LC Troubleshooting | Retention Time Shift | how to change retention time in HPLC

แชร์
ฝัง
  • เผยแพร่เมื่อ 1 ต.ค. 2024
  • LC Troubleshooting | Retention Time Shift | how to change retention time in HPLC
    your quires;
    Retention times must be reproducible from run to run. When problems occur, late, early or variable peak retention times may be observed. There are lots of potential causes to change in retention time.
    HPLC
    #hplc
    hplc troubleshooting interview questions and answers
    hplc troubleshooting
    hplc peak troubleshooting
    hplc interview questions and answers
    HPLC sample preparation
    hplc injection accuracy
    pharmaceutical industry
    quality control department
    voice of kayani
    lc troubleshooting
    hplc troubleshooting
    hplc troubleshooting shimadzu
    english excel
    lc troubleshoot rt shift
    liquid chromatography
    lc
    retention time shift
    lc maintenance
    how rt shift in hplc
    what are the causes of rt shift in hplc
    early retention time in hplc
    rt shift
    shift in retention time in hplc
    retention time shift in hplc
    retention time shift early
    why lc retention time shifting
    factor affecting retention time in hplc retention time in hplc
    #Changeinretentiontime
    #LCtroubleshooting
    #HPLCTroubleshooting
    #RTshift
    #RetentiontimeinHPLC
    #Retentiontimeshift
    #LCchromatography
    #Liquidchromatography
    #HPLCchromatography
    #Qualitycontrol
    #QC
    #ReasonsforRTshiftinHPLC
    #Pharmaindustry
    #Pharmajobs
    #Pharmanaukri
    ------------------------------------------------------------------------
    #Changeinretentiontime #LCtroubleshooting #HPLCTroubleshooting #RTshift #RetentiontimeinHPLC #Retentiontimeshift #LCchromatography #Liquidchromatography #HPLCchromatography #Qualitycontrol #QC #ReasonsforRTshiftinHPLC #Pharmaindustry #Pharmajobs #Pharmanaukri #EnglishExcel
    follow on Instagram;
    / safdarkhankayani
    like us on Facebook;
    www.facebook.c...
    subscribe for more videos;
    / @voiceofkayani5419
    linkdin;
    www.linkedin.c...
    email I'd;
    chemist.kayani143@gmail.com

ความคิดเห็น • 11

  • @pathanraufkhan7604
    @pathanraufkhan7604 9 หลายเดือนก่อน +1

    Sir please make video on Gradient Valve Test (GPV) in HPLC calibration Calculation.

  • @tahiraftab1702
    @tahiraftab1702 7 หลายเดือนก่อน +1

    How to change RT in normal phase

    • @voiceofkayani5419
      @voiceofkayani5419  7 หลายเดือนก่อน

      By changing in polarity of mobile phase, you can do it...
      More polar mobile phase increase the RT. and non polar mobile phase decrease the RT.

  • @saranoor1981
    @saranoor1981 9 หลายเดือนก่อน +1

    Salam sir

  • @saranoor1981
    @saranoor1981 9 หลายเดือนก่อน

    Lamp regeneration ho sakti hy

  • @saranoor1981
    @saranoor1981 9 หลายเดือนก่อน +1

    Peak ae he nhi to sir kia krein. Mobile phase same ho. Peak do din pehly a rhi thi ab nhi a rhi sir is ka reason lamp energy hy.

    • @voiceofkayani5419
      @voiceofkayani5419  9 หลายเดือนก่อน

      Bhit sarai reasons Hain will tell you..
      May be sample kharab ho giya hai
      May be ghalat sample ho
      May be sample detorate ho giya ho
      May be lamp energy issue
      May be vial missing ho
      May be vial position wrong ho in sequence file
      May be mobile phase contaminated
      May be mobile wrong choose kar Liya ho
      May be method file wrong ho
      May be lamdamax different ho and so on

    • @voiceofkayani5419
      @voiceofkayani5419  9 หลายเดือนก่อน

      Recommendations is that make all preparation again freshly

  • @sauravtrivedi5197
    @sauravtrivedi5197 9 หลายเดือนก่อน +1

    Why lamp off during column washing and how to lamp off ?

    • @voiceofkayani5419
      @voiceofkayani5419  9 หลายเดือนก่อน

      Dear,
      During washing lamp must be off this is because,To save the lamp hours .. during washing no need of lamp and detector to be ON