- LC Troubleshooting | Retention Time Shift | how to change retention time in HPLC
your quires;
Retention times must be reproducible from run to run. When problems occur, late, early or variable peak retention times may be observed. There are lots of potential causes to change in retention time.
HPLC
#hplc
hplc troubleshooting interview questions and answers
hplc troubleshooting
hplc peak troubleshooting
hplc interview questions and answers
HPLC sample preparation
hplc injection accuracy
pharmaceutical industry
quality control department
voice of kayani
lc troubleshooting
hplc troubleshooting
hplc troubleshooting shimadzu
english excel
lc troubleshoot rt shift
liquid chromatography
lc
retention time shift
lc maintenance
how rt shift in hplc
what are the causes of rt shift in hplc
early retention time in hplc
rt shift
shift in retention time in hplc
retention time shift in hplc
retention time shift early
why lc retention time shifting
factor affecting retention time in hplc retention time in hplc
#Changeinretentiontime
#LCtroubleshooting
#HPLCTroubleshooting
#RTshift
#RetentiontimeinHPLC
#Retentiontimeshift
#LCchromatography
#Liquidchromatography
#HPLCchromatography
#Qualitycontrol
#QC
#ReasonsforRTshiftinHPLC
#Pharmaindustry
#Pharmajobs
#Pharmanaukri
------------------------------------------------------------------------
#Changeinretentiontime #LCtroubleshooting #HPLCTroubleshooting #RTshift #RetentiontimeinHPLC #Retentiontimeshift #LCchromatography #Liquidchromatography #HPLCchromatography #Qualitycontrol #QC #ReasonsforRTshiftinHPLC #Pharmaindustry #Pharmajobs #Pharmanaukri #EnglishExcel
follow on Instagram;
/ safdarkhankayani
like us on Facebook;
www.facebook.c...
subscribe for more videos;
/ @voiceofkayani5419
linkdin;
www.linkedin.c...
email I'd;
chemist.kayani143@gmail.com
Sir please make video on Gradient Valve Test (GPV) in HPLC calibration Calculation.
How to change RT in normal phase
By changing in polarity of mobile phase, you can do it...
More polar mobile phase increase the RT. and non polar mobile phase decrease the RT.
Salam sir
Walaikum salam
Lamp regeneration ho sakti hy
Peak ae he nhi to sir kia krein. Mobile phase same ho. Peak do din pehly a rhi thi ab nhi a rhi sir is ka reason lamp energy hy.
Bhit sarai reasons Hain will tell you..
May be sample kharab ho giya hai
May be ghalat sample ho
May be sample detorate ho giya ho
May be lamp energy issue
May be vial missing ho
May be vial position wrong ho in sequence file
May be mobile phase contaminated
May be mobile wrong choose kar Liya ho
May be method file wrong ho
May be lamdamax different ho and so on
Recommendations is that make all preparation again freshly
Why lamp off during column washing and how to lamp off ?
Dear,
During washing lamp must be off this is because,To save the lamp hours .. during washing no need of lamp and detector to be ON