship's officer (catering?), but I do my own plumbing, electrical work, electronics repair, and systems design for reactive systems such as fuel flow in aircraft engines . I also have degrees in Computational Engineering and Physics (lots of free time after breaking my back at the age of 24, many moons ago.) Plumbers get annoyed that I do all my own work, but I do respect their advice when I ask them to come and check my work; something I always do after finishing.

  • @Simpilotrichy
    @Simpilotrichy 3 ปีที่แล้ว

    Just stumbled upon your channel in my quest to become a modern DIY husband (exacerbated by the impossibility of finding a tradesman these days) Fabulous information! Your the new Roger Bisby :) Best regards and keep up the great work!

  • @b1h2u3p4
    @b1h2u3p4 7 ปีที่แล้ว +12

    Too much detail for head to take in.

    • @highdownmartin
      @highdownmartin 7 ปีที่แล้ว +1

      b1h2u3p4 then you'll always need a plumber until you understand. I thought it was great and very understandable

  • @garry843
    @garry843 11 หลายเดือนก่อน

    Thankyou for the video. I think you have jogged my memory, not having had to touch a boiler for years. The relief valve is dumping water at well below working pressure. I just moved into this property and the boiler although working extremely well has been tanding for over two years. Too much work at the moment, rather the leak than the cold at the moment. I'll order up a new dump valve ready for the moment. Have they done away with the filling key in the cover as i have a single ball valve in the line which in my experience is not the best idea.Thanks again.

  • @ahsanafzal48
    @ahsanafzal48 6 ปีที่แล้ว +4

    My head expansion is about to happen 😨

  • @jamesallen6007
    @jamesallen6007 3 ปีที่แล้ว

    Many thanks. I have learnt loads. Thanks again.

  • @m.v.k4681
    @m.v.k4681 7 ปีที่แล้ว +7

    Please talk a lot more SLOWLY so we can keep up and understand. Thank you. I have had to watch this about five times to be able to understand at this speed.

    • @wardogass6101
      @wardogass6101 6 ปีที่แล้ว +2

      Think quicker. It was fine, in fact excellent , a welcome no nonsense delivery. The worse videos are where where you have to constantly keep fast forwarding because they are so slow at getting to the point. Like I said, think quicker :)

    • @philipoxborough6110
      @philipoxborough6110 6 ปีที่แล้ว +1

      You can turn down the speed of the video in the settings at the bottom.

  • @gixxerthouk4
    @gixxerthouk4 4 ปีที่แล้ว

    very well explained heating video

  • @larrycurrier290
    @larrycurrier290 6 ปีที่แล้ว +3

    it's very difficult to compress water. no it's f****** impossible

    • @plumberparts
      @plumberparts  6 ปีที่แล้ว

      HAHA! you ain't wrong bro! Please consider subscribing - Uploading still today!
      *Please Follow my Vlog, TimesWithJames* th-cam.com/users/timeswithjames
      *PLUMBERPARTS AMAZON TOOL SHOP* www.amazon.co.uk/shop/plumberparts

  • @colinmiles1052
    @colinmiles1052 3 ปีที่แล้ว

    Very clear and comprehensive. Thank you.

  • @ayoolawore4566
    @ayoolawore4566 4 ปีที่แล้ว

    Thank you sooooo much. My heating is now working. I didn’t realise one of my radiator was leaking after trying to bleed it yesterday.

  • @jakecarson4587
    @jakecarson4587 4 ปีที่แล้ว

    Very interesting video my uncle has lived in his property for 65 years the radiators are pre 1980s 1 Plummer said he needs a new combi boiler and new radiators the next Plummer said he can save money by fitting a new combi boiler and fit it to the old radiators now every day when switched of the pressure drops then needs topping up starts flashing low pressure but when it’s on its stable no problems now I am thinking should of got new radiators to

  • @MOB30A
    @MOB30A 4 ปีที่แล้ว

    Absolutely fantastic and excellent video very valuable information. Thanks for uploading this video.

  • @jcmckean
    @jcmckean 8 ปีที่แล้ว +2

    Extremely helpful video, thank you. Very clear and unambiguous as usual. Thank you

  • @valhollylee8422
    @valhollylee8422 3 ปีที่แล้ว

    Blimey! Bradley Walsh is a heating engineer now as well! 😉😁

  • @jid48
    @jid48 2 ปีที่แล้ว +1

    thanks for this first class

  • @LabRat6619
    @LabRat6619 3 ปีที่แล้ว +2

    The expansion vessel in the combi is usually way too small for the system!
    Secondly you can get a pressure breed across the flat plate heat exchanger on a combi.
    So many problems I'm always busy fixing lol.

  • @Yoursisgreener
    @Yoursisgreener 2 ปีที่แล้ว

    Thanks mate good job 👍

  • @chrisseeker1
    @chrisseeker1 8 ปีที่แล้ว

    A very clear and helpful video that helped me. I don't mind, but some people might find the delivery too fast - you are allowed to breathe. Other than that I do not know why you got dislikes. I thought it was well structured and explained.

    • @plumberparts
      @plumberparts  8 ปีที่แล้ว

      +chris vanderweele Hi mate, thanks for your comment, will consider it for forthcoming videos! PP!

  • @lainaanial
    @lainaanial ปีที่แล้ว

    Thanks for that.

  • @theoyanto
    @theoyanto 2 ปีที่แล้ว +1

    Very informative and straight to the point 👍🏻

  • @ellabbs
    @ellabbs 7 ปีที่แล้ว

    awesome video mate, and well delivered, quite often i get to a boiler which needs repressurizing and they have no link pipe, how do you repressurize those types of boilers, a short vid would be great.

    • @plumberparts
      @plumberparts  7 ปีที่แล้ว

      Hmm, you'd have to use a hose pipe with valve at the boiler end and a mains tap at the other. Like old schoool back filling when you've got an airlock!

  • @christianbrendorfer6908
    @christianbrendorfer6908 3 ปีที่แล้ว +1

    Hello
    What about the Tec7 plumb?

  • @wildbirds1391
    @wildbirds1391 2 ปีที่แล้ว

    nice one m8, i listened to what you said it looks like its the pressure release valve, top man thank you great vid my friend :) 👍

  • @jarekpytel
    @jarekpytel 2 ปีที่แล้ว

    Absolutely great video.! Thanks

  • @bill1047
    @bill1047 3 ปีที่แล้ว

    This is excellent. Thank you.

  • @ddstephanie9432
    @ddstephanie9432 4 ปีที่แล้ว

    Very useful information,thanks for sharing your knowledge much appreciated

  • @imranfiaz6816
    @imranfiaz6816 6 ปีที่แล้ว

    Very useful thanks I fixed my own boiler with that video. I have a much better understanding of my boiler

  • @alfienme
    @alfienme 3 ปีที่แล้ว

    Thank you very much 👍

  • @johnkerr8019
    @johnkerr8019 10 หลายเดือนก่อน

    Rock on, my man, great video.

  • @sergd7885
    @sergd7885 3 ปีที่แล้ว +1

    I have baxi solo 2 pf the overheat lamp lights up and he does not want to turn on thanks for any help, pump ok work.