WaterBoss Water Softener Clean Flow Control & Brine Piston 9 Easy Steps

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 ธ.ค. 2024

ความคิดเห็น • 68

  • @Plinktitioner
    @Plinktitioner 7 หลายเดือนก่อน

    I cannot thank you enough for these instructional videos, Gary! Five years later, they are still doing good work

    • @water_estore
      @water_estore  7 หลายเดือนก่อน

      Glad to hear they are helpful. Please share video with friends and family.

  • @DarkpawTheWolf
    @DarkpawTheWolf 3 ปีที่แล้ว +1

    This was SUPER helpful. Was about to pay for a service call until I saw how easy this was. Took apart my Aquamaster, cleaned it all up, and it works like a champ again. Thank you so much for these tips.

    • @water_estore
      @water_estore  3 ปีที่แล้ว

      Glad it helped! Please share with friends and family.

    • @nickboardman4295
      @nickboardman4295 8 หลายเดือนก่อน

      My tank is filling with water , will this fix solve my issue ?

  • @Xflysx11
    @Xflysx11 5 ปีที่แล้ว +8

    How much water is “too much” water in brine tank of a Water Boss 900?

  • @nancibishof6462
    @nancibishof6462 5 หลายเดือนก่อน

    Thank you for sharing your knowledge. I have twice successfully repaired my WaterBoss 900 by watching your videos.

    • @water_estore
      @water_estore  5 หลายเดือนก่อน

      Great to hear! Please share video with friends and family.

  • @714Roostergirl
    @714Roostergirl 2 ปีที่แล้ว

    Very helpful video

    • @water_estore
      @water_estore  2 ปีที่แล้ว

      Thank you very much! Please share video with friends and family!

  • @kylebartlett608
    @kylebartlett608 3 ปีที่แล้ว +1

    I'm thinking this might be my problem, but i'm not sure. My tank is full of water so I'm looking for a place to start, already cleaned the injector but not sure if once that was cleaned I should run it through regeneration?

    • @water_estore
      @water_estore  3 ปีที่แล้ว

      Yes, run it through a regeneration and keep an eye on it.

    • @kylebartlett608
      @kylebartlett608 3 ปีที่แล้ว

      @@water_estore So I drained some water out and ran a regeneration, it ended up filling up to the high level again, any ideas?

  • @Sparky_0419
    @Sparky_0419 8 หลายเดือนก่อน

    Hey gary my water boss 950 knob that goes from service to bypass turns 360 degrees. Tank is full of water where salt is also

    • @water_estore
      @water_estore  8 หลายเดือนก่อน

      Sounds like you might need a new bypass, we have them waterestore.com/products/aquamaster-bypass-assembly-54512-ams-700-900-or-950

    • @Sparky_0419
      @Sparky_0419 8 หลายเดือนก่อน

      Thanks for the reply. Your video helped me relieve the pressure and install a new 950. I had the old for about 10-12 years. Thanks 👍🏾

  • @drewreinvestor7102
    @drewreinvestor7102 2 ปีที่แล้ว

    What about pouring a super iron out water solution into the brine tank? And possibly the main tank you add the salt too?

    • @water_estore
      @water_estore  2 ปีที่แล้ว

      I would only do that in extreme situations. It will be difficult to get rid of the iron out if you use too much.

  • @m.m.m.c.a.k.e
    @m.m.m.c.a.k.e 2 ปีที่แล้ว +1

    My WB900 worked great for years. However; problem now after regeneration cycle, causes yellow to orange water. What do I need to do to fix this?

    • @water_estore
      @water_estore  2 ปีที่แล้ว +1

      Great question. You have iron in your water. you need to change the programming from metered to regen every 72 - 96 hours of use at least for a few weeks. After that you can go back to metering.

    • @m.m.m.c.a.k.e
      @m.m.m.c.a.k.e 2 ปีที่แล้ว

      @@water_estore Gary you are an alright guy! Did ya know that? Ha ha, appreciate your work Mr. water guy!! I’ll give that a shot and see what happens! I’ll have to re-watch one of your videos that shows how to properly account for hardness. I think mine allows 15-99.

    • @m.m.m.c.a.k.e
      @m.m.m.c.a.k.e 2 ปีที่แล้ว

      @@water_estore hey Gary, the color is almost minimal at this point after a generation!
      But the water stinks like rust. This “WaterBoss 900” is of 12 yr and processed approx 1,500,000 L; should resin media be replaced? Do ya have a tear down video showing how??
      As always thank you so much 😊

  • @threecats407
    @threecats407 3 ปีที่แล้ว

    Great videos Gary. I would only say that before anyone attempts this stuff they should have new o-rings on hand. It's one thing watching you instruct on a brand new unused unit and another thing with years old o-rings.

    • @water_estore
      @water_estore  3 ปีที่แล้ว

      Yes, that is great advice!

  • @honeybear373
    @honeybear373 3 ปีที่แล้ว

    Completed these steps and the other video about cleaning the injector for my waterboss iron filter. Nothing appeared very dirty but regardless, it seemed to do the trick and now is operating as it should. Thank you for the tips and guide through - waterboss themselves don't offer much help.

    • @water_estore
      @water_estore  3 ปีที่แล้ว

      Glad it helped! Please share video with friends and family!

  • @ashoknimmagadda4095
    @ashoknimmagadda4095 3 ปีที่แล้ว

    Hello Gary,
    Thanks for the great video series. I tried cleaning the flow valve and also using ironout to clean and flush out. Still no avail. Any advise is appreciated

    • @water_estore
      @water_estore  3 ปีที่แล้ว

      What is your concern with the water softener?

    • @ashoknimmagadda4095
      @ashoknimmagadda4095 3 ปีที่แล้ว

      @@water_estore I tried the iron-out, cleaning out the flow valve and used res care and in vain. Ran out of options on water boss 950(14 yrs old unit). What is my alternative?
      Thanks for the advice and great TH-cam video collection

  • @niknikktm
    @niknikktm 3 ปีที่แล้ว +1

    I've checked my flow control and it's clean but I'm still having issues with my Waterboss 380. I have a well with high iron content (10 ppm) and had the settings dialed in and it worked perfectly for 6 years. I've put it in powerclean mode every 6 months and twice a year run some Iron out mixed with water through it and everything was working fine. Now for some reason when I let my tap run it alternates like clockwork: one minute it's crystal clear and the next minute its cloudy and yellow. You could set a clock to it. It's almost exactly one minute for each state. I let the water run for over a half hour and its still clear for a minute then cloudy for the next minute and back again. Of course it has plenty of salt and regenerating doesn't help. What could possibly cause it to alternate back and forth like that? That unique symptom seems like it ought to be a dead giveaway for a particular failure but I can't find any info relating to it.

    • @water_estore
      @water_estore  3 ปีที่แล้ว

      I have never seen this happen but I tend to think the media must be exhausted by now.

    • @patrickgarrison8847
      @patrickgarrison8847 2 ปีที่แล้ว

      I had the same thing happen to me. Extreme iron at my house and waterboss told me to run and entire bottle of iron out and let it regenerate. When it gets to number 2 during regeneration on controller wait 15 to 30 seconds and unhook the power and let it run for 1 hour. I always do 2 hours and it cleans the media very well. I also use 1/2 cup iron out once a month and switched over to Morton’s green bag with rust preventative in it. It fixed my problem and no more brown water.

  • @bluelinewall640
    @bluelinewall640 4 ปีที่แล้ว

    When the dial turns, I get high pressure water leak from that area, can you advise me on what part or assembly to purchase, I realize that is difficult to answer. Thank you

    • @water_estore
      @water_estore  4 ปีที่แล้ว +1

      Likely you need a new Drive End Cap Assembly here waterestore.ca/products/aquamaster-drive-end-cap-assembly-54520?_pos=222&_sid=f3a739624&_ss=r

    • @bluelinewall640
      @bluelinewall640 4 ปีที่แล้ว

      @@water_estore thanks for the reply. I can see it dripping from the piston nipple and had already ordered the piston assembly from you already! LoL

  • @williamleahy1956
    @williamleahy1956 3 ปีที่แล้ว

    Hi Gary. I have a WaterBoss 950. I get air in my water lines after the unit regenerates. Any ideas on what would be causing this? Thank you.

    • @water_estore
      @water_estore  3 ปีที่แล้ว

      Yes, I have come across this before. You need to replace part number 100240937 Air Check, 900, 950. Email us with your address and we can get you a quotes info@waterestore.com

    • @williamleahy1956
      @williamleahy1956 3 ปีที่แล้ว

      @@water_estore Thank you for your response. I'll look at that part and see if I can find out if it's bad. I will let you know. Thanks again!

  • @00a00-h5m
    @00a00-h5m 2 ปีที่แล้ว

    Is there an easy fix to a 2yo ProPlus380which does not refill the tank with water? HJ

    • @water_estore
      @water_estore  2 ปีที่แล้ว

      You would need to go through the trouble shooting steps but make sure obvious things first like the water softener isn't bypassed.

  • @RC-ig9ce
    @RC-ig9ce 2 ปีที่แล้ว +1

    I have a water boss 900. The tank that holds the salt has some debris/ dirt . Is there a way to flush the salt tank after I wipe the walls?

    • @water_estore
      @water_estore  2 ปีที่แล้ว +1

      You can use a shop vac

  • @emmiefrye
    @emmiefrye 3 ปีที่แล้ว

    I have a Water Boss 700 that is about 15 years old. The brine tank is filled with water and my water is so salty, it is undrinkable. It dissolved two 25 pound bags of water in about a week!!!! I normally don't drink tap water but use it for making coffee and could not understand why my coffee tasted so bad. I took a pill with tap water and could not believe how salty my water is. I have been filling my cats water bowl with this stuff. There is no way I can service the unit myself. Should I just buy a new unit since mine is so old. Thanks Gary for your very informative videos.

    • @water_estore
      @water_estore  3 ปีที่แล้ว

      If you can't service it and have no one who can, yes, I would buy a new one like this waterestore.ca/products/hum-deluxe-water-softener-30-000-grain

  • @christophergranger9278
    @christophergranger9278 2 ปีที่แล้ว +1

    I have too much water in my Water Boss 950 Brine Tank. Happened out of the blue... Never had issues before. I've taken out the injector and cleaned it with a tooth pick.. no obvious clogs. I've also taken the brine piston out cleaned everything and reinstalled. It still has water in the brine tank... Not sure what else I can do?

    • @water_estore
      @water_estore  2 ปีที่แล้ว

      Did you check out the advice in this video? th-cam.com/video/ZdA0aI1q22w/w-d-xo.html

    • @christophergranger9278
      @christophergranger9278 2 ปีที่แล้ว

      @@water_estore thanks for this... I believe I missed this video. I wonder if my brine tank needs cleaned? It's never been ran out of salt and I did have to substitute with rock salt at one point. I have done a Regen cycle and it went right back to the same water level after I cleaned the float, cleaned the brine piston and injector. When I put the float back in after cleaning I did notice it being very difficult to get that nut back on... Which now makes me wonder if there's settled salt on the bottom. Don't have time to check this for a few days but do you think I'm on the right track?

  • @trymo9141
    @trymo9141 6 ปีที่แล้ว

    Nice video tutorial sir.. But i think its not here in the Philippines yet,, just love watching plumbing videos.. 👍🏻👍🏻👍🏻

  • @davecarr8476
    @davecarr8476 4 ปีที่แล้ว

    How do I get it out of p.c. mode and back to normal service

    • @water_estore
      @water_estore  4 ปีที่แล้ว

      This video should help you th-cam.com/video/Km2yAt18oFU/w-d-xo.html

  • @Fsjfor
    @Fsjfor 3 ปีที่แล้ว

    Thank you very much for posting this video. Nice set of step by step instructions - got the job done! The extra step of taking the brine tube/float system out was a good suggestion as it caused me to discover a salt bridge in the bottom of the brine tank and brine well which I then removed! It was quite a pain to clean out all that bridged salt to be honest, but it was a necessary step!

    • @water_estore
      @water_estore  3 ปีที่แล้ว +1

      Glad it helped! Please share with friends and family.

  • @raulmora654
    @raulmora654 4 ปีที่แล้ว

    My water in the brine take is brown and foamy after regeneration. What would cause this?

    • @water_estore
      @water_estore  4 ปีที่แล้ว

      You must have some iron or tannins in the water and it is reacting the the brine.

  • @peterrabid2749
    @peterrabid2749 4 ปีที่แล้ว

    Have had a buildup on the piston shaft causing the piston to seize

    • @water_estore
      @water_estore  4 ปีที่แล้ว

      you will need to repalce the drive end cap assembly, this video shows you how th-cam.com/video/8UUG6iV3N-s/w-d-xo.html

  • @mytube8630
    @mytube8630 3 ปีที่แล้ว

    Anyone know how to reset the display on a water boss 700
    I think it has something like 01 on the display . Push buttons and it just shows a hardness setting. I think 15
    I did plug out of wall socket and also from the controller .
    Unless it has to be left out for a minute ?
    Left out upto 10secs atleast to reboot it .
    Still the same.

    • @water_estore
      @water_estore  3 ปีที่แล้ว

      You need to unplug it for 60 seconds and then plug it back in.

    • @mytube8630
      @mytube8630 3 ปีที่แล้ว

      @@water_estore thanks for that , will give it a go .👍

  • @Bullet1979
    @Bullet1979 ปีที่แล้ว

    I've been following your guides to try and troubleshoot my issues and putting my Waterboss 900 (looks like the AquaMaster in this video) in Bypass Mode and regeneration mode does not seem to release the pressure. I've waited for the unit to complete step 1 and when I unplug the controller the unit continues to run water and if I start unscrewing the first screw, water starts gushing out. I have the same behavior if I try and remove the cap to inspect the injector. Does this mean the valve is malfunctioning and is not switching into Bypass Mode?

    • @Bullet1979
      @Bullet1979 ปีที่แล้ว

      The issue I'm trying to resolve is the water level is very high and the unit does not seem to be treating our water. I have emptied the brine tank prior to troubleshooting, but the unit is adding water to the brine tank when regenerating in Bypass Mode.

    • @water_estore
      @water_estore  ปีที่แล้ว

      When you start the regeneration and then bypass the water softener the pressure isn’t being released? Is that correct? If not there must be something wrong with the bypass. You could always try shutting off the water before the softener and then start a regeration. That would also release the pressure

    • @Bullet1979
      @Bullet1979 ปีที่แล้ว

      @@water_estore I wondered about that… I’ll give that a shot for troubleshooting the issue with not treating the water. I don’t suppose you have any videos/advice for correcting the issue with the bypass? I had emptied the tank of all water and salt and left it in bypass but the whole tank was full of water a few hours later

  • @bridgettaylor2508
    @bridgettaylor2508 4 ปีที่แล้ว

    Can i do this while there is salt and water in the tank? Or does it have to be empty

    • @water_estore
      @water_estore  4 ปีที่แล้ว +1

      Great question! You can do it at any time.

  • @jeb1982
    @jeb1982 ปีที่แล้ว +1

    This was not helpful at all since the example he is showing is not even hooked up.

    • @water_estore
      @water_estore  ปีที่แล้ว

      That might be true but it is significantly better than nothing

    • @jmabs5096
      @jmabs5096 8 หลายเดือนก่อน

      Your comment is not helpful at all, where is your detailed video demonstration?