I have the same setup and my 2nd Distributor (out going power side) is not recognized by the BMS. Do I need to toggle jumpers on one of the distributors? Or?
Can you tell me which relay is controlled by the soft switch on the Cerbo GX GUI? It's called Relay 2 but I'm not sure which device its controlling. There are relay outs on my Cerbo, Lynx BMS, and Inverter/charger.
Hello and barvo for the video I wanted to ask you if it is possible to install the bms from victron (16S for a packlife that I have in 48 volts? 600AH)? or do you have to have a victron battery? my batteries are EVE 280AH in 16/2P can we wire all the batteries with the bms from victron or do we need a bms compatible with the victron? otherwise is it possible if there is no can in the battery pack to tell victron (multiplus and cerbo GX) that I have a lead gel battery pack? there is no bms on the lead in general? my pack can be protected by its own BMS cutoff 2.80 volts and maximum charge at 3.65 volts Possibly just to emit more or less on the multiplus? thank you laurent
Hello I have another question about the lynx distributor on my solar installation I have 5 strings so 5 mptt smarsolar 150/35 they all have their 40A mega fuse fuse I was wondering if it was possible to connect the 5 smarsolar 150/35 directly to a lynx connector with a 200A fuse? possible? because otherwise I have to buy 2 lynx (expensive) to connect 4 individual smart solar (6MM²) on each lug of the first lynx and 2 others on the second lynx with the multiplus 800VA in all 7 locations on the 2 lynx no risk of gathering all the mptt in 6MM on 1 lug of 50MM²?
@@laurentsosson1739 I would recommend connecting something to the distributor for instance for each charger to connect that wire to the distributor but putting a midi fuse by it so it fuses down
Good info. I’m going to do some cabinet work and rewire my system. It takes some planning to get it all to fit neat and compact.
Very helpful information
Glad it was helpful!
I have the same setup and my 2nd Distributor (out going power side) is not recognized by the BMS. Do I need to toggle jumpers on one of the distributors? Or?
Can you tell me which relay is controlled by the soft switch on the Cerbo GX GUI? It's called Relay 2 but I'm not sure which device its controlling. There are relay outs on my Cerbo, Lynx BMS, and Inverter/charger.
Hello and barvo for the video
I wanted to ask you if it is possible to install the bms from victron (16S for a packlife that I have in 48 volts? 600AH)?
or do you have to have a victron battery?
my batteries are EVE 280AH in 16/2P
can we wire all the batteries with the bms from victron or do we need a bms compatible with the victron?
otherwise is it possible if there is no can in the battery pack to tell victron (multiplus and cerbo GX) that I have a lead gel battery pack?
there is no bms on the lead in general?
my pack can be protected by its own BMS cutoff 2.80 volts and maximum charge at 3.65 volts Possibly just to emit more or less on the multiplus?
thank you
laurent
The Victron BMS range are for Victron batteries only, sorry.
Hello
I have another question about the lynx distributor
on my solar installation I have 5 strings so 5 mptt smarsolar 150/35
they all have their 40A mega fuse fuse
I was wondering if it was possible to connect the 5 smarsolar 150/35 directly to a lynx connector with a 200A fuse?
possible? because otherwise I have to buy 2 lynx (expensive) to connect 4 individual smart solar (6MM²) on each lug of the first lynx and 2 others on the second lynx with the multiplus 800VA in all 7 locations on the 2 lynx
no risk of gathering all the mptt in 6MM on 1 lug of 50MM²?
@@laurentsosson1739 why do you want multiple charge controllers? Have you considered getting one big one?
HELLO
no I don't have the same PV everywhere and not all the same brand on the roof but in different places?
@@laurentsosson1739 I would recommend connecting something to the distributor for instance for each charger to connect that wire to the distributor but putting a midi fuse by it so it fuses down