Add a Powerflex 525 drive to a Controllogix Compactlogix over Ethernet

แชร์
ฝัง
  • เผยแพร่เมื่อ 25 ก.ค. 2024
  • In this lesson we show you how to add an Ethernet device to your Controllogix or Compactlogix PLC. While we adding a Powerflex 525 drive to a Compactlogix PLC in this video, the principles are the same for adding any Ethernet device to a Controllogix or Compactlogix PLC in Studio 5000.
    Get the full details of this lesson at: twcontrols.com/controllogix-c...
    Items used in this video:
    PLC Trainer twcontrols.com/plc-trainers
    Support these videos while you advance your skills courses.twcontrols.com/
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 162

  • @jerrycarter3963
    @jerrycarter3963 2 ปีที่แล้ว +5

    Thank you for your videos. I have done quite a bit of programming (allen bradley, automation direct, and others) but i always like witching and learning new things. You do a great job of explaining. Thank you for your time and dedication.

    • @TimWilborne
      @TimWilborne  2 ปีที่แล้ว +1

      You are welcome Jerry!

  • @victortarango101
    @victortarango101 ปีที่แล้ว +1

    Tim excelent video I highly appreciate yours support for showing it😀

  • @palazzolo85
    @palazzolo85 2 ปีที่แล้ว +1

    Subscribed. Your a good man, I’m a fellow controls engineer. Work with AB on a daily basis.

    • @TimWilborne
      @TimWilborne  2 ปีที่แล้ว +1

      Thanks for subscribing!

  • @patrickhopman4350
    @patrickhopman4350 2 ปีที่แล้ว +1

    Have made a sequel video to this? I would like to see an example of programming speed control setting up some of the other parameters. Also, can it be configured to use either ethernet or the push button/potentiometer? Love your videos by the way, they are the best ones I've found at explaining things.

    • @TimWilborne
      @TimWilborne  2 ปีที่แล้ว +1

      Hi Patrick, check out this series, it has several different setups for the Powerflex 525.
      twcontrols.com/ac-drives-and-3-phase-motors

  • @anthonybuddini2828
    @anthonybuddini2828 8 หลายเดือนก่อน +1

    Hi Tim, thank you for the information. Very useful video...

    • @TimWilborne
      @TimWilborne  8 หลายเดือนก่อน +1

      You are welcome

  • @2012jordanat
    @2012jordanat 2 ปีที่แล้ว

    These videos are absolutely phenomenal! It's tutorials and explanations like these that have helped me teach myself these automation systems, so thank you so much for your time and effort here!
    I don't suppose you have plans to pull together a video similar to this one, expect using a Micro800 series with the PF525? I'm looking to control one using an 850, a PanelView, and a PF525...

    • @2012jordanat
      @2012jordanat 2 ปีที่แล้ว +2

      And as soon as I finished this comment, I saw your "Program a Micro820 to Control a Powerflex 525 with a UDFB" video in my upcoming videos list...so thank you!

    • @TimWilborne
      @TimWilborne  2 ปีที่แล้ว +2

      You are welcome!

  • @bandapgbr1
    @bandapgbr1 3 ปีที่แล้ว +1

    Tim, Thank you so much for share !!!!
    Im from Brazil

  • @shawnspencer8766
    @shawnspencer8766 3 ปีที่แล้ว +1

    Awesome video
    Id be interested in seeing different speed set points and using the logic to change them (ie one button slow jog, second button fast jog)

    • @TimWilborne
      @TimWilborne  3 ปีที่แล้ว +2

      I just recorded that for one of our Patreon supporters. It should be public soon.

    • @joebilby1007
      @joebilby1007 2 ปีที่แล้ว +1

      @@TimWilborne Hey Tim, is the video still only for your Patreon supporters?

    • @TimWilborne
      @TimWilborne  2 ปีที่แล้ว

      @@joebilby1007 Here you go th-cam.com/video/lPfHHnsCos0/w-d-xo.html

  • @nuragasaric9596
    @nuragasaric9596 2 ปีที่แล้ว +1

    I did same thing and I/O didn't come on at all it whould be nice to get video about it .Thank you

  • @guangyaoli6218
    @guangyaoli6218 7 หลายเดือนก่อน +1

    Thank you very much for your answer boss! One more question is if I use wifi in a plant. How to set ip address to match plc inrslink?Could you make a viedo show?

    • @TimWilborne
      @TimWilborne  7 หลายเดือนก่อน +1

      Same way as wired

  • @rahulrpatil3005
    @rahulrpatil3005 3 ปีที่แล้ว +1

    Brilliantly done 🙏👍🏼

  • @fernandodepaulavicente9027
    @fernandodepaulavicente9027 3 ปีที่แล้ว +2

    PARABENS PROFESSOR SOU BRASILEIRO VENDO TODOS SEUS VIDEOS E DANDO LIKES.

  • @lalitpandey8023
    @lalitpandey8023 3 ปีที่แล้ว +1

    Thanks sir for this video, please share video on the use of sequence control in plant automation.

    • @TimWilborne
      @TimWilborne  3 ปีที่แล้ว +1

      Hi Lalit. We have that for RsLogix 500. You can find it at the following link. We have machine sequencing lessons in the works for Studio 5000 and Connected Components Workbench planned, with the notable missing method of sequencer instructions. I don't believe they are a good way of sequencing machine steps.
      twcontrols.com/allen-bradley-rslogix-500-lessons-for-the-micrologix-and-slc-plc

    • @lalitpandey8023
      @lalitpandey8023 3 ปีที่แล้ว +1

      @@TimWilborne Thanks alot for your support .

    • @TimWilborne
      @TimWilborne  3 ปีที่แล้ว

      @@lalitpandey8023 You are welcome.

  • @muhammadshehbaz7765
    @muhammadshehbaz7765 6 หลายเดือนก่อน +1

    its very interesting and informative video. thank you for making it

    • @TimWilborne
      @TimWilborne  6 หลายเดือนก่อน +1

      You are welcome

  • @nandusuresh2202
    @nandusuresh2202 7 หลายเดือนก่อน +1

    Thankyou soo much for the videos ❤❤

    • @TimWilborne
      @TimWilborne  7 หลายเดือนก่อน +1

      You are so welcome!

  • @ManojYadav-rq8or
    @ManojYadav-rq8or ปีที่แล้ว +1

    Hi tim can you help me how to do configuration of two device ome master plc and other ethernet module via wireless anybus bolt wifi

  • @rxplusplates646
    @rxplusplates646 23 วันที่ผ่านมา +1

    Great videos as always! If i am using a momentary foot pedal to control the powerflex can I use the start command in the "Jog" output instead of the start?

    • @TimWilborne
      @TimWilborne  22 วันที่ผ่านมา +1

      Honestly I have never used the Jog feature, I should play with it sometime. The easiest way to do it is XIO Drive.Start OTE Drive.Stop. That way when ever the Start has a 0 in it, it will put a 1 in the Stop, and vice versa.

  • @geesonmartinem.r4926
    @geesonmartinem.r4926 2 หลายเดือนก่อน

    Very detailed information.thank you Sir

    • @TimWilborne
      @TimWilborne  2 หลายเดือนก่อน

      Thank you

  • @mikebradley812
    @mikebradley812 2 ปีที่แล้ว +1

    Thanks for the videos, your doing a great job. When we have to replace a drive that is networked to a Compact Logix via ethernet, we often have problems getting the drive to work with the system. Is there a video that you have that covers troubleshooting these problems? Thanks again

    • @TimWilborne
      @TimWilborne  2 ปีที่แล้ว +1

      Do you have trouble setting the IP address or the other parameters?

    • @mcleodautomation
      @mcleodautomation 2 ปีที่แล้ว

      You're

  • @richardsonmoura593
    @richardsonmoura593 6 หลายเดือนก่อน +1

    Hi, thanks for all of your videos, really useful for me. Please could you tell me, how the plc keep the parameters for those inverters, I meanimg, we have a powerflex 225 burned out and we just set the IP on his HMI and all parameters was set and it works as built. How it happened? Thanks.

    • @TimWilborne
      @TimWilborne  6 หลายเดือนก่อน +2

      Automatic Device Configuration, check out this video.
      th-cam.com/video/TZhuCUGcp3s/w-d-xo.html

  • @user-ti7br7zv2r
    @user-ti7br7zv2r 5 หลายเดือนก่อน +1

    good explaination thank you sir .

    • @TimWilborne
      @TimWilborne  5 หลายเดือนก่อน +1

      You are welcome

  • @souravsain4178
    @souravsain4178 ปีที่แล้ว +1

    How to change IP address in Power flex video-18?

  • @tarekmohsen7572
    @tarekmohsen7572 11 หลายเดือนก่อน +1

    Thank you very much

    • @TimWilborne
      @TimWilborne  11 หลายเดือนก่อน +1

      You are welcome

  • @funnyshortsdaily515
    @funnyshortsdaily515 2 หลายเดือนก่อน +1

    If my drive fails and I replace it do you have a vid on how to load the old parameters to it along with set up Ethernet connection?

    • @TimWilborne
      @TimWilborne  2 หลายเดือนก่อน +1

      Here is a video of backing up your Powerflex drive.
      th-cam.com/video/81G0YY5XCS4/w-d-xo.html

  • @balakumaranrajavelu3218
    @balakumaranrajavelu3218 ปีที่แล้ว +1

    Hi Tim, Thank you for knowledge you share. I have to replace on same 525vfd but different version ( old is version 1.6 and new one is version 4.0). After copying vfd program and connected to plc but Ethernet not connecting. But same vfd working with same Ethernet IP if i control from my PC

    • @TimWilborne
      @TimWilborne  ปีที่แล้ว +1

      Chances are you have an electronic key and mismatch. The firmwares must match.

  • @phucrau007
    @phucrau007 2 หลายเดือนก่อน +1

    Thank you Sir🤝🤝🤝🤝

    • @TimWilborne
      @TimWilborne  2 หลายเดือนก่อน +1

      You are welcome

  • @dadoscopernicus9406
    @dadoscopernicus9406 ปีที่แล้ว +1

    Hi Tim, how can i record the Energy consumption of powerflex 525 to Studio 5000?

    • @TimWilborne
      @TimWilborne  ปีที่แล้ว +1

      Check out the scatter read message in the user manual, it is on the list to a do a video on.

  • @tgomidwest9399
    @tgomidwest9399 3 ปีที่แล้ว +1

    I think PLC to PLC communication would be a great topic to cover.

    • @TimWilborne
      @TimWilborne  3 ปีที่แล้ว +3

      We've hit Controllogix to Micro800 and Micro800 to Controllogix communications and we have Controllogix to Controllogix communications coming. Anything else come to mind?

    • @shawnspencer8766
      @shawnspencer8766 3 ปีที่แล้ว +1

      @@TimWilborne I see a lot of controllogix to SLC 500 communications at my job. That would be a cool topic to cover as well

    • @TimWilborne
      @TimWilborne  3 ปีที่แล้ว +3

      @@shawnspencer8766 I could cover that. I'll put it on the list Shawn.

  • @joseangelrinconluengo5331
    @joseangelrinconluengo5331 ปีที่แล้ว +1

    how do i know which revision i have to put when im adding the drive? Thanks

    • @TimWilborne
      @TimWilborne  ปีที่แล้ว +1

      Go Communications, Who Active, right click the drive and select Device Properties.

  • @pratik9057
    @pratik9057 3 ปีที่แล้ว +1

    Thank you so much for the video, I have to make some changes to my data type the default data type doesn't have the actual current. what should I do to get actual current in the Input which are read from the VFD

    • @pratik9057
      @pratik9057 3 ปีที่แล้ว +1

      Ok i found it, its in the drive properties/Device Definition/Connection format. thank you very much

    • @TimWilborne
      @TimWilborne  3 ปีที่แล้ว +1

      Glad you found it.

  • @alangutierrez1447
    @alangutierrez1447 ปีที่แล้ว +1

    Can you do a video explaining a power flex 525 path splicing failed splice path

    • @TimWilborne
      @TimWilborne  ปีที่แล้ว +1

      Do you have a yellow triangle beside of it?

  • @pablodigamon9360
    @pablodigamon9360 2 ปีที่แล้ว +1

    Thanks Tim. good Video Do you have video tutorial to how to set up IP number of 1794 AENT and 1747 AENTR

    • @TimWilborne
      @TimWilborne  2 ปีที่แล้ว +2

      Here is how I do it.
      plctools.com/how-to-read-and-write-an-ip-address-to-an-allen-bradley-1794-aent-flex-i-o-module/

    • @marcelodigamon4845
      @marcelodigamon4845 2 ปีที่แล้ว

      @@TimWilborne Thank you

  • @automotivate.vamshi1549
    @automotivate.vamshi1549 2 ปีที่แล้ว +1

    Nice video.

  • @kinikinrd
    @kinikinrd 3 ปีที่แล้ว +2

    Tim, I love you videos but this one brings up a question.
    The two ways you show to turn on and turn off the drive produce the same result but the first one is instantly recognizable as on-off and the second must be interpreted you might say. To the average person the first is easier to understand. Green button turns it on, red button turns it off. The second example has a latch which is not needed, otherwise they are the same. Both take two rungs. What is the benefit of using the harder to read method?

    • @TimWilborne
      @TimWilborne  3 ปีที่แล้ว

      The second one is what you will more commonly see and allows for much more control flexibility when you go beyond a basic start stop.

  • @philliptwin326
    @philliptwin326 3 ปีที่แล้ว +1

    I'd like to know if you could show us how to integrate a vision camera on a Controllogix or Micrologix over ethernet, please

    • @TimWilborne
      @TimWilborne  3 ปีที่แล้ว +1

      Hi Philip. I don't have the hardware for that.

  • @brianm17
    @brianm17 3 ปีที่แล้ว +1

    At 8:43 I noticed that you have three options for the start source (#46, 48, and 50). Number 50 is already set to E/IP. Did you have to change source one to E/IP or is there a way to simply select source three as your control method?

    • @TimWilborne
      @TimWilborne  3 ปีที่แล้ว +2

      Hi Brian, you can configure digital inputs to switch between start sources and speed references. I have done this once, it would make for a good exercise. It had a 3 position Hand Off Auto selector switch. When in Auto, it's start source and speed reference was over Ethernet, but when in hand, its start source and Ethernet were from the drive I/O terminals.

  • @juanenriquerivera7808
    @juanenriquerivera7808 หลายเดือนก่อน +1

    How can I get one of the trainer boards that you use in your videos and what's the price?

    • @TimWilborne
      @TimWilborne  หลายเดือนก่อน +1

      Here you go
      twcontrols.com/plc-trainers

  • @nelsonpantaleon7751
    @nelsonpantaleon7751 ปีที่แล้ว +1

    How about siemens like s7 1200 controlling thevspeed of vfd same like this video i hope you have video for s7 1200 siemens

    • @TimWilborne
      @TimWilborne  ปีที่แล้ว +1

      No Siemens videos as of yet but we're exploring ideas.

  • @guangyaoli6218
    @guangyaoli6218 5 หลายเดือนก่อน +1

    boss .please show us asi gateway control in studio5000.tahnks a lot

    • @TimWilborne
      @TimWilborne  5 หลายเดือนก่อน +2

      Don't have one of those

  • @user-jl6ge8si2l
    @user-jl6ge8si2l ปีที่แล้ว +1

    Could you make a video on how to use the powerflex 525 VFD PID loop control function in studio 5000 using the compactlogix plc?

    • @TimWilborne
      @TimWilborne  ปีที่แล้ว +1

      That would make a good one.

    • @user-jl6ge8si2l
      @user-jl6ge8si2l ปีที่แล้ว

      ​@@TimWilborne Could you make a video on how to control the powerflex VFD in studio 5000 using modbus?

    • @TimWilborne
      @TimWilborne  ปีที่แล้ว

      @@user-jl6ge8si2l You can only do Modbus to the Powerflex 525 over serial, not Ethernet. Here is a video connecting a Micro820 to it over serial.
      th-cam.com/video/ARg2QHn3IB0/w-d-xo.html

    • @user-jl6ge8si2l
      @user-jl6ge8si2l ปีที่แล้ว +1

      @@TimWilborne Do you have a 1769-sm2 Compact I/O module or a Prosoft technology MVI69E-MBS module you can use with your compactlogix plc to control a powerflex vfd besides the powerflex 525? I would like see a video on how to setup and use those modules in studio 5000 on the compactlogix plc to control a powerflex 4 vfd so that I can learn how to do it myself. I watched the video on the Micro800 Modbus RTU Serial Configuration and gave me some good information, but I would like to see a video on how to setup and use the 1769-sm2 Compact I/O module or a Prosoft technology MVI69E-MBS module in studio 5000 on the compactlogix plc to control a powerflex vfd .

    • @TimWilborne
      @TimWilborne  ปีที่แล้ว

      @@user-jl6ge8si2l No, don't have either of them

  • @eliekhananya1551
    @eliekhananya1551 3 ปีที่แล้ว +1

    Do you know generally how old the revision on the vfd can be until it stops communicating? Bc I think we had a power flex 525 with a revision 3 that went bad, replaced it with a 6 and didn’t communicate bc in the plc it was a 3.

    • @TimWilborne
      @TimWilborne  3 ปีที่แล้ว +1

      You must change your major revision in Studio 5000. I should have thought to cover this. I'll put it on the list Elie.

  • @oanthientam9189
    @oanthientam9189 8 หลายเดือนก่อน +1

    thansk you , please help me , i can't find 525 inveter and adding into app rslogix5000, how to find that. best regarsd

    • @TimWilborne
      @TimWilborne  8 หลายเดือนก่อน +1

      Make sure you're right clicking Ethernet then selecting new module. Otherwise it won't show up, then enter Powerflex 525 into the filter box

  • @douglaslinton8292
    @douglaslinton8292 2 ปีที่แล้ว +1

    HI Tim Your videos are great my question to you how do you connect and disconnect the 525 from within the studio 5000

    • @TimWilborne
      @TimWilborne  2 ปีที่แล้ว +1

      Hi Douglas. Do you mean the inhibit function?

    • @douglaslinton8292
      @douglaslinton8292 2 ปีที่แล้ว +1

      no i was just setting up for the first time and saw a means to connect to the via project or physical i chose physical so was just wondering how to disconnect since i was able to connect

    • @TimWilborne
      @TimWilborne  2 ปีที่แล้ว

      @@douglaslinton8292 Still not sure I'm following your lingo. Do you mean viewing the module properties of the Powerflex drive and Studio 5000? If so the connect is more of make sure the parameters match what's in the offline and you'll get used physical, which is what's in the drive, or use project, which is what's in Studio 5000 after that. Not looking at Studio 5000 right now but I don't believe there's actually a disconnect or a need to disconnect afterwards. Just close the module properties.

    • @douglaslinton8292
      @douglaslinton8292 2 ปีที่แล้ว +1

      for example just like how you can go offline and online with the plc i was wondering if that was possible to do that to the vfd from within the studio 5000 software after you would have establish connection to the drive from the software

    • @TimWilborne
      @TimWilborne  2 ปีที่แล้ว

      @@douglaslinton8292 No. It's more like my previous reply.

  • @iamcool8304
    @iamcool8304 ปีที่แล้ว +1

    Do you have a video on how I can control a VFD on a compact logix PLC that is connected to a different compact logix?

    • @TimWilborne
      @TimWilborne  ปีที่แล้ว +1

      I'm not following you. Are you saying that they are not on the same Ethernet network?

    • @iamcool8304
      @iamcool8304 ปีที่แล้ว +1

      @@TimWilborne
      I have a L30-ER that is connected to 3 drives, 1 output and one input card. I want my L24ER-QBFC1B to be able to control a drive, and few inputs and a few out puts of the L30-ER.

    • @TimWilborne
      @TimWilborne  ปีที่แล้ว

      @@iamcool8304 Sounds like produced and consumed tags between the L30 and the L24 would be the easiest solution if they are both connected over Ethernet. Here is a video on that.
      th-cam.com/video/ABOAHyLcgSM/w-d-xo.html

    • @iamcool8304
      @iamcool8304 ปีที่แล้ว +1

      OK Tim you passed that challenge with flying colors thank you.
      Now for my next question what if I wanted to control the same two PLCs using one HMI?

    • @TimWilborne
      @TimWilborne  ปีที่แล้ว +1

      @@iamcool8304 Most HMI support more than one controller. You should be fine

  • @keithhoffman-q8q
    @keithhoffman-q8q 19 วันที่ผ่านมา +1

    good video
    i have a question
    i need to know how to get a micro 800 plc to set the powerflex drive parameters on power-up via ethernet/ip or dsi and if any additional hardware is required other than ethernet cables

    • @TimWilborne
      @TimWilborne  19 วันที่ผ่านมา +1

      I don't believe the Micro800s support ADC (Automatic Device Configuration) so it would take quite a bit of work to set the drive parameters. If you need that feature, you probably need to look at a Compactlogix. Here is a video showing that feature. Curious, why do you need to set them on powerup? Is it just in case you need to replace a drive?
      th-cam.com/video/C249NnJ4EmM/w-d-xo.html

    • @keithhoffman-q8q
      @keithhoffman-q8q 19 วันที่ผ่านมา +1

      @@TimWilborne correct,
      in the event of drive failure during production hours the maintenance crew will replace it and when they power up the panel it takes an additional 5 min to program the drive even if they have the "cheat sheet" for that machine
      as far as looking at CompactLogix the company cant afford swap out all the plc's to those at the moment
      the old automation tech was able to do it with a micrologix 1400 and an adaptor (i assume it was for Modbus) to set parameters on a power flex 4
      now just a guess on my part but can you send a write string or word to the powerflex something like a program variable?
      variable "p36" with a value of "5"

    • @TimWilborne
      @TimWilborne  19 วันที่ผ่านมา +1

      We long as the parameters are limited, it would be possible

    • @keithhoffman-q8q
      @keithhoffman-q8q 18 วันที่ผ่านมา +1

      @@TimWilborne outstanding, i think i would not need more than 5 parameters such as a preset speed, start source, and basic motor parameters like FLA etc.

  • @flaviomartins48
    @flaviomartins48 3 ปีที่แล้ว +1

    otimo ja me ajudou.

    • @TimWilborne
      @TimWilborne  3 ปีที่แล้ว +1

      Você é bem vindo

  • @shapoorkosarimehr9404
    @shapoorkosarimehr9404 3 ปีที่แล้ว +1

    Hi TIM
    I am starting a new project with a 1769-L24ER controller. I connected up to the USB port and did a firmware flash to V21.011. Everything seemed to go normal. At the end the controller would not communicate back to the ControlFlash program that it had the new version.
    Now I get the solid red OK light and when I power it up it wont do the diagnostic test where it will runs through and lights all the lights. The USB port wont work either.
    Any ideas

    • @TimWilborne
      @TimWilborne  3 ปีที่แล้ว +1

      The firmware upgrade failed. Time to call Rockwell, it will need to be sent back.

  • @LearningInVR
    @LearningInVR 3 ปีที่แล้ว +1

    Only have version 20 of studio 5000 /
    . Will trainer work with this version(20)
    If not I gotta go ccw 12 / micrologix 800 / logic theme but I rather compactlogix .... which is ideal but I cannot get the proper version new at work .... only service version its 789 so I don't think it's the right one to program and train with but I have a full version 20 pro

    • @TimWilborne
      @TimWilborne  3 ปีที่แล้ว +1

      Yes, version 20 is the minimum version that will work with our trainers.

  • @guangyaoli6218
    @guangyaoli6218 7 หลายเดือนก่อน +1

    Boss. When i meet two enthernet cards in plc with different ip address. Which ip address i should set up in my pc for matching? Thank you ceru much!

    • @TimWilborne
      @TimWilborne  7 หลายเดือนก่อน +1

      The one that is on the network that you are plugging into.

    • @guangyaoli6218
      @guangyaoli6218 7 หลายเดือนก่อน +1

      @@TimWilborne thank you boss

    • @TimWilborne
      @TimWilborne  7 หลายเดือนก่อน

      You are welcome

  • @justinpuzak2558
    @justinpuzak2558 3 ปีที่แล้ว +1

    can i program a compact logix l32e with studio 5000 lite, (the 950$ version you were talking about)
    im going buy that version but i only have a compact logix l32e to practice on and dont know if they're compatible...
    also. i told my boss at hershey about your classes and hes very interested. we are waiting till they hire 2 more guys to set up classes for everyone. do you have a buisness email i can give to my boss incase he has any questions.

    • @TimWilborne
      @TimWilborne  3 ปีที่แล้ว +1

      You could also use Mini if you are only programming in ladder. You can find more about our PLC training at twcontrols.com/plc-lab

  • @benedalati1527
    @benedalati1527 ปีที่แล้ว +1

    Hi Tim, Thanks for the video. I have done all of the steps in it. I can ping my controller from my PC and when I check the ip address of the drive it is 192.168.1.12 in the same subnet as the controller 192.168.1.10 and my PC. But I am getting communication error when I click on the connection tab of the drive. Don't know why? Thanks again

    • @TimWilborne
      @TimWilborne  ปีที่แล้ว +1

      What is the error? Also, can you ping both of them from your PC?

    • @benedalati1527
      @benedalati1527 ปีที่แล้ว +2

      @@TimWilborne the error message is communication error, no number. No i can't ping the PF. Thanks

    • @TimWilborne
      @TimWilborne  ปีที่แล้ว

      @@benedalati1527 If you can't ping the Powerflex then you need to hit the basics. Here is a video to help.
      th-cam.com/users/liveW7Q5ZgvEWiw

  • @Victor_Sj
    @Victor_Sj 3 ปีที่แล้ว +1

    Hi, i would like to change a powerflex 525 installed for other new one, but after It's configured, the ethernet led port only flashing and not connect to the net to recive and manage the vfd via ethernet?
    thancks

    • @TimWilborne
      @TimWilborne  3 ปีที่แล้ว +1

      Sounds like you need to double check the IP address configuration.

    • @Victor_Sj
      @Victor_Sj 3 ปีที่แล้ว

      @@TimWilborne But the parameters ip and mask net are correct

  • @benedalati1527
    @benedalati1527 ปีที่แล้ว +1

    At 4:43, you mention downloading the program. What program? I put the parameters in the powerflex manually following your previous video. Was i supposed to write a simple start stop program and downloaded it to the controller? what should my output be? one more, can i delete the pwerflex drive and create one the way you show here. I wanted to delete it and start fresh but got a mesage"Are you sure you want this module and all og its child to be deleted?" sounds scary? Thanks for all of your informative videos. I am new to this and already have learned a lot by watching them. regards
    Ben E

    • @TimWilborne
      @TimWilborne  ปีที่แล้ว +2

      Not following your question Ben. The program we made from 0:00 to 4:42 of this very video is what you are downloading.

    • @benedalati1527
      @benedalati1527 ปีที่แล้ว +1

      Hi Tim, Thanks for the reply. What I am asking is which program you are referring to. i don't see you doing any program but you say let's download ( the program ??). Did you write a program. Do mind posting it along with the wiring for the input and output. I hope my question makes sense. Regards
      Be

    • @TimWilborne
      @TimWilborne  ปีที่แล้ว

      From 0:00 to 4:42 we created a program and added the drive to the configuration. I'm still not following you.

  • @smartpaco8360
    @smartpaco8360 2 ปีที่แล้ว +2

    If the 525 is not on the list, how is it possible to add it?

    • @TimWilborne
      @TimWilborne  2 ปีที่แล้ว +1

      Are you right clicking "Ethernet" then selecting new module? This brings up a different list than adding standard I/O.

    • @smartpaco8360
      @smartpaco8360 2 ปีที่แล้ว

      Yes, I have other powerflex devices but not 525 unfortunately

  • @tonymontero4752
    @tonymontero4752 3 ปีที่แล้ว +1

    hi TIM i am wonder can we program VFD BY RSL 500 software i looked at controller i didnt see
    thank you

    • @TimWilborne
      @TimWilborne  3 ปีที่แล้ว +1

      Program as in set the parameters? Possible but very difficult. Run? Yes, you can use messaging instructions.

    • @tonymontero4752
      @tonymontero4752 3 ปีที่แล้ว +1

      @@TimWilborne thank you but I was looking for controler at software but I couldn’t find
      Also one more question pleas if we have any other typ VFD like Siemens can we program it by RSL5000 or should be just Allen Bradley
      Thank you

    • @TimWilborne
      @TimWilborne  3 ปีที่แล้ว +2

      @@tonymontero4752 The Powerflex 525 can be programmed with Connected Component Workbench. Siemens has its own software as far as programming.

    • @tonymontero4752
      @tonymontero4752 3 ปีที่แล้ว

      @@TimWilborne thank you

    • @tonymontero4752
      @tonymontero4752 3 ปีที่แล้ว +1

      Do u have video shows how to program power flex by connected work bench
      Thank you

  • @davem5392
    @davem5392 3 ปีที่แล้ว +1

    I had many problems following this video i wanted to list some things for others who have the trainer and their Studio 5000 may have locked up and sent many errors to AB. I changed many things not 100% sure what did what.
    Program would not download deleted ethernet connection, only left ethernet IP active and changed to windows default driver. Took HMI out of run on config screen. The program seems to have problems with blank spaces on PLC and Drive descriptions.
    When downloaded I tried to double click on drive it stopped like yours but my powerflex connection was grayed out in use physical so i had to use project. Then I got error writing port 0 Parameter 122 value out of range. I clicked ok and then double clicked drive and all loaded properly.
    Also for others with trainer steps in video may not work for instance buttons on drive because this is already changed in drive to ethernet IP.
    Really not 100% sure how i got myself in so many problems but maybe some of these steps will help others

    • @TimWilborne
      @TimWilborne  3 ปีที่แล้ว +1

      Hi Dave. Yours should have already been set up for this but I know we had some issues with IP addresses. Try doing a factory reset as shown in the following video and see if that smooths out the steps.

  • @alxdufour
    @alxdufour 10 หลายเดือนก่อน +1

    awesome

    • @TimWilborne
      @TimWilborne  10 หลายเดือนก่อน +1

      Thanks!

  • @christopherdean2893
    @christopherdean2893 3 ปีที่แล้ว +1

    This is what I see more and more in the field. Most drives are controlled over ethernet

  • @user-zf8wu5iw2p
    @user-zf8wu5iw2p 10 หลายเดือนก่อน +1

    Failed to splice the path errror PF525??

    • @TimWilborne
      @TimWilborne  10 หลายเดือนก่อน +2

      It usually means no connection or firmware mismatch. Can you ping the drive? What is your IO Light doing?

    • @user-zf8wu5iw2p
      @user-zf8wu5iw2p 10 หลายเดือนก่อน +1

      @@TimWilborne Actually my drive is healthy ,but ot didnot accept command from ethernet ip communication,so i reset it to default.I tried your communication video step by step but no response ,but when i change ip it doesn't ping and didn't showing in RS links.I tried to set ip at automatic in my pc,but its not communicate.

    • @TimWilborne
      @TimWilborne  10 หลายเดือนก่อน +1

      If you can't ping it then you need to check your network configuration.

    • @user-zf8wu5iw2p
      @user-zf8wu5iw2p 10 หลายเดือนก่อน +1

      Thanks for your kind attention and Support 😊🙏.Error solve.Vfd run over ethernet.

    • @TimWilborne
      @TimWilborne  10 หลายเดือนก่อน +1

      Outstanding! What did you find?

  • @Time-Trvlr
    @Time-Trvlr 3 ปีที่แล้ว +1

    It gets fun when altering the mask ie 255.255.0.0

    • @TimWilborne
      @TimWilborne  3 ปีที่แล้ว +2

      I'm thinking I might to a video on subnets Joel.