Hot Tub Balboa Spa Pack Not Heating / Test a Hot Tub Heating Problem

แชร์
ฝัง
  • เผยแพร่เมื่อ 30 ก.ค. 2024
  • Hot Tub Balboa Spa Pack Not Heating / Test a Hot Tub Heating Problem
    Testing a hot tub balboa spa pack for a heating problem is very simple and low cost to fix.
    ❤ SUBSCRIBE - th-cam.com/users/VIPPoolsand...
    🎁TIP JAR - PAYPAL: info@vippools.ca
    Legal Notice: Any electrical connected to your hot tub or swimming pool should be worked on by a licensed electrician or service technician. Please call your local pool/hot tub Technician for a service call before doing any work yourself.
    -------------PAID LINKS BELOW-------------------------
    Hot Tub Heater Element:
    5.5KW Element - amzn.to/39Uk95D
    4.0KW Element - amzn.to/3oWHE2q
    ----------------------------------------
    Hot Tub Volt Tester:
    amzn.to/2OzJ1aJ
    ----------------------------------------
    Hot Tub Capacitor Tester:
    amzn.to/3dlLpMu (Best)
    amzn.to/3dlLVdo (Better)
    -----------------------------------------
    Hot Tub Amp Tester:
    amzn.to/3rXMgqL
    -----------------------------------------
    Hot Tub o-Ring Lube
    amzn.to/3rVKuXo
    ------------------------------------------
    #hottub #hottubnotheating #balboaspapack

ความคิดเห็น • 361

  • @davidbrooke4829
    @davidbrooke4829 2 ปีที่แล้ว +1

    i replaced heat element, checked for air locks, i have voltage at the element. and if you shut valves on the union to heater, it gets hot.
    At the filters their is no sucking . pressing jets 3 on immediately cuts the heating symbol off.
    no error codes. any advice greatly appreciated

  • @swedishkev
    @swedishkev 2 ปีที่แล้ว +1

    HI again, I have got my balboa circuit board back from the repairers. It warms only to 29 degrees even if I have it set for 38 degrees. All relays have been changed. When I lowered the heat to 26,I see the temp light goes off. And I hear a small click. Then I put it back to 38 and get a small click. The heat then flashes, but it is not going over 29 ? The fuses look fine, but the big main one is not glass, so would need to check that one. I checked the AC current on the element, with it all powered up, And it read nothing. is this strange or what? The element is warmish to touch not hot to burn yourself. I need to switch it off now to check, the ohms. just checked the ohms, around 18,9-19? What does this mean if it is not around 11 or 12? I don't know where the problem is, any ideas?

  • @gilwright5349
    @gilwright5349 2 ปีที่แล้ว +1

    i Have a master spa and stopped heating replaced heater and no difference. BalBoa EL1000 Mach 2 board.
    Have voltage coming in and heat light displays on panel. Do not have 240 on heater terminals. Relay?? if so don't see identifying numbers to replace. How could i find the proper relay.

  • @opera5714
    @opera5714 2 ปีที่แล้ว +1

    Balboa RS101 control board. I removed the board and nothing is burned or indication of board heating. Each relay coil measures either 80 or 160 ohms. Heater element is 15 ohms. No voltage on element. Just doesn't heat. There seems to be sufficient flow. It is in the standard ST mode. I don't see anything which looks like an error code. Do these have a history of burned relay contacts? Spa is 7 years old. Am I missing something before buying replacement board or tearing this one apart? Thanks

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +1

      no volts on element.....replace the heat tube/element/cord. Its all one part.

  • @leonp4204
    @leonp4204 11 หลายเดือนก่อน +1

    Hi there, I’ve currently got my spa set to heat to 38 degrees Celsius. However it’s not getting past 36 degrees. I’m getting 22ohms across the heater and getting 0 volts when testing the heater itself. Any ideas? Thanks

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  11 หลายเดือนก่อน +2

      Most likely it's your heater element. Change that and see. Also, clean off your sensors at the same time.

  • @johnkernoschak2967
    @johnkernoschak2967 ปีที่แล้ว +1

    Thanks for the video. My problem is I have no 240v to the heater element. Does this mean it is the main control board? Maybe the relays on it?

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  ปีที่แล้ว +1

      Maybe. Is it not heating up? Are your settings all good? Would have to test the relays if everything above is all good.

  • @bnappi22
    @bnappi22 3 ปีที่แล้ว +1

    Not heating with SNS code. I checked all the voltages and don't have the 240v across the heating elements. I do have 120v and 240v across the white, black and red etc. I have also taken the filter out and still have the same issue. Should I change the heating element? The heating element is from 2009 and I'm not sure how often things go. Any help would be appreciated. TY

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  3 ปีที่แล้ว +1

      Is the pump pushing the water thru the heater tube well? The SNS code is a flow problem or sensor issue.

    • @bnappi22
      @bnappi22 3 ปีที่แล้ว +1

      @@VIPPoolsandSpas Pumps working good and I pulled the filter. I put the meter on the water heater and did not get 240volts. I ordered a new heater with sensors and will update you in a week. Thanks for the response.

  • @johnkirkpatrick9973
    @johnkirkpatrick9973 3 ปีที่แล้ว +2

    Thanks ran through all these steps. In Colorado so freezing is a big risk so trying to fix myself - No panel errors, circulation pump running, Heating element tests good, heating light is on, relay on the left closed, on the right first relay closed, second open. My second relay on right in series is open, heat light is on but the relay is open . Failed relay or do other sensors like the M7 control that relay? Any ideas what can cause that or other testing I can do? Can I replace the relay, I assume that is not an option so something is telling that relay to stay open or it failed? But if it is system telling it to open then seems like the light would be off or there would be an error message. Thanks for any suggestions!

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  3 ปีที่แล้ว +1

      What spa pack is in your hot tub? Model Number on the top of the pack) Look on circuit board for any burn marks. Might have to look behind it also if everything tests ok.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  3 ปีที่แล้ว +1

      Is everything working? Did you test everything? Do you have normal flow? How many pumps do you have? Name and model of hot tub? Also, if your worried about it freezing, follow this video: th-cam.com/video/yca83KAqzhc/w-d-xo.html

    • @johnkirkpatrick9973
      @johnkirkpatrick9973 3 ปีที่แล้ว +1

      @@VIPPoolsandSpas Everything but heat working, it has a circulation pump and it is pumping at normal volume. Replaced the heating element but no change and there is not voltage across the terminals. Can trace the voltage to the second relay on the right side connection and that relay is open with the heat light on. The hot tub is a Master Spas Twilight 8.2 with three pumps and the circ pump. To test I have disconnected the three main pumps and the control panel with no effect, no error messages on screen. Thanks for the link to the freezing instructions.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  3 ปีที่แล้ว +1

      @@johnkirkpatrick9973 If you have volts and amps and NO HEAT. It's the Board. NOTE: test amps also. If you have NO volts and NO amps, its the heater element or restricted flow.
      . It also depends on what spa pack you have. You said M7. whats the model? It's on the top of the spa pack (control pack)

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  3 ปีที่แล้ว +1

      @@johnkirkpatrick9973 You can also send pictures of the spa pack or equipment to info@vippools.ca

  • @wesleyblake8552
    @wesleyblake8552 ปีที่แล้ว +1

    Hi great video, my spa is the same and when the filtration was running the pump was making funny sounds, now it won't filter and wont heat I turned it off and on put it in stranded mode, the heater light then come on.... then flickers then goes off I have checked the fuse and its fine, do you have any idea what it might be? thanks Wes.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  ปีที่แล้ว +2

      Is the pump that pushes the water thru the heat tube running now? What noise? Could be a bearing or capacitor. When the heat light flickers, that means that it's thinking about heating.

    • @wesleyblake8552
      @wesleyblake8552 ปีที่แล้ว +1

      @@VIPPoolsandSpas Thanks for the reply, no that pump isn't running now but the other pumps are, the noise was a rattle ?

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  ปีที่แล้ว +2

      @@wesleyblake8552 test the fuses, test the pump capacitor.

  • @wildeyebilly1008
    @wildeyebilly1008 9 วันที่ผ่านมา +1

    I have a bp7 tp600 2 pumps,both 2 speed,a blower, and a circulation pump but when i put it on program 1 the 1st pump will not run with my heat causing a no flow issue, if i switch to program 6 it works but my circulation pum wont work on that program any suggestions

  • @coyko3953
    @coyko3953 2 ปีที่แล้ว +1

    Hey VIP pools and spas, I have a QCA spas hot tub with a Balboa VS300AV P/N 55506 and the heater stopped working so i changed it out (The whole tube including sensors) and it fixed the problem for a few weeks and now its not working again. Checking voltage coming in is good (neutral black 120, neutral red 120, black red 240) but checking the heating element posts is 0 volts. What are the odds another heater crapped out or would it be a board issue? No flow codes and the pump is working good, pulled the filter out as well to rule that out

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +1

      do you mean 0 amps?

    • @coyko3953
      @coyko3953 2 ปีที่แล้ว +1

      @@VIPPoolsandSpas no 0 volts, if i have one lead on the neutral and one on the first post its 120 v and the other post is 120 v as well but with both leads on the posts its 0 volts

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +1

      @@coyko3953 Check the GFCI breaker.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +1

      @@coyko3953 If you put the lead on neutral and one one red (120v). If you put on neutral and black (120v). If you put on red and black (240v) If thats what you did, something is wrong at a breaker. Also, make sure all those wires coming in are in there good.

    • @ericsvenpladsen9499
      @ericsvenpladsen9499 ปีที่แล้ว

      @@coyko3953 Did you ever solve your heating problem? I have the same symptoms, and I'm not sure if I should change the heater element or the circuit board.

  • @sleepyhollowschalet
    @sleepyhollowschalet 2 ปีที่แล้ว +1

    Hi VIP Pools and Spas. - hoping you can help. I have a Balboa BP501 that isn't heating. I can measure 240 across red/black on input block. I isolate the heating element and it measures about 11 Ohm. There is no voltage across the heating element posts when topside is calling for it. No errors given and just runs the pumps as it calls for it continually. I can measure 120V from each side of the element post to ground. All other functions are fine, pumps, lights and cleaning cycles.
    I assume it's the relays at this point but haven't pulled the board out to review closer. I did get a few "the heater is too hot" errors on a water change that was completed about a week before this happened. They were cleared from the topside and it continued to heat and did reach a temp of 102.
    Any thoughts you have would be greatly appreciated!

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +1

      test amps to confirm. sounds like its a relay but do the amps test anyway.

    • @sleepyhollowschalet
      @sleepyhollowschalet 2 ปีที่แล้ว +2

      @@VIPPoolsandSpas hey thanks for the help here. amps are measuring zero as well. seemed odd to me that I could measure 120 from element plug socket on either side to ground but I guess the relay closes the grounding not the supply?
      I guess I am pulling the board to confirm the relays, I can't find anywhere that gives the specs on these relays but assume they should be widely available to purchase and solder/replace. If you have any info on them I'd sure love it
      THANKS AGAIN SO MUCH!

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +1

      @@sleepyhollowschalet it's the element. If your in Blue, you can always call me for a service call. Lol

    • @sleepyhollowschalet
      @sleepyhollowschalet 2 ปีที่แล้ว +1

      @@VIPPoolsandSpas the element? But I can measure 11-12ohm on it isolated from controller. Begining to think I will replace it regardless while I'm in there based on age. Unfortunately, I'm a bit further north than blue.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +1

      @@sleepyhollowschalet that's why I have 4 ways of testing an element. What gave it away for me was the tripping part.

  • @derekparkinson3336
    @derekparkinson3336 ปีที่แล้ว +1

    Balboa spa pack MXBP501X New element. No volts or amps at heat tube connections? 240v coming in. Runs fine and shows its heating. But its not. Relay bad? Please help

    • @BIKEBLADESKATE
      @BIKEBLADESKATE 4 หลายเดือนก่อน

      Ever figure this out? I’m on the exact same page.

  • @nunzio1747
    @nunzio1747 2 ปีที่แล้ว +1

    The circuit breaker tripped recently in the winter. When I switched the power back on I was getting a sn code. I would get it to run but it wouldn't heat and eventually shut down with a hh code. Do you think I might have an ice blockage somewhere.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +1

      Can you push pump 1 button and does it turn on? any sound?

    • @nunzio1747
      @nunzio1747 2 ปีที่แล้ว +1

      Yes. Everything seems to work (except heat) when I let it sit but after a while it shuts down and I get the HH code.

    • @nunzio1747
      @nunzio1747 2 ปีที่แล้ว +1

      I'm positive the lines had ice in them.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +2

      if water seems to be moving on pump 1 or circ pump then change the sensors.

    • @nunzio1747
      @nunzio1747 2 ปีที่แล้ว +1

      Thank you!

  • @laurathrockmorton5415
    @laurathrockmorton5415 7 หลายเดือนก่อน +1

    I have balboa rs101. What if no power to heater? Pump running ok. No error codes heating light on and just replaced element. Thinking board but what relays control heater? Pulled board no burn marks. Possible relay??? Please help. 120v coming in

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  7 หลายเดือนก่อน +1

      Unplug the heater element cord from the board and test the plug on the board itself. You have 3 spots, only test 2 of them (not the one close to the green ground wire). You should get 120V. If not, Its the board.

  • @matthewshelton1403
    @matthewshelton1403 ปีที่แล้ว +2

    Great Video!
    I have the same heating element in my 2005 marquis hideaway spa.
    I have no voltage going to the heating element through those two copper straps.
    Does this mean that my heating element is bad?
    I figured when the “heating” light was on, I’d get voltage to the heating element regardless if the element is working or not.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  ปีที่แล้ว +2

      99 percent of the time, it's the element. Still could be the relay, but don't think so because that normally will trip the breaker. Change the element first

    • @matthewshelton1403
      @matthewshelton1403 ปีที่แล้ว

      @@VIPPoolsandSpas thank you! I ordered one and will give it a try!

    • @ericsvenpladsen9499
      @ericsvenpladsen9499 ปีที่แล้ว +2

      @@matthewshelton1403 Did the new element fix your spa heating problem?

    • @matthewshelton1403
      @matthewshelton1403 ปีที่แล้ว +1

      @@ericsvenpladsen9499 it did! Thank you!

    • @ericsvenpladsen9499
      @ericsvenpladsen9499 ปีที่แล้ว +1

      @@matthewshelton1403 Thanks for the reply!

  • @cmf71
    @cmf71 ปีที่แล้ว +1

    Thanks for the info, im dam sure its my element. I have a balboa vs501z. Which element should i buy?

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  ปีที่แล้ว +2

      The information on what element you need will be on the heater tube.

    • @cmf71
      @cmf71 ปีที่แล้ว +1

      @@VIPPoolsandSpas thanks a lot

  • @SmolMothman
    @SmolMothman 3 ปีที่แล้ว +1

    hey if the element is ohms out but you're not getting 120v does that mean the boards bad? the screen keeps just blinking 104 and not going to any temperature. almost like a thermostat when it won't click. and then when i hold the jet button down and let go it will scroll through f1-f8 by itself. also, the light button on the control won't click on, but i can get the light to flash when i turn on the second dip switch.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  3 ปีที่แล้ว +1

      Unplug the topside and see what it does. Should come on. Question. Does your topside look beat up or the Stricker cracked at all?

    • @SmolMothman
      @SmolMothman 3 ปีที่แล้ว +1

      @@VIPPoolsandSpas if i unplug the topside i will get 120 at the element is what your saying? and it is not cracked but i just pulled the board and as i was putting it back in a realized there is a small amount of blue corrosion in the plug for the topside on the board

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  3 ปีที่แล้ว +1

      @@SmolMothman what spa pack do you have?

    • @SmolMothman
      @SmolMothman 3 ปีที่แล้ว +1

      @@VIPPoolsandSpas so i put the board back on the LED light started to blink but i couldnt get it to go through diffrent light mods. before i cleaned the corrosion off it wouldnt do that at all. then the control started to do what it did before. it wont stop scrolling up. so it will scroll the tempature back up to 104 when you turn it down. and it will scroll up through f1-f8. it seems to be stuck srolling up. there was small amount of blue corrotion where the topside plugs into the board.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  3 ปีที่แล้ว +2

      @@SmolMothman topside has low voltage. you don't test that. what spa pack do you have?

  • @kerrahfoster544
    @kerrahfoster544 2 ปีที่แล้ว +1

    Hello I have a balboa and we are not getting any power to the hot tub. We replaced heating element a few months ago is been ok. Checked all fuses were good .. nothing.. replaced the mother board and now top side and still nothing.. not tripping breakers, power going into spa pack but nothing..about to order a new tub. This is a Dr wellness x-3 model..any ideas on what else causes no power? ..we tried disconnecting items no pumps, no power to topside at all..

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +1

      When you say no power. Does that mean nothing on the topside?

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +1

      Does anything run on its own ? Do you have any clicks from the spa pack?

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +1

      Another question. How long have you had the tub for? was it running in the same spot before this issue?

  • @robertfiloramo2488
    @robertfiloramo2488 2 ปีที่แล้ว +1

    How do I determine which sensor is bad if any on the Balboa 30344 sensors?

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +1

      Is there an error code in the topside? If no, have to change both.

  • @spencercombs
    @spencercombs 2 ปีที่แล้ว +1

    Any idea if a stuck relay could be responsible for an OHS code. Tub is very cool but reads 110. looked for flow problems, removed M7 temp sensors, still pauses with an OHS code. Older Down East Spa, MS2000 board

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +1

      What spa pack do you have? Might be a sensor issue. But could be a board issue also.

    • @spencercombs
      @spencercombs 2 ปีที่แล้ว +1

      @@VIPPoolsandSpas EL2000 Mach2, I have pulled the sensors and restarted temp obviously doesn't show anymore but still cycles on and pff with an OHS code

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +1

      @@spencercombs check all the wiring on the sensors and topside (gray in color). dirty filter or somehow clogged filter pipe. (remove filter first). water too low in tub maybe?

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +1

      @@spencercombs is this a new tub installed or has it been there for awhile with no issues?

    • @spencercombs
      @spencercombs 2 ปีที่แล้ว +1

      @@VIPPoolsandSpas Been there for a while, had this issue a year ago but resolved itself with several off/on's tapped on the relays, etc. wiring seems to be good, checked all of it, filter is clean, also ran it without filter to eliminate flow issues, purged lower pipes near pumps,

  • @neilfigueredo7041
    @neilfigueredo7041 2 ปีที่แล้ว +1

    I have a Viking Spa model PSL AURI serial number 16022000 No power to heater? No sure if it's a board issue? Fuse seams ok. sensor issue? Relay issue. No codes, heat light comes on. but no power to heater. How can I check the relay??

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +1

      Any error codes? Does all the pumps work as normal? When you mean "no Power" , it that no volts?

  • @mannydiaz8842
    @mannydiaz8842 17 วันที่ผ่านมา +1

    Hello, I’m getting an HH code. I’m thinking it’s the two sensors. Any advice would be appreciated thank you.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  17 วันที่ผ่านมา +1

      2 things. Make sure that the pump pushing the water thru the heater is working. Make sure to pull the filters. There should be an error code before the HH. It still could be a sensor issue but other things will make the code come up.

  • @zodmanny
    @zodmanny 2 ปีที่แล้ว +1

    I have replaced the 5.5kw heater element and it’s still not heating. No codes. Pumps are both working. Checked the ohms of the old element and i read 11 ohms. Still no volts at the 2 leads of the new element. The board look ok and the voltage at the board is 120v and 240v.The model number is MXBP501X. Should i check the relay?

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +1

      Could be one of the heater relays. Can take it apart and look behind the circuit board to see any burn marks. Thats if you cant see anything from the front. Also, when you when the power off and then back on can you hear any clicks from the spa pack?

    • @zodmanny
      @zodmanny 2 ปีที่แล้ว +1

      @@VIPPoolsandSpas Thank you for the quick response and your knowledge, I was alone at home today so nobody to put the power back on to hear any relays clicks. I did remove the board and i didn't saw any clear evidence. What should i do from there?
      Here some pictures: drive.google.com/drive/folders/1cJArsUkaisZmSFiO8enS1uGLfHn7kRwn?usp=sharing

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +1

      A electronics guy or Cell Phone repair guy can test the board and maybe fix it for you. Just have to find someone in your area. It might be one of the relays with the white sticker on them.

  • @bsautner1
    @bsautner1 2 ปีที่แล้ว

    Thanks. Knowing the copper leads to the heating element should read 240 when heating helped me out of a pickle. Finally see the temp going back up.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +1

      Glad it helped. Make sure to like and subscribe.

    • @ericsvenpladsen9499
      @ericsvenpladsen9499 ปีที่แล้ว +1

      Did the new element fix your spa heating problem? Or was there a different solution?

    • @bsautner1
      @bsautner1 ปีที่แล้ว +2

      @@ericsvenpladsen9499 My first Balboa control system came pre-wired for 240v and my replacement was wired for 120v. There are all of these jumper wires I needed to understand to ensure everything was gettting 240v. In my case the heater was only getting 120v because the jumper config wasn't using both black and red hot wires. I also needed the right dip switch settings for my pump so it new to run the heater at the right times.

  • @martynmartin6797
    @martynmartin6797 11 หลายเดือนก่อน +1

    Changed out the element after showing no voltage between the heater prongs. Still no
    Voltage. Board issue?

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  11 หลายเดือนก่อน +1

      If it shows no volts when its calling for heat, then it's a relay issue. Most likely. If the element had volts but it didnt heat, change the element.

  • @brettmaccannell6526
    @brettmaccannell6526 3 ปีที่แล้ว +2

    Have Balboa BP. Pumps work, no SL code currently. Couple weeks ago it turned off a couple times Bc it got too hot. 8 years old. No OHMS (O.L) between element leads. No voltage between element leads. 240v to unit. Tested power getting to unit and top side. Any ideas?

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  3 ปีที่แล้ว +1

      Change the heater element. See our video on testing volts and amps. Also, See any burnt or melted spots on the circuit board. Look at the right bottom of the transformer. That's the normal spot for the BP.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  3 ปีที่แล้ว +1

      Another thing to check is.....have someone help you with this next step. Turn power off, hold the leads to the element to test volts. While holding the meter at the leads, have someone turn the power back on. Listen for the relay click and see if volts come thru the element. That same person that turned the power on comes to the tub and sets temp up to 104.... Because the BP will be going thru it's programming and needs to start the circ pump sooner, so your not sitting there for 5mins waiting to see if the volts go thru the element.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  3 ปีที่แล้ว +1

      Another thing. Make sure you pull the filters when you test the heater element volts and amps. Amps only if you get volts first

    • @brettmaccannell6526
      @brettmaccannell6526 3 ปีที่แล้ว +2

      This is amazing feedback. PS - searched for 2 days and finally found your videos and things actually make sense!

    • @brettmaccannell6526
      @brettmaccannell6526 3 ปีที่แล้ว +1

      @@VIPPoolsandSpas the heater element is the long tube roughly 135$ on amazon. Is that which part you mean?

  • @justinmcleod5256
    @justinmcleod5256 ปีที่แล้ว

    Hello there I have a vs300fl4 balboa system. I have done your ohm test and amp test. I get 15.2 ohms on the test and I get an audible click and unit draws 18.5 amps for a second then it goes back to just reading the amps on the pump. I do not have 240 volts across the post on the heater but I do have 120v to ground on each side. Red and black main feed 246 volts. Red to white 123 black to white 123

    • @justinmcleod5256
      @justinmcleod5256 ปีที่แล้ว

      Also no codes given during cycle.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  ปีที่แล้ว

      What's the hot tub doing or not doing?

    • @justinmcleod5256
      @justinmcleod5256 ปีที่แล้ว +1

      @@VIPPoolsandSpas it's doing everything I ask it to do but heat the water up.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  ปีที่แล้ว +1

      @@justinmcleod5256 Change the heater element.

  • @richardshort5406
    @richardshort5406 28 วันที่ผ่านมา +1

    I have a Balboa VS511Z, The heat light doesn’t come on, I have 120V on element, Heating element in circuit shows 10 Ohms. Can the heating element cause this no-heat condition?

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  28 วันที่ผ่านมา

      Yes

    • @richardshort5406
      @richardshort5406 28 วันที่ผ่านมา +1

      @@VIPPoolsandSpas Awesome I was hoping you would say that

  • @bbull789
    @bbull789 ปีที่แล้ว +1

    Thank you for your video. I went to check my heater element and found the pump was out and had to replace the pump first. Now I am on to my heater element and am watching your video closely, but I have run into an issue that is not covered in the video.
    - I tested the Ohms and they are about 10.9 (I have a 5.5 kW element)
    - I tested the continuity and it is good with the same reading
    - I tested the voltage and it is 0, however I disconnected the J46 heater connector and tested voltage at the pins.
    - Pin voltage is 23.18 on the two outside pins and 123.8 from one outside pin to the center pin.
    Does that mean my connector is bad? It would seem that if the relay is bad that the voltage would be 0 on all pins; am i correct?
    Thank you for any help you can provide.
    Regards,
    Brian

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  ปีที่แล้ว +1

      What are the volts at J100 and J101 ? What is the volts coming into the spa pack (red and white) (black and white)? AND. Is pump 1 running/circ pump running?

    • @bbull789
      @bbull789 ปีที่แล้ว +1

      @@VIPPoolsandSpas Volts coming in are 240 across black and red and 120 across white and either black or red. Pump is running.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  ปีที่แล้ว +1

      @@bbull789 J100 and J101 ? Volts? AND is pump 1 running on its own?

    • @bbull789
      @bbull789 ปีที่แล้ว +1

      @@VIPPoolsandSpas 125.2 Volts on each

    • @bbull789
      @bbull789 ปีที่แล้ว +1

      @@VIPPoolsandSpas Yes…pump 1 is running on its own.

  • @aaronjonke5704
    @aaronjonke5704 2 ปีที่แล้ว +1

    I have no power at the heating element. Everything else checks fine. It is still producing some heat and keeping the spa at 80°. Temp settings are correct on the control panel. I was thinking of replacing the heating element. What are your thoughts?

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +1

      Replace the element. The 80 is from the pump heat.

    • @aaronjonke5704
      @aaronjonke5704 2 ปีที่แล้ว +1

      @@VIPPoolsandSpas I forgot about the pump heater! That makes sense. Hey great videos that are super helpful!

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +1

      @@aaronjonke5704 the pump motor heats up to about 80 to 85. So I know when people say there heat is at around 80, it's the heat coming from the motor running

    • @aaronjonke5704
      @aaronjonke5704 2 ปีที่แล้ว +1

      @@VIPPoolsandSpas OK I Replaced the heating element. I still have no electricity on top of the heating element. So now I am looking for some new ideas. All the fuses were working properly. Does this mean there is something wrong with a relay?

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +1

      @@aaronjonke5704 anything showing on the topside? And whats your set temp?

  • @clyde19770
    @clyde19770 ปีที่แล้ว +1

    What if you’re not getting the 240 when touching both heater tabs?

  • @otishills4757
    @otishills4757 3 ปีที่แล้ว +2

    I have a Balboa VS100 that's been configured from 110 to 240. The spa comes on no error codes says it's heating indicator light but doesn't warm up. On the heater from ground to power it's 120 on one post black wire from ground power 120 on other white wire. When measuring white black together there's zero volts. Bad heater or bad circuit board?
    I'm lost...

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  3 ปีที่แล้ว +1

      If your testing the power coming into the spa pack......red/white at 120V....red/black at 240V and black/white at 120V. Was this pack just changed from 120V to 240V ? Was the breakers changed or moved at all?

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  3 ปีที่แล้ว +1

      Also watch video (not my video)....... Converting a Balboa VS100 FROM 110 v to 220v (Russ Washburn). Also make sure that your breaker is set in the breaker box the right way (2 phase). If you didn't do what the video says, you might of blown the spa pack.

    • @otishills4757
      @otishills4757 3 ปีที่แล้ว +1

      Yes on the power coming into the spa pack there is 240 and 120 on the wires you mentioned. I haven't tested the breaker box it was wired in by a certified electrician so I assumed it was good.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  3 ปีที่แล้ว +1

      @@otishills4757 If you can test the element itself, test the 2 leads and you should get 240V. If you get 240v, then turn power off and test ohms. See our video th-cam.com/video/gU-GgXnVeOU/w-d-xo.html

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  3 ปีที่แล้ว +1

      @@otishills4757 or th-cam.com/video/eu4sRppY4fU/w-d-xo.html

  • @stubla7177
    @stubla7177 10 หลายเดือนก่อน +1

    Hello, hopes you can help, i have a VS100 just converted to 240v followed spaberry inst. And you tube video so that's good. Heater does nothing tub says it is. Get 15 ohm at heater unplugged. Gets 120v each prong when testing to neutral at heater when plugged in. Unplug heater and test plugs on board White=1.5V black= 120v test both together with heater plugged in get 0V. Heater is 4 months old. Board is 10 years.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  10 หลายเดือนก่อน +1

      Turn power OFF. J11 - make sure it is ON. (jump it across both pins). Change the dipswitch. #10 to OFF. Take white jumper wire off (J28 and J57). hope you did that before turning. lol. Make sure to read the instructions on the back of the door of the pack.

    • @stubla7177
      @stubla7177 10 หลายเดือนก่อน +1

      ​@VIPPoolsandSpas yes I did all of that before turning it on as per their manual. 0 amp on both wires at heater. The heat must be what the pump is making.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  10 หลายเดือนก่อน +1

      Just read over the first message you sent. Where's the red wire? Whats the volts coming into the pack?

    • @stubla7177
      @stubla7177 10 หลายเดือนก่อน +1

      Red wire coming in? 4:50 is on the bottom, black in middle white is second from top

    • @stubla7177
      @stubla7177 10 หลายเดือนก่อน +1

      ​@@VIPPoolsandSpasvoltage coming in is 246. Same at gfci. White output to heater is 1.5 black output is 123. Amp draw on both is 0 when heater is plugged in

  • @carlosemilio3308
    @carlosemilio3308 2 ปีที่แล้ว +1

    Hello if you can help I would appreciate each time í plug back the connector into the switch the main terminal terns off in the house this connector his for the heater power what can it be thanks

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +1

      Not sure what your asking. Sorry

    • @carlosemilio3308
      @carlosemilio3308 2 ปีที่แล้ว +1

      @@VIPPoolsandSpas my beaker at home is always going down. I disconnected all the conectes in the pot and found the one . Can I send you a video and show you

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +2

      @@carlosemilio3308 put your video on youtube and send me the link. That way the video can be longer and better quality.

    • @carlosemilio3308
      @carlosemilio3308 2 ปีที่แล้ว +1

      @@VIPPoolsandSpas th-cam.com/users/shorts5cGVZS7hWVs?feature=share

    • @carlosemilio1215
      @carlosemilio1215 2 ปีที่แล้ว +1

      @@VIPPoolsandSpas th-cam.com/video/EKdnYdC7r6g/w-d-xo.html

  • @ianstewart4323
    @ianstewart4323 3 ปีที่แล้ว +1

    What is the long circle thing at the bottom called?

  • @MJ7DIRULE
    @MJ7DIRULE ปีที่แล้ว +1

    Hey ive got one for ya, no codes, no restrictions in the system, pump working, new heating element, but no voltage at the heating element. Heating indicator light is on. I tested everything the way shown. Heating element is 10.5 oms. Not heating at all. New sensors as well, no air in system.

  • @Theundisputedtruth
    @Theundisputedtruth 7 หลายเดือนก่อน +1

    I dont have a tester , heating source gets kind of hot no codes why isnt it getting hot ? Pump is running , any help anybody

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  7 หลายเดือนก่อน +1

      Need a meter to find the problem.

  • @ricku4856
    @ricku4856 2 ปีที่แล้ว +1

    Have a Balboa pack with the 240v at the element. Tried 3 new heaters thinking got defective heaters due to lack of packing still no heat. Heat light is on, on control panel. No pressure switch.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +1

      Did you test amps? Any error codes? What's the temp when heat light is on? Is light solid or does it flicker?

    • @ricku4856
      @ricku4856 2 ปีที่แล้ว +1

      @@VIPPoolsandSpas Did not test amps due to it being late and night time. Would rather test that in daylight. No error codes. Temp is currently 74 and been at that for last 3-4 hours. Light is on solid

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +1

      @@ricku4856 test the amps first. Sounds to be the relay.

    • @ricku4856
      @ricku4856 2 ปีที่แล้ว +1

      @@VIPPoolsandSpas Which relay?

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +1

      @@ricku4856 depends on the balboa spa pack you have. but there would be 2. one for the right lead going the the element and one going the the left. normally you would see them burnt or melted a bit. sometimes can only see it from the back of the board. Test the element for amps first.

  • @lawrencegregory9644
    @lawrencegregory9644 2 ปีที่แล้ว

    Have the same problem no heat. Light is on and calling for heat. Voltage is coming in to power our correct. Voltage to ground on each heater terminal separately is 120v. Voltage across both heater terminals is around 9v. Pull board and check for burns? Thanks.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว

      Check the amps at the heater element or look for those burn marks front and back of circuit board.

    • @lawrencegregory9644
      @lawrencegregory9644 2 ปีที่แล้ว

      Thanks for the reply. I'm picking up an amp meter tomorrow. There is a burn mark on the board near the right terminal Where the copper strap bolts on.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว

      @@lawrencegregory9644 no need for the amp meter then. Can you send me a picture of that to info@vippools.ca just to confirm what I think it is.

    • @lawrencegregory9644
      @lawrencegregory9644 2 ปีที่แล้ว

      Ok. I Sent the pic. Thanks.

    • @lawrencegregory9644
      @lawrencegregory9644 2 ปีที่แล้ว

      What do you think? Stuck Relay? Thanks.

  • @heathermercer8528
    @heathermercer8528 ปีที่แล้ว +1

    I have a Balboa pack Changed heater Only heating to 82゚ Any ideas of what could be wrong

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  ปีที่แล้ว +1

      The 82 is just from the motor heat. You will have to test the heater element for volts and maybe the amps.

    • @heathermercer8528
      @heathermercer8528 ปีที่แล้ว +1

      Now it has moved up to 85 Any ideas as to what I can do

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  ปีที่แล้ว +1

      @@heathermercer8528 test the heater element and the amps. When the display shows around 85, up or down it's from the motor heat and not the heater element.

  • @larryjohnson924
    @larryjohnson924 3 ปีที่แล้ว +1

    I have a Balboa LPI501ST PN 56704 Had a new 2nd pump installed which works but the Expander board is faulty. The Heater is not working as prior to the 2nd pump replace. I checked all the fuses and the heater is not working. I replaced the heater and still not working.
    Power to unit is OK but no power is at the heater terminals. Am I destined for a new circuit board? any options to see if that is the case without totally taking the circuit board out?

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  3 ปีที่แล้ว +1

      Whats the Balboa type? BP? Need the Model number at the top of the spa pack.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  3 ปีที่แล้ว +1

      Do these tests. th-cam.com/video/eu4sRppY4fU/w-d-xo.html
      Or This one - th-cam.com/video/zoF2q0UEJx4/w-d-xo.html
      We also have a new video coming out in 10mins. Its a MAAX Swimspa with a balboa BP spa pack with the connection and relay fried.

    • @larryjohnson924
      @larryjohnson924 3 ปีที่แล้ว +1

      @@VIPPoolsandSpas Balboa Water Group Model Number LPI501ST Part number 56704
      240V 60HZ 48Amp

    • @larryjohnson924
      @larryjohnson924 3 ปีที่แล้ว +1

      I need a digital meter and get back to you tomorrow

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  3 ปีที่แล้ว +1

      @@larryjohnson924 it will give you a better understanding of whats going on and where to check next. Let me know what you find.

  • @dmilburn39
    @dmilburn39 6 หลายเดือนก่อน +1

    Have ran all these steps I have no code on my display and tub still won't heat. Board is fairly new with no visible damage. Have changed the coil already as that had gone but now it still won't heat. It does heat sporadically but once it gets to temp it won't heat and temp drops significantly.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  6 หลายเดือนก่อน +1

      Whats the volts and amps on the heater element?

  • @WilliamDaniel3-mh6on
    @WilliamDaniel3-mh6on ปีที่แล้ว +1

    I got a Brand New heating everything's working in it I got brand new Bible and I'm having trouble getting it to heat up the tub and I cannot figure out what it is help I need help

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  ปีที่แล้ว +1

      ? Can you rewrite this? Please.

    • @WilliamDaniel3-mh6on
      @WilliamDaniel3-mh6on ปีที่แล้ว +1

      @@VIPPoolsandSpas I bought a brand new computer system and it still won't I heat up don't know what else to do everything in it runs works

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  ปีที่แล้ว +1

      @@WilliamDaniel3-mh6on You bought a brand new spa pack? With a new topside or new one? What system (spa pack did you put in? Is the hot tub 240V or around that?

    • @WilliamDaniel3-mh6on
      @WilliamDaniel3-mh6on ปีที่แล้ว +1

      @@VIPPoolsandSpas new switches knew everything and it's 110 it's a plug-in one a regular outlet plug and the system everything is brand new

    • @WilliamDaniel3-mh6on
      @WilliamDaniel3-mh6on ปีที่แล้ว +1

      Balboa VS501x

  • @b2tl-gamingchannel319
    @b2tl-gamingchannel319 7 หลายเดือนก่อน +2

    Replaced heater element, replaced relay, still no heat. Relay closes volts go to 3 then back to zero when the relay opens back up. Vs300fl5 board.

    • @b2tl-gamingchannel319
      @b2tl-gamingchannel319 7 หลายเดือนก่อน +1

      I should add, checked all fuses as well, no shorts on back of board. Tired of wasting time with this and definitely don't want to spend $500 for a simple fix.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  7 หลายเดือนก่อน

      @@b2tl-gamingchannel319 don't know what issue you had before, what error codes if any and not sure the tests you have done. Follow the videos that may apply to your situation.

  • @robbrollinger2856
    @robbrollinger2856 2 ปีที่แล้ว

    No codes. Pumps are both working. I have a brand new heater that I just installed and it’s still not heating. The light comes on the top control panel like it’s calling for heat but still nothing. How do I check if the board might be the culprit?

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว

      Test volts first at the 2 leads of the element. If you get around 240v, then test the AMPS. 4kw element should be around 23amps. A 5.5kw element should be around 27amps. If no volts, dont bother testing amps. it would be the element. If no error codes come up and you have around 240v, test the element amps. Let me know how that goes. Get a meter with the "clamp" for testing amps. Set it to AC.

    • @robbrollinger2856
      @robbrollinger2856 2 ปีที่แล้ว

      Update: When it first clicks and calls for heat the light blinks very quickly and then after a few minutes it will stop and be a solid light. The heater is brand new so I have a hard time believing that it is bad, but I guess it’s possible. I disconnected the leads to the heater, turned power on and had zero volts. Then both pumps kicked on and then I had 240v??? I turned power off, reconnected the leads and the same thing happened. Zero volts until both pumps kicked on and then I had 240. I’m thoroughly confused, haha.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +1

      @@robbrollinger2856 Pump One engages the heater element. If pump one doesn't come on or there's an issue, an error code will come up. The blinking is just programming and it's looking for problems before calling for heat.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  2 ปีที่แล้ว +1

      @@robbrollinger2856 Remember. If you have volts at any time after the start up at the heater element and its not heating up test the amps to confirm if its a board or element issue. I'm still saying it's an element. But the only way to confirm is the amps test.

    • @robbrollinger2856
      @robbrollinger2856 2 ปีที่แล้ว

      Thank you so much for sharing your knowledge here.
      I’ll need to see if my meter will test amps 🤷🏼‍♂️. I’ll keep checking. I didn’t find your videos until after I ordered and installed the new heater tube. I was kinda tails shot in the dark.

  • @johnrodgers4884
    @johnrodgers4884 ปีที่แล้ว +1

    system runs but no heat,message out of sync? any suggestions

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  ปีที่แล้ว +1

      Whats the spa pack you have? Name of tub? Error code showing? If it's saying out of sync, it's the heat sensor and high limit not communicating with each other.

  • @bradclott8027
    @bradclott8027 ปีที่แล้ว +1

    Hey. Love the video. Balboa VS500Z stopped heating. Board is 1.5yrs old. Could not find multimeter. Replaced heating element and relays. Did the relay bypass straight to heating tube. Still no heat. Found meter. Just watched this. I have 120v Neutral to Black, and 120v neutral to red. I have 0 volts between black and red! Is it the the power terminal block? Its the newer balboa style not old. (old board had that and burnt up) Thanks VIP!

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  ปีที่แล้ว +2

      If your testing volts coming into the spa pack and your getting those readings it will be an issue at the GFCI breaker.

  • @douggreen3462
    @douggreen3462 ปีที่แล้ว +1

    No power to elements? What then?

  • @VIPPoolsandSpas
    @VIPPoolsandSpas  3 ปีที่แล้ว +3

    When a balboa spa pack isn't heating up, most likely it's the heater element. (even if the heater element Tests OK.)

    • @johnwatson3273
      @johnwatson3273 3 ปีที่แล้ว +1

      I have no power to the heater. Does that mean a new circuit board? BFBP20

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  3 ปีที่แล้ว +1

      @@johnwatson3273 all depends on what spa pack you have. A pressure switch will turn the heater element on. What hot tub is it? And the year?

    • @johnwatson3273
      @johnwatson3273 3 ปีที่แล้ว +1

      @@VIPPoolsandSpas Thx for your response. Its a Bullfrog a900 series. BFBM20 is the control box. I have power to the unit, pumps, all controls function, but testing the power to the heater, the two leads, showed nothing. No voltage. I think its the circuit board. Two other websites I went to concurred with that

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  3 ปีที่แล้ว +1

      It's a Balboa spa pack and has no pressure switch, so it sounds like the relay not turning on. If you know anyone that fixes computers....ask if they work on boards. I think it's just a relay. Look on the board for any melted spots.

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  3 ปีที่แล้ว +1

      Sorry, Was reading other comments at the same time. What's the Set Temp at? What's the Temp Now? will not have voltage if its up to temp.

  • @jimbrohammer3270
    @jimbrohammer3270 ปีที่แล้ว +1

    Why can't you ohm the fuse while it's in place with the power off?

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  ปีที่แล้ว +1

      You could and most times I do. But. Its good to take them out to look over them. It might be burnt that you can't see.

  • @ScottSmith-bo1ns
    @ScottSmith-bo1ns ปีที่แล้ว +1

    balboa heats only up to 86 degrees

    • @VIPPoolsandSpas
      @VIPPoolsandSpas  ปีที่แล้ว +1

      1) make sure that it's not on economy mode. 2) Test the heater element for volts and amps. The heat might only be from the motor running.