Fault Finding a Scary Lighting Circuit - Electrician Life

แชร์
ฝัง
  • เผยแพร่เมื่อ 21 เม.ย. 2021
  • Fault finding a scary lighting circuit - Electrician Life.
    Join Cory as he continues untangling the mess of wires at the job where I fitted the AFDD consumer unit. The installation has originally been done in a very strange way by the previous property owner and it takes Cory a lot of head-scratching to figure out what was going on!
    👀 Watch the original AFDD Install Video Here: • Installing an AFDD Con...
    👀 Watch Cory Installing the Garage Consumer Unit Here: • Sorting out a complete...
    🔔 Join This Channel To Get Access To Perks 👇
    ➤ / @artisanelectrics
    🧰🛠️ Tool Of The Day 👇
    Cable Ferret WiFi Camera: amzn.to/3eAerZq
    Super Rod Cable Pulling Set: amzn.to/38zzqrH
    Super Rod Cable Tongue: amzn.to/38Amfa0
    ✅ Check Out All Our Favourite Tools Here 👇
    ➤ www.amazon.co.uk/shop/artisan...
    -----Electricians Business Course-----
    📩 Sign Up To My Electricians Business Course Here And Get The First 4 Lessons Free 👇
    ➤ course.electriciansbusinessco...
    🔔 Subscribe to TOOLS4SPARKS TH-cam Channel 👇
    I Also Have A Dedicated TH-cam Channel About Tools:
    ➤ / tools4sparks
    -----TESLA REFERRAL CODE-----
    🚀 You Can Use My Referral Link To Get 1,000 Free Supercharger Miles On A New Tesla 👇
    ➤ ts.la/andrew24855
    -----MY ENERGY PROVIDER-----
    🐙 Get £50 credit when you switch to Octopus Energy 👇
    ➤ share.octopus.energy/zappy-sh...
    🏷️ DISCOUNT BUSINESS SUPPLIES 👇
    ➤ www.amazon.co.uk/tryAB/?tag=a...
    -----TRADES INSURANCE DISCOUNT-----
    If you need to renew your public liability insurance or need tools in van insurance, I recommend Rhino Trade Insurance, I've just renewed my insurance with them.
    🏷️ Use My Discount Code “ART5” and you get a 5% Extra Discount On Their Already Excellent Prices.
    ➤ www.rhinotradeinsurance.com/quote
    📞 or call 01162437904.
    📱 Don't Forget to Follow Social Media, FOLLOW US on Your Favourite Social Networks 📱
    📸 Artisan Electrics Instagram Account 👇
    ➤ / artisanelectrics
    🐦 Artisan Electrics Twitter Account 👇
    ➤ / artelectrics
    📓 Artisan Electrics Facebook Account 👇
    ➤ / artisanelectrics
    ADVERTS THAT SUPPORT THE CHANNEL:
    Thanks for your support!
    This video is for entertainment purposes only please do not attempt to copy or recreate. Do so at your own risk.
    #sparkylife #electricianlife #artisanelectrics
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 160

  • @artisanelectrics
    @artisanelectrics  3 ปีที่แล้ว +3

    Watch the original AFDD Install Video Here: th-cam.com/video/KJfbhnUKKUE/w-d-xo.html
    Watch Cory Installing the Garage Consumer Unit Here: th-cam.com/video/TrEFVUqcLGU/w-d-xo.html

  • @marktubeie07
    @marktubeie07 3 ปีที่แล้ว +26

    _"It's not old school, it's no school!"_ Corey 2021

    • @marioghioneto1275
      @marioghioneto1275 3 ปีที่แล้ว

      Lol i laughed so hard when he said that hahahhaha

  • @adrianstavrakis9126
    @adrianstavrakis9126 3 ปีที่แล้ว +29

    Finally the tone generator gets the recognition it deserves 😂

    • @fraggit
      @fraggit 3 ปีที่แล้ว +1

      I was a telephone engineer and I'm watching this shouting at the screen "get an amp and oscillator, for the love of Faraday" 😉

  • @bradh2066
    @bradh2066 3 ปีที่แล้ว +27

    Can tell Cory is more of an industrial spark than a domestic lol good vid lad 👍🏼

    • @tommymack3210
      @tommymack3210 3 ปีที่แล้ว +6

      I like industrial better than domestic😄 but its not bad to learn domestic for a while as apprentice

  • @TeamSimpsonRacing
    @TeamSimpsonRacing 3 ปีที่แล้ว +6

    When I see stuff like this, I just go to my pre rehearsed speech "your house needs a rewire"

  • @Ted_E_Bear
    @Ted_E_Bear 3 ปีที่แล้ว +4

    Cory is going to be a great star in the Sparky world !

  • @mistymick4905
    @mistymick4905 3 ปีที่แล้ว +5

    Hi Corey, The wiring that you had to deal with was unbelievable. A real head scratcher with a lot of swear words muttered (quietly). Well done for keeping your cool. I loved the line “they were kind of ahead of their time”. 😃🇦🇺

  • @nmccw3245
    @nmccw3245 ปีที่แล้ว +1

    Food, music, electrical, … it’s all good.

  • @Tom.r1990
    @Tom.r1990 3 ปีที่แล้ว +11

    Love the Chanel lads. Never ever ever ever seen any self respecting tradesman use a utensil to eat cake.... you boys are so artisan!!!!

  • @eamonnohalloran2254
    @eamonnohalloran2254 3 ปีที่แล้ว +5

    Great video Cory,
    Firstly, excellent use of that aluminium ladder. as a tea stand to hold your tea and cake white standing.
    thankfully the proper fiberglass ladder appeared for the electrical work.
    You are patient and walked us through your thinking process in your trouble shooting. Your"no school rather than old school " line is spot on . As you said there is a time to say "rip it out and reinstall properly" I always think when you put your hands on anothers bad work in the clients eyes it becomes yours. Thankfully this time the had the right man for the job. Your video is also a good legal document in recording the history of what you encountered and fixed. Well done.
    You are covering all your T.V possibilities. Nature , History,Food. There is no end to your career path.
    I do love the bit of cake with a cuppa. Thanks for making me laugh and taking us out to this job today I was woundering how it turned out. Happy EARTH DAY.

  • @n3ilvincent870
    @n3ilvincent870 ปีที่แล้ว

    Just love watching artisan electrics keep them coming😊

  • @dashcamandy2242
    @dashcamandy2242 3 ปีที่แล้ว +1

    2:22 - Cory, I can imagine you wiring up a cooker and then immediately jumping into a cooking demo for the customer, teaching them a new recipe. 10/10 would watch that.
    What a cluster that job was!
    For a time, I lived with some friends in a house built during the 1950s (US). Every light was operated by a momentary pushbutton switch that operated relays in the basement. After fifty years or more of use, the relays had mostly failed. Lights that were already on stayed on, because if you turned them off, they might not come back on again - or blink off before returning to on. At least half of the house had lights that didn't work at all, or would give one extremely brief flicker when you push the button before staying off. Receptacles on these switches didn't work in most of the house. An absolute nightmare.
    I tried to convince them to do a rewire, since they were letting me stay there rent-free and I was unemployed and had the time to do it... It would have been pretty simple, everything was wired through conduits down to a single main trunking tray that ran in a beautiful straight line to the consumer unit and the box with all the relays in it. An electrician's dream to rewire! (The house was built by the same contractor that built several local schools, so it's over-engineered and built to a commercial level.)

  • @Tisapery
    @Tisapery 3 ปีที่แล้ว +42

    Bundy Vs Jordan
    Me Vs Corey
    Boxing match
    Winner gets a drum of 1.5 twin and earth

    • @Ned47628
      @Ned47628 3 ปีที่แล้ว +9

      Nigel Vs Nom Nom?

    • @tomorichard
      @tomorichard 3 ปีที่แล้ว +4

      Nagy vs Oscar....my money is on Oscar

    • @artisanelectrics
      @artisanelectrics  3 ปีที่แล้ว +5

      🤣🤣🤣

    • @davidfleck6551
      @davidfleck6551 3 ปีที่แล้ว

      Bang bang Bundy against jumping Jackflash Jordan 😂😂😂

    • @ianmiller3182
      @ianmiller3182 3 ปีที่แล้ว

      No punching above the neck !

  • @alfacoro1984ify
    @alfacoro1984ify 3 ปีที่แล้ว +4

    Great video and the exact way that I would fault find this with the power on so many videos with people saying we should not work live and all this rubbish we are electricians it is our job. As long as you use the proper test equipment and work safely and do not leave and live power exposed where other people can be this is the quickest and best way to do the job great video.

  • @welshgriffo
    @welshgriffo 3 ปีที่แล้ว

    That was stressful to watch, I chose industrial installations all day long, you deserve a medal for putting up with that type of mess

  • @DirkGorgiel
    @DirkGorgiel 3 ปีที่แล้ว +2

    Greetings from Germany! What a lovely Chap. He knows what to do, he's funny and cheeky in one, but profesional in the same Time. 👋 I understand him very well, what is an Advantage. Yes, I speak that far Germanic Dialect, too!

  • @stevejagger8602
    @stevejagger8602 3 ปีที่แล้ว +1

    Well done untangling this nightmare. I recommend buying yourself a Progressive Electronics 200EP inductive amplifier together with its audio warble tone generator for tracing out cables when you are on your own. As I have said in a previous comment this unit has saved me hours of unnecessary stress by quickly locating and identifying cables in an installation. On second fixes this unit helped me find cables lost behind plasterboard because cutouts in the plasterboard for socket outlets and light switches had been forgotten.

  • @jamiewiseman
    @jamiewiseman 3 ปีที่แล้ว +5

    The lighting wiring you've described sounds very much like the French system using teleinterrupteurs..... basically you have a switch unit attached to the breaker in the CU which receives a signal from the switches which then sends sends or turns off power to the lighting part of the circuit. The advantage is that you can have as many switches as you like and wherever you want them.

    • @davidbeakhust9797
      @davidbeakhust9797 2 ปีที่แล้ว +1

      I remember staying in a gite in France that had an immense CU, with a number of what seemed like contactors in. It seemed it followed the system you describe. A friend who moved to France and had to do up an old farmhouse using a local spark also said he thought his electrician was mad, but the guy assured him it was "the way it was done there". So maybe the spark who wired the property in the video was French. I don't see point in rewiring it, just to fit with UK traditions. Surely already 3-plate system can present problems with led lights, so new builds don't use it. Tradition is not always "right".

    • @thesteelrodent1796
      @thesteelrodent1796 10 หลายเดือนก่อน

      that's basically how PLC works. With PLC you only have power going through the controller relays to the lights and fans, and whatever else is connected to it, and then switches are connected to the controller through signal wires, which can be quite thin since they don't carry any real current. Since the PLC is programmed to turn on/off or dim stuff depending on which signal it gets (and what the current state is), you can hook up as many switches as you want using the signal wires and the only thing that determines what they do is how they're connected to the controller, and how that is programmed. It completely removes the need for switchback wiring when you want multiple switches controlling the same thing, and any switch can be programmed to be a dimmer if you want, or you can code patterns, where 1 press turns on the light, the next press turns on the fan, and so on.

  • @rscelectrical7091
    @rscelectrical7091 3 ปีที่แล้ว

    Great bit of detective work & fault finding, love your perseverance.

  • @JIBS.
    @JIBS. 3 ปีที่แล้ว +2

    Brilliant as Always from Artisan Electrics

  • @jontownsend8090
    @jontownsend8090 3 ปีที่แล้ว +1

    That job was like the crypton factor, get it wrong, and you're scratching your head forever. Good investigative work, powered by an slice of nice.

  • @terrystephens1102
    @terrystephens1102 2 ปีที่แล้ว

    A really strange piece of circuitry- I am impressed with how you solved the puzzle, Cory, great job.😃👌👌👏👏👏❤️

  • @aktelectricalaktelectrical4
    @aktelectricalaktelectrical4 3 ปีที่แล้ว +5

    Nicely sorted out Corey and very patient. How many hours did that take? It would take me twice as long and I have to draw diagrams.

  • @martindunford2291
    @martindunford2291 3 ปีที่แล้ว

    Great detective work...frightening what folks do and pass off as safe and efficient!

  • @Chris_In_Texas
    @Chris_In_Texas 3 ปีที่แล้ว +7

    I think that this would have been a good thing for the kinetic switches and just rewire it all. What a huge mess.

  • @simthespark324
    @simthespark324 3 ปีที่แล้ว +4

    I like these guys, top sparkies ⚡️

  • @tww5719
    @tww5719 3 ปีที่แล้ว +3

    Just shows you never take things for granted ie just because the single was black does not mean it's a neutral ,looks like a diy job,at least you got there in the end 👍

  • @FistralG
    @FistralG 3 ปีที่แล้ว +1

    That was interesting but confusing. I’m glad Cory sussed out what was going on as I got completely lost. 🙂

  • @apluselectricalsolutions684
    @apluselectricalsolutions684 2 ปีที่แล้ว

    This reminds me of a job I done on a friends house, where there were lights on permanent feeds and switches switching different lights on 🤯, just got to trace each cable to figure it all out, fun times!

  • @alanwalton5735
    @alanwalton5735 7 หลายเดือนก่อน

    Some poelpe say loop in,loop out is complicated. But least you have a starting point.

  • @AdamSpooner191
    @AdamSpooner191 2 ปีที่แล้ว

    That looks like it was an absolute nightmare! Well done for sorting it all

  • @gmeadowcroft84
    @gmeadowcroft84 3 ปีที่แล้ว +2

    Recently had something similar myself, I just spoke. To the customer and said look I can spend hours working this out, we have really goo access I think because it so confusing we rewire the lights

  • @stevejagger8602
    @stevejagger8602 3 ปีที่แล้ว

    PS I had a mess to sort out in a kitchen with exposed floor joists as a ceiling, including lighting cables with no cpc. Ripping it all out and starting afresh was very satisfying and made for a safer installation.

  • @g.williamswilliams8442
    @g.williamswilliams8442 2 ปีที่แล้ว

    A very intelligent sparky for his years . Well sussed.

  • @affy675
    @affy675 3 ปีที่แล้ว

    Thought you were about to find something i have in the past with the dead switches.
    I came across a DB that had the phase and neutral connected cross polarity at the main switch. This meant all the switches were switching neutrals and every neutral was live! So dangerous

  • @alanjones3873
    @alanjones3873 3 ปีที่แล้ว +3

    Always wondered why sparks dont use tone generators. Used them nearly 60 years ago as phone engineer . Old Skool can be best!

  • @johnspallen3132
    @johnspallen3132 2 ปีที่แล้ว

    Brilliant sparks

  • @SPV1579
    @SPV1579 3 ปีที่แล้ว +1

    Well done for sorting that lot out, never seen anything like it. If I’d have gone to that job I would have seriously considered going into the cake making instead😂😂. Great vlog👍👍

  • @tahseenashfaq
    @tahseenashfaq 3 ปีที่แล้ว

    another great video from Cory

  • @alanstanley9465
    @alanstanley9465 3 ปีที่แล้ว

    Well worked out

  • @sworrall
    @sworrall 3 ปีที่แล้ว +2

    Looks like star wiring you used to do for running X10 din rail dimmers that all terminate in a node0 (or consumer unit in this case). has the previous owner just taken all their home automation units out?

    • @benespection
      @benespection 2 ปีที่แล้ว +1

      I was wondering the same thing - it smells a lot like a former home automation job

  • @andyhill242
    @andyhill242 3 ปีที่แล้ว +8

    I think whoever originally installed that was having a breakdown at the time!

    • @daveblack5109
      @daveblack5109 3 ปีที่แล้ว

      yeah, or half a night school course...

  • @MatthewGeier
    @MatthewGeier 3 ปีที่แล้ว

    An acquaintance wired his house like that - all switch wires back to the board - but there was method in this madness, he was an electrical engineer (with a trade ticket) and he built its own 'smart home' system. Every one of those switches was input to a computer which then controlled contactors to actually turn the lights on and off. He 'star wired' all the power points too, so they could be centrally controlled and monitored - he also added current sensing to each line and recorded power consumption for each circuit. It was a LOT of work and wire. But he could turn on or off any light or socket in his house from anywhere that had internet access. When he built it, these modern interconnected smart home systems only just appearing on the market and were quite expensive. If a regular sparkie ever gets called to that property 'diety' help them. They will be flummoxed. It complies with the required standards, but it's not a conventional layout.

  • @bri200490
    @bri200490 2 ปีที่แล้ว

    Another great video . Yup I’m a low voltage tech and a tone generator is an essential bit of kit for me

  • @Slademoses
    @Slademoses 3 ปีที่แล้ว

    the shelf looks gr8

  • @Rosscoff2000
    @Rosscoff2000 3 ปีที่แล้ว

    At the end of the day, that's a much better way to have the lights wired, especially as you said for smart switching in the future.
    The main reason we do lighting wiring as we usually do with a loop down to the switch, is simply to save money on cabling. Wiring back to a central point is way more flexible, just a little bit more costly.
    I would have just put a wiring centre box for the lighting near the board for wiring up all the lighting, so as not to lose the benefits for the future.
    My 1969s house is wired a bit like that with one central junction box in the loft for all upstairs lights and another under the airing cupboard floor for the ground floor lights. That arrangement has been a real boon for later modifications and additions.

  • @yorkshireoz3583
    @yorkshireoz3583 3 ปีที่แล้ว

    Awesome Cory
    I would have suggested a lighting rewire!

  • @AndyK.1
    @AndyK.1 3 ปีที่แล้ว +10

    It’s almost like no one looked at the old connections before they ripped the CU off

    • @tww5719
      @tww5719 3 ปีที่แล้ว

      You got it one ,must of been clear when stripping out 👍

    • @shaynemacdonald3051
      @shaynemacdonald3051 3 ปีที่แล้ว

      Exactly

  • @kriskay2771
    @kriskay2771 3 ปีที่แล้ว +7

    F*ckin hell Cory what a mess. Fair play mate. Well worked out. I'd of just said it all needs a rewire sorry.

  • @n3ilvincent870
    @n3ilvincent870 ปีที่แล้ว

    well done cory really enjoyed this video

  • @Ragnar8504
    @Ragnar8504 3 ปีที่แล้ว +1

    What a mess! Must have been a relative of the expert who wired permanent live and switch line to L1 and L2 on a 2-way switch, only to discover the light didn't work. Instead of moving the live to COM they ran a jumper wire from L1 to COM!
    The light might be an ancient (early 60s) German fitting. Pre-1965 German colours were black live, grey or white neutral and red earth. The same scheme was used in a few countries, including Sweden and Finland. Romania (since that was named in the comments) oddly enough seems to have used a mix of US (black live, white neutral) and UK (red, yellow, blue, black, green) colours.

  • @philipsmith0752
    @philipsmith0752 3 ปีที่แล้ว

    good work Cory , think Cory needs a new Oscar to help him ?

  • @jensschroder8214
    @jensschroder8214 3 ปีที่แล้ว

    - Cable to a distribution box, from there a cable to the switch and a cable to the lamp.
    - Cable to the lamp and from there a cable to the switch.
    - Cable to the switch and from there to the lamp.
    - But from the fuse box all cables to the lamp and from the fuse box all cables to the switches, this technology is new to me. There must be cable lengths.
    As a consequence, you should place a radial for each individual socket to each individual fuse!

  • @oyleyhands1332
    @oyleyhands1332 3 ปีที่แล้ว +1

    I seem to remember mentioning a tone tester in a previous comment 😉

  • @lonewolfgeoff
    @lonewolfgeoff 3 ปีที่แล้ว

    nicely done cory! imagine if they now ask for the house rewired!!! 😱😂
    well any more work there it'll be cory on his own!!!

  • @martin54123
    @martin54123 3 ปีที่แล้ว

    Aced it Cory - What a mess, well figured out though, I think you'd be a great food channel host too!

  • @busman2000
    @busman2000 3 ปีที่แล้ว

    Does the power from the consumer unit in a lighting circuit go to the switch or to the lamp first..? Here it goes to the switch and cable is terminated then carried on to the light from the other side of the switch and Earth /CPC are used if required.class 1 permitting etc.

  • @daytonamann5618
    @daytonamann5618 3 ปีที่แล้ว

    Thanks for the Vid !! Just a thought: could you chuck the shower cable into a rotary lockable isolator? Would tidy things up a bit!!

  • @AndyK.1
    @AndyK.1 3 ปีที่แล้ว

    You just went back of the food 😂

  • @normanboyes4983
    @normanboyes4983 3 ปีที่แล้ว

    It took a lot of effort and head scratching to install the lighting circuits like that - ‘and now you gone and spoiled it all.’😂

  • @Wrexham_fc
    @Wrexham_fc 2 ปีที่แล้ว

    These videos are very good and I'm learning quite a bit from watching you guys 100% recommend

  • @showme360
    @showme360 2 ปีที่แล้ว

    Your only mistake Cory is trying to fix the problem in the first place, your an absolute legend mate doing the fault finding, but I would of recommend a new rewire for the customer as a professional install, better value for money at the end of the day!! I mean would you want to put your name against that as a sign off?

  • @petertallowin6406
    @petertallowin6406 3 ปีที่แล้ว +1

    Good work Cory 9/10 would have cried re-wire and the 1 that didn't was Cory.

  • @BarcroftLaboratories
    @BarcroftLaboratories 3 ปีที่แล้ว

    I'm guessing that at some point the house was originally wired with a lights master on switch or lights master off switch (or even both) that might explain the mess

  • @sirronnitram8937
    @sirronnitram8937 3 ปีที่แล้ว +4

    Amazing perseverance. Nagy would have ripped it all out and started from scratch

    • @sirronnitram8937
      @sirronnitram8937 3 ปีที่แล้ว +13

      Delroy would have tinkered with his Megger for a few hours and then the penny would have finally dropped, with few chuckles on the way. Dave Savoury would do a one hour presentation with circuit diagrams and highlight all the regulation breaches.

    • @sampergusey5301
      @sampergusey5301 3 ปีที่แล้ว +2

      @@sirronnitram8937 😂😂😂

    • @barrybritcher
      @barrybritcher 3 ปีที่แล้ว

      We would have waited a month for the video you mean

  • @stevengrace6712
    @stevengrace6712 3 ปีที่แล้ว

    Very Fancy tea and cake get up!! Is that Kewtech tester? Have you done a review?

  • @gd2329j
    @gd2329j 3 ปีที่แล้ว

    Yes switch off the living room lights & all the up stairs lights go out !
    10 green cables wires all singles in the back of the living room switch box .
    Not a one is ground .
    That is old school & so is the up stairs 5 amp ring in tinned steel cable ( in v i. r .cable )

  • @n3ilvincent870
    @n3ilvincent870 ปีที่แล้ว

    are you sure its not wired to the ring main

  • @Liberator975
    @Liberator975 3 ปีที่แล้ว

    Im ready for some artisan snacks section

  • @acelectricalsecurity
    @acelectricalsecurity 3 ปีที่แล้ว

    That's been done by someone who didn't really know what they were doing, they would have used so much cable, i have seen it done where there was a big joint box, and there's only one cable at the light and one cable at the switch, but never like that though.

  • @audriuskomicius1838
    @audriuskomicius1838 3 ปีที่แล้ว

    Smart house project did not gone as planned? At least looks like that on the light wiring.

  • @nedperry8527
    @nedperry8527 3 ปีที่แล้ว

    I think notching and drilling joists should be between 25 & 40% of the span of the joist

  • @rogerbeck3018
    @rogerbeck3018 3 ปีที่แล้ว

    smells like DIY from here

  • @RichardArblaster
    @RichardArblaster 3 ปีที่แล้ว

    What a nightmare 😮😮😮

  • @alanhodgson8443
    @alanhodgson8443 3 ปีที่แล้ว +1

    Clearly bodgit and scarper spent a lot of time in that house. Admire your patience to sort that mess.

  • @mudmucks
    @mudmucks 3 ปีที่แล้ว +1

    How many times did Cory say "I think I've sussed it out now" :) :)

  • @djb774
    @djb774 3 ปีที่แล้ว

    Cory? You never heard of 4 plate? 😂

  • @user-ws8ev7nz3e
    @user-ws8ev7nz3e 3 ปีที่แล้ว

    I love how in Soviet Russia we have some fire safety requirements which you, EU guys, doesn't have at all. For example in Russia you can't have any kind of live wire(even non-flammable kinds) on flammable surfaces and around flammable surfaces(like wood) without metal tubing of some sort.

  • @nocode1603
    @nocode1603 3 ปีที่แล้ว +1

    Aye chuck your day job the eating cake bit was enuff to put u right off....

  • @denverread2221
    @denverread2221 3 ปีที่แล้ว

    Right what’s the process of becoming a sparky 🤪

  • @andrewpowell6457
    @andrewpowell6457 3 ปีที่แล้ว

    @Artisan Electrics Jordon get Cory a tone generator or a helper

  • @stevecraft00
    @stevecraft00 3 ปีที่แล้ว +1

    Nobody would blame you for working live in that situation. Empty house, only you and camera man there.
    Usual way of wiring lighting in singles is to loop the permanent live through each switch. It's dead easy. They seem to have made a massive hash of it.

    • @user-wk7wv8rn8h
      @user-wk7wv8rn8h 3 ปีที่แล้ว +1

      I do it all the time when I lose the switch live when changing pendants 🤣 ends of cables dangling out the ceiling, but I know not to touch them and keep the cables separated

    • @stevecraft00
      @stevecraft00 3 ปีที่แล้ว

      @@leewinters606 eh? I never said it was unsafe. Quite the opposite. He's by himself, not causing danger to others.

  • @hoxton6394
    @hoxton6394 2 ปีที่แล้ว

    fun fact: in germany the old color code was Black as Live, Gray as Neutral and red as Earth

  • @ianmiller3182
    @ianmiller3182 3 ปีที่แล้ว +1

    Top presentation. Perhaps the installation was undertaken by someone who was only familiar with the use of singles.

    • @johnbrewer9833
      @johnbrewer9833 2 ปีที่แล้ว

      I wonder if the same sparkie would have coped with an intermediate switch in a long passage way.....

  • @dsmale7067
    @dsmale7067 3 ปีที่แล้ว

    Yep a Tone generator will save a lot of time and frustration

  • @smolson00
    @smolson00 3 ปีที่แล้ว

    You should of used a cable toner instead of putting voltage on it first.

  • @shaynemacdonald3051
    @shaynemacdonald3051 3 ปีที่แล้ว

    Haha Cory you should of took more time to suss out what was going on before taking out the old Fuseboard.

  • @buixote
    @buixote 3 ปีที่แล้ว

    If you take a piece of small gauge "music wire" (tempered steel), and bend it in a v-shape, sew/tape it into the nose bridge on your mask, you won't have to keep pulling the mask up.

  • @elliottslab
    @elliottslab 3 ปีที่แล้ว

    Sometimes it’s just easier to just start again 😂

  • @newlinerealboi3434
    @newlinerealboi3434 3 ปีที่แล้ว

    Better late than never 🤣

  • @busman2000
    @busman2000 3 ปีที่แล้ว +2

    Yes a tone generator makes a lot of sense when you are lost and it's a lot safer than making things hot.

  • @garymcleanuk
    @garymcleanuk 3 ปีที่แล้ว

    I’m no sparky but OMG

  • @AndyK.1
    @AndyK.1 3 ปีที่แล้ว +9

    We all knew the cable he removed was going to bite him at the end.

    • @stevecraft00
      @stevecraft00 3 ปีที่แล้ว +5

      We did an eicr yesterday. Appeared to be a redundant immersion heater feed in the board. My mate said yeah we'll snip that off. I told him to hang fire because the spur for the fire suite was in a weird place half way up the wall right below where the cylinder cupboard was. 😉 But that appeared to be on the lighting circuit (6A...yeah). We energised the old immersion feed and lights came on. Wtf? Somebody had mixed up lights and the immersion feed. Leaving a lighting circuit on a 16A and the fire (clearly never used) an a 6A. All 1.5mm so guess an easy mistake to make but good job my mate didn't cut off that redundant feed as it fed a lighting circuit!

  • @electronash
    @electronash 3 ปีที่แล้ว

    Red wire = Earth. :o
    Yeah, that makes sense. lol

  • @lkm5462
    @lkm5462 3 ปีที่แล้ว

    Can’t believe you don’t have a tone generator

  • @andrewpowell6457
    @andrewpowell6457 3 ปีที่แล้ว

    That is one weird wiring setup

  • @amritdaffu5839
    @amritdaffu5839 3 ปีที่แล้ว

    EAT THE CAKKEEEE

  • @vincentwilkes9611
    @vincentwilkes9611 3 ปีที่แล้ว

    Pretty much the way my last 4 houses have been...Breakers for wall sockets and lighting circuits....Thou shalt not mix....

  • @gizmothefuzzball9825
    @gizmothefuzzball9825 3 ปีที่แล้ว +1

    Give that man a pay rise, this hurt my head watching it

  • @geraldelwood9660
    @geraldelwood9660 3 ปีที่แล้ว

    Not sure if you have the same problem as I had the other day. I found an old colour 3 core at both switches plus a single black at one of them. I wondered where was the other conductor for the switch wire. However it transpired they must have taken the 3 core to the ceiling rose. Cut into it and used the red conductor as a feed to switch 1 and used red from switch 2 as a switch wire to the C/rose. But they had miswired and connected the yellow to the common terminal. This caused the symptom of light switching you described. The single black conductor was used to feed the next light on the circuit. In addition one of the switches was not working and the blue conductor had a break. Bit of a challenge for me :)