- In this video I will walk through the steps you need to take to configure a Balboa Spa Pack. Not all Spa Packs will work "out of the box" with the configuration that you need. In this video, I hope to de-mystify the steps needed to configure your Balboa Spa Pack.
I walk through the DIP switch settings as well as how to set the program setting that you need on your Balboa spa pack to match the setup and kit you are using.
Can I help you with your DIY Hot Tub build? Please get in touch www.buildahottub.com
Want to learn how to build your own DIY Hot Tub - buildahottub.c...
Looking for plans and designs, shop.buildahot...
💡 Looking for plans, designs, custom design & build consultancy…
shop.buildahottub.com
ℹ More information, tips, tricks, info, case studies, “how to” articles…
buildahottub.com
🇺🇸 USA Hot Tub Parts
parts4tubs.com
🇬🇧 UK & EU Hot Tub Parts
parts4tubs.co.uk
If I can help you in any way, please do get in touch
A big thank you. I've got the BP7 with the TP600. Before watching your vid I understood bits n pieces but your video pulled it all together for me. Much obliged.
You are welcome! - thanks for the comment
Many thanks for this video. Had to replace my control kit and the setting when shipped only allowed high speed on pump 2. Between the manual and your video I changed it to the correct setting and now I'm 100% back in business.
Glad I could help Chris - happy hot tubbin' - Andi
Thank You for this video I was tired of trying to call balboa tech support! :)
Excellent video, thank you for making it!
I wish you had a similar video for my new Hydro-Quip controller. I'm getting a headache trying to interpret the printed user manual.
Thanks for a great video.
To confirm; on a swim spa with 4 HS pumps & a heater I would only turn that switch to 'ON' in the switch bank and not each of the options for less high speed pumps below it, correct?
4 HS pumps I hink is the limit on a BP7, they would each have their own on/off button and you would need a keypad that supported this - thanks - Andi
just purchased this balboa BP7 spa pakwith with TP00 topside controller to replace my previous balboa spa pack...this ones slightly newer with more options and i'm having issues figuring out the right settings...i have 2x 1-sp jet pumps, and a circ pump (no blower)...its recongizing the first Jet pump as a 2-speed when i press the button, and Jet 2 isnt getting any power when i press its button...would you be able to tell me what the proper set up for that is?
Question..U seem like you make things really easy.. I had hooked up my pack BP7,,and noticed the ground connection is not located inside the box for the ground?? soo this means I have to leave it out and connect it to the ground lug on the outside of the box THank you
Hi there, thanks a lot for your very helpful videos, I have a Balboa MGS504SZ spa pack, a 2 speed pump (balboa 1023324) and a tropic seas spas topside with 5 buttons. It was working fine and then started tripping, I left it off for quite a long time. Changed the element and now when it starts up the hot tub starts to heat up and then comes up with a HFL fault. It seems to me that the pump only works on high speed and not low speed. I have checked all the relays and they are all okay, thanks in advance for your help, Luke
Thank you for the great video. One question I have is if you are changing your settings and you set dip switch one up, will it tell you which setting it is currently at or will it just start over.
You can cycle through the settings which are on display before you select the one that you are going for. Hope that helps - Andi
sorry for the long comment, I have installed BP7 with a TP500 topside wasn't able to get the 2nd pump(1 sp) to fire(Aux). I was talking with a Tech support forgot to mention that on that pump it's 4 wire (grnd, wht, blk, red) which makes it a 2 speed wire corrct?but pump is 1 sp the wire I have is for a 2 speed but I left the red disconnected will this make a diff for it not firing? I had the 2 sp plug , pluged in pump 1 and the 1 sp cord plugged in pump 2 on expanstion brd wasn't able to get pump 2 (1sp) to fire. Tech thought I should have theTP600 I thought so as well.. but the seller wanted me to send in the entire unit..what a huge inconvenience Tech said i had everything connected correctly. and could be the topside or the expansion brd / or main brd faulty. I started wondering about that 2 sp cord on a 1 sp pump that came off of it. So Im sending back the entire unit in. Geeezz.. Help..
Hi Gary, when that happens, that normally means you have not got the right program mode set on the unit. Out of the box it is in mode 21 that is a dual speed pump only. You would need to change the setup mode to #7 if you have a 2sp pump 1, 1sp pump 2 and a blower - #20 if 2 speed pump1 and 1speed pump 2 no blower - hope that helps - Andi
just trying to get another opinon and you do know what your talking about when I watch your vid Tech said I had everything set correctIy I set it for my config 7 which is pump 1 (2 sp) pump 2 (1sp)& blower my topside only had 1 button for jets pressed once low twice high...but I told the seller and Tech even said I needed the TP600 for the blower as well as showing 2 buttons for jets TP 500 only has one for jets.. but 1 sp pump had a 3 wire on it I had orered 14/4 and didnt know until I started to change them out so.. I put the 14/4 on that pump and taped off the red wire is this ok ?? I forgot to mention this to the tech... >> wil the board recognize it.. coz when I press Aux Nothing...or do I need to put on a 3 wire back on it..If I do.. will it matter what position the wires are in the connector? Tech said it could be topside or expansion board or main brd thats bad ...seller wants me to send the entire package back.. vs the topside to see if that worked..
@@Buildahottub Good Morning thx for your help...everything running except my Air blower I had it on Aux wouldn't fire only two ports left is (J21 Circ) & ( J32 Ozone) will either one of these work??
How did you know which program to put it to? I accidentally changed it and don’t know which to put it back to for my 2 pump system. Right now my main 2 speed pump only has high flow and no low speed for the filter to turn on
Hi Greg, you need to look at the inside of the spa pack cover - there will be a table explaining what combinations the pack supports and then the corresponding numbers. If you have a dual speed pump ignore the first column and then look for a pump 1 and pump 2 column that match what you have plus any blower or ozone etc. Hope that helps - Andi
Thanks!
Hello I have a balboa TS2000. I had to replace the old circuit board because the old one had a bad relay. I put the new circuit board in and the 2 pump and blower does not work but pump 1 and circulation pump does work. I have two pumps and a blower and circulation pump which program number do I need to use to make it work again thanks
Hi Andy
I have a home build and it consists of 1 x 2 speed pump and balboa BP IDX-1 46157_C controller and heater with topside controller TP 500. How can i set/confiure for this set up.
PS i have it on 13amp at the moment and it keeps popping fuses.....Hopoe you can help a hot tub novice.
Hi Andy wonder if you con help with a little advice, i have a Grand Canyon spa, 3 Ha440 pumps Blower and ozone, went out of comision 2 years ago, recently i purchased a Balboa BP8 control pack with top side spa touch mini, all went well with set up and install had to change all the spa pump plugs etc for amp plugs, anyway after restarting PUMP 1 a 2 Speed started at 1st speed, tried to start 2nd speed and it tripped the house breaker, and then would not start at all, Pump 2 single speed dead nothing, pump 3 working perfectly blower working, i examined the pumps and decided i would also replace for new, i installed the new pumps, but got exactly the same result, if i plug pump 2 into pump 3 socket it works so i'm pretty sure its not the pumps.
Hi Tony, i'll be doing a series of videos on the BP8 system soon as Balboa have actually just sent me a unit for my channel. You should be set to Spa Pack to Program #7. If you have not done this it could be the root of your problem. DIP1 up and then you can go into the settings menu on the Spa Touch mini. Check what connectons you have things plugged into - Pump 1 (2 speed) into J9, Pump 2 J14 - pump3 and blower into Expander Board. - hope that helps - Andi
@@Buildahottub hi Andy yes set to number 7 and pump 1 and pump 2 work if I plug them into the pump 3 socket on the expander, they just won't work in pump 1 socket or pump 2 socket I have checked all fuses for continuity and they are ok
@@tonyrfp Could be a bad spa pack Tony, i've seen similar things before where there is just no other explanation - send it back to where you got it under warranty and get a replacement. - Hope that helps Andi
I have a BP7 with TP600 I have also configured mine to 13 setup as well . I just have a 2 speed pump for the jets and a single speed pump for recirculation and heater. I have it set to run on 220volt . I hooked it up filled tub but my circulation pump will not come on I can hear the relay clicking but no circulation can you help thanks
Setup #13 is a circulation pump (plugged into J21) a 2 speed Jet Pump (J9) and a 1 speed jet pump (Expander Board) - also check the voltage that you need for your circulation pump. If it is 115V, J20 needs to go to group 2, if it is 240V then it needs to go to group 4 - Also, check the F7 fuse to make sure it has not blower - hope that helps - Andi
Hi my panel is showing an error code 254, its a balboa swim spa. Its new never used, but did sit up for about 2 years without running
Hi There, sorry about late reply - I would disconnect everything and then turn on the panel. Let it give you lots of errors, then turn off, reconnect and then turn back on - this usually forces a reset. Hope that helps - Andi
Hello, I have a balboa gs510sz and now it is programmed to keep the circulation pump running for 24h. Can I turn it off with the dip switches? Thanks
Hi There, that model only has 24 hour cirulcation. If you turn off DIP9, you then have no circulation pump at all - so unfortunately, it is on 24/7 or off and you will not be able to heat your tub. If you are looking to update, the BP7 is a good model to move to and not too expensive.
@@Buildahottub Hello thanks for the quick response. I might still try to put a timer between the controller and the circulation pump. And programming it so that the pump comes on when the filter cycle and heating starts. Because now the biggest consumption I have on my Jacuzzi is the circulation pump running 24/7.
Hi I have a tp600 topside and my hottub is Bluetooth but I can’t find the bt on my topside can you advise on what I need to do to find the blue tooth please
Hi Mark, I am not aware of the TP600 being BT compatible - you must have another accessory like speakers or a radio that are and they will have the bluetooth module in it that you will need to pair with - there are no options on the TP600 for BT. Hope that helps - Andi
A query… I have a Balboa system with a TP600 top-side. Is it possible to ‘force’ a filter cycle ad-hoc’, or can this only be done by setting up and/or modifying the programmed filter cycle?
Cheers, Jon.
Hi John, pressing jets once and turning on your circulation pump is the same as a filter cycle. The default run time for this is 15 mins. A specific filter cycle can only be set and programmed as far as I know - hope this helps. Andi
Hi. I have a Bullfrog RL spa. I replaced the spa pack BFBP20 which is a Balboa. How do I configure this for 2-2 speed bumps with circulation pump? The Bullfrog controller is is different from Balboa. Thank you. TJ
Hi TJ, you should have on the inside of the spa pack a configuration table - if you want to send me some pics of the topside and also that circuit diagram to andi (a.t) buildahottub.com I will take a look for you and advise - thanks Andi
We have a Sunrise spa model S-104, equip with a TP600 balboa board. Next to the temperature a « T » appears instead of the « F or C », which indicates we are in mode test. The Dip switchs are set as per Sunrise requirements. How do we remove the « T » for test mode?
Hi There, you must have DIP Switch 1 in the ON position, it needs to be OFF - that is the only way to get into the test mode. Hope that helps - Andi
I have a standard balboa BP501 spa pack I recently installed.. put the pins exactly as the unit it replaced however the tub seems to be running constantly now. Any tips on what to adjust?
Hi Robert, thanks for the message. This sounds to me like the program setting that it shipped with does not match the kit that you have plugged into it. - have a read of this article on my site about selecting the correct setup mode - drop me an email if you are still stuck - buildahottub.com/hot-tub-wiring-explained/#Hot_Tub_Wiring_-_Configuring_a_Balboa_Spa_Pack
FYI there is a typo in URL in video description
Thanks Chris!
Hola tengo un spa con sistema ms1600 número 55240 necesito configurar el bank switch. Me podrías ayudar con eso por favor
+haibert vergara quizas, este es un sistema que nunca he utilizado - que necesitas configurar? El “bank switch” que es?- lo siento este no puedo traducir- si me envias un email a andi (aroba) buildahottub.com con mas detailles intentare a ayudarle usted - explica tambien por que necesita usted configuararlo- si ha cambiado alguna componente por ejemplo - tambien dentro de la caja hay un dibujo del sistema electronico- mandame un photo de esta tambien - gracias- Andi