Load Cell Controller Setting and Calibration

แชร์
ฝัง
  • เผยแพร่เมื่อ 21 พ.ย. 2018
  • ATO load cell controller is a digital panel meter for strain gauge load cell and force sensor.
    Buy it online, www.ato.com/digital-panel-meter
    Before using a load cell controller, we should set basic parameters and calibrate the measuring range. In this video, we choose an s type load cell and a 2kg standard weight to finish the setting and calibration. Finally, ATO also show you how to set tare value and measure tare.
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 55

  • @jasonleonardo3641
    @jasonleonardo3641 4 ปีที่แล้ว +1

    Asap. Positive response is highly appreciated. Thank you so much

  • @pba21
    @pba21 4 ปีที่แล้ว

    Great 👏! Add ALARM like the Pid video. Thank you

  • @sadhunikul2611
    @sadhunikul2611 2 ปีที่แล้ว

    Very useful

  • @SunitaSingh-jc9pq
    @SunitaSingh-jc9pq 2 ปีที่แล้ว

    Nice video

  • @hossamyassin5971
    @hossamyassin5971 4 ปีที่แล้ว

    Amazing... But I wonder is this controller works with movable weighing belt and how many set points in it your replay will be appreciated..

  • @pba21
    @pba21 4 ปีที่แล้ว +3

    Amazing 👏! But how do you add alarm/action (hopper, light etc.) once the SV is reached?

  • @nymrodtroivillasoto2153
    @nymrodtroivillasoto2153 2 ปีที่แล้ว

    Thank you for your video ..
    Can you help to how to factory reset to the load cell controller?? Please

  • @mnouredine9900
    @mnouredine9900 5 ปีที่แล้ว +3

    Hi, very nice video well explained, I have a question for you Sir, the two relays of this controller, what is their job?
    You can set the desired value (weight) for activation and deactivation of the relay?

  • @robinyookr8775
    @robinyookr8775 4 ปีที่แล้ว

    Thank you ATO Automation for this video. I have a question regarding the calibration. If you mount the eye bolts to be able to hang the load cell, won't there be a deviation in the calibration? Or a shift in the zero point? Is not it better to hang the load cell and then calibrate by attaching a weight to the load cell?
    Thank you in advance!

    • @ATOcom
      @ATOcom  4 ปีที่แล้ว +1

      It can be calibrated in the plane, and the display needs to be cleared after installing the lifting ring.
      Zero drift will only appear after a long period of use, just recalibrate.

  • @cekalian10
    @cekalian10 3 ปีที่แล้ว

    Hi, may I know how can the readings of weight be stored in a pc?

  • @ascreation902
    @ascreation902 4 ปีที่แล้ว

    Sir, Plz tell inno load cell calibration settings

  • @Boerikoe
    @Boerikoe 3 ปีที่แล้ว

    Good day, thank you for the video it is a great help. Regarding the holding of the "Peak Value" how can this be set ? I am using a load cell on the end of a Linear Actuator to evaluate the force needed to break the bond between two parts. I would thus need a high sampling speed, and to hold the Peak Value. Will this unit be able to do this ? and how can I set this ? Thank you for your help.

    • @ATOcom
      @ATOcom  3 ปีที่แล้ว

      Its sampling frequency is 10 times/second.The peak setting method is in the instruction manual.

    • @aiman4917
      @aiman4917 ปีที่แล้ว

      Hi.. Have u found the solution for your question. If u dont mind, can u share how to use that peak function.

    • @Boerikoe
      @Boerikoe ปีที่แล้ว

      @@aiman4917 Good day, No I couldn't find how to set this in the instruction manual. I changed to a FUTEK unit.

    • @aiman4917
      @aiman4917 ปีที่แล้ว

      @@Boerikoe Can u provide me the link to buy that model?

  • @santoshkumarsharma5790
    @santoshkumarsharma5790 4 ปีที่แล้ว

    Sir shift up zero pick Ko set Karna hai kaisay karagay

  • @juanherrera4629
    @juanherrera4629 ปีที่แล้ว

    Hola para configurar AlPHA 2 de Ditel

  • @emiliox210
    @emiliox210 4 ปีที่แล้ว

    Hello, Iam looking for a load cell that can register dynamic force at 1kHz, is it the same what to calibrate a load cell for that like you did in the video?

    • @ATOcom
      @ATOcom  4 ปีที่แล้ว

      Sorry, This video is only for ATO products.

  • @kiranchoudhari4717
    @kiranchoudhari4717 3 ปีที่แล้ว

    Can you make video on Gefran 40 controller Calibration, using strain gauge

  • @pepopopi271
    @pepopopi271 4 ปีที่แล้ว

    If your outlet is 220v, do you need a trasnformer or can you plug it directly into wiring socket?

    • @ATOcom
      @ATOcom  4 ปีที่แล้ว

      No need transformer in the video type. www.ato.com/5-digit-display-controller-for-pressure-sensor

  • @learningandearning1755
    @learningandearning1755 2 ปีที่แล้ว

    Sir i have a question, I have used this controller on a packing machine. Control the two valves through alarm 1 and alarm 2 load cells. But after a circle is completed, alarm 1 and alarm 2 start working automatically again after 10 sec Please suggest me how to turn this time off or increase it.

  • @OnetrebuH
    @OnetrebuH 4 ปีที่แล้ว

    Does that AL1 and AL2 alarms have output on relay?
    Can I set weight (on AL1 and AL2) that will cause high state on relay?

    • @ATOcom
      @ATOcom  4 ปีที่แล้ว

      yes

  • @MatriculationPhysics
    @MatriculationPhysics 4 ปีที่แล้ว

    hi, I just wondering, would it be safe to connect this load cell indicator to a 240 V AC power supply?

    • @ATOcom
      @ATOcom  4 ปีที่แล้ว +1

      Can't connect it to 240V

  • @erkan_rua
    @erkan_rua 26 วันที่ผ่านมา

    We are getting Error 1 if we want to set calibration do you have advice

  • @anirudhdiwakar987
    @anirudhdiwakar987 2 ปีที่แล้ว +1

    Hello, iam an intern at a startup looking to build a static test bed for a high power rocket motor( with total impulse in the range of 15000N.s, i.e, with peak loads of more than 500kg). My question is, can this be used along with an arduino? If so, what kind of amplifier do we need? Will the likes of ATO-LCS-TJL-1 be able to measure loads as small as 40kg?
    I hope that you do answer my queries, seeing as a lot of recent comments have been unanswered. Thank you in advance!

    • @ATOcom
      @ATOcom  2 ปีที่แล้ว +1

      1. We have weighing transmitters that convert weight signals into analog signals or digital signals, maybe this can be used for your arduino.
      www.ato.com/load-cell-transmitter-output-0-5v-4-20ma
      www.ato.com/digital-load-cell-amplifier-output-4-20ma-0-10v-rs485
      2. ATO-LCS-TJL-1 can measure loads less than 40kg.
      www.ato.com/tension-load-cell-s-type-50kg-to-20-ton

    • @anirudhdiwakar987
      @anirudhdiwakar987 2 ปีที่แล้ว +1

      @@ATOcom thans for the reply!

  • @bensonhuliganga3459
    @bensonhuliganga3459 3 ปีที่แล้ว

    sir I have a question, potentiometer can control speed right(yes) then will it work to use load to control speed?

    • @ATOcom
      @ATOcom  3 ปีที่แล้ว

      Maybe you need a load cell transmitter to change the weighing signal to 0~10V or 4~20mA to facilitate the speed control of the motor.
      This link for you, www.ato.com/load-cell-transmitter-output-0-5v-4-20ma
      Because the output signal of the load cell is difficult to directly use as the speed control of the motor.

  • @johnt.8936
    @johnt.8936 4 ปีที่แล้ว

    Hello. Do this device have an output 0-10v or 4-20mV to connect it to a PLC? Do you have it for sale in your store? Thank you.

    • @ATOcom
      @ATOcom  4 ปีที่แล้ว

      Sorry, we don't have it.

    • @pakistanmotarway8096
      @pakistanmotarway8096 4 ปีที่แล้ว

      Sir You computer Waiting bridge To lose weight from Show the way

  • @alielbuz7734
    @alielbuz7734 2 ปีที่แล้ว

    Добрый день что лучше купить это контроллер или contronix

  • @jasonleonardo3641
    @jasonleonardo3641 4 ปีที่แล้ว

    Hello! Can I ask how to reset all the parameters?

    • @ATOcom
      @ATOcom  4 ปีที่แล้ว

      Did you buy this model?

    • @aggelosnik5898
      @aggelosnik5898 3 ปีที่แล้ว

      I have bought this model too and i need to know how to reset to factory!

  • @tanphattran1884
    @tanphattran1884 4 ปีที่แล้ว

    Hi, it seem too slow display

  • @dedesuherman8954
    @dedesuherman8954 2 ปีที่แล้ว

    Berapa harganya ?

  • @sanjeevelectricalco
    @sanjeevelectricalco 2 ปีที่แล้ว

    Price pls
    Load indicator out 0 to10v 4 to 20m
    for plc

    • @ATOcom
      @ATOcom  2 ปีที่แล้ว

      I guess you need a weighing transmitter, see the price link below.
      www.ato.com/load-cell-transmitter-output-0-5v-4-20ma
      www.ato.com/digital-load-cell-amplifier-output-4-20ma-0-10v-rs485

  • @well1168
    @well1168 2 ปีที่แล้ว

    ขอเบอร์หน่อยครับ

  • @AsgarAli-dk8jr
    @AsgarAli-dk8jr 3 ปีที่แล้ว +1

    Sale pehle karna ikhle