How do heat pumps work? You put in 1 kW and get out 5 kW!
āļāļąāļ
- āđāļāļĒāđāļāļĢāđāđāļĄāļ·āđāļ 18 āļ.āļ. 2023
- 00:01:19 - How does a heat pump work?
00:06:47 - Myths about heat pumps.
00:06:49 - Heat pumps don't work (well) in cold areas.
00:07:13 - You absolutely need to have a well insulated house before you can install a heat pump.
00:07:44 - Heat pumps are noisy.
00:08:10 - Heat pumps must run non-stop.
00:08:44 - Heat pumps need a lot of maintenance.
00:09:10 - Heat pumps only work with underfloor heating.
00:09:56 - Heat pumps take up a lot of space.
00:10:20 - Heat pumps are only used for heating.
00:10:46 - Heat pumps can only be installed in new constructions.
00:11:19 - Heat pump technology is too new and hasn't had time to be tested.
00:11:51 - Limitations and constraints - not everything is rosy.ðļ SUPPORT FINANCIALLY ON PATREON âš / cristianpresura
ðļ BECOME A TH-cam MEMBER âšbit.ly/35Q8vXC
ðļ PAYPAL âš paypal.me/cristianpresura
ðļ DONORBOX âš donorbox.org/cristianpresura - āļ§āļīāļāļĒāļēāļĻāļēāļŠāļāļĢāđāđāļĨāļ°āđāļāļāđāļāđāļĨāļĒāļĩ
sunt din ce in ce mai neprost cu fiecare filmulet al dumneavoastra. multumesc frumos! ð
super clar!ðMulČumesc!
Multumim Cristian pentru prezentarea foarte detaliata!
ð
Multumim pentru prezentare ,profesionista ,
Excellenta descrierea. Felicitari si succes in continuare!
MulČumesc !
Felicitari,o prezentare reusita,multumim!
E o placere sa va urmÄresc. Mii de mulČumiri.
imi plac foarte tare explicatiile dvs.
va urez multa sanatate si putere pentru cat mai multe clipuri.
In opinia mea canalul asta este in top 5 canale pe youtube, worldwide. Multumim pentru toata informatia pe care ne-o transmiteti :)
MulČumim!
Multumim pentru sustinere.
Eu in Octombrie 2023 m-am hotarat sa iaau pompa de caldura (de cand am inceput casa aveam dubii de care centrala sa iau-gaz, peleti sau pompa),
Am ales Midea Vision by Romstal de 12KW modelul split. Cost 17.000 de lei doar pompa si inca 10.000 de lei manopera, vas, robineti, etc. Cea mai buna alegere am facut si sunt super multumit. Toata casa are incalzire in pardoseala si momentan incalzesc doar parterul (110 m2 utili) si consuma in noiembrie-decembrie cam 27KW pe zi. M-am mutat la hidroelectrica tot in Octombrie si am pretul de la 1.3 lei pe KW de la hotii de la Enel tocmai la 0.76 lei pe KW.
In medie o pompa de caldura consuma pt o casa obisnuita cam 1000 KW pe luna, iar la noi cum sunt iernile blande sa zicem ca pompa merge 6 luni pe an si ar veni undeva la 4000 de lei cost incalzire.
Recomand investitia tuturor, cant tragi linie iesi mai bine ca oriice alta modalitate de incalzire si la costurile lunare si la instalare, iar cine vrea panouri solare sa stea potolit mai bine ca isi va scoate banii greu si cea mai buna manevra este schimbarea distribuiorului de energie (plus ca acum au redus si banii din casa verde pentru fotovoltaice)
Multumim pentru video!
Deci 27 kW x 0.73 lei = 19.71 lei / zi adica 591.30 lei / luna pentru a incalzi o casa de 110 m2 si asta cu o investitie de 27.000 lei, corect? Eu in Decembrie 2023 am platit la Enel pentru gaze 475.00 Lei si incalzesc o casa de 200 m2, investitia initiala - o centrala termica pe gaz. Care este avantajul dumneavoastra?
Extraordinar, cat de frumos puteti explica. Asta inseamna sa intelegi perfect fenomenul, sa poti sa i-l explici unui copil pe intelesul lui. Multumim pentru munca depusa!
Tatal meu spunea cand avem vre-o 20 de ani o fraza, pe care, astazi la 34 de ani, fiecare atom din mine o intelege: "daca nu poti sa explici ceva complex in cateva cuvinte, pe intelesul tuturor, astfel incat si un copil de 7 ani sa inteleaga principiul, inseamna ca nici tu nu il intelegi prea bine".
@@Flavioshine sunt de acord, e cÃĒt se poate de adevÄrat.
BunÄ. Ãmi pare nespus de bine cÄ aČi atins acest subiect care mÄ pasioneazÄ pe mine se vreo cinci ani. As dori sa faceČi o comparaČie ÃŪntre pompele sol-apa Či cele aer-apa, avantaje Či dezavantaje.
Va mulČumim!
Practic, adevarat si fara ocolisuri, pompa de caldura este o ideie de afacere pentru afaceristi.
Foarte frumos explicat. Desi m-a framantat mult subiectul in trecut, din explicatia frumoasa a domnului profesor avem ce invata.
Ca sa venim cu o alta explicatie, putem face referire la *Legea generala a gazelor* care poate explica foarte clar fenomenul, de fapt caldura primita din exterior este egala cu caldura cedata in interiorul casei, doar parametrii P1V1/T1 se modifica in parametrii P2V2/T2, evident aici facand abstractie de pierderea de energie mecanica a compresorului transformata si ea intr-o mica parte de energie termica, dar infima in comparatie cu energie termica culeasa din exterior.
Din punct de vedere al eficientizarii folosirii energiei, la nivel european, chiar este o mare problema, pentru ca tehnologii de tipul pompelor de caldura, pot functiona mai eficient in tarile cu clima mai calda, asta in comparatie cu regiunile reci ale Europei.
DeČi am avut idee de ce ÃŪnseamnÄ o pompa de cÄldurÄ este plÄcere sÄ asculČi expunerea . MulČumim pentru efortul de a explica . Poate fi un exemplu pentru toČi cei ce transmit informaČii ! (Din pÄcate mulČi din cei ce ÃŪncearcÄ sa explice-inclusiv unii profesori- ,,nu Čtiu cÄ nu ÃŪnČeleg ei despre ce este vorba "
Multumim domnul Cristian, ar fi minunat daca ne-ai explica mai multe despre compresor Či valva de expansiune , par foarte interesante ðĨ°
Foarte frumos explicat.
Din cÃĒte Čtiu freonul este interzis.
Poate se folosesc alte gaze sub denumirea genericÄ de freon.
Foarte bine explicat domnule Presura,mai trebuie completat ca datorita vaporizatorului compresorul poate comprima freonul (doar gazele pot fi comprimate),iar gazele sub presiune ÃŪČi cresc temperatura.
Freonul dupÄ comprimare are mai mult de 60 de grade.
Partea asta nu am inteles-o dar , acum am inteles , mersi
@@ikp22.fericireaestegrea13 Desi pare simplu, treaba este ceva mai complicata. Este foarte corect ce a spus @tincaionut4111 , doar gazele sunt compresibile si pot sa-si schimbe starea in functie de temperatura la care se afla. Lichidele nu sunt compresibile, ele doar primesc si cedeaza caldura pe baza proprietatii fizice de CAPACITATE TERMICA sau CAPACITATE CALORICA, deci iau caldura de la sursa calda si o elibereaza la sursa rece pe baza gradientului de temperatura (diferentei de temperatura). Folosind proprietatea gazelor de a se comprima , se poate genera caldura cu ajutorul unui gaz. Un exemplu banal este pompa de la bicicleta sau masina. Cand noi apasam pe manerul pompei in corpul pompei generam presiune , prin micsorarea spatiului intre pistonul mobil si corpul pompei, de fapt noi crestem presiune prin reducerea spatiului. Aici au loc doua fenomene:
1) crestem presiune prin micsorarea spatiului din corpul pompei
2) prin comprimare fluidului (atentie , nu lichid) creste agitatia moleculelor din spatiu respectiv si implicit crestem temperatura.
Asta e frumusetea fenomenelor fizice pt gaze . In acest fel putem sa folosim gradientul de temperatura al fluidului respectiv astfel incat sa mutam caldura din A in B dar daca sistemul este cu invertor putem la fel de bine sa mutam caldura si din B in A. Adica procesul bidirectional - asta fac pompele de caldura cu dublu flux sau dublu sens.
Suplimentar ca informatie, se foloseste freonul pentru a maximiza aceasta proprietate de transfer de caldura din A in B sau invers cu consum cat mai mic de energie. Se poate utiliza si etanol, alcool sau alte fluid cu proprietate de vaporizare. Bafta
da e buna legatura, se intelege mai bine si de ce ii spunem vaporizator, multumesc!
Cat este durata de viata a unui compresor,aproximativ?
@@maximilianmusat4938 ca Či orice obiect,depinde de cÃĒt ÃŪl foloseČti,in pruncipiu compresoarele de generatie noua ar trebui sa tina mai mult,adica 10 ani sau mai mult,deoarece ele nu se mai opresc complet ci doar ÃŪČi micČoreazÄ viteza.Compresoarele sunt de douÄ tipuri(de astea stiu eu);on-off este modelul vechi cu piston Či modelul mai nou cu scroll sau Čurub
Ãn acest video lipseČte clasificarea pompelor de cÄldurÄ. Tipul de pompÄ prezentat este aer- apa. Dar care totuČi la o pompÄ de cÄldurÄ de nivel mediu, sub -10 gr.C, randamentul scade destul de mult astfel ÃŪncÃĒt pompa devine ineficientÄ Či atunci trebuie sÄ ai Či varianta clasicÄ de CT pe gaz.
Dar o pompÄ de cÄldurÄ eficientÄ este cea sol - apa, cu energie luatÄ din pÄmÃĒnt de la o adÃĒncime de 118 m, ceea ce poate asigura preparare de cÄldurÄ Či ACC la orice temperaturÄ exterioarÄ. Sondele subterane sunt bÄgate ÃŪn foraje special fÄcute ÃŪn acest sens.
Un video cu un subiect pe domeniul meu de specializare Či foarte bine documentat. FelicitÄri!
Avem la firma de peste 12 ani pompa sole-apa,cu foraj la 150m,cladirea are 70% incalzire pardoseala 30% radiatoare,in toti acesti ani a functionat centrala pe gaz in condensatie,fiindca a fost mai rentabil.
@@haribo245 Da, ÃŪntr-adevÄr este mai eficientÄ CT pe gaz, mai ales dacÄ ai Či preparare de apÄ caldÄ iar locaČia centralei este ÃŪn zona III sau IV de frig a RomÃĒniei unde temperaturile minime de calcul sunt la -18 Či -24 gr.C
Mi-ar placea sa explicati intr-un alt clip cum funtioneaza pompa de caldura de tip geotermal, cu tot ceea ce tine de foraje, adancimi, tehnologie! Va multumesc
Buna ziua,
Foarte bine explicat. Temperatura de 25 grade tur in calorifere, mi se pare putin cam mica. Un minim de 35 este de dorit, sau calorifere dimensionate comparabil cu suprafata de transfer termic a IPAT.
Mi-ar placea un video in care sa se explice un bransament electric trifazat casnic, unde este asociat un sistem PV cu invertor trifazic simetric, prosumator, si unde consumatorii sunt asimetrici. De exemplu:
L1: import 10A
L2: export 10A
L3: export 10A
Nul de lucru calculat = 20A
In acest caz curentii nu se mai inchid intre faze ci vor suprasolicita nulul, care in normativul I7 valabil in Ro trebuie intrerupt alaturi de cele 3 faze la limita de proprietate printr-un disjunctor tetrapolar. Mai departe, acest exemplu inseamna ca nulul nu mai este dimensionat corespunzator. Ca si consumator trifazat, curentul pe nul poate fi cat maximul uneia dintre faze. Din exemplul de mai sus reiese ca curentul de pe nul poate fi dublul unei faze. Daca, in cazul unei avarii pe nul acesta nu se intrerupe, ci dezvolta o rezistenta, atunci 2 faze urca spre 400V si una coboara. Neexistand protecta adecvata, se pot produce multe pagube.
Pot oferi mai multe detalii daca e nevoie.
Noi avem un astfel de sistem. Export de 10A pe 2 faze si import de 10 pe alta faza nu prea ai cum sa ai. Pe perioada de iarna productia de energie electrica este mica la PV. Avem o pompa de caldura (aer-apa 24KW) care consuma din 3 faze cate maxim 3KW - 3KW si respectiv 6 KW daca temperatura exterioara este de sub -5 grade celsius (2 din 4 module nu pornesc daca temperatura de afara nu o necesita). In momentul acesta am consum 13.38A din faza A, 1.5A din faza B si 11.06A din faza C cu un consum total de aproximativ 5700W din retea si 1730W din PV. Ca sa importi 10A intre timp ce pe alta faza exporti 10A inseamna ca ai consumatori pe L1 de 20A toti monofazati ceea ce este cam nerealist doar daca instalatia este foarte prost facuta si toti consumatori monofazati mari au fost pusi pe aceasi faza. La noi avem 3 mari consumatori: pompa de caldura, cuptorul electric si plita cu inductie dar toti 3 sunt trifazati. Altceva ce poate consuma mult pe o faza ramane doar cuptorul cu microunde, prajitoare de maine si computer-ul (circa 600W maxim) deci cam greu sa ajungi la 4600W consum pe o singura faza constant.
@@alexandruilea915 Multumesc de reply si detalii. Cazul prezentat de mine este real si mai contine un ESS monofazic. Acesta poate crea asimetrii mari in cazul unor consumatori monofazici mari, pentru a compensa consumul acestora.
Experiment real la sistemul mentionat:
L1: export 11A
L2: import 18A
L3: 0
Masurat 26A pe N.
Disjunctorul general tetrapolar (obligatoriu I7 in Ro) a cedat, a dezvoltat o rezistenta pe nul, dar nu s-a intrerupt nulul. Pagube de 2000 eur. Asteptam solutionarea de la distributie. Iti recomand sa iti instalezi minim un releu de protectie cu asimetria fazelor inclusa. Exemplu ETI HRN 100.
@@alexandrupatru4 Noi cel putin momentan nu ne-am montat stocare pentru ca nu are sens. Vara consum din retea sub 150 kWh iar iarna nu produc cat consum deci nu-si are rostul. O sa discut cu electricianul cu care lucrez de releul de protectia.
Destul cÃĒt sa s0ga un kV/h,ei trebuie sa vÃĒndÄ acest produs la necunoscÄtori
â@@alexandruilea915 isi are rost stocarea daca e si hobby la mijloc 50%. Si restul treci tot pe electric + EV. Vorbeste cu electricianul pentru ca sa iti protejezi investitia.
Raportul de 1 la 5 kw depinde de modelul de pompa : apa-aer, apasol, apa-apa.
Da, este ideal sa existe o ÃŪncÄlzire prin podea. Merge Či cu radiatoare, dar supradimensionate, pentru ca temperaturile de lucru sunt mici 40-50C
40-50C
Corect, si la aer-apa temperatura din exterior conteaza foarte mult. Ca sa ridic temperatura apei de la 40 la 45 de grade celsius consum dublu fata de aceleasi 5 grade dar de la 30 la 35 de grade celsius. Din acest motiv am analizat si calculat bine situatia si am ajuns la concluzia ca cel mai bine este sa incalzesc toata casa mai mult (pana la 23-24 celsius) pe timp de zi cand temperatura exterioara este mai mare si sa trec termostatele pe 21.5 seara dupa ora 20. In acest fel doar aproximativ 20-25% din incalzire se face pe timp de noapte cand eficienta este mult mai mica. Spre exemplu noaptea trecuta au fost -4 grade celsius afara iar acum sunt 2 grade celsius. Eu dimineata la ora 7:30-8 opresc pompa de caldura si ii permit apei din instalatie (puffer) sa se raceasca sub 30 de grade celsius. In acest fel la ora 10-11 pe cand se incalzeste afara si randamentul meu creste am si un punct de plecare mai jos si o temperatura exterioara mai buna. Astfel cand pornesc pompa de caldura la ora 10 am COP de 4.2-4.5 in loc de 3 cat ar fi randamentul pe timp de noapte si practic incalzesc cu un consum total la nivel de zi mai mic. Este cam complicat si pretentios modul de utilizare dar eu lucrez de acasa si imi place sa "ma joc" cu ea. Aaa da, si toate calculele facute de mine sunt la o temperatura de 40 de grade celsius maxim. Daca vrei sa urci apa la 50 de grade celsius cu -5 grade celsius afara COP-ul se duce la 2 si deja esti la pret de incalzire pe gaze deci nu are sens. Ca sa aiba rost din punct de vedere costuri ai nevoie de: izolatie cat mai buna, incalzire in pardoseala (ca sa nu pui calorifere de 4 metri in living) si fotovoltaice montate pe un suport reglabil (ca unghi) orientate pe sud. Noi avem izoltie medie, incalzire in pardoseala si PV pe acoperis orientate E-V. O putere instalata de 20 KW de fotovoltaicele nu produc mai mult de 25 de kWh intr-o zi de Decembrie cu orientare E-V la unghi de acoperis normal (30-40 de grade, nu stiu exact cat este) pentru ca partea de vest este aproape moarta. Vara au produs bine cu multe zile peste 100 kWh si am avut productie de minim 2KW de dimineata pana la apus dar pe timp de iarna sufera mult din cauza acestei orientari. Puterea maxima este de 6KW obtinuta in principiu din cei 10 KW instalati pe est in prima parte a zilei (pana la ora 11:30).
Ca pun unitatea in garaj , unde temperatura este de 11 grade , nu consumÄ mai putin?
DacÄ montez unitatea in garaj?
@@mihaiplinge1140 Consumi mai putin pana cand in garaj o sa ai mai putin de -15 grade celsius. Fiind spatiu inchis ti se va termina sursa de caldura la un moment dat si avand perete comun cu casa o sa tragi caldura din casa.
"randamentul" poate fi si subunitar daca explodeaza :)
Foarte bune si utile explicatii ! Va multumim ! Sunt intr-adevar multe nelamuriri cu privire la aceasta tehnologie relativ noua aparuta pe piata. Asteptam cat mai multe astfel de video-uri legate de domeniul constructiilor si fizica.
Relativ noua adica incepand cu 1877. Cea instalata la primaria din Geneva posibil sa mai fie inca in functiune. Din 1928.
@@razvanlex Surprinzator, atunci relativ noua pe piata de larg consum pentru utilizatori casnici :)
@@vaidaandrei710 Nici macar, doar ca in general gazul era mult mai ieftin decat electricitatea si nici macar un SCOP 4 nu facea profitabila o pompa de caldura. 14 bani gaz cu 65 sau 70 de bani curent, centrala gaz era alegerea, acolo unde exista retea.
â@@razvanlex
Noi acuma am ajuns la nivelul lor din aceea vreme . Cu atÃĒt suntem rÄmas ÃŪn urmÄ .
@@sandorriza5202 Nu acesta este reperul. Noi am avut gaz ieftin fata de electricitate si ne indreptam iar inspre asta. 85 bani pe kWh electricitate la Hidroelectrica fata de 26 bani la Engie. Deci SCOP 3,26 ca sa iesi la acelasi pret cu gaz, ceea ce inseamna ca e greu de rfecuperat investitia. Daca nu exista acces gaz, cam asta ar fi alegerea, daca fondurile permit.
Ne dam seama cat de in urma suntem dupa numarul budelor din fundul curtii...
D-le Cristian, de ce trebuie sÄ ne scÄrpinÄm cu mÃĒna dreaptÄ ÃŪn urechea stÃĒngÄ ? Pompele de cÄldurÄ sunt f. scumpe Či
necesitÄ o instalaČie complicatÄ. Sunt adeptul centralelor termice pe gaz. Sunt SIMPLE Či eficiente dacÄ se respectÄ unele norme.
Am casÄ de 92 mÂē, f. bine izolatÄ termic,atÃĒt pereČii exteriori cÃĒt Či tavanele. Geamuri termopan Či cele 2 uČi exterioare cu
izolaČie prin interior. InstalaČia de ÃŪncÄlzire cu ČeavÄ de cupru Či calorifere supra-dimensionate. Centrala o am de 19 ani conectatÄ la un
stabilizator tensiune Či e comandatÄ de un termostat-ambient. Pe timp de iarnÄ temperatura ÃŪn casÄ am setat-o la 23°C ziua Či 21°C noaptea.
PÃĒnÄ sÄ se mai scumpeascÄ gazul, am plÄtit factura la gaz ÃŪncepÃĒnd cu 80 lei/lunÄ (cÃĒnd gazul a fost ieftin) Či cel mult 120 lei/lunÄ (cÄnd gazul
sa mai scumpit), pentru cÄldurÄ, apÄ caldÄ Či aragaz. Acum cÄ gazul s-a scumpit Či mai mult Či nu va mai fi subvenČionat, voi ÃŪnlocui
centrala clasicÄ cu una ÃŪn condensare, chiar dacÄ U.E. trÃĒmbiČeazÄ verzi Či uscate. Probabil ÃŪn viitorul nu prea ÃŪndepÄrtat cÃĒnd vom avea curent electric
ieftin, voi opta pentru o centralÄ electricÄ ÃŪn loc de pompÄ de cÄldurÄ, ca sÄ nu mai pÄlÄvrÄgeascÄ U.E. cÄ poluez.
Apropo, am reuČit sÄ gÄsesc pe internet pe un site american cÄ poluarea pe Terra cu dioxid de carbon (COâ)(CoDoi) este de 0,04%. Ãn cÃĒteva
decenii a crescut de la 0,03% la 0,04%. DacÄ dioxidul de carbon ar scÄdea sub 0,02% toate plantele ar muri. Ce vrea U.E., cÄ nu ÃŪnČeleg (?!)
Am uitat sÄ specific cÄ ÃŪn acel site, au fost ÃŪntrebati 3 âspecialiČtiâ ÃŪn domeniu, dacÄ Čtiu ce procent de Dioxid de Carbon existÄ ÃŪn atmosferÄ.
Unul a zis 5%, al doilea 7% iar al treilea 8%. Wooow ! SpecialiČti ?! PS: ConferinČa respectivÄ era despre poluarea mediului.
D-le Cristian ce procent de Dioxid de Carbon Či alte gaze credeČi cÄ exista ÃŪn atmosferÄ pe vremea cÃĒnd erau activi mii Či mii de
vulcani pe Terra Či de ce viaČa Či-a urmat cursul ?
Nu imi permit sa raspund in locul dl profesor dar va dau cateva cifre: Inainte de era industriala (1800) concentratia era de 280 ppm (0.028), in 1960 era 320 ppm(parti pe milion), acum este 420 ppm. Oricum ati calcula este o crestere cu 33% fata de normal si 25% din 1960. Numai in ultimii 10 de ani am crescut de la 400 la 420 ppm. Deci cresterea este in progresie geometrica. Ca dvs ati izolat extrem de bine casa si ca obtineti consumuri la jumatate decat am eu cu o centrala in condensatie la bloc, va felicit! Faceti parte din 0,01% din consumatorii de gaz. Nu inteleg ura asta pe care o exprimat fata de UE. Poate ati vazut si dvs ca iarna nu mai avem zapezi, anul asta "gerul bobotezii" a fost de 11 grade, vara temperaturile extreme, care acum cativa ani insumau cateva zile, se mentin saptamani/luni la rand. Si da, UE discuta de posibilitatea eliminarii centralelor pe gaz DUPA ANUL 2050. Pana atunci pompele de caldura vor deveni mai ieftine si mai eficiente, iar temperaturile din timpul iernii vor fi mult mai mari, caci doar nu o sa scada CODOIUL cu astfel de atitudine.
@@ibnabalotestimarketing1309 - Ca Či ÃŪn Parlamentul RomÃĒniei Či ÃŪn Parlamentul U.E., au âpopositâ fel
de fel de NEICA NIMENI trimiČi de partide Či voteazÄ la âindicÄČiileâ unor interese mafiote.
Domnul vb nu inseamnÄ cÄ are si perfectÄ dreptate. Vorbeste si el sÄ ia cÃĒČiva bÄnuČi!
92mp de casa incalzita cu 80-120ron ? probabil dvs. aveti centrala electrica iar gazul ce il platiti este doar pentru aragaz
Suuper prezentarea.
O ÃŪnghiontire colegialÄ, dacÄ-mi permiteČi.
Ãn jurul minutului 1:15 spuneČi cÄ _pompa de cÄldurÄ consumÄ 1 kWh pentru a transfera 5 kWh_, ceea ce e inexact faČÄ de ceea ce spuneČi la ÃŪnceput _o pompÄ de cÄldurÄ consumÄ 1 kWh Či produce 5 kWh_.
De fapt, ceea ce cred cÄ aČi dorit sÄ spuneČi Či ar fi fost mai exact, cel puČin teoretic, fÄrÄ a se lua ÃŪn calcul pierderile de cÄldurÄ, este cÄ pompa de cÄldurÄ, din 100% energie termicÄ pe care o produce, adicÄ 5 kWh, 4 kWh ÃŪi preia din mediul de energie de joasÄ temperaturÄ, folosind 1 kWh electric pentru acČionarea agregatului (compresor, actuator sursÄ etc.), kWh consumat care se regÄseČte ÃŪn energia termicÄ finalÄ produsÄ de pompa de cÄldurÄ.
AdicÄ ar fi trebuit sÄ spuneČi la 1:15 cÄ _pompa de cÄldurÄ consumÄ 1 kWh pentru a transfera 4 kWh_ din mediul de joasÄ temperaturÄ ÃŪn mediul de ÃŪncÄlzit.
Altfel, din ceea ce spuneČi la 1:15 ar reieČi cÄ, de fapt, avem un raport COP de 6, nu de 5 cum era pe valorile pe care le-aČi dat la ÃŪnceput.
AdicÄ, energia se conservÄ Či se transformÄ? Sau cuomo si dice in lingua fizica? ð
Oricum, sunt un super mare fan de-al dvs. E drept cÄ mÄ cam pierd ÃŪn partea de fizicÄ cunaticÄ, dar noroc cÄ pot relua videoclipurile dvs. de popularizare Či mÄ mai edific.
FelicitÄri Či mulČumiri pentru faptul cÄ aduceČi fizica avansatÄ Či ČtiinČa mai aproape de noi oamenii de rÃĒnd. ðĪðĪðĪ
CrÄciun fericit!
Multumesc pentru expunere pe intelesul tuturor.As dori daca se poate o explicatie despre instalarea unei pompe de cÄldurÄ de tip sol-aer.(la ce adancime se ingroapa tevile de circulare a agentului )Casa este in constructie si daca este santier as dori sa le bag in pamant acum.Multumesc.
@@petrunegrei1226VÄ recomand sÄ luaČi legÄtura direct cu un montator de pompe de cÄldurÄ sol-apÄ. Chiar dacÄ adÃĒncimea s-ar putea sÄ nu difere mult de la un producÄtor la altul, numÄrul Či lungimea circuitelor s-ar putea sÄ difere drastic.
Nu le faceČi cu informaČii preluate de aici. FaceČi-le cu cineva care ia lucrarea Či, cel mai important, rÄspunde pentru ceea ce vÄ consiliazÄ Či vÄ implementeazÄ. Asta ca sÄ nu lucraČi de douÄ ori.
Presupun cÄ vÄ referiČi la colectorii de antigel din polietilenÄ. SÄ ČtiČi cÄ mai este o tehnicÄ puČin mai eficientÄ: vaporizarea directÄ ÃŪn sol.
Mult succes!
Mi-ar placea sa faveti un Videoclip unde sa explicati cum functioneaza incalzirea prin panouri cu infrarosu.
aici cred ca e mai simplu. Mi-am cumparat si eu unul, ca sa constant ca de fapt incalzeste cam tot prin convectie, partea cu infrarosu e mult mai putin decat asteptam. Dar ma rog, mi-am luat cel mai ieftin panou, era sub 100 de euro.
ððð
Thanks
Multumim pentru sustinere
+conditiile de minim de temperatura exterioara+investitia initiala+service-ul regulat+alte de chestii de genul...pai stai domne' ca ai inteles gresit ca poti renunta definitiv la sursele clasice de incalzire! Sunt lucruri interesante insa trebuie prezentate cu semnul "nu este recomandat celor cu salariu mediu pe economie" :)
In functie de modelul ales costurile difera, cred ca cea mai rentabil este o pompa apa-sol care nu depinde atat de mult de temperatura exterioara. Avem incepand de anul acesta o pompa aer-apa si este decenta dar sensibila la temperaturile exterioare. Am adaugat-o ca si sistem hibrid pentru incalzirea pe lemne (gaze nu exista in localitate) dar pana acum nu a fost necesar sa pornim cazanul cu lemne.
AČi reusit sÄ mÄ lÄmuriČi ÃŪn 10 min , ce nu au reusit profesorii de termodinamicÄ , 4 ani de facultate ðĪĢð
daca nu prea ai fost 4 ani la faculta.(
In elisodul urmator poate explirati modul in care umiditatea aerului afecteaza eficienta aparatului. Locuiesc intr-o vale unde umiditatea medie este de 70-80%.
Afecteaza oare pozitiv acest aspect fiind mai dens aerul sau negativ crescand conductivitatea termica a aerului?
De asemenea pompele de caldura geotermale ( cu tevi prin pamant la 1m adancime) sunt remarcabil mai eficiente decat cele aer-apa?
Ceea ce omiteČi e ca un astfel de sistem are randament atÃĒt timp cat afarÄ nu sunt temperaturi extrem de scÄzute. De exemplu cand vreau sa folosesc sistemul sa imi incalzesc locuinČa instalatia din exterior se va rÄcii puternic (ex -20 de grade) si va folosii "cÄldura" de afarÄ ( ex 5 grade ) sa ÃŪncÄlzeascÄ radiatorul extern. Aceasta diferenČa este transferatÄ prin schimbarea de presiunii a gazului din interior si transformatÄ in cÄldurÄ. Este interesant sistemul doar ca nu trebuie prezentat ca supra-randament peste 100%. Cel mai mare minus ar fi ca pompele se strica cand lucreazÄ din greu cu gerul de afarÄ care este apropiat de temperatura radiatorul extern.
Cand vom face episodul urmator despre acest subiect vom atinge si aceste aspecte.
@@presura MulČumesc pentru ÃŪnČelegere. Cred ca este foarte important sa se cunoascÄ atÃĒt avantajele cat si dezavantaje ideilor astfel ÃŪncÃĒt sa putem lua decizia corectÄ avand in vedere circumstanČele. Per total cred ca este un video reuČit si sper sa vad cÃĒt mai mult conČinut de calitate din partea dumneavoastrÄ. Mult respect ðŦĄðŧ
D-le Presura, mi-as dori sa explicati ce se intampla cu caldura inmagazinata de freonul care iese din condensator, in acea valva de expansiune. Nu este/poate fi utilizata?
Magia din ce se intampla aici si in orice frigider/AC ar fi trebuit totusi explicata la minutul 5:40, efectul capilar. Freonul care vine de la compresor cu temperatura si presiune mare va fi fortat sa treaca printr-un tub foarte subtire, ce va duce la o scadere puternica a presiunii. Cum stim de la fizica din generala, PV=nRT si relatia dintre presiune si punctul de fierbere al unui lichid/gaz (apa fierbe la 78 grade pe Everest, la presiune joasa). Freonului ii va scadea puternic si temperatura de fierbere, acesta se va evapora, fenomen care se face cu cedare de energie din partea freonului, si cauzeaza implicit racirea freonului.
Prin analogie, aerul de afara este mancarea din frigider (ambele incalzesc freonul), iar radiatorul din spatele frigiderului devine caloriferul nostru, care degaja caldura din sistem (racesc freonul)
Din pacate nu sunt rentabile la pretul actual al gazului in Romania in alte tari din vestul Europei posibil sa fie sau daca nu ai acces la instalatie de gaz ci doar la curent. Vorbim de o investitie initiala de 1000 de euro intr-o centrala pe gaz vs cateva mii in pompa plus incalzirea in pardoseala. Apoi vine costul lunar mc vs kwh chiar daca ai panouri solare cum am eu si tot nu iti alimenteaza toata ziua ci maxim 2-3 ore in perioada de iarna. Parerea mea e ca nu iti poti recupera investitia nici macar in 20 de ani decat daca primesti o subventie de la stat asa cum este casa verde. Poate urmatoarea generatie de pompe va fi si mai eficienta. Fac calcule de cel putin 7-8 ani dar nu ma conving sa fac schimbarea.
Pentru o pompa de caldura casa trebuie sa fie gandita dinainte altfel nu prea se justifica investitia cum spui si tu. Fara incalzire in pardoseala este un cost mare pe care nu merita sa-l iei daca ai acces la gaze. Investesti prima data intr-o izolatie cat mai buna + incalzire in pardoseala si doar apoi te gandesti la pompe de caldura.
As vrea sa adaug cateva lucruri la acest video. In primul rand nicio pompa de caldura aer-apa nu are un randament de 1 la 5. Randamentul este in jur de 1 la 3. La minus 5 grade pompa nu mai este eficienta. Pt calorifere temperatura apei pe tur trebuie sa aiba minim 50-55° C
cred ca depinde de situatie si de pompa. Eu am gasit exemple care mergeau peste 4 si pretindeau ca ajung la 5 in situatiile favorabile. Am ales 5 pentru puterea de impact, e car ca daca afara este sub 0 grade coeficientul de eficienta va fi mai mic. Asta voi discuta data viitoare, acum am vrut sa zic doar principiul
Domnul Cristian cum putem influenta cantitatea de gheata care se formeaza pe unitatea exterioara?
Plus o explicatie a conditiilor in care se formeaza aceasta gheata.
Va mulČumesc pentru explicaČiile pe ÃŪnČelesul tuturor,deci Či al meu. Aud ÃŪn ultima vreme de o combinaČie, pentru ÃŪncÄlzire,avÃĒnd la bazÄ curentul electric produs de panourile fotovoltaice. Ce ziceČi, are randament bun un astfel de sistem?
Ce conteaza in ce fel obtineti energia electrica? Nu depinde randamentul termic al sistemului de provenienta energiei. In plus, energia din panouri o veti putea folosi non-stop doar daca va puneti si sisteme de stocare a energiei. Daca nu aveti sisteme de stocare si luati din retea energie noaptea tot acelasi randament o sa aiba pompa. Daca va referiti la costuri, cum iesiti mai ieftin, conteaza prea multe variabile ca sa va spuna cineva cum e mai ieftin. Generic vorbind, cel mai profitabil e sa minimizati pierderile prin a va izola casa, de abia apoi sa obtineti caldura consumand cat mai putina energie (pompa de caldura) apoi sa faceti rost de energie cat mai ieftina (fotovoltaica) si sa limitati consumul inutil in general (electrocasnice cu clasa energetica A, etc). Mai sunt si alte optimizari care se pot face dar unele presupun investitii mai mari, altele inseamna modificari ale stilului de viata si lumea se simte atacata daca vorbesti de ele asa ca nu le mai zic...
Avem pompa aer-apa si fotovoltaice 20KW instalate. Luna aceasta am produs 261 kWh din PV si am consumat 1500 kWh cu incalzirea + alte cele prin casa. Randamentul pe PV este mic pe timp de iarna iar vara nu ai nevoie de atata energie electrica. Noi fiind prosumatori compensam cantitatea de energie vara cu iarna dar platim oricum transportul care costa aproape dublu cat energia in sine deci per total imi ramane si de plata la final de luna. Ii drept ca ale noastre fotovoltaice sunt pe acoperis E-V si s-ar putea optimiza daca ar fi toate pe SUD si ai folosi pompa pentru a incalzi in principiu atunci cand este soarele sus pe cer (cam rar in Decembrie). Pentru noi este ok pentru ca eu lucrez de acasa si jonglez cu ele in fiecare zi dar pentru cineva care vrea sa o instalezi si sa uite de ea nu prea merita bataia de cap. Cum zicea si Silvia, prima data izolatia cat mai buna si doar apoi vedeti de schimbarea sistemului de incalzire. O casa care consuma mult gaz/lemne va consuma multa energie electrica cu o pompa de caldura. De baterii nu are rost sa discutam deoarece costa mult si productia pe timp de iarna nu este suficienta nici pentru pompa de caldura aer-apa singura deci nu are rost discutia. O pompa de caldura apa-sol cu un sistem PV de 10 KW orientate toate pe sud la sol cu unghi reglabil (iarna un unghi de 60-70 de grade are randament maxim iar vara vrei un unghi de 25-35 pentru randament maxim), baterii si izolatie foarte buna poate face ca costurile lunare sa fie minime spre 0 dar sincer va spun, la cat costa toata investitia mai bine ne cumparam o casa de vacanta in Grecia unde si acum sunt minim 18 grade celsius si ne mutam sezonieri ca si pasarile.
@@silviadumitrescu7509m-am referit strict la randamentul unui sistem compus din pompÄ, panouri fotovoltaice, baterii de stocare.
âĪâĪðð
Buna ziua. Nu stiu daca ati tratat acest aspect in alt video, asa ca am zis sa scriu aici: nu inteleg de ce este nevoie ca freonul sa fie racit "artificial". Nu ar fi mai eficient sa fie dus direct catre compresor la temperatura din casa? Astfel, compresorul ar consuma mai putina energie pentru a comprima si a incalzi gazul. Multumesc.
ððð
E o idee bunÄ ca unitatea externÄ a unei pompe de cÄldurÄ aer-apa (folosita exclusiv pentru ÃŪncÄlzire) sÄ fie montata ÃŪntr-o serÄ (170m3)? Ar trebui sa creascÄ semnificativ eficienČa iarna...
Multumim pentru informatii! Am incercat sa caut printre comentarii daca a pus cineva problema dezavantajelor/impactului acestor pompe, dar nu am gasit.
Ce m-ar interesa pe mine:
1. Exista dezavantaje pentru pompele de caldura? ( Ma refer la o locuinta unde pompa de caldura ar functiona optim).
2. Ce impact au pompele de caldura asupra mediului? Dupa cum am invatat la fizica/chimie, in natura nimic nu se pierde, nimic nu se castiga ci totul se transforma asa ca undeva trebuie sa se disipeze energia aceea.
Acum 11 ani am participat la o prezentare a acestor pompe de caldura (daca nu ma insel a celor de la Rehau) si am fost informati ca mediul inconjurator este afectat, in special in cazul pompelor care au circuitul ingropat in pamant (sol/aer, sol/apa). Modificandu-se temperatura solului, plantele sunt afectate. Este vreun studiu pe termen lung sau macar vreo simulare pe calculator cu impactul pompelor?
Am zice ca atat solul cat si atmosfera au un volum urias, dar daca toata suflarea ar folosi aceste pompe, as zice ca impactul ar fii urias. Pamantul din jurul locuintei ar ramane inghetat pana in Mai, sau ar fii foarte cald pana in Decembrie (daca folosim pentru racire)
M ar interesa mai multe detalii despre electroliza in centralele termice de casa si cum ar putea fi eliminata. Am citit ca ar exista o varianta cu sudura prin explozie..
Pompele sunt evaluate la condiČii ideale de funcČionare. Cu cÃŪt temperatura exterioarÄ scade pompa va folosi rezistenČa electricÄ din "dotare" sa compenseze pierderea coeficientului COP. EficienČa acestei "instalatii" pe timp de iarnÄ se apropie de cea a unei centrale termice pe curent. Ãntr-adevÄr s-ar putea sa aiba o eficienČÄ energeticÄ pozitivÄ asociatÄ cu un sistem fotovoltaic de 4-5kW.
PinÄ ne vor permite Huuu U.E sa ne exploatÄm resursele de gaze naturale ce-a mai ieftinÄ (nu eficienta) variantÄ de sistem de ÃŪncÄlzire rÄmÃŪne cea pe gaze naturale.
BunÄ ziua.Domnu Cristian cu o informaČie mÄ puteČi ajuta.Se poate realiza sistem free Energy cum au reuČit ce-i de la Infinity Sav generator magneČi permanenČi.
Chiar este magie.
Din cate am ÃŪnteles, este asemanator cu un aier conditionat. Stiu cala aier conditionat la nu stiu cat timp trebuie sa pui freon. La fel este si la pompele de caldura? Unde dispare freonul?
Functionarea pompei , ca si a frigiderelor si instalatiilor de aer conditionat , se bazeaza pe schimbarea de stare a freonului din lichid in gaz si invers , procese ce au loc cu absorbtie si cedare de energie ( caldura ) . Instalatorii , care nu au fost pe la scoala , vorbesc de randament supraunitar , ceea ce e o eroare , pentru ca nu e un sistem inchis . E ca si cum am spune ca o sonda de petrol are randament de 1000% iar una de gaz de 10000... % . Cea mai simpla pompa de caldura e o instalatie de aer conditionat , daca nu deranjeaza curentul de aer si nu trebuie apa calda menajera .
Foarte bine spus, eu am pompa de caldura si sub 0° Celsius randamentul este sub 1/1 ð , intr-o iarna geroasa de Romania trebuie sa mai pun bani de la mine !
@@ionutlupu2762 Ar trebui sa se intample asta la temperaturi mai mici de -15 grade Celsius , dar nu am pompa ca sa fiu sigur . Asa , randament de aproape 100% se obtine cu un simplu radiator electric cu termostat .
Cu tot respectul .... asta e un subiect de vanzator de pompe de caldura.... nivelul dvs stiintific sunt sigur ca este mult mai mare ... asta e un videoclip de promovare ?
Nu este un video de promovare, este un video de poularizare si daca la inceput orice tehnologie este privita cu reticenta asta nu inseamna ca nu o putem populariza.
Daca este posibil, va rog sa detaliati care este diferenta dintre o pompa de caldura si un apart de ser conditionat.multumesc!
Aparatele de aer condiČionat sunt de fapt niste pompe de cÄldurÄ aer-aer
Corect, si ar mai fi de adaugat ca majoritatea sunt facute sa functioneze pana la o temperatura de minim -5 grade celsius. Sub aceasta temperatura aparetele de aer conditionat nu mai functioneaza pentru ca sunt gandite in primul rand pentru frig. Pot si incalzire in perioada de toamna/primavara dar in Decembrie la -10 sau mai jos fie au COP 1 fie nu pornesc deloc.
Interesant ca am atins subiectul acesta . Eu sunt atat de mandru de mine... ððð. Varianta pe scurt este ca am o pompa de caldura de 12kw si mi-a trebuit 1 an sa o optimizez la necesarul meu si la conditiile mele . Am intampinat o sumedenie de probleme, de la debit insuficient in putul de absorbtie (apa-apa) la fructuatii de tensiune care o trimiteau in protectie pe care a trebuit sa le diger singur si sa caut solutii . Oamenii din jurul meu ori erau depÄČiČi de situaČie ori ambele lolð ÃŪmi recomandau cazan pe lemne , sa schimb produsul cu al altui furnizor etc etc etc. Pot sa confirm ca o temperatura de cca 37° in apa din puffer imi da o temperatura confortabila de 22-23° in aerul din casa cu un consum minim de resurse . Ideea este sa gÃĒndeČti bine de la ÃŪnceput pierderile de cÄldurÄ ( izolaČie) suprafaČa mare in contact cu agentul termic ( multa ČeavÄ in pardoseala) Či cÃĒt mai mult control automat asupra ÃŪntregului proces ( termometre care controleazÄ circuitele) .
MÃĒndria mea vine din faptul cÄ am reuČit din postura de Čofer de camion sÄ ÃŪnČeleg ce este nevoie Či unde iar acum in sezonul acesta am apÄsat 1 buton in octombrie, mÄ aČtept sÄ apas acelaČi buton ÃŪn aprilie si voilà !! ð .... nu mÄ culc cu grija ca se termina lemnul in cazan, cÄ urca termeratura agentului termic peste limite , cÄ se rÄceČte casa , cÄ se scumpeČte gazul sau cÄ ia guvernul subvenČia la energie ....am aproape 200mp ÃŪncÄlziČi cu un minim de energie electricÄ consumata la un preČ mic ( hidroelectrica ð ð ð ) Či cu nici un efort din partea alor mei de ÃŪntreČinere . MÄ mai duc eu rar sÄ mÄ uit pe la manometre , termometre dar foarte rar .
Cam atÃĒt despre laude Či orgolii atinse , aČ vrea sÄ vÄd ÃŪn episodul urmÄtor o dezvoltare pe larg a cat de important este ca freonul sa fie dus la temperaturi negative Či dacÄ nu ar fi mai eficient un bypass ceva pe acolo ....
Ãn capul meu de 'Čofer de tir' nu prea se leagÄ nevoia de a duce freonul la -18° de la cca 40 cat are in schimbÄtorul de cÄldurÄ doar sÄ ÃŪl duci apoi la -5 cu alt schimbÄtor de cÄldurÄ Či sÄ ÃŪl reintroduci in circuit prin compresor ð ð sunt sigur cÄ sunt motive foarte bune pe care as vrea sa le aud explicate in acelaČi limbaj ca Či pÃĒnÄ acum de d-l Presura ....
MulČumesc
Freonul cu cat este mai rece pe iesire cu atat va fi mai eficienta pompa de caldura dar ca sa fie rece pe iesire iti trebuie un puffer intermediar si o a doua pompa de caldura. Cea care merge in exterior sa tina pufferul intermediar la 20 de grade celsius (eficienta maxima), iar cea care face efectiv apa caldura pentru casa sa schimbe doar intre 40 (in instalatia casei) si 15-20 in pufferul intermediar ca sa obti randamentul maxim dar nu cred ca se justifica complexitatea si banii in plus pentru castigul de eficienta.
De ce nu spui concret cÃĒt curent consumÄ la 24 de ore de funcČionare?
@@haiugeorgel depinde de tipul de pompa, gradul de izolatie al casei Či suprafaČa total ÃŪncÄlzitÄ. Noi avem o pompa aer-apa de 24KW (putere termicÄ declaratÄ) de la termocasa. Incalzim o casÄ izolatÄ mediu cu suprafaČÄ totalÄ utilÄ de 360 m2. Consum mediu pe luna decembrie undeva la 75kWh pe zi. O pompa apa-sol este mult mai economicÄ pentru cÄ aduce cÄldura din pÄmÃĒnt unde temperatura este constantÄ Či are mereu peste 10 grade Celsius. Modelul aer-apa pe care il avem noi consumÄ ÃŪn funcČie de temperatura de afarÄ. Consumul maxim pe ora este de circa 12.5 kWh dacÄ ruleazÄ la capacitate maximÄ deČi cam rar a fost nevoie de ea sÄ meargÄ la capacitate maximÄ deocamdatÄ pentru noi. Indiferent ca consumi 12 kW pentru 4 ore sau 6 kW pentru 8 ore consumul total este acelaČi Či este dat de necesarul de cÄldurÄ al casei.
Felicitari pentru ca ai trecut la pasul sa testezi si sa-ti optimizezi consumul. Ca intelegi sau nu exact ce se intampla la nivel micro e mai putin important, si desigur cifrele din video sunt niste exemple academice nu ce se intampla la orice pompa de caldura in realitate. Eu ca sa inteleg ma gandesc la conservarea energiei. Ca sa dau caldura in camera trebuie sa iau de undeva caldura (de afara). Cu cat e mai mare temperatura de afara fata de freonul scos din valva cu atat freonul absoarbe mai multa caldura de afara, deci trebuie sa am freonul cat mai rece cu putinta.
@@silviadumitrescu7509 in contexul asta, ce parere aveČi de idea de a combina 2 pompe de cÄldurÄ? Aer-apa pentru o temperaturÄ de 20 celsius ÃŪntr-un puffer Či de acolo la 40-45 cu o pompÄ apa-apa?
ðððžððžððžððž
Ce ne mai dorim: comparatie intre tipurile de pompe de caldura. Si o intrebare de curiozitate: daca afara sunt -18 grade si freonul este racit la -18 grade inseamna ca freonul nu va putea fi "incalzit" cu aerul de afara pentru ca practic diferenta de temperatura este 0, deci practic nu mai putem incalzi freonul? In acest scenariu singura metoda de a mai incalzi freonul este prin aportul compresorului, nu? In acest caz, cat ar mai fi (ipotetic) eficienta pompei?
Pompele de caldura sunt dotate si cu o rezistenta electrice ce intra in functiune in scenariul de temperatura mai scazuta de -15 grade celsius
VÄ salut ,eu am o ÃŪntrebare ,de ce nu punem in miČcare motoarele termice alimente cu hidrogen,nu cu cel stocat , Či cred cÄ ČtiČi bine despre ce vb?
Schema este greČitÄ...pentru eficienta maxima fluxurile trebuie sa fie in contracurent, mai ales ÃŪn condensator....adicÄ freonul cu temperatura mare intra pe sus unde temperatura aceste cea mai mare Či iese pe jos, unde temperatura este cea mai mica pt cÄ apa se ÃŪntoarce din calorifer, la fel Či cÃĒnd iese din casa in evaporator intra pe jos se ÃŪncÄlzeČte Či iese pe sus...evaporatorul Či condensatorul sunt 2 utilaje de transfer termic deci pe bilanČul termic trebuie sa ai un capÄt cald Či unul rece iar pentru asta fluxurile trebuiesc puse ÃŪn contracurent...
Ciclul frigorific este caracterizat prin faptul cÄ temperatura de vaporizare , este egalÄ cu temperatura mediului rÄcit Tr (mediul de afara), astfel cÄ Tv = Tr = T0. Temperatura de condensare Tk este egalÄ cu temperatura mediului ambiant Ta, deci Tk = Ta. Deci intre 2-3 procesele si schimburile au loc in partea din casa iar 4-1 procesul si schimbul are loc intre agentul frigorific si mediul rece de afara .
Coeficientul de performanÅĢÄ sau eficienÅĢa frigorificÄ a ciclului frigorific este definit prin raportul dintre efectul util al ciclului (puterea frigorificÄ specificÄ) Åi lucrul mecanic total consumat:
COP , asa cum este denumit coeficientul de performanta instantaneu este si el mai mare cu cat diferenta intre temperatura mediului ambiant si temperatura mediului rece este mai mica . Asa putem obtine performante chiar de 6kw termici la 1 kw electric.
Lucrul mecanic minim, necesar funcÅĢionÄrii unui ciclu frigorific, cel mai eficient din punct de vedere al consumului de lucru mecanic este cel consumat ÃŪntrun ciclu Carnot reversibil inversat, iar mÄrimea acestuia se poate calcula cu relaÅĢia: q= ((ta/tr)-1)qo
Din analiza relaÅĢiilor de mai sus se observÄ cÄ la aceeaÅi temperaturÄ Ta a mediului ambiant (sursa caldÄ), cu cÃĒt scade temperatura Tr a mediului rÄcit, cu atÃĒt creÅte lucrul mecanic necesar ciclului Carnot inversat Åi scade eficienÅĢa Îĩf a ciclului, deci aparent un ciclu frigorific este cu atÃĒt mai eficient cu cÃĒt temperatura mediului rÄcit este mai apropiatÄ de temperatura mediului ambiant, dar ÃŪn aceste condiÅĢii Åi efectul util produs de ciclul frigorific, este minim. Trebuie menÅĢionat cÄ eficienÅĢa frigorificÄ, aÅa cum a fost definitÄ, nu ÅĢine seama de calitatea frigului produs adicÄ de valoarea temperaturii la care se absoarbe cÄldura.
Teoretic. Practic nu se ÃŪntÃĒmplÄ asa. Practic ai 1-1 pt ca la noi e extrem de frig
ai pompa de caldura pe balcon? sau in apartament la bloc
Si centralele pe gaz se pot seta sa functioneze cu 27 - 30C pe tur cu incalzire radianta ( pardosea , pereti ) .
poti sa ne povesti mai mult de valva aia de expansiune.
Poate si de COP maxim teoretic (aČa cum e ciclul Carnot la motoarele cu combustie)
cand vom face episodul urmator despre acest subiect vom discuta despre aceste aspecte.
âĪ
SÄ fie mai multÄ claritate: freonul nu este un gaz specific, este o categorie de gaze, numitÄ freoni, Či sunt bazate pe carbon, hidrogen, clor Či fluor.
De ce este nevoie sa raceasca la -18 grade prin valva de expansiune? De ce poate sa ramana la cele 5 grade?
Ceva nu inteleg. Daca din un kw obtii 4 daca le-am folisi in cascadÄ cat am obČine ( un perpetuum mobile?)
Formularea este aiurea (marketing)....daca o sa te uiti si prin comentarii si prin alte documentatii defat cu 1KW muti 4-5kw de afara in casa....
Condensor Či vaporizator aČa este corect pentru o instalaČie frigorificÄ, condensator Či evaporator sunt traducerile obiČnuite
se zice ca daca ti-e frig freaca-ti mainile . eu folosesc lemne, insa daca nu as folosi e o metoda mecanica. un scripete de fonta si o sarma de 10sau 8,aceasta e curbata dupa scripete si incordata cu un arc de bok de bicileta. intr-o oala cu apa introduci axul cu scripetele si sarma .la rotatia unei eoliene ,sau daca pompele de caldura au doua motoare poti gandii ce temperatutra in apa poti avea, chiar depasind suta!
15 mii o pompa aer-apa de calitate medie (optimist spus medie) pentru suprafete mici, la care se adauga montaj. Sa zicem 20 de mii total (optimist). Pentru mine, ar fi undeva la 25 de mii o pompa aer-apa, la 120mp.
Acum, eu locuiesc intr-o zona de munte, iarna ajung si la -20 (maxim 2 saptamani pe an) dar in medie pot spune undeva la -5. Platesc in jur de 600 de lei, media lunara pe noi-mar(5luni). Asta inseamna 3000 pe iarna (lunile mai geroase, ca daca le iau si pe celelalte, pretul mediu platit scade mult). Total, in 2023 am platit 3900(decembrie inclusiv) asta inseamna aproximativ 7 ani pentru acei 25 de mii necesari pentru pompa de caldura. La acesti 7 ani se adauga consumul de curent al pompei in cei 7 ani, si cel mai important, diferenta de randament datorita temperaturii aerului mici fata de acel raport de 1:5 in cazul ideal, cu temperaturi peste 5grade. Altfel spus, in functie de model, raportul meu poate e de 1:2 si asta exact atunci cand am nevoie mai mare de caldura. Adica, probabil amortizarea se face in 15 ani, groso mondo. 8-10 ani garantie, inseamna ca probabil voi plati interventii la sistem, care ma vor costa in plus si vor mari perioada de amortizare.
Cu fonduri proprii, pentru populatia de rand a romaniei, nu se justifica instalarea unei pompe de caldura. Daca statul ar subventiona marea parte a cheltuielilor, se merita, altfel, poate nici nu apuci sa scoti banii bagati.
Ca sa nu mai vorbim ca una e sa dai 3-4 mii pe an, timp de 7 ani, si alta sa scoti 25-30 de mii de lei dintr-o data.
Ps: pompa aer-apa cu raport de 1:5 e un vis. Nu cred ca exista modele cu asa cop. Mai ales in conditii reale, mai degraba 1:2, 1:3
Či uite ca s a dus " magia " ca legile fizice pot fi ÃŪncÄlcate ððð 1 la 0 pentru fizicaâĪâĪâĪ. Eu cel puČin la cÃĒt am citit as recomanda tipul de pompa de cÄldurÄ cu panouri termodinamica. Mai rare dar " suna " interesant ðððð
GRESIT totuleste fizica .
Pai NU sunt incalcate, o pompa de caldura TRANSFERA caldura. Iarna de la exterior la interior pentru incalzire, vara de la interior la exterior pentru racire. Asta face frigiderul, "muta" caldura din interior la exterior, in bucatarie.
'INFRAROTHEIZUNG' 3 panouri electrice infrarosii(calorifere) 300W cost cca.300⎠decÃĒt uzine scumpe care nu-si pot demonstra eficienČa
Nu ÃŪnČeleg de ce freonul trebuie rÄciČi din nou la -18 grade. Nu ar fi mai eficient sa-l scoatem din casÄ la +18 grade? MulČumesc
Daca urmaresti in comentarii, am raspuns la aceasta intrebare.
Trebuie sa stiti ca atunci cand e ger afara,pompa de caldura nu mai face fata,si va trebuie o sursa secundara de incalzire.Eu traiesc cu pompa in casa de 20 de ani,dar pe langa ea am si incalzire electrica.Partea proasta e ca casa mea e rau izolata.
Buna ziua! Mi-ar placea sa ne explicati schimbul termic la trecerea din stare lichida in gazoasa si invers a freonului, ca nu imi este deloc intuitiv. imi imaginez ca are de-a face cu aglomeratia moleculelor si cat de repede se misca in functie de spatiul pe care il ocupa, dar ma contrazic circular de fiecare data cand incerc sa imi explic.
da, voi explica asta, in fond este fizica de baza, sa vezi molecula cu molecula. In special la racirea freonului prin expansiune, nu e imediat intuitiv, privind moleculele, ca temperatura trebuie sa scada, adica de ce sa scada viteza lor medie? Voi aborda problem,a
ok bun, un kwh pentru 5 kwh cÄldurÄ dar problema e aČa care e consumul la 24 de ore? Ce avantaj faČÄ de lemne sau gas? Miroase a prostealÄ asta cred eu.....
Daca tot ati ajuns aici, as vrea sa tratati si subiectul centrale clasice vs centrale in condensatie, care este mai eficienta, cum si cand ar trebui folosite fiecare dintre ele etc.
Cele ÃŪn condensatie au un randament mai ridicat. Temperatura gazelor de ardere la cos este ÃŪn jurul a 50-55 gr.C, faČÄ de una clasicÄ care are undeva la 135 gr.C.
Centrala in condensatie va economisi gaz(pana la 35%),doar daca exista incalzire in pardoseala,sau radiatoare supradimensionate,e similar cu a detine un bolid care poate atinge 300 km/h ,dar nu ai decat drum pietruit.Ca fiabilitate,cele clasice au fost net superioare.
@@haribo245 Exact! Asa stiam si eu, asa mi s-a confirmat dupa ce mi-am instalat centrala in condensare, si asta as vrea sa aud daca e cazul si de la domnul Presura!
â@@haribo245 Corect! BunÄ comparaČie!
@@durdu782 temperatura pe retur trebuie sa fie mica pentru ca sa aiba sens o centrala in condensare. Tu poti sa o faci mai eficienta si setant temperatura pe tur mai jos de 45-50 de grade celsius dar s-ar putea sa ai surpriza ca nu face fata la incalzire si sa functioneze non-stop. Acelasi lucru este valabil si la o pompa de caldura daca vrei sa o folosesti doar pe calorifere clasice care au fost gandite pentru agent termic la 55-60 de grade celsius minim.
Am si eu o ÃNTREBARE: Daca o pompa de caldura consuma 1KWh energie electricÄ pentru a aduce intr-o incintÄ 5KWh energie termicÄ din mediul ÃŪnconjurator, atunci de ce nu facem cumva sa trasformÄm 1sau 2 KWh din cei 5KWh energie termicÄ ÃŪn 1KWh energie electricÄ pentru a alimenta pompa de caldurÄ? Astfel am crea un sistem care aduce ÃŪn incintÄ un aport de energie din mediul inconjurÄtor fÄrÄ a mai consuma altÄ energie Či nu am mai incalzi planeta atat de mult. Ar fi posibil?
Pompele prezentate in clip (in scop demonstrativ) sunt cu adevarat zgomotoase, fiind pompe de generatie veche fabricate in USA, cel mai probabil Carrier.
Pompele Viessmann, Vaillant, LG si Daikin sunt asa cum ati prezentat dvs - silentioase si eficiente.
A mea este un Panasonic de ultima generaČie. Mi-aČ putea pune patul Či sÄ dorm chiar lÃĒngÄ ea, fiindcÄ nu m-ar deranja deloc.
maica-mea tocmai si-ia instalat la ea o pompa. Cum sta acasa, pompa e afara pe peretele din camera ei, si nu aude nimic,
Pompa si sistemul nu sunt chiar ieftine, dar investitia revine dupa cativa ani, in functie de suprafata spatiului incalzit.
am luat si noi de pe storyblock pe unde avem abonament. Pe de alta parte, daca puneam firme specifice, ne trezeam si cu reclamatia ca le facem reclama. Nici nu stii cum e mai bine...
Nimic nu se pierde ,nimic nu se castiga!!!
Totul se transforma!!!
da
Ca tehnologie e marfÄ,. umple buzunarele celor care le fabricÄ inclusiv samsarilor de energie romÃĒni si strÄini, ÃŪnsÄ ÃŪntrebarea mea este in cÃĒte secole amortizezi investiČia asta? 1 kw in RomÃĒnia este un leu, dacÄ depÄČeČti plafonul stabilit il plÄteČti ca la biČniČÄ, dacÄ pui panouri sÄ-Či asigure curentul fÄrÄ sa iei din reČea, nu ai rinichi in toatÄ familia sÄ vinzi sa faci banii necesari pentru instalare. Vise deČarte.
La cat ajunge factura la curent pt un apartament de 100 mp?
As adaugat doar un mic comentariu la aceasta explicatie. Caloriferul normal nu se folosete, de regula, impreuna cu pompa de caldura, deoarece are o suprafata mult prea mica de schimb de caldura. Prin urmare, pompele de caldura se folosesc adesea cu ventiloconvectoare sau prin pardoseala.
Nu tocmai adevarat, depinde de dimensiunea caloriferelor fata de necesarul de caldura al casei. Incalzesc casa de 135 mp la 24°C interior cu pompa de caldura de 6 kW si calorifere avand apa la 30-34°C in functie de temperatura de afara.
Či eu am pompÄ aer apa de 16kw Či ÃŪncÄlzesc 140 de mp cu calorifere la 24 de grade , apa ÃŪn pufar sta la 55 de grade pe timpul iernii. Sunt foarte mulČumit.
@@corteliu Aparent nu o folosesti corect/ideal. 16 kW ar trebui sa fie mult supradimensionat pentru 140 mp. Buffer-ul scade si el randamentul, folosirea unei temperaturi mari a apei (55°C) nu ajuta pentru un SCOP bun, folosesti temperatura asta in instalatia sau ai grup de amestec? Probabil ai putea imbunatati mult consumul.
Insa, daca tu esti multumit, asta este cel mai important, teoria nu prea mai conteaza. ð
Domnule PresurÄ confortul termic Čine Či de vÃĒrstÄ. PÃĒnÄ pe la 45 de ani dormeam dezbrÄcat cu nevasta lÃĒngÄ mine, nu conta temperatura optimÄ a camerei. Apoi am ÃŪnceput sÄ port pijama, sÄ pun o pÄturicÄ si apoi, clar pilotÄ. LÄsÃĒnd gluma la o parte folosesc un Čemineu pe lemne, doi-trei butuci zdraveni Či apoi aerul condiČionat menČine temperatura la 23grade pÃĒnÄ dimineaČa. Un aer inverter cu gaz r 410, mai "demodat" care consumÄ maxim 2kw pentru a menČine temperatura. In altÄ camerÄ un aparat inverter mai modern, cu gaz r 32 consumÄ 3kw. Lupta ÃŪmpotriva poluÄrii nu Čtiu dacÄ are ÃŪntotdeauna soluČii optime. VÄd cÄ aČi declanČat dezbateri intense, perfect, lumea are de ÃŪnvÄČat. Pe rÄutÄcioČi nu-i bÄgaČi ÃŪn seamÄ, ÃŪnvaČÄ si ei.
Eu traiesc in olanda si aici temperatura din casa e in mod obisnuit mai mica. Ciudat e ca ma adaptasem oarecum , dar aveti dreptate, cu varsta, imi place si mei sa am un "colt caldut" al meu...
Practic, un frigider inversat.
da
Va sugerez sa urmÄriČi inventia lui Ioan Telechi la Imperiul Leilor. Efectul e acelaČi doar ca nu foloseČte freon si compresor ci este doar un sistem electric si din spusele lui este mai eficient decÃĒt un sistem cu freon. Daca ceea ce spune el este adevÄrat si tehnologia lui se va dezvolta, pÄrerea mea este ca va fi revoluČionar.
A explodat instalaČia,nu vÄzui?Trebuie timp sa avansam
Plus ca invenČia nu-i a lui breee,se joaca copiii amatori de mici cu capsule Peltier'
ExistÄ lazi frigorifice de zwci de ani,frigidere mici profesionale,fÄrÄ zgomot,dar atenČie!!! Consuma 75-100W pentru 20-30Litri,pricepi?
Nu e nici o invenČie. CiteČte despre efectul Pelletier Či ai sÄ ÃŪnČelegið
Pelletier, asa se numeste efectul pe care l-a prezentat drept inventia sa iar asta constÄ ÃŪn degajarea sau absorbČia de cÄldurÄ la joncČiunea dintre doi conductori diferiČi (metal sau semiconductor), cÃĒnd prin aceasta circulÄ un curent electric de asemenea doi conductori diferiti incalziti la capete devin generator de curent. Efectul Seebeck constÄ ÃŪn apariČia unei tensiuni electromotoare ÃŪntr-un circuit format din douÄ conductoare de naturÄ diferitÄ cu joncČiuni la capete, cÃĒnd cele douÄ joncČiuni se aflÄ la temperaturi diferite.
Pe baza acestui efect se realizeazÄ termocupluri pentru mÄsurarea temperaturii. Fenomenul invers este efectul Peltier, care se manifestÄ prin absorbČia sau degajarea unei cantitÄČi de cÄldurÄ (diferitÄ de cea degajatÄ prin efectul Joule al curentului electric) ÃŪntr-o joncČiune formatÄ din doi conductori sau doi semiconductori diferiČi Či zona de contact, de exemplu ÃŪntre cupru Či fier apare o tensiune electromotoare de contact.DacÄ prin joncČiune trece un curent electric cu semnul de la cupru la fier, electronii din zona de contact capÄtÄ energie cineticÄ suplimentarÄ Či temperatura joncČiunii creČte; la trecerea unui curent ÃŪn sens invers, temperatura joncČiunii scade.
DacÄ ÃŪntr-un circuit electric cu douÄ joncČiuni ca cele de mai sus, circulÄ un curent electric cu sens adecvat, se poate realiza un transport de cÄldurÄ de la joncČiunea mai rece la joncČiunea mai caldÄ. Efectul Peltier este folosit la realizarea minifrigiderelor.
Teoria cu practica nu este acelaČi lucru
DouÄ mari institute de cercetare, unul din germania ISH Fraunhofer Či celalalt din elveČia, Buchs, monitorizÃĒnd aplicaČii reale, SCOP nu a fost mai mare de 3,8.
Genial, montez zilnic rahaturi din astea. Inca nu am vazut video ul , dar pot de pe acum sa zic ca nu este rentabila pentru romania..
Ghita, âa montaâ Či âa folosiâ sunt 2 lucruri total diferite. Te-ai gÄsit instalatoruâ luâ peste sÄ te contrazici cu ditai fizicianuâ ðĪĢ
â@@sebastiancostin3478nici despre tine nu stiu ce sa zic daca compari "ditai fizicianul" cu "instalatorul" dar te-ai gÄsit sÄ comentezi ca sÄ te afli si tu ÃŪn treabÄ.
La pompele de caldura nu se recomanda calorifere si mai degraba convectoare (niste calorifere cu ventilatoare care sa mareasca randamentul)
corect, daca pui calorifere trebuie sa fie supradimensionate ceea ce arata urat si nici nu pot incalzi rapid.
Nu se mÄreČte nimic. Randamentul ramine , se schimba senzaČia...
@@mirceageogloman676 randamentul de emitere a caldurii va creste desigur, nu randamanetul de productie. Un radiator la care vine constant caldura va emite mai bine caldura daca aerul trece prin el mai rapid decat prin convectie naturala. Acelasi principiu ca si la radiatorul de la masina pentru incalzire in interior. Caldura care ajunge in cabina este mai multa daca dai ventilatia pe o treapta mai mare. In instalatie este aceasi temperatura, diferenta este cat de repede este livrata.
@@alexandruilea915 corect, asta am spus si eu, dar mai pe scurt. Un calorifer simplu cu 25-30 grade in el nu cred ca poate mentine o camera la o temperatura optima decat daca nu sunt pierderi de caldura aproape deloc
Exact, pentru temperatura este mai scazuta decat in caloriferele centralelor pe gaz. Dar ma rog, detalii pentru episoadele urmatoare.
In ce conditii o pompa de caldura consuma 1kWh si produce 5kWh si in ce perioada a anului?
Depinde foarte mult de tipul pompei de caldura. O pompa de caldura aer apa este eficienta cand temperatura mediului exterior este pozitiva iar acel factor este calculat cand temperatura exterioara este de 7 grade celsius. O pompa apa apa nu este influentata de temperatura mediului exterior, apa de unde vine energia este din foraj si are aceeasi temperatura indiferent de anotimp
Ceva ce nu pricep!de ce dupÄ condensare trebuie sÄ aduci freonul la -18 grade Či nu ÃŪl compresam la temperatura de ieČire din calorifere?
la iesire din condensator este in stare lichida si nu are un aport de energie luata din mediul exterior astfel incat sa avem acel plus de care avem nevoie. Lichidele nu pot fi comprimate.Voi explica acest lucru in urmatorul video depre ce se intampla in componentele pompei.
Eu nu am ÃŪnČeles ceva: De ce nu s-ar raci freonul pana la 5 grade prin vava de expansiune ÃŪn loc de -18 Či s-ar renunČÄ de tot la schimbul de cÄldurÄ cu aerul de afara? BÄnuiesc ca acea valva poate raci freonul doar foarte mult. DacÄ vezi acest comentariu as fi curios de un rÄspuns ÃŪn videoclipul urmator
Intradevar , nu ai inteles , nu valva raceste freonul ci schimbarea de stare a acestuia de la lichid la gazos . Practic , toata functionarea pompei , ca si a frigiderelor si instalatiilor de aer conditionat , se bazeaza pe schimbarea de stare a freonului din lichid in gaz si invers , procese ce au loc cu absorbtie si cedare de energie ( caldura ) .
@@mariusstan352 aaaa ok am ÃŪnČeles acum. MulČumesc!
mie nu imi este intuitiv procesul si cu aceeasi intrebare raman si eu pana inteleg schimbul termic in schimbarea de stare
@@razvanvlad6885 Atunci cand un gaz se comprima acesta se incalzeste. El intra in schimbatorul de caldura din casa pentru a ceda caldura apei din interior. Ulterior la iesire din schimbatorul de caldura el este aproximativ la temperatura apei din interior. Prin trecerea prin valva de expansiune el este lasat sa-si creasca volumul iar acest efect il face foarte rece. Foarte rece fiind are nevoie de o sursa de caldura pentru a ajunge la 5 grade celsius si de aceea este trecut printr-un radiator care are atasat un ventilator pentru ai mari eficienta. Aerul exterior de 5 grade trece peste radiatorul care este mai rece si ii cedeaza caldura. Astfel, aerul care iese din pompa de caldura este foarte rece deoarece a cedat caldura freonului. Dupa aceasta faza freonul este recompresat si urcat la o temperatura mare pentru a reface circuitul. Gandestete la pompa de caldura ca si la un burete cu care muti apa dintr-o galeata in alta. Strangi buretele pentru a stoarce apa in cea dea doua galeata si il lasi sa se relaxeze pentru a absorbi apa din prima galeata. Daca in prima galeata nu ar mai fi apa de unde sa aduca apa buretele pentru galeata 2? Cam asa si la pompa, fara unitatea exterioara care sa aduca caldura din diferite medii (aer, sol sau apa) pompa nu poate genera mai multa caldura decat consumul de energie electrica si deci ar avea un randament de 1kWh electric la 1 kWh termic. Ma rog, in realitate ar fi putin mai mult termic pentru ca ti-ar absorbi caldura din camera unde ai instalat pompa de caldura prin peretii tevilor de freon.
CredeČi cÄ puteČi ÃŪncÄlzi casa cu 30 grade ÃŪn calorifere ? Ventila ÃŪn calorifere se face bine ÃŪncepÃĒnd cu o temperaturÄ de 50 grade .
25 de grade in apa din calorifere nu e prea putin pt a putea incalzi o locuinta? Pai mie imi e frig daca sunt 24 de grade in casa, abia la 25-26 ma simt confortabil, si pt 25-26 grade in casa, apa din calorifere trebuie sa aiba cel putin 60 de grade cand afara sunt 0 grade. Daca vorbim de temperaturi cu minus(-10/-15grade), fara 70-75 de grade in calorifere, nu faci 26 in casa(parerea mea de om fara experienta in domeniul incalzirii) :))
Cu 25 in calorifere o sa dureze o eternitate sa incalzesti casa daca nu ai calorifere pe fiecare perete. Noi avem pompa aer-apa cu incalzire in pardoseala si calorifere in aceleasi camere si temperatura apei o tin undeva intre 33 si 40 celsius pentru un randament bun. La 33 porneste pompa si se opreste la 40. Pompa fiind modulara folosesc doar 50% din capacitatea ei in majoritatea zilelor dar incalzirea zilnica (la o temperatura intre -5 si 2 grade celsius afara) dureaza circa 8-10 ore pe zi (timp in care ruleaza pompa total). Daca as porni integral pompa as putea ridica temperatura apei mai rapid dar ar scadea eficienta. Asa incalzesc cu temperature de 30 de grade celsius in apa intr-un timp indelungat pentru a maximiza eficienta.
Ai dreptate dar aceČtia o prea laudÄ,mai exact sunt pe lÃĒngÄ 'caldura'
Depinde si de ce vrei sa incalzesti, dar e drept ca, in practica, 25 de grade e putin; Cred ca aici am ales un exemplu prost. Peste 30 de grade era mai bine, chiar mai mult. Dar in fine, difera de la pompa la pompa, de la situatie la situatie. Daca ati inteles principiul, cred ca e OK.
De ce mai este nevoie de valva de expasiune si evaporator (pt a raci freonul de la 20 la -18, si apoi a-l incalzi la +5) si nu intra direct in compresor la 20 de grade?
Deci tu vrei sa dispara toata partea din stanga imaginii de la 4:48, partea care ia caldura din exterior? Adica sa ia caldura din aerul din camera in loc sa ia de afara si sa bage in calorifer aceeasi cantitate, care sa incalzeasca la randul lui aerul din camera cu fix aceeasi cantitate? Poti face si asta daca urmaresti castig de caldura zero in camera. Asa cum e desenat in imagine, afara se castiga caldura din diferenta de la 5 grade la -18 grade, iar inauntru se cedeaza caldura in diferenta de la 40 de grade la 20 de grade. Intotdeauna corpul mai cald cedeaza caldura celui mai rece la contact direct. Compresorul si valva de expansiune incalzesc/racesc freonul pe baza altor legi ale fizicii, nu pe baza de contact direct. A promis Presura ca va explica mai pe larg in episodul viitor cum e cu schimbarea de temperatura la gaze in functie de presiune si volum.
eu vreau sa dispara valva de expansiune (din partea dreapta) si evaporatorul (din partea stanga). Compresorul ramane, si incalzeste in continuare freonul la 40 de grade. Dar in loc sa-l ia de la 5 grade, il ia de la 20 de grade, cat iese din casa.
@@oldman8889 th-cam.com/video/xI3AxVBt46M/w-d-xo.html
@@oldman8889 Mai incerc o explicatie altfel. Un gaz poate fi incalzit nu doar facand focul sub el, ci si marind presiunea si/sau volumul. Compresorul nu este o rezistenta, ci acolo se mareste presiunea freonului. Daca dispare valva de expansiune, freonul ramane comprimat, la urmatorul ciclu de intrare in compresor energia necesara pentru o comprimare care sa mai creasca temperatura de la 20 la 40 este mai mare, la urmatorul si mai mare si tot asa... Nu doar ca se ajunge la consum imens de energie, dar un gaz are si el o limita pana la care poate fi comprimat. Daca exista valva de expansiune, gazul este decomprimat si ciclul poate sa se reia.
De ce scoatem freonul afara sa se rÄceascÄ, ca imediat apoi sa ÃŪl ÃŪncÄlzim iar? De ce nu pastram pe cat se poate temperatura lui?
Nu scoti freonul afara sa se raceasca, ci sa se incalzeasca. Il racesti mult (-18 grade era in exemplu) inainte sa-l scoti, ca sa se se incalzeasca de afara (5 grade era in exemplu afara) Desi 5 grade pare rece, comparat cu -18 e mai cald, deci aerul va ceda caldura freonului. La intrarea in casa il vei incalzi (40 de grade) peste temperatura pe care vrei sa o obtii la apa calda (20 de grade) pentru a se putea raci si in concluzie a ceda caldura la contactul cu apa calda
Se poate estima consumul de energie electricÄ (pe zi) al unei pompe de cÄldurÄ in scenariul unei nevoi de 19 grade la interior timp de 24 ore?
Fara celule te rupe
Se poate dar mai trebuie si alte informatii. Ca exemplu, incalzesc o casa de 135 mp la 24°C interior cu instalatie calorifere si pompa de caldura de 6 kW si iarna trecuta consumul a fost de 2.500 kWh doar pentru incalzire. Apa calda menajera o face tot centrala pe gaz. Pentru comparatie pe un sezon de iarna cu centrala gaz consumul era de 12.000 kWh (aprox. 1200 mc gaz) inclusiv apa calda menajera. Cam 2.000 kWh ar fi consumul pe sezon de iarna de apa calda menajera.
1kw pe orÄ , la 24 de ore ori 30 de zile..cam mult pentru peste 50 la sutÄ din populaČia romÃĒneascÄ cu un salariu de 500 de euro pe lunÄ..ce ziceČi?
FaČÄ de 30-40 de euro pentru gaz..
@@mihaimihail6375 Zicem ca e putin mai complicat. Consumul unei surse de caldura este dat de necesarul casei. Pierde casa 3 kW pe ora, sursa trebuie sa-i adauge. Cu gaz inseamna chiar 3 kWh x 0,31 lei cat costa gazul COMPENSAT. Cu pompa de caldura avand un COP 3 inseamna 1 kWh x 0,7 lei cat costa electricitatea la Hidroelectrica. Cu un COP de 5 inseamna 0,6 kWh x 0,7 lei.
Desi am centrala gaz am folosit doar pompa de caldura pentru incalzirea casei iarna trecuta (apa calda menajera a ramas in sarcina centralei pe gaz) iar costul a fost mai mic decat cu gaz. Evident, pompa de caldura a costat (pe mine putin, doar 13.000 lei cu tot cu instalare) si va dura ceva ani buni sa se recupereze chiiar si aceasta mica investitie. Acum am insa si PV prin programul AFM, recuperarea devine mai rapida. Insa pentru cei care nu au acces la reteaua de gaz, sau care inca nu au gaz iar bransamentul costa, ar putea sa ia in considerare o pompa de caldura in locul unei centrale pe lemne, peleti, electrice sau chiar gaz. Important insa este ca ea sa fie dimensionata corect pentru necesarul casei si casa sa fie reznabil izolata, de preferat.
Folosesc o pompa de caldura de 6 kW pentru o casa de 135mp cu instalatie radiatoare, apa pe tur intre 30-36°C (36 la minus 9 grade afara, minimul iernii trecute in zona in care locuiesc) si cu 24-45 grade in casa. Consum total octombrie-mai 2.500 kWh x 0,7 lei = 1.750 lei. Precedentele trei ierni am consumat 10.000 kWh gaz x 0,31 pret actual gaz = 3.100 lei.
@@mihaimihail6375 30 EUR gaz pe luna? Doar aragaz sau cum incalzesti o casa cu 150 lei? 150/0,31=483kWh pe luna?! Ce casa incalzesti iarna cu 483 kWh pe luna?
Inseamna un necesar orar de 0,67 kW. Poate in octombrie/mai?
Nu bagi nici 1kw bagi de la 10kw in sus pompa functioneaza ca un motor pe motorina prin incalzirea aerului prin compresie eficienta este foarte scazuta iarna
ajungi la peste 100.000 de lei cu pompa instalatie panouri si manopera instalator
kw electric nu e tot una cu kwh termic, kwh termic nu exista in sistemul de masura international e doar folosit pentru mintirea cumparatorului, caldura se masoara in joule
Era mai corect daca scria-ti in titlu ca : â bagi 1kwh de energie electrica si scoti 5kwh de caldura ( energie termica ) â , fiindca : Energia = Putere x Timp = kW x h = kwh
Mai pe scurt, lucrul mecanic al compresiei se transformÄ ÄŦn cÄldurÄ pentru cÄ freonul comprimat se ÄŦncinge. Valva lasÄ gazul sÄ se dilate Åi aÅa ajunge la -18 grade
Care este diferenČa cu ACul? Compresorul mai puternic?
ACul are Åi o funcČie stupidÄ ÄŦn clÄdirile care se ÄŦncÄlzesc iarna peste 22 grade din alte cauze ÄŦn interior(caldura de la aparatura industrialÄ). ÄŠn loc sÄ aducÄ aer rece proaspÄt ÄŦn camerÄ, ÄŦnvarte freonul ÄŦn circuit ca sÄ rÄceascÄ aerul.
ACul nu aduce aer rece de afarÄ, roteÅte numai freonul ÄŦntre camerÄ Åi unitatea exterioarÄ.
Panourile solare sunt bune?
Foarte bune.
Inteleg ca o pompa de caldura de 25 kw consuma 5 kw intr-o ora ,deci foarte mare consum !