Line Construction Through Town

แชร์
ฝัง
  • เผยแพร่เมื่อ 1 พ.ย. 2024

ความคิดเห็น • 49

  • @markleon7127
    @markleon7127 2 ปีที่แล้ว +3

    We always place loose in the clamps with a soft sag then go back and tension and tighten clamps. A little safer that way I believe. I will say I miss our t-40 line truck they make jobs like this so much easier. Nice vid man

  • @CreepingDe4th81
    @CreepingDe4th81 2 ปีที่แล้ว +3

    Awesome vid man. It's like watching my life lol

  • @Coughline5
    @Coughline5 3 ปีที่แล้ว +4

    Sweetest preform throw ever witnessed

  • @dkirkham5944
    @dkirkham5944 2 ปีที่แล้ว +1

    Hey in your new run video it looks like you also caught your hand in the lasher haha. Cool vid

  • @Up2_nogood
    @Up2_nogood 2 ปีที่แล้ว +2

    Any updates man? How's the last year been for ya.

  • @ElectroTree01
    @ElectroTree01 ปีที่แล้ว +2

    Interesting!

  • @dannyhernandez5959
    @dannyhernandez5959 3 ปีที่แล้ว +6

    I start my first day as an apprentice lineman telecom in a week, I was wondering what are some basic tools I should have my first day bud ?

    • @bboygio393
      @bboygio393 3 ปีที่แล้ว +1

      With the union?

    • @mattygates1
      @mattygates1 3 ปีที่แล้ว +3

      They should supply them. Safety equipment and otherwise.

    • @kctyphoon
      @kctyphoon 3 ปีที่แล้ว +1

      Knipex. NWS, or Klein - if youre buying your own tools.

    • @culbyj3665
      @culbyj3665 3 ปีที่แล้ว

      Did you start with a Big telecom ISP or not not? hows it going, They usually provide.. how ya making out?

    • @Popesontour
      @Popesontour 3 ปีที่แล้ว +3

      QUIT NOW OR YOUR SCREWED!

  • @RC-Heli835
    @RC-Heli835 หลายเดือนก่อน

    Are you still a lineman? I noticed you haven't done a video in a while.

  • @duncansmith5102
    @duncansmith5102 2 ปีที่แล้ว +2

    Big up E.C.E cable hail up the line man them u dun no seh a culie mickey from Jamaica

  • @talmadge1171
    @talmadge1171 3 ปีที่แล้ว +4

    Waiting for some new uploade

  • @Selurit
    @Selurit 4 ปีที่แล้ว +2

    i've seen ppl with that work truck before but there logo was comcast or comed and they were both doing the same stuff but idk if there's different roles other companies do. can you give me some insight of what they do if not then that's okay. i'm just looking for a career change and just want to go for the right one.

    • @Mediocre1987
      @Mediocre1987 4 ปีที่แล้ว +1

      Meleeing typically you’ll have “in house” employees and then you’ll have contractors/sub contractors. They all do the same work just depends who signs your pay check.

    • @mikel9567
      @mikel9567 3 ปีที่แล้ว +2

      They pretty much do the same work, but in-house typically will pay more. Usually the contractors will do the line building or plant extensions and the in-house crews will do the technical work and actual installs. I worked for a company that was a contractor to Comcast. We did everything from plant extension / upgrade work (what you see in this video) to actual installs. Comcast in-house crews also did installs and they did repair work. The simple truth is there is more work than the in-house crews can handle which is why they contract out. A smaller company probably won't contract out their installs, but will contract out their plant construction work. Whatever you do, stay away from installs. Installs are usually paid "piece-meal" where as the construction side is paid hourly. Stick with construction if you want to do telco work.

  • @DodgeCharger-d8z
    @DodgeCharger-d8z 9 หลายเดือนก่อน +2

    Nuts are on backwards chooch …flat to flat

  • @tommycraddock7065
    @tommycraddock7065 3 ปีที่แล้ว +3

    No harness?

  • @jotamendonca8614
    @jotamendonca8614 10 หลายเดือนก่อน +1

    Aqui no Brasil é muito diferente, os postes são de concreto, só usamos cinta bap. O vídeo está excelente.

  • @shaunferdinand7960
    @shaunferdinand7960 3 ปีที่แล้ว +2

    We do the exact same job here in Trinidad

    • @prackash0359
      @prackash0359 ปีที่แล้ว +1

      How much do yall get paid in Trinidaf?

    • @shaunferdinand7960
      @shaunferdinand7960 ปีที่แล้ว +1

      We could survive let's put it like that.😊

  • @woodhook
    @woodhook 2 ปีที่แล้ว +2

    don't listen to the BS,nice job.

  • @deepspacecow2644
    @deepspacecow2644 11 หลายเดือนก่อน +1

    Is this FTTH or the usual long haul telecom stuff?

  • @erickmorrow7815
    @erickmorrow7815 ปีที่แล้ว +1

    In search of a experienced cable lasher lineman to run a small crew in Wisconsin as a permanent job

    • @Goo4Yakno
      @Goo4Yakno 2 หลายเดือนก่อน

      Did you ever get this position filled!? Or are you still needing work? It’s 2 of us willing to travel anywhere

  • @deeloks6914
    @deeloks6914 11 หลายเดือนก่อน +1

    Comm life 👍

  • @culbyj3665
    @culbyj3665 3 ปีที่แล้ว +3

    USing preforms is the way to go . BAILS FAIL> Some swear they dont but We ve all seen it I think its just laziness that some dont use em. THoughts anyone? seems like you are tensioning as you go. I hope u realize your creating differential stress on the pole. down the road this inhibits cracks and stress. Run your strand then tension it go back and hammer down your clamps. Your creating a hazardous condition. dont do that. You seem to have a great work ethic, dont cheapen your quality. I really dont see you saving much time or effort using 2 guns... come on man. Just get efficient. Ur wrecking a good drill bit in the jaws of that milwaukee. Plus your hand wrenching anyways. geez louis

    • @Popesontour
      @Popesontour 3 ปีที่แล้ว

      Come on! We were running 2 balls of strand on an easy day in Laredo!! These boys need to come down to Texas! See how the big boys play! Don't ever tention each span! Run that fucker dry put a preform on it then Jack all your spans at once!! You're going to break a pole doing this crap!

    • @culbyj3665
      @culbyj3665 3 ปีที่แล้ว +1

      @@Popesontour Thats exactly what is said

    • @BulletSerenade
      @BulletSerenade ปีที่แล้ว +1

      😂

  • @kctyphoon
    @kctyphoon 3 ปีที่แล้ว +9

    I’m 40 seconds in, and see a corded drill is about to be used to drill holes instead of an impact.. Now I’m 4 minutes in, and see he has the cordless impact for the auger bit, but wants to use a drill and a wrench instead.. Now i see him moving the telephone’s company’s guy.. Every bolt in those poles will be loose in a year. Did i really just see a down guy tensioned by stepping on it?????? Maybe not a great idea to be filming yourself in a bucket when your company issues you a harness and you dont wear it.. just sayin guy...

    • @SuperDailey23
      @SuperDailey23 3 ปีที่แล้ว +4

      My first thought was how the setup the first pole to have a straight splice going over the road for no reason

    • @Popesontour
      @Popesontour 3 ปีที่แล้ว

      Man these guys suck bro! Just sayin!

    • @Popesontour
      @Popesontour 3 ปีที่แล้ว

      @@SuperDailey23 no shit! I'm actually dummer after watching this farce! I think they're doing this back ass shit on purpose! They wouldn't last 1 day in Texas!!

    • @davidprivette8898
      @davidprivette8898 2 ปีที่แล้ว +1

      Pretty sure they tensioned the down guy on the pole.

    • @DodgeCharger-d8z
      @DodgeCharger-d8z 9 หลายเดือนก่อน +1

      Let’s not mention primary line limits of approach non insulated work platform , no ground to ground glove work….no truck chalks , no controlled work zone , resident walks into work area while work aloft ….unbelievable

  • @DodgeCharger-d8z
    @DodgeCharger-d8z 9 หลายเดือนก่อน +2

    Lol line life ? Cable tv life …….

  • @DodgeCharger-d8z
    @DodgeCharger-d8z 9 หลายเดือนก่อน +1

    No ground to ground ‘ glove use on primary line pole not controlling you dead end tails …..you’d be gone in seconds fired and fined in a civilized operation my man …..you bandwidth broncos arnt even in an insulated platform ? On primary poles during limits of approach? Absolutely nuts in the melon !

    • @AllanS69
      @AllanS69 8 หลายเดือนก่อน

      What’s “ground to ground glove use”
      Serious question.
      Also telecom lineman don’t typically need an insulated platform, as we don’t fuck with power.
      As long as you used your voltage tester on the steel and find that it’s safe. You are good to go.

    • @DodgeCharger-d8z
      @DodgeCharger-d8z 8 หลายเดือนก่อน

      @@AllanS69 insulated gloves from start to finish Ariel work at limits of approach

  • @miroslavzatko1477
    @miroslavzatko1477 ปีที่แล้ว +1

    slabe, chudak.

  • @Kurt.Wallander
    @Kurt.Wallander 2 หลายเดือนก่อน

    horrible solution using old and dangerous poles... in Europe we are more serius.... all the cables are underground