How to remove a lead joint form Cast iron drain and connect to pvc pipe

แชร์
ฝัง
  • เผยแพร่เมื่อ 11 ส.ค. 2020
  • In this we show you how to remove a lead joint and attach 4" PVC to 4" cast iron pipe.
    #kevinrobinson6688 #CastIronToPvc #AttachPvcToCastIronPipecast
    Flex Coupl 4"Ci Hub X 4" amzn.to/2POHrix
    As an Amazon Associate, I earn a small commission from qualifying purchases.
    This will not, however, change the price of any product you purchase.
    This helps support the channel and allows me to continue to make videos.
    Thank you for the support!
    Keep it real & clean.
    All donations are appreciated thank you for your help.
    Help Support My Channel paypal.me/kevinrobinson6688 Thank You.
    Mailing address
    kevinrobinson6688 P.O.Box 123 Bobtown,PA 15315-0123
  • บันเทิง

ความคิดเห็น • 499

  • @MrSandu13
    @MrSandu13 3 ปีที่แล้ว +7

    Finally a good video to cover this topic. Thanks. And thanks for not wasting everyone’s time with jazz about non related issues.

  • @birddog7248
    @birddog7248 2 ปีที่แล้ว +45

    I am a self-employed plumber in New York State with 34 year's experience. I was taught as a helper from my uncle Vinny to do it the torch way. It takes forever and is very messy, especially up in a rafter. I learned the drill and chisel trick and I like MUCH better

    • @DJjosher
      @DJjosher 2 ปีที่แล้ว +4

      Drill and chisel sound better. The smell of lead isn't good.

    • @hjander
      @hjander ปีที่แล้ว +3

      Kevin is working on a cement floor and next to a brick wall, which is more safe than using a torch in an area surrounded by or in proximity to wood.

    • @twinkie27271
      @twinkie27271 ปีที่แล้ว

      Problem is, the cast iron absorbs the heat, and lead doesn't want to melt. You can't do this with a propane torch. It just doesn't get hot enough.

    • @truth6600
      @truth6600 9 หลายเดือนก่อน +3

      The new trick is to saw the c/o flat,take a hole saw put it over the hub and drill out,really fast.

    • @kennethwilson1117
      @kennethwilson1117 7 หลายเดือนก่อน

      I agree with both but your way is easier because lead is soft👍🏾

  • @nicholasmiller8508
    @nicholasmiller8508 ปีที่แล้ว +2

    Thank you so much for this. Just found a strange combo of lead/oakum joint used for cast iron to PVC. had to remove that and replace this. Thanks.

  • @Hatch61
    @Hatch61 3 ปีที่แล้ว +7

    It’s tough, because that big old pipes just sucks the heat away. Tough to get it flowing. Nice job my friend, you are right, PVC is so much easier. Thanks for the video Kevin, be well my friend.

  • @andiroyal4752
    @andiroyal4752 3 ปีที่แล้ว +3

    Simple and clear video. Keep up the good work.

  • @PaulBabesDotCom
    @PaulBabesDotCom 3 ปีที่แล้ว +9

    Getting ready to do a similar project myself. Always good to watch someone else do it beforehand.....I'm thinking maybe a combination of drilling and torching, maybe?.....Now I'd like to see a video of a plumber putting those pipes together from way back when! They would be so envious watching us glue PVC pipes together today!

    • @Robinson-Homestead
      @Robinson-Homestead  3 ปีที่แล้ว

      good luck on you project and make sure to have plenty of ventilation.

    • @Joe_Brown99
      @Joe_Brown99 2 ปีที่แล้ว

      Yeah I bet that had to stink!

  • @hugoballs
    @hugoballs ปีที่แล้ว +2

    This is gold. thank you so much for showing how its done.

    • @Robinson-Homestead
      @Robinson-Homestead  ปีที่แล้ว +1

      Your welcome just be careful working with lead joints

  • @alfredocardenas4702
    @alfredocardenas4702 2 ปีที่แล้ว +2

    Thank you very much for teaching all of us 😉🙏🤜🤛

  • @TheWoodHaven
    @TheWoodHaven 3 ปีที่แล้ว +4

    Never seen that done before. Great information.
    Thanks for the video.

    • @Robinson-Homestead
      @Robinson-Homestead  3 ปีที่แล้ว

      I'm not sure that I did it right but it done and it works great thanks Daryl.

    • @dodibyrne6305
      @dodibyrne6305 2 ปีที่แล้ว

      How do you fasten it in place?

  • @gerardbauer4035
    @gerardbauer4035 3 ปีที่แล้ว +2

    Job well done. Cool video. Very informative. Thanks for sharing.

  • @stormbytes
    @stormbytes 3 ปีที่แล้ว +4

    You're my friggin hero!!

  • @paulwilliams6753
    @paulwilliams6753 3 ปีที่แล้ว +5

    Nice Jon Kevin, I learned a lot from your video! 👍👍

  • @jimpritz4169
    @jimpritz4169 3 ปีที่แล้ว +9

    Our first house built in 1945 had that leaded pipe in it. Luckily I never had to mess with it. It also had threaded brass water pipes something you never see in today's world. Great job Kevin be careful working with that lead I think it's made everyone in California crazy.

    • @Robinson-Homestead
      @Robinson-Homestead  3 ปีที่แล้ว

      I just had that one to work on hope no more Jim I am filling a little crazy lol.

    • @kendallwillis
      @kendallwillis 3 ปีที่แล้ว +4

      LOL, we're in California and my 1962 home still has lead and oakum plumbing. Good ol' union work. And some of it is ready to get replaced with PVC. Wear a respirator

  • @scottdahl3975
    @scottdahl3975 2 ปีที่แล้ว +1

    Great video, Could’ve used it several years ago when I did a similar transition. Thanks!

  • @MK-xl9tt
    @MK-xl9tt 3 ปีที่แล้ว +8

    Being a plumber for 30 years these diy videos are very entertaining

    • @MK-xl9tt
      @MK-xl9tt 3 ปีที่แล้ว +9

      To correct my typos I would NOT recommend a street or (spigot) type fitting for inserting into cast iron hub, use a piece of pipe

    • @Robinson-Homestead
      @Robinson-Homestead  3 ปีที่แล้ว +1

      Thanks for the comment

    • @1hiphopnow
      @1hiphopnow ปีที่แล้ว

      @@MK-xl9tt pvc pipe?

  • @llewellynjones8201
    @llewellynjones8201 2 ปีที่แล้ว +2

    Proves that if you have a lot of patience to stick with heating the cast iron, it will come free. Thank For This.

    • @Robinson-Homestead
      @Robinson-Homestead  2 ปีที่แล้ว

      You bet thanks for watching

    • @birddog7248
      @birddog7248 2 ปีที่แล้ว

      It is ALOT faster with a TURBO torch tip, but most residential plumber's do not have or need a torch that gets that hot

  • @PaulDGreen-bu4iz
    @PaulDGreen-bu4iz 3 ปีที่แล้ว +3

    That lead can be a problem to get out. Great job Kevin! Thank you for sharing!

  • @ptech88
    @ptech88 6 หลายเดือนก่อน

    I have done this a lot. I use an acetylene torch with a really big tip. I kinda find it relaxing watching the lead melt.

  • @xiaoyuezhang338
    @xiaoyuezhang338 2 ปีที่แล้ว +1

    Great video man! this video was super helpful.

  • @akeemhoque5976
    @akeemhoque5976 2 ปีที่แล้ว

    Thank you very much!

  • @MK-xl9tt
    @MK-xl9tt 3 ปีที่แล้ว +21

    Thank you for taking the time and effort to make this video. To the comment section I would recommend a4” ez tight gasket,piece of 4” schedule 40 pipe and a schdule40 4” 45. St 45s or 90s are the best type of fitting for this connection, a short piece of pipe should be used to insure it extends through gasket and hits bottom of cast iron hub. the gasket here looks to be very loose. This connection with a proper gasket never goes in easy with minimal force. Use an ez tight or multi tight,take the edge off the end piece to insert and lube it up, you will know when it a good seal. To take out the old cast iron hub, chisel out brass cap, split inside of cast iron insert, chisel sides in and remove. I would shove a rag in the pipe to prevent and pieces from falling into line during this process

    • @Robinson-Homestead
      @Robinson-Homestead  3 ปีที่แล้ว

      Thanks for the comment

    • @jakester455
      @jakester455 9 หลายเดือนก่อน

      I know this is an older comment, but how do you split the cast iron insert?

    • @MK-xl9tt
      @MK-xl9tt 9 หลายเดือนก่อน +1

      I cut a notch on the inside of the pipe. One on either side with a sawzall and cast iron blade.
      Cut from inside of the pipe through to the lead as much as you can without hitting the hub.
      When you have at least (2) notches chisel the pieces toward the middle.
      I always put a balled up rag down inside the pipe to keep the pieces from falling into the drain line.

  • @adk1guy
    @adk1guy 2 ปีที่แล้ว +4

    Its been many decades since I had to do this but I have one to do again now so I'm watching videos. I don't like the torch method and I don't much like the drill method either. I think I used to break the pipe or fitting one inward one chip at a time using a cold chisel , and then use the chisel to pry the lead toward the center and once started it came out easy. Then, because they didn't yet make ferncos, or rubber donuts, or no hub connectors, we had ABS to CI fittings with a spigot, caulked in oakum, then packed in lead wool which you could pack back into a solid with caulking tools which look like off set chisels but the are flat on the end. I ' just a kid and the real plumbers were still ladling molten lead into the joints.

    • @xraceboyex
      @xraceboyex 2 หลายเดือนก่อน +1

      I was trying to figure out what the last guy did to my 1-1/4" sink drain and I think the method you described was it haha. Never seen anything like it. Thanks for this comment, I never woulda figured that out without finding a comment/thread like this

  • @pbdempster
    @pbdempster 3 ปีที่แล้ว

    Thank you for the info Paul Shoshoni, Wyoming

  • @user-xm7dt3ec1o
    @user-xm7dt3ec1o 3 ปีที่แล้ว +1

    非常に参考になります。

    • @Robinson-Homestead
      @Robinson-Homestead  3 ปีที่แล้ว +2

      I wish I knew how to translate this thank you for the comment.

  • @samhooley1915
    @samhooley1915 ปีที่แล้ว +40

    You've got a schedule 35 pvc fitting, which the fernco donut isn't designed for. You need to use 4" ABS or 4" schedule 40 fittings, which will be a little larger in diameter and fit tighter in the donut.

    • @Robinson-Homestead
      @Robinson-Homestead  ปีที่แล้ว +1

      Thanks for the information.

    • @alski259
      @alski259 ปีที่แล้ว

      Agreed!

    • @bigmike3964
      @bigmike3964 ปีที่แล้ว

      i noticed that too

    • @anthonygrant7952
      @anthonygrant7952 ปีที่แล้ว +1

      I was noticing that. Wondering if the iron being hot had expanded it a little like taking bearing races off of a car

    • @chicagolandbrokersrobertno3553
      @chicagolandbrokersrobertno3553 ปีที่แล้ว +1

      Looked loose to me too. That explains it.

  • @dannydunnagan3267
    @dannydunnagan3267 3 ปีที่แล้ว

    Good job Kevin never saw that done before around her everything is plastic in the cities they have a lot of that pipe.

    • @Robinson-Homestead
      @Robinson-Homestead  3 ปีที่แล้ว

      This is the first time working on this kind of pipe for me Danny I think I did ok thanks.

  • @masteringalltrades8144
    @masteringalltrades8144 3 ปีที่แล้ว +4

    Thank you so much for naming this piece. I couldn't find it online because I couldn't find the name.

    • @Robinson-Homestead
      @Robinson-Homestead  3 ปีที่แล้ว

      Thanks for the comment and watching glad to help.

    • @edwithkowski8330
      @edwithkowski8330 3 ปีที่แล้ว +1

      Yes Mapp gas is hotter But 2 small tanks of Oxy Acetylene it takes half the time! But only if theyr available to you??

  • @kennethwilson1117
    @kennethwilson1117 7 หลายเดือนก่อน +1

    Great job 👍🏾

  • @TomokosEnterprize
    @TomokosEnterprize 3 ปีที่แล้ว +3

    I remember when leading was still taught in apprenticeships. It outlasted the iron for sure. Good post bud. I hope you didn't breath too much of that lead in.

    • @Robinson-Homestead
      @Robinson-Homestead  3 ปีที่แล้ว

      I had a fan on hope not to thanks Dean.

    • @TomokosEnterprize
      @TomokosEnterprize 3 ปีที่แล้ว

      @@Robinson-Homestead Lead is the least of all the nasty metals for sure. I am just partial to silver but that would be a pricy thing. I am home now from the amputation and feeling better than I have in over 20 years.It will be great to get back to my pouring bench and handling the repairs and welding at the ranch. Life is good now.

    • @bentnickel7487
      @bentnickel7487 3 ปีที่แล้ว +1

      @@TomokosEnterprize I follow your channel. So sorry about your right leg, but if you feel better, that's the most important thing. Really admired that silver chess piece.

    • @TomokosEnterprize
      @TomokosEnterprize 3 ปีที่แล้ว +1

      @@bentnickel7487 Hey Brent. How nice of you to stop by. The leg was an awful thing that consumed my waking hours. Now I have a fresh lease on life nearly pain free. It was a good thing my friend.

  • @Cristoviveenmi1977
    @Cristoviveenmi1977 3 ปีที่แล้ว +1

    Great job

  • @jordandomingo9750
    @jordandomingo9750 3 ปีที่แล้ว

    very informative dude!

  • @luiselias1887
    @luiselias1887 2 ปีที่แล้ว

    thank you so much for this video

  • @jameymote4598
    @jameymote4598 3 ปีที่แล้ว

    Great video 😎 👍 ✌

  • @ThatGuyFromNantucket06
    @ThatGuyFromNantucket06 3 ปีที่แล้ว +5

    I usually just drill out the lead. After enough holes, the fitting will spin right out. It saves on gas and protects you from the fumes if you don't have proper ventilation.

  • @plumbcrazy375
    @plumbcrazy375 2 ปีที่แล้ว +2

    You have more patients than me I use a grinder split the plug in half than pop the plug out make a little deeper cut use two Hammers and crack the clean out in out than the lead and oakum comes right out old school plumber

  • @garyburgess3829
    @garyburgess3829 3 ปีที่แล้ว +1

    My home place here in n.c. still has that kind of pipe in it. It was built in 1960.

  • @poncianoarriaga9762
    @poncianoarriaga9762 28 วันที่ผ่านมา

    Me agrada mucho que comparta sus experiencias, felicidades AND gracias.

  • @brianb8163
    @brianb8163 10 หลายเดือนก่อน +3

    Nice job. An alternative method is to drill out the lead. Get about 5 drill bits an 1/8 in in diameter and start drilling holes all around the joint. Expect to break several of them. Takes about 20 minutes and you will have drilled enough lead out that you can wiggle the joint out by hand. I have used this technique several times on 4 inch cast iron pipe in my home. It works well. Be sure to measure the joint and get the right size fernco fitting.

    • @Robinson-Homestead
      @Robinson-Homestead  9 หลายเดือนก่อน

      Thanks for the info.

    • @jakester455
      @jakester455 9 หลายเดือนก่อน

      I love it when the commenter didn't watch the video. LOL (he mentioned the process you suggested at the beginning and explained why he wasn't doing it)

  • @123Goldhunter11
    @123Goldhunter11 ปีที่แล้ว

    Good job. I'm confronted with a 4" soil pipe as I replace an old septic tank.

    • @Robinson-Homestead
      @Robinson-Homestead  ปีที่แล้ว

      Good luck my friend thank you for the comment and watching.

  • @RayLandry
    @RayLandry 3 ปีที่แล้ว

    Nice job

  • @Homepros888
    @Homepros888 3 ปีที่แล้ว +8

    A lot of plumbers just call that a "Donut" after you put the donut in the hub and you was able to put the pvc pipe in easily I think you should have got the heavy weight one. Because usually it should show some restrictions for it to be water tight.

  • @JTTTTx
    @JTTTTx ปีที่แล้ว +4

    Old Plumber here-You have the wrong fitting. You need schedule 40 and grease.
    Also you need to install a new clean out immediately adjacent to the one that you removed. Check out the code.
    Lastly, back in the day, the lead joints were removed either with a lead pick( I have one) or with the fire pot that kept the lead ready for the joints on the job.

    • @MyView0714
      @MyView0714 3 หลายเดือนก่อน +1

      New plumber here-You think he’d notice it didn’t seal. SDR fitting, when it clearly says DWV (Sch 40). Should have called a plumber.

  • @jetrick105
    @jetrick105 3 ปีที่แล้ว +3

    I did the drill method, same result in the end.

  • @hado11
    @hado11 2 ปีที่แล้ว

    Hard work.

  • @kennethwilson1117
    @kennethwilson1117 7 หลายเดือนก่อน

    You are right with the heat I found out the hard way 😂

  • @fullmoon5739
    @fullmoon5739 3 ปีที่แล้ว +54

    Please be advised, you must wear a respirator, the fumes from the lead can be very toxic, that's why we don't have any old plumbers around who installed lead joints. Also let's not forget that methane gas is very flammable.

    • @Robinson-Homestead
      @Robinson-Homestead  3 ปีที่แล้ว +7

      good information thank you

    • @jacksplumbingvideos7147
      @jacksplumbingvideos7147 3 ปีที่แล้ว +9

      there is one left named roger wakfield

    • @jlit6428
      @jlit6428 3 ปีที่แล้ว +7

      Yeah when he said heat up I was like oh no Methane, please work out please work out. That Methane really concerned me.

    • @tfoen7678
      @tfoen7678 3 ปีที่แล้ว +3

      @@jacksplumbingvideos7147 this old house sure gets his value of plumbing by the $$$

    • @BiffSarin
      @BiffSarin 2 ปีที่แล้ว +10

      Y’all are making too big a deal about the methane. If the methane explodes, then the fitting blows itself out of the joint. Problem solved!🤣🤣🤣
      PS. You may want to wear a blast shield over your respirator!😆

  • @DavidTorres-tw8kv
    @DavidTorres-tw8kv 3 ปีที่แล้ว

    Thanks

  • @3melendr
    @3melendr 3 ปีที่แล้ว +7

    Melting lead is safer than drilling if you use a respirator. Drilling produces tiny fragments that are more difficult to clean up. I wonder if heating up the outside of the cutout with a hotter gas would speed up the melting process. Nice video. I will be replacing some cast iron pipe in my 104 year old house soon.

    • @Robinson-Homestead
      @Robinson-Homestead  3 ปีที่แล้ว

      Thanks for watching and be safe with your project.

    • @twinkie27271
      @twinkie27271 ปีที่แล้ว

      Oxyacetylene or oxypropane would work much better. Cast absorbs all the heat, and the lead doesn't want to melt.

  • @gatorsworld
    @gatorsworld 3 ปีที่แล้ว +1

    You did real good with that lead Kevin....Once you got her loose she just had to come....I have seen my father do some of that pipe with some kind of string packed in all around...I think I still have the packing chisel....You just can`t beat the new stuff but I wonder if it`s going to last as long....good job....CHEERS

  • @cs-bs3fu
    @cs-bs3fu 2 ปีที่แล้ว +1

    Glad I found your video, was curious just how much lead I might have to deal with on my project, I would suggest you post on the other sites like Odysee because a lot of folks have dumped youtube over their partisan bullshittery. If I wasn't in a pinch, I would never have clicked, have a nice day.

  • @bobbing5788
    @bobbing5788 3 ปีที่แล้ว

    Excellent video definitely Subscibe 👍

  • @MatthewLouisHauser
    @MatthewLouisHauser 3 ปีที่แล้ว +7

    Although I could be wrong, I believe the reason the PVC fitting is loose is because it’s a “Street” elbow, which means its outside diameter is 4 inches, and the rubber adaptor is expecting the normal outside diameter of 4.5 inches. I imagine if he stuck a normal piece of 4 inch PVC pipe in there, the fit would be very snug.

    • @Robinson-Homestead
      @Robinson-Homestead  3 ปีที่แล้ว +1

      thank you for the comment

    • @Robinson-Homestead
      @Robinson-Homestead  3 ปีที่แล้ว +1

      @@davidramey7186 sorry your right about Street elbow it has been working ok no small or leeks thanks for the comment.

    • @crazyhass84
      @crazyhass84 ปีที่แล้ว

      Correct. His install would fail an inspection! Which we know code is the bare minimum... not the top notch. So not even passing code is a major red flag

    • @r777v
      @r777v ปีที่แล้ว +2

      Street is same size as OD

    • @MatthewLouisHauser
      @MatthewLouisHauser ปีที่แล้ว +2

      @@r777v No, the street size would be the same as the ID, not the OD.

  • @canneddirt
    @canneddirt 3 ปีที่แล้ว +7

    my main concerns with this method of removal is lead vapors and possibly setting the oakum aflame.

    • @Robinson-Homestead
      @Robinson-Homestead  3 ปีที่แล้ว

      Yes be very careful.

    • @jonmpb578
      @jonmpb578 3 ปีที่แล้ว

      Used oakum is soaked so expands to seal the pipe, making it non burnable. Dried out oakum, like above all the sinks, will burn. Lit some the other day. (accidentally). No stink pipe odors 👍

  • @tubalcain1
    @tubalcain1 ปีที่แล้ว +2

    Thanks!!
    So how does the rubber hub get completely sealed to the cast iron and then to the pvc fitting?? Everything seemed a little lose when you test fit it.
    Is there a glue of some sort?

  • @LoveGuitar63277
    @LoveGuitar63277 ปีที่แล้ว +1

    Try a flywheel/crankshaft puller to grab the piece to be removed.

  • @bernard0550
    @bernard0550 ปีที่แล้ว +1

    Tx . I have similar job to do , but 2inch to cast iron

  • @bentnickel7487
    @bentnickel7487 3 ปีที่แล้ว +21

    Between the methane and lead oxide fumes, drilling is slower but safer, according to my retired plumber buddy. The union strictly prohibits the melting of lead.

    • @Robinson-Homestead
      @Robinson-Homestead  3 ปีที่แล้ว +1

      Good information Bent Nickel thank you for the comment glad I only had one to do.

    • @patmadix172
      @patmadix172 3 ปีที่แล้ว

      Amen. Removed many a joint.

    • @MK-xl9tt
      @MK-xl9tt 3 ปีที่แล้ว +2

      The union🤣

    • @treystills
      @treystills 2 ปีที่แล้ว

      curious...how does the lead get in the joint initially? thx

    • @jrnelson8085
      @jrnelson8085 ปีที่แล้ว +3

      @@treystills its melted in a little pot and poured in

  • @bflkurby1
    @bflkurby1 2 หลายเดือนก่อน +1

    Idk what is in PB BLASTER but that has made ALOT of jobs easier.

    • @Robinson-Homestead
      @Robinson-Homestead  2 หลายเดือนก่อน

      It does work thanks for the comment.

  • @nagadsby9413
    @nagadsby9413 หลายเดือนก่อน +1

    I took out a 4” vent pipe, all the packing, and all the lead with a small centerpunch and small chisel in less than two minutes. Severely rusted pipe as well. Much faster.

  • @devster12
    @devster12 3 ปีที่แล้ว +27

    From my experiences its quicker and safer to drill most of the lead and oakum out instead of melting it out

    • @Robinson-Homestead
      @Robinson-Homestead  3 ปีที่แล้ว

      Good tip

    • @hendonburgism
      @hendonburgism 3 ปีที่แล้ว +4

      When you drill it, you send tiny lead and lead oxide particles and dust everywhere, while it may or may not be more safer, simply keep that in mind.

    • @RussianOZ
      @RussianOZ 2 ปีที่แล้ว +3

      @@hendonburgism wear a mask, goggles, and gloves. Use a small chisel and a drill. Works great. I’ve done a few jobs like that - and have been told by others not to heat it up the fumes are way more dangerous, plus work like that would be in a place that has cast iron piping, which means it would be at least +40-90 year old drain…. Those things usually come off very easy

    • @BiffSarin
      @BiffSarin 2 ปีที่แล้ว +6

      @@RussianOZ “which means it would be at least +40-90 year old drain… Those things usually…” are also surrounded by +40-90 year old lumber!!!
      In this case, the OP is working around cinder block. In many (if not most) cases, that pipe will be surrounded by very old lumber…which is EXTREMELY dry and tends to burn like a matchstick.
      To make matters worse, homes built 75-90 years ago (especially in the South) were almost exclusively built with old growth heart pine. This wood has a very high pitch content which makes it basically impervious to termites…it also makes it highly flammable when it dries out. Think “fat lighter”!

    • @RussianOZ
      @RussianOZ 2 ปีที่แล้ว

      @@BiffSarin that’s crazy. I didn’t know. I have moved to United States a few years ago. And just came across a few projects up north “Ohio” where some of these have “lead seal”
      Wood and a direct fire is a good way to have your insurance company involved…

  • @hermanrogers1325
    @hermanrogers1325 2 ปีที่แล้ว +2

    On my house I used WD-40 and pipe wrench with a breaker bar

  • @elijahgoodman3140
    @elijahgoodman3140 2 ปีที่แล้ว +2

    Do you have to put glue between the boot and pvc fitting or the boot and cast iron? Just don't know where the seal is?

  • @JuanRodriguez-vi9ee
    @JuanRodriguez-vi9ee 3 ปีที่แล้ว

    Hi
    Thank you to show how to chainge from cast to Pvc. Do you have any video of the same but in a bathroom sink wall drainish?

  • @vasybaron7797
    @vasybaron7797 6 หลายเดือนก่อน +1

    Very well explained...Thank you.I still have a question: Is that tight enough to seal perfectly? I have seen some guys using 4" regular PVC pipe and just make a bevel to the end which inserted in to make it tighter?

  • @Pete.Ty1
    @Pete.Ty1 3 ปีที่แล้ว

    😊👍

  • @Birdkillersteve
    @Birdkillersteve 2 ปีที่แล้ว +2

    You’ll want to be careful using an open flame as sewer lines can have flammable gasses in them. You could go boom!

  • @richardj5417
    @richardj5417 3 ปีที่แล้ว

    Education is key this is great for a home owner or to save a buck maybe. But honestly not much in the scheme of things. Could be better.

  • @mynonameyt
    @mynonameyt ปีที่แล้ว

    Good info, I've done this before. It sure seemed like you pvc went the rubber boot easy. To easy, did it leak? Mine went on super tight, I had to pound it in with a 2x4 and hammer.

  • @jaymantwothree1925
    @jaymantwothree1925 3 ปีที่แล้ว +4

    Nice work! The plumber who soldered that in probably rolled over in his grave

    • @Robinson-Homestead
      @Robinson-Homestead  3 ปีที่แล้ว +2

      lol he may be but i needed to fix it.

    • @RussianOZ
      @RussianOZ 2 ปีที่แล้ว

      Those a usually stuffed - it works like a putty however thicker and stronger.

  • @jeromegarcia5396
    @jeromegarcia5396 2 ปีที่แล้ว

    Lucky my last cast iron pipe I had to deal with had duct tape... Lol no joke, I got a rubber cuplink and that was that...

  • @HongNguyen-rz2uv
    @HongNguyen-rz2uv ปีที่แล้ว +1

    Great super video, thanks.
    Why there was led in there ? Anyone know can answer for me please?

  • @elijahgoodman3140
    @elijahgoodman3140 2 ปีที่แล้ว

    Could you use the conversion if your piped were horizontal?

  • @anthonygrant7952
    @anthonygrant7952 ปีที่แล้ว

    I've often wondered if it would be possible to make an induction field around the hub the same way induction stove works

    • @georgejetson4378
      @georgejetson4378 6 หลายเดือนก่อน

      Sure. It’s possible. How much time, money, and know how do you have?

  • @alski259
    @alski259 ปีที่แล้ว +1

    I don't know. I'll go with the drill bit and pick at it. Map gas is way more expensive than a couple of 1/4 inch bits too. Time wise I think is a wash as well.

  • @juddbrady1825
    @juddbrady1825 3 ปีที่แล้ว

    Thought you was smelting for a second there!

  • @sarahsun4387
    @sarahsun4387 3 ปีที่แล้ว +1

    nice video and thank you. mine doesn't have the lead joint, copper connects to the cast iron directly and stuck. any suggestions? thanks a lot.

    • @sarahsun4387
      @sarahsun4387 3 ปีที่แล้ว

      @Joe M thank you very much.

    • @Robinson-Homestead
      @Robinson-Homestead  3 ปีที่แล้ว

      I heated mine but could not break it loose it saw seized in there.

  • @samsen3965
    @samsen3965 2 ปีที่แล้ว

    Can you show how you put the rest on the other side and create a new clean-up access or whatever that connects to the other end? Thanks for sharing.

  • @_CAT-lg4sr
    @_CAT-lg4sr 5 วันที่ผ่านมา

    The soil pipe hub seal requires the full O.D. of a 4" PVC pipe to fit correctly and make a tight seal. Chamfered on the end, lubricated with some soapy water and with much effort, forced into place to assure a tight seal. If the reduced end of the slip-fit 45 degree fitting, as shown in the video is used in there, it won't provide a very good seal. Could leak both liquids and sewer gases.

    • @Robinson-Homestead
      @Robinson-Homestead  2 วันที่ผ่านมา

      No issues so far but thanks for the info

  • @shanestamball1886
    @shanestamball1886 5 หลายเดือนก่อน +1

    Some guys always wanna do things the hard way, we still do iron & caulk work. Aswell as lead pipe in historical building's and on boats.
    Drilling n hook is the only method to remove this,

  • @josephlatourette8329
    @josephlatourette8329 3 ปีที่แล้ว

    It makes sense that you would use heat to get the plugs off when they use heat to put it on originally

    • @Robinson-Homestead
      @Robinson-Homestead  3 ปีที่แล้ว

      It worked for me just fine, thanks for watching.

  • @sjohnson5813
    @sjohnson5813 3 หลายเดือนก่อน +1

    So much easier to use a carbide toothed hole saw bit...trust me. I do it all the time. Been plumbing almost 20 years and I own my own small business. I exclusively do remodels and service. Try it and you will see. Fk doing the torch method and the drill bit method

    • @Robinson-Homestead
      @Robinson-Homestead  3 หลายเดือนก่อน

      Thanks for the comment.

    • @MrRidery2g
      @MrRidery2g 2 หลายเดือนก่อน

      What size of hole saw

    • @MrRidery2g
      @MrRidery2g 2 หลายเดือนก่อน

      For a 2 inch hub

  • @bjkjoseph
    @bjkjoseph 9 หลายเดือนก่อน +1

    I haven’t done plumbing in 30 years but that rubber thing we used to call dual tights and you have to grease it and it’s really hard to put it. I have no idea what you were using but that’s gonna leak like a sieve.

    • @Robinson-Homestead
      @Robinson-Homestead  9 หลายเดือนก่อน

      Thanks for the comment has been working great so far no leaks.

    • @tempesttube
      @tempesttube 4 หลายเดือนก่อน

      @@Robinson-HomesteadYou probably wouldn’t have leaks until it backs up. Imagine two straws, one with a smaller diameter than the other. They fit loosely together. You connect them with the bigger one on the bottom. If you pour water into this assembly, you wouldn’t have a leak. Then you plug the bottom and pour enough water for the water to back up above the joint. Now you have a leak.

  • @kennethwilson1117
    @kennethwilson1117 7 หลายเดือนก่อน

    Put your flame 🔥 more on the hub 😮

  • @danlabonty9720
    @danlabonty9720 2 ปีที่แล้ว

    I believe you had a street elbow/fitting. I pretty sure the service weight hub you slid into the cast iron should have a full diameter 4 inch pvc slid into it. You should have to bevel the edges to get it started and there should still be a good bit of compressive resistance trying to slide it in. Usually have to put petro jelly on the pvc I usually use silicone as it makes it slide in easy and help seal once cured. Just my 2 cents.

    • @Robinson-Homestead
      @Robinson-Homestead  2 ปีที่แล้ว

      Thanks for the comment and watching

    • @danlabonty9720
      @danlabonty9720 2 ปีที่แล้ว

      @@Robinson-Homestead yup ,anytime . This is how we all learn. Specially tips and tricks to make life easier.

    • @Fresh-tw7ev
      @Fresh-tw7ev 2 ปีที่แล้ว

      Dan that is what I need but don’t know where to look for such a thing. And when I do find the proper hub I don’t know what pipe cap to purchase that won’t blow out if the sewer builds up pressure. Any good videos to show a horizontal application? P.S. I actually discovered the clean out cap to the soil pipe had corroded open and was letting sewer gas into the house.

    • @danlabonty9720
      @danlabonty9720 2 ปีที่แล้ว +2

      @@Fresh-tw7ev don't know where you are located. If midwest menards carries them forsure. Home depot as well. Or a local plumbing supply house. There should be no pressure in the drain lines. If there was you would hear the sinks or toilets bubbling. If you are having sewage problems. They make a sewage back flow preventer valve which only allows sewage to go one direction.

  • @twolfe4295
    @twolfe4295 3 ปีที่แล้ว +3

    How I remove lead....unscrew c.o. plug.....insert rag to protect inside of pipe form debris....use reciprocating saw to cut c.o. fitting...cut fitting in two places and drive chisel into edge to spread fitting inward...remove c.o. fitting...cut out lead very easily and remove....saves
    your lungs and the atmosphere from all that heated lead, oakum, and stink.

    • @Robinson-Homestead
      @Robinson-Homestead  3 ปีที่แล้ว

      I couldn't get the c.o. plug unscrewed thanks for the info.

    • @MK-xl9tt
      @MK-xl9tt 3 ปีที่แล้ว

      @@Robinson-Homestead hammer and chisel

  • @edwards2990
    @edwards2990 ปีที่แล้ว

    take 1/4 inch copper tubing Create a COIL around the unit hook the 2 end's to a 120 Volt . should be more then enough to Melt the Lead seal .

  • @newunderthesun7353
    @newunderthesun7353 2 ปีที่แล้ว +2

    You need to finish the job before ending the video. Or change the title to "Remove A Lead Joint" and leav it at that.

  • @pipehanger
    @pipehanger ปีที่แล้ว +1

    Pls try to use a 1/4" drill bit and a flat head screwdriver. will be a lot faster.

  • @maxwellhouse1902
    @maxwellhouse1902 หลายเดือนก่อน +1

    Has anyone tried using one of those Induction Heaters for this job? Seems like a good test for it

    • @Robinson-Homestead
      @Robinson-Homestead  หลายเดือนก่อน +1

      No i haven't but it would be nice to know if it would work, thanks for the comment.

  • @dennisaliano7249
    @dennisaliano7249 3 ปีที่แล้ว

    Kevin I'm going to do a job exactly like the one you showed in the video. Do you have to seal the boot with anything before you shove it in the cast iron. I'm thinking maybe sewer gas leaking around the boot?

  • @samsen3965
    @samsen3965 2 ปีที่แล้ว +2

    At the end 14:55 : How the boot will stay in place without leaking? Are you going to glue? as I don't see any means for pressure tightening.

    • @MyView0714
      @MyView0714 3 หลายเดือนก่อน +1

      Not the right fitting he had a SDR fitting, needs DWV. With the proper fitting it will seal just fine.

  • @craigwyss6035
    @craigwyss6035 ปีที่แล้ว

    ASBESTOS...the packing is made from ASBESTOS, we just removed some from an 1929 house, we filed an nopa and followed worksafe guide lines.

  • @johnhouli3450
    @johnhouli3450 ปีที่แล้ว +1

    Thanks Kevin, my cast iron black pipe goes up through my attic and the septic smell is coming out of the connections of two black iron pipes that were once joined by lead. The lead seems to have lifted up. So I removed and now I placed mortite puddy all around to try and stop the smell. It seems to have worked.
    What would you have done.

    • @Robinson-Homestead
      @Robinson-Homestead  ปีที่แล้ว +2

      Put a rubber sleeve over it with hose clamps.

    • @johnhouli3450
      @johnhouli3450 ปีที่แล้ว

      @@Robinson-Homestead unable to use that unless I cut it in half. And use clamps.

  • @johnhoover249
    @johnhoover249 3 ปีที่แล้ว +1

    Is a bell & spigot joint the same as a hub & barrel joint? I am confused because I hear bell and hub used interchangeability.

  • @rickeykeeton4770
    @rickeykeeton4770 2 ปีที่แล้ว

    I have learned a lot from TH-cam videos, but I usually do more research including watching several in the same subject and not go by the first I see.
    There have been a lot of people watch this one.
    I hate to make a negative comment, it might save someone from getting hurt and or doing more damage.
    I have to wonder how many have tried this and gotten hurt or caused more problems!
    No plumber here but no way would I leave that connection that loose.
    Op’er, no need to thank me for my comment.

  • @johnkrim8377
    @johnkrim8377 3 ปีที่แล้ว +1

    Love the smell of burnt oakum in the morning . 👷🏻

  • @tunnelboy777
    @tunnelboy777 3 ปีที่แล้ว

    Was wondering about melting, but was concerned about sewer gases. My 4" connection is wide open. Drilled it and it was actually fairly easy and quick. Question: Our city does NOT allow PVC or ABS plastic, so I have to connect cast iron to the hub. Do they make a doughnut for that size? Is that the correct way to do the connection? Or do I get a fitting (like a reducer) that covers the OD of the old hub and connects normally to the new CI pipe?

    • @Robinson-Homestead
      @Robinson-Homestead  3 ปีที่แล้ว

      sorry tunnelboy but i don't know about that

    • @tunnelboy777
      @tunnelboy777 3 ปีที่แล้ว

      @@Robinson-Homestead Thanks for the response. Yes, I found out there is a donut for CI to CI hub and it works really well. Not sure why my dumb city doesn't allow plastic while the rest of planet earth does, but that's another topic. Sounds like a little payola action with the cast iron company.

    • @Timah0212
      @Timah0212 3 ปีที่แล้ว +2

      @tunnelboy777 they don't allow it because plastic is toxic in a fire. It why we switched from abs to pvc in the 80's

    • @davepetrakos475
      @davepetrakos475 ปีที่แล้ว

      My house was outfitted with city sewer circa 1908. Walt Disney's house had the same about a mile away. Iron was probably dragged in behind donkeys and oxen from the rail yard. It still works, sort of. Rust is causing perforations.
      NOW LET US TALK about PVC. it's expected life is 70 years, falling short of a full century. When it [PVC] was discovered does not matter since it wasn't a viable product. That is until WW2 when insulating wires for ships it proved itself useful. But those ships aren't really available for inspection (Big ba-da Boom). Or they have been refitted and ultimately now museums.
      We have learned NOT to use PVC for drinking water. Poison leaches out of it. Unlike a nuclear disaster, many poisons from plastic never diminish. So flushing your poo and poison into the sewer, which IS part of our water supply, means those poisons are, albeit less concentrated, in your future drink. Let's not even begin with the toxins emitted in manufacturing all the plastics or how plastic is disposed of.
      Yes, PVC is so much easier to install under every sink and loo, right out to the curb under ground. But if you had a choice shouldn't you be asking yourself, "Do I want to stand behind my wife breathing while she sprays aqua net on her hairdo or should I just go take my Centrum+iron?"
      Yes, iron kills. But only if your wife is strong, mad and has an iron skillet to swing at your head. If she isn't strong, keep that spinach away from her, it's high in - you guessed it - iron.
      We need to keep moving in search of alternatives to plastics. Sorry Saudi Arabia (and Texas).

    • @alanm2842
      @alanm2842 11 หลายเดือนก่อน

      @@davepetrakos475 i don't know where you got 70 years from. i herd it had a life expectancy of 500 years

  • @jeremyolson4280
    @jeremyolson4280 3 ปีที่แล้ว +6

    That took 10.5 minutes. I would have cut the female thread adapter from the inside with a diamond wheel. Everything would have pried out in 5 minutes. I don't recommend using hammers on cast iron.

    • @Robinson-Homestead
      @Robinson-Homestead  3 ปีที่แล้ว

      Thanks for the comment Jeremy.

    • @jeffreyjohn2037
      @jeffreyjohn2037 3 ปีที่แล้ว +1

      Use a 2" hole saw to remove the center of the plug. Then use a sawsall cut the remaining plug out. The iron female adapter will break easily with a hammer. Then the lead will peel off. Complete prep. in less than five minutes. Just did two today.

    • @stevenvanfleet2520
      @stevenvanfleet2520 3 ปีที่แล้ว +1

      @@jeffreyjohn2037 to you have video of that?

    • @jeffreyjohn2037
      @jeffreyjohn2037 3 ปีที่แล้ว +2

      @@stevenvanfleet2520 no, I don't do videos. But the 2" hole saw works great. When the hole saw is almost through tip your drill to cut one side. Then grab the square part of the plug and pry it open so you don't drop any debris down the sewer line. Take your time and it will work out good. # Best Method.

    • @MK-xl9tt
      @MK-xl9tt 3 ปีที่แล้ว

      Hammer and chisel pops those brass clean out caps out in a matter of seconds

  • @JLitt-us4vs
    @JLitt-us4vs 2 ปีที่แล้ว

    This is great but I have a 3inch hub Y that I am trying to remove the lead in but it’s up in the wall near the ceiling. I’m trying to attach a 2in shower drain to it with a donut. It’s in a confined space. Maybe can get in there with a drill. Any ideas??

    • @Robinson-Homestead
      @Robinson-Homestead  2 ปีที่แล้ว

      If you melt it make sure you have good ventilation

  • @5050kas
    @5050kas 2 ปีที่แล้ว

    what about sewer gas exploding. seems to me drill and then melt the remainder. looks slow two pry bars at the same time would help