- 267
- 83 430
Learn A Trade ( Commercial Equipment Repair)
United States
เข้าร่วมเมื่อ 30 ก.ค. 2014
COMMERCIAL FOOD EQUIPMENT TECHNICIAN TRAINING
Become a certified service technician on commercial food equipment.
Learn the basics of commercial food equipment repair.
Learn to become self-employed once you learn the basics.
Encourage military veterans and all seeking training.
View my Turbo Chef Oven Repair Playlist: 👉 th-cam.com/play/PL5mvZNmpSVXFzAimp3uEYTYXTkTvq21fR.html&si=o13c93Nfyw6qNKW8
Send your requests or suggestions to: ➡️➡️➡️ info@learnatrade.online
👇
www.learnatrade.online
👇
Follow on Instagram:
learnatrade101#
👇
Follow on Facebook:
61560662302906/
👇
Become a Training Member at:
www.learnatrade.online/training-membership-signup
👇
Service Manual Library:
www.learnatrade.online/service-manual-library
Become a certified service technician on commercial food equipment.
Learn the basics of commercial food equipment repair.
Learn to become self-employed once you learn the basics.
Encourage military veterans and all seeking training.
View my Turbo Chef Oven Repair Playlist: 👉 th-cam.com/play/PL5mvZNmpSVXFzAimp3uEYTYXTkTvq21fR.html&si=o13c93Nfyw6qNKW8
Send your requests or suggestions to: ➡️➡️➡️ info@learnatrade.online
👇
www.learnatrade.online
👇
Follow on Instagram:
learnatrade101#
👇
Follow on Facebook:
61560662302906/
👇
Become a Training Member at:
www.learnatrade.online/training-membership-signup
👇
Service Manual Library:
www.learnatrade.online/service-manual-library
Bunn Ultra NX Slushy Machine Repair (Control Board & Refrigeration Coil Replacement)
Join this channel to get access to perks:
th-cam.com/channels/FIWnoCs9snc7V0_eHmfzeA.htmljoin
This channel is intended to educate those interested in working in the HVAC and Refrigeration trade. We will offer educational training resources , actual onsite repair videos to help those watching see some of the work and tools involved. We will share the theory involved in the trade along with interviews of industry professional. We feel that this channel will help those in the industry already and those looking to get into the industry!
In this video I will go over the steps for replacing the control board and the refrigeration coil and why these were necessary to repair a Bunn Ultra NX machine that was not freezing on one side. Thank you for watching!
Helpful Links:
👇
Bunn Tech Support Line: ➡️➡️ (800) 286-6070 or ➡️➡️ commercial.bunn.com/help
👇
Visit our website: ➡️➡️ www.learnatrade.online
#training #refrigerationtech #commercial #slurpee #bunn #learnatrade #newtocommercial
th-cam.com/channels/FIWnoCs9snc7V0_eHmfzeA.htmljoin
This channel is intended to educate those interested in working in the HVAC and Refrigeration trade. We will offer educational training resources , actual onsite repair videos to help those watching see some of the work and tools involved. We will share the theory involved in the trade along with interviews of industry professional. We feel that this channel will help those in the industry already and those looking to get into the industry!
In this video I will go over the steps for replacing the control board and the refrigeration coil and why these were necessary to repair a Bunn Ultra NX machine that was not freezing on one side. Thank you for watching!
Helpful Links:
👇
Bunn Tech Support Line: ➡️➡️ (800) 286-6070 or ➡️➡️ commercial.bunn.com/help
👇
Visit our website: ➡️➡️ www.learnatrade.online
#training #refrigerationtech #commercial #slurpee #bunn #learnatrade #newtocommercial
มุมมอง: 43
วีดีโอ
FBD 56 Series Frozen Beverage Dispenser Training (Upper & Lower Power Boards)
มุมมอง 5112 ชั่วโมงที่ผ่านมา
Join this channel to get access to perks: th-cam.com/channels/FIWnoCs9snc7V0_eHmfzeA.htmljoin This channel is intended to educate those interested in working in the HVAC and Refrigeration trade. We will offer educational training resources, actual onsite repair videos to help those watching see some of the work and tools involved. We will share the theory involved in the trade along with interv...
Wilbur Curtis Coffee Brewer Seal Kit Replacement
มุมมอง 2716 ชั่วโมงที่ผ่านมา
Join this channel to get access to perks: th-cam.com/channels/FIWnoCs9snc7V0_eHmfzeA.htmljoin This channel is intended to educate those interested in working in the HVAC and Refrigeration trade. We will offer educational training resources , actual onsite repair videos to help those watching see some of the work and tools involved. We will share the theory involved in the trade along with inter...
Cornelius Flavor Fusion Ice Chute Replacement
มุมมอง 74วันที่ผ่านมา
Join this channel to get access to perks: th-cam.com/channels/FIWnoCs9snc7V0_eHmfzeA.htmljoin This channel is intended to educate those interested in working in the HVAC and Refrigeration trade. We will offer educational training resources, actual onsite repair videos to help those watching see some of the work and tools involved. We will share the theory involved in the trade along with interv...
Cornelius Drop-In Line Set Replacement
มุมมอง 368วันที่ผ่านมา
Join this channel to get access to perks: th-cam.com/channels/FIWnoCs9snc7V0_eHmfzeA.htmljoin This channel is intended to educate those interested in working in the HVAC and Refrigeration trade. We will offer educational training resources, actual onsite repair videos to help those watching see some of the work and tools involved. We will share the theory involved in the trade along with interv...
FBD 56X SERIES TRAINING (Scraping & Beating System)
มุมมอง 4514 วันที่ผ่านมา
Watch this video for an overview on the FBD 56 Series scrapping and beating system. This video will give you a better understanding of the components and operations within a Slurpee barrel. Thank you for watching! Helpful Links: 👇 FBD Tech Support: ➡️ www.fbdfrozen.com/sales-support/customer-service-and-technical-support?section=technical_support FBD Service Manual: ➡️ www.learnatrade.online/_d...
L.A.T Commercial Equipment Repair Weekly Review (Ep. 5) Turbo Chef & Ice Maker Review
มุมมอง 6714 วันที่ผ่านมา
Join this channel to get access to perks: th-cam.com/channels/FIWnoCs9snc7V0_eHmfzeA.htmljoin This channel is intended to educate those interested in working in the HVAC and Refrigeration trade. We will offer educational training resources , actual onsite repair videos to help those watching see some of the work and tools involved. We will share the theory involved in the trade along with inter...
L.A.T Commercial Equipment Repair Weekly Review (Ep. 4)
มุมมอง 5821 วันที่ผ่านมา
Join this channel to get access to perks: th-cam.com/channels/FIWnoCs9snc7V0_eHmfzeA.htmljoin This channel is intended to educate those interested in working in the HVAC and Refrigeration trade. We will offer educational training resources, actual onsite repair videos to help those watching see some of the work and tools involved. We will share the theory involved in the trade along with interv...
Turbo Chef Field Service Announcement (Relay Board)
มุมมอง 7828 วันที่ผ่านมา
Join this channel to get access to perks: th-cam.com/channels/FIWnoCs9snc7V0_eHmfzeA.htmljoin This channel is intended to educate those interested in working in the HVAC and Refrigeration trade. We will offer educational training resources, actual onsite repair videos to help those watching see some of the work and tools involved. We will share the theory involved in the trade along with interv...
How to Select a TXV for a Particular Application
มุมมอง 2528 วันที่ผ่านมา
Join this channel to get access to perks:➡️➡️ th-cam.com/channels/FIWnoCs9snc7V0_eHmfzeA.htmljoin This channel is intended to educate those interested in working in the HVAC and Refrigeration trade. We will offer educational training resources, actual onsite repair videos to help those watching see some of the work and tools involved. We will share the theory involved in the trade along with in...
FBD Solution Mixing Module
มุมมอง 3828 วันที่ผ่านมา
This video lesson will go over the components and operation of the FBD Solution Mixing Module. Thank you for watching! #training #commercial #brewingsystem #sodafountainmachine #kitchenequipment #commercialequipment #fbd
Winter Work Glove Product Review
มุมมอง 6328 วันที่ผ่านมา
I wanted to share a product review on a pair of Schwer winter work gloves. Check out the video to find out the outcome. Thank you for watching! #training #review
Wishing You All Happy Holidays!
มุมมอง 21หลายเดือนก่อน
Join this channel to get access to perks: th-cam.com/channels/FIWnoCs9snc7V0_eHmfzeA.htmljoin This channel is intended to educate those interested in working in the HVAC and Refrigeration trade. We will offer educational training resources , actual onsite repair videos to help those watching see some of the work and tools involved. We will share the theory involved in the trade along with inter...
How to Test a High Voltage Diode
มุมมอง 100หลายเดือนก่อน
Join this channel to get access to perks: th-cam.com/channels/FIWnoCs9snc7V0_eHmfzeA.htmljoin This channel is intended to educate those interested in working in the HVAC and Refrigeration trade. We will offer educational training resources, actual onsite repair videos to help those watching see some of the work and tools involved. We will share the theory involved in the trade along with interv...
Turbo Chef Oven Repair (Relay Board Replacement)
มุมมอง 169หลายเดือนก่อน
Turbo Chef Oven Repair (Relay Board Replacement)
L.A.T. Commercial Equipment Repair Weekly Review (Ep. 3)
มุมมอง 132หลายเดือนก่อน
L.A.T. Commercial Equipment Repair Weekly Review (Ep. 3)
How to Prepare and Serve Chili Cheese Sauces (Learn & Serve)
มุมมอง 732 หลายเดือนก่อน
How to Prepare and Serve Chili Cheese Sauces (Learn & Serve)
HVACR Service Tech Tips (Service Valve)
มุมมอง 302 หลายเดือนก่อน
HVACR Service Tech Tips (Service Valve)
How to Repair a Leaking FBD Dispense Nozzle
มุมมอง 872 หลายเดือนก่อน
How to Repair a Leaking FBD Dispense Nozzle
FBD Slurpee Machine Repair and Diagnosis
มุมมอง 952 หลายเดือนก่อน
FBD Slurpee Machine Repair and Diagnosis
Tech Talk with Learn A Trade (Commercial Equipment Q & A)
มุมมอง 732 หลายเดือนก่อน
Tech Talk with Learn A Trade (Commercial Equipment Q & A)
Tech Talk with Learn A Trade (Bunn JDF-2S Q&A)
มุมมอง 562 หลายเดือนก่อน
Tech Talk with Learn A Trade (Bunn JDF-2S Q&A)
Bunn Dual DBC Repair (Control Board Replacement/Calibration
มุมมอง 772 หลายเดือนก่อน
Bunn Dual DBC Repair (Control Board Replacement/Calibration
Product Dispenser Valve assembly training
มุมมอง 192 หลายเดือนก่อน
Product Dispenser Valve assembly training
Awesome information. Thanks
What indication did you get to need to replace it? That would be helpful to know.
@dmsampson This was diagnosed by a different service provider but mainly there was a direct short to ground through the relay board.
I need someone fix mine it’s leaking from under water showing on the screen sorry not working
Well it sounds like there is an internal leak that may have damage some of the circuits. You should contact F'real to have them locate a service provider in your area .
@ fix it already thank You working
Back at it. I hope you’re feeling better?
@commercial_service Yes thanks Brother, I am getting better. 👍
buena noche, espero estes bien amigo una pregunta es que tengo un problema con un turbochef encore 2 cuando pongo hacer una receta que me activa los magnetrones la pantalla del touch empiza a parpadear la pantalla y hay momentos que se queda blanca y se activan y desactivan el rele k1 y k2 me podrias ayudar muchas gracias saludos desde colombia
Hello it sounds like there maybe an issue with the door switches or possibly the touchscreen could have a loose connection or the touchscreen may need to be replaced.
@@latcommercialrepair muchas gracias feliz tarde
Do those lines have to be that long ? What's the minimum length allowed?
@deanroyhicks5027 Most manufacturers recommend a max line run between 100 to 150 ft. These lines were so long because the store owner moved the BIB boxes from the back room to the front so he had all of that slack, so I just replaced the full line set instead of using the same lines, that way at least the lines and connectors are new and the system is sanitized.
Hey Kevin, what's the word
@deanroyhicks5027 Hope all is well Brother. 👍
Great video
Thanks for watching!
Hey Kevin, what's the word .
@deanroyhicks5027 Yes Sir thanks for checking in!
Hello, How do I bolt this machine to a countertop in a food truck? If flange feet are required, what size feet? Any help is appreciated!
@shakearahdecuir5647 I have seen some people secure their slush machines with stainless steel brackets that wrap around the feet of the machine and screw the brackets to the counter top. Bunn doesn't offer a security kit for this type of situation so most people with food trucks kind of figure out securing by trial and error with diffent types of brackets and bolting them to the counter. I hope that helps some.
Hey Kevin, what's the word .
Hey Brother, I hope all is man.
You don't have to pre-charge the tank with air? It says too?
These McCann water boosters bladders are usually pre-charged from the factory.
What happens if those plastic standoffs are not removed??
@@Alejaja97 The board can get damaged through a short once power is turned back on.
I got a turbochef when only cooking the chicken wings the cook time is 4:48. But it stops cooking only after about 1 minute and says cooking time is finished. I replaced both RTD probs & the main board. The magnetron & both upper & lower heating elements all checked out fine when amp checking them. There are no error codes stored. I then changed 1 magnetron & 1 diode. Still the same issue. This is only when cooking the chicken wings. The menu also has been updated. Any idea what can be the issue????? S.O.S
Hey thanks for reaching out. That is a strange one , let me take a moment to go over the issue and I will get back to you soon with my thoughts.
@Joelbri2006 After seeing everything you have checked and replaced I can only think that there must be an issue in the firmware menu, because its only doing this with one item. I would check with tech support to see if they can confirm that because I really can think of anything else. Keep me posted on the out if you don't mind.
@latcommercialrepair will do sir
@latcommercialrepair i need to correct myself. I replaced the upper & lower temperature probes not the heating elements. My bad, long story short. Tech support was bamboozled by this as well. They were the ones who suggested replacing the main board & probes. Now they want me to replace the touch pad. But at this point the customer went ahead & approved the replacement of the unit at this time. Tech support also stated they have been getting a lot of calls like this where the chicken just stops cooking 🤷♂️. I thought i would let you know👍👍
@Joelbri2006 Hey thats good information, and it is probably best they replace the unit because it seems like there is a issue with the program . Let me know if this is a 7-Eleven ?
Hey Kevin, what's the word .
@deanroyhicks5027 Hey Brother! I hope all is well thanks for checking in and Happy Holidays Brother!
@latcommercialrepairs: Happy Christmas, hope you have a healthy and prosperous new year. Thanks for all the work you do to provide us with invaluable information.
If you have an insulation tester, you can use the 100 or 250v range to test HV diodes.
Thanks for that information and thanks for watching the channel.
No worries, great channel by the way. Really informative 👍.
@rscelectrical7091 Hey thanks so much , I appreciate it, and I am glad to have you as part of this channel.
Testing with a battery is the only way to test it??
@Alejaja97 Yes this is the recommended test from TurboChef. Some people use the continuity test but that doesn't really show you if the polarity is off so its best to use the 9V battery test.
If a diode is bad does it keep blowing a fuse or is there an error code associated with a failed diode?
@sunburn3358 Good question and no there is not a code that indicates a failed diode. If you have a issue with blown fuses, it will probably be the 20 amp fuse and that is part of the high volt circuit so that could be issues with the HV transformer, magnetrons, and waveguides but you should test the diodes also because a bad diode can be what started the whole issue if the polarity is off because its allowing voltage to travel in both directions. I hope that helps.
Thanks for the info👍👍 kyle were you at🤣this is the guy I was talking to you about. His page is very informative
@@Joelbri2006 Thanks for watching and supporting the channel.
Heyy what'sup Joel. Thanks for the helpful content Kevin @latcommercialrepair
i agree with you
Quick question.... Family owned business... I been trying to help my mom repair a commercial food display. The top part isn't heating. It uses a quartz heating element for the top. I have installed 2 brand new tubs, but they all cracked after maybe 1 or 2 days. What could be the issue? It's a 240v machine.
@Raulito9 Hello Raul, if you can send me the name and model of the display case that will help me find you an answer.
@latcommercialrepair Ah, that's the issue I been having too. We have equipment from the 90's, the info isn't visible. It was a hassle to find the quartz tub.
@Raulito9 Ok I understand. When you get a chance send a picture of the full machine and send a picture of the part you are replacing. Send it to my email: learnatrade1@gmail.com
2
If you offer a service you should have folks available to perform the service. Otherwise you are misleading the customer. It is harder on the retail side but, then you gotta change the advertising. 2
@myapps9258 Thats all I'm saying! Thank you!
2
2
2
2
awesome page and I love the videos
@@fountainservices1254 Thanks so much I enjoy making the videos and it also helps me in so many ways! 🙏
For the top heater, if the white insulator wasn’t in the package, will cause issues in the future?
@@Alejaja97 Hi yes if the white insulator for the termainal is missing, it can cause the heater to short eventually against the frame.
Great video! What’s the ideal amperage for you guys?
@@Alejaja97 For your amp test I look for between 14 to 16 amps. Each side should give between 7 to 8 amps independently.
Great video 👍 never thought about putting insulation tape underneath the relay board. It makes sense👍
@@Joelbri2006 Thank you for watching!
Here’s one for you I got this turbo chef blowing control boards left and right. Called tech support plenty of times. Each time different and replaced what they said but still blowing the I/o board. Heats up to 500 ready to cook as soon as you push to cook something the screen goes blank and flickers an then the control board relay blows it’s the yellow board con 3019. Have you come across something like this let me know
@christopheralvarado351 Wow! That is a great one and no I have never run across that. I am not sure what model oven it is but I am assuming its a Bullet model or an Encore model, and I am not sure what part they had you replace but from your description of how its blowing the board it sounds like there is a short in the touchpad or the display board. If you can get back to me and let me know the model of the oven , then I can probably help figure out whats causing that board to blow like that. Thanks for that question and please get back to me with that information.
@ it’s and encore 2 model. The newer model but with the glass relays on the right side of the unit.
@christopheralvarado351 Ok is it blowing any of the fuses or the relays?
Very informative, great job
Thank you!
awesome video!
@@laceytaylor5470 thank you for watching!
Great video Kevin! So much good information. Thanks!
@@cainwp Your welcome and thank you for watching!
How would you clean the ceiling tiles with the red syrup?
@tphpwalker If its caught early the tiles can be steam cleaned and vacuumed. Since this has been sitting for a few days, the tiles will have to be replaced.
I HAVE A QUESTIOn. do you know of any service techs in the DFW that can repair my bunn ultra 2 machine? i cant seem to find a tech
@@MoK86 Thank you for reaching out with your question. The best advice I can offer would be to contact Bunn MFG. They will be able to locate a service provider for you. Here's their number 800-286-6070. I hope this helps.
💡
Wish this video had a better connection. It’s kind of hard to see what you’re doing. Question: what if product is leaking from the nozzle after it is dispensed? Do i just change the faceplate? Brix is good. Just leaking extra product from where it dispenses. Thanks for helping. I definitely subscribed. 😊
Hello, my apologies for the connection issue on the video. I appreciate you letting me and I am always working towards making the better for viewing. As far as your nozzle leaking issue, you can change out the complete faceplate or replace the SDV Rebuild kit. At times the nozzle will drip a little product after dispensing but if there is a steady dripping I suggest replacement of the faceplate assembly or the SDV Kit which replaces the inner valve body and seals and then make sure nozzle cap is secure and spring loaded. I hope this helps and thank you for your support.
Hello I hope this video will help you. Please keep me posted. th-cam.com/video/J5swANaDP-Y/w-d-xo.htmlsi=4WOBnxfSc-dDKtqF
Great advice and learning tool. Thank you.
@@benjaminferrel5474 Thank you for your comment and thank you for watching!
Wow Kevin, didn't expect the video to be based off of my question. That was amazing brother. Very helpful. Machine is disassembled at the moment, but last try was 50° on the left and 40° on the right. I want to see if I can get a tech to put gages on the compressor to make sure freon doesn't have a leak. Solenoids have a strong magnetic pull, and the only leak I have is from the faucet seal. Gonna download the manual and will keep you updated. I greatly appreciate you Sir, and the helpful video. Blessings *edit* I may hold off on freon test since it does get down to 40° on one side. I'll try to email you some pictures so you can tell me if you see any visual issues.
Hey James, I'm glad this was helpful . It is possible that the machine could be low on refrigerant but I would check the torque/ temp readings without the hoppers on and see if you getting between 0 to 4 on the torque on both sides. If your not you will want to replace your shaft assemblies and a PM kit and then see if you start getting a better freeze down . I not then you will then need to see about having a tech test your system for a refrigerant leak. Keep me posted on your progress Brother . Thanks for watching!
I have the same machine. Bought it used for my shop. For some reason, it will get cold but not freeze up. Compressor kicks on, augers spin, shift pins are intact and clean. I let in run for like 6 hours and all it did was get cold, about 50°. Do I have a solenoid problem? Or dirty parts or something? It's driving me crazy. I could literally see the one from the video getting cold as soon as the compressor kicked on. Thanks for any help in advance!
@jameswarren4747 Hello James, you should make sure both sides are in the ICE mode. They should both say ICE on the display in all CAPS. I will be doing a video called HVACR Tech Talk soon and I will go over your question and give some more answers for you on that issue. If you miss the video I will send you the link so you can go over it and hopefully fix your issue.
@latcommercialrepair Thanks. They are in Ice mode and the torque numbers are in range with the black square next to them. There are no codes popping except for a seal maintenance code. Could the seal you replaced in the front prevent freezing?
@jameswarren4747 That seal message could be part of the issue it sounds like your machine is going into freeze mode but it seems like the solenoids on either side are not opening up. If your display is showing the solenoids are open with the full highlighted section next to your torque/ temp numbers then remove the left panel and place the tip of a slotted screwdriver on top of each coil if you feel a pull on your screwdriver tip the coils are open and refrigerant is flowing. Make sure the condenser fan is turning and not stuck, if the condenser fan is turning and the coils are open the you may have a low charge . Meaning there maybe a refrigerant leak . In that case you will need to connect Refrigeration guages to the access ports to check the pressures. Your pressures should be at least 35 to 40 psi on the low side. I hope this helps some.
Hello James, here is a video for you that I think will help you with your Ultra 2 issue. Let me know if it helps. th-cam.com/video/2TwTQIOtRMY/w-d-xo.htmlsi=wkpvF8bl4hvF-2Rh
Pizzas come out great in these.
So would thi water bath issue keep compressor from coming on. Have a jdf 2s and it is not cooling
If the cooling cabnet is not getting cold the unit will go into a shutdown. There are multiple issues that can cause this. It could be a temperature probe issue, a water pump issue, it could be that the compressor switch is not turned on. I would first check those things first. Usually if there is a pump issue you will find that the water bath will freeze up completely because the pump is not circulating water . I hope that helps some.
@Getsober4life I want to add to your diagnosis of your JDF-2 question. If the compressor is not starting up, you might want to first check the water level in the water bath. You can see the water level by removing the front panel at the base of the machine. Look at the water level at the clear tube that connects to a tee fitting that has a drain line connected to the other side of the tee fitting. The water level should be at the bottom of the Tee fitting of the tank tube, if it is not, then the water must be filled up to that level in order for the compressor to come on. I hope this helps.
Here is a recent video that may help I put the link for the service manual in the description. th-cam.com/video/oDXNtmyJT04/w-d-xo.htmlsi=BDr8gZEjA-LoPhga
Those units are over 10,000 new.
@rsjrmy Yes they are up there but they are worth it for the convenience stores.
Hardest working man in our space.
@commercial_service Hey I am just a reflection of you Brother!
Excellent work, much appreciated
@samwasar7136 Thanks so much Sam!