  • @jameswarren4747
    @jameswarren4747 2 หลายเดือนก่อน +1

    Wow Kevin, didn't expect the video to be based off of my question. That was amazing brother. Very helpful. Machine is disassembled at the moment, but last try was 50° on the left and 40° on the right. I want to see if I can get a tech to put gages on the compressor to make sure freon doesn't have a leak. Solenoids have a strong magnetic pull, and the only leak I have is from the faucet seal. Gonna download the manual and will keep you updated. I greatly appreciate you Sir, and the helpful video. Blessings
    *edit* I may hold off on freon test since it does get down to 40° on one side. I'll try to email you some pictures so you can tell me if you see any visual issues.

    • @latcommercialrepair
      @latcommercialrepair  2 หลายเดือนก่อน +1

      Hey James, I'm glad this was helpful . It is possible that the machine could be low on refrigerant but I would check the torque/ temp readings without the hoppers on and see if you getting between 0 to 4 on the torque on both sides. If your not you will want to replace your shaft assemblies and a PM kit and then see if you start getting a better freeze down . I not then you will then need to see about having a tech test your system for a refrigerant leak. Keep me posted on your progress Brother . Thanks for watching!