Subcool HVAC
United States
เข้าร่วมเมื่อ 29 ธ.ค. 2013
Welcome to the channel, I Started the channel to share my HVACR Service experiences. At 35yrs and counting in the trade with State Contractor License, there’s a mix of Commercial and Residential troubleshooting service work . Thanks for Watching Subcool HVAC!
Installing Symbio Option Modules And Prepping Trane 8.5 Ton Precedent Package Unit For Installation
Checking out a new Trane 8.5 ton Precedent package unit and pre installation setup with electric heater with economizer #hvac #trane #symbio
มุมมอง: 1 407
วีดีโอ
Almost Lost The Engine In My Subcool Van Heading To A Service Call…This Could’ve Been Bad
มุมมอง 1.1Kวันที่ผ่านมา
This was a close one had it not been for a few circumstances that led up to a problem that could have cost a lot more than it did, Huge Thanks To My Son 👊 #hvac #promaster #automechanic #kaiweets Kaiweets Borescdope Link kaiweets.com/products/kba01-two-way-articulating-borescope?sca_ref=7366987.UARftRCU8A 15% Off Discount Code 15Subcool Amazon 15% off NXD9CZ2N 1-31-25
Cooling Fans Replacement || Why Is The Drive Operating Backwards? .. Toshiba Q9 HVAC Drive
มุมมอง 1.1K14 วันที่ผ่านมา
Follow up work order to replace Toshiba drive cooling fans the easy way along with figuring out why the drive operates opposite of front switch position #hvac #toshiba #hvacmaintenance
Overpriced OEM Parts $2800! Really? Replacing Outside Air RH/Temp Sensor On Addison RTU
มุมมอง 2.4K14 วันที่ผ่านมา
Follow up work order to replace a failed OARH/Temp sensor with an OEM replacement.. I’m in the wrong end of the business, these parts are Expensive!! #hvac #airconditioning #expensive
Chiller 1 Will Not Start… Let’s Just Keep Pushing Buttons
มุมมอง 4.3K21 วันที่ผ่านมา
Got a call for a RTHD Trane Chiller not able to reset and start, customer doesn’t know what they are doing when it comes to resetting …Thanks for watching!#hvac #chiller #trane
Addison 8 Ton RTU Final Repairs And Start Up : Until Next Year
มุมมอง 89528 วันที่ผ่านมา
Took a minute to get replacement parts for this Addison unit, the weak link is a rusted snap ring that holds the condenser fan assembly to the motor #hvac #addison #airconditioning
Scotsman Prodigy Ice Machine C0530MA Max Harvest Shut Down Code 2… Not Making Ice
มุมมอง 9432 หลายเดือนก่อน
Got a work order for a Scotsman Prodigy Ice machine not producing ice and Alarm code 2 Max Harvest Shutdown #icemachine #scotsman #hvacr
Inspecting HVAC Conduit With KAIWEETS KBA01 Borescope: Review and Test
มุมมอง 4472 หลายเดือนก่อน
Reviewing a 2 Way Articulating Borescope from Kaiweets KBA01 … #hvac #Kaiweets #Borescope kaiweets.com/products/kba01-two-way-articulating-borescope?sca_ref=7366987.UARftRCU8A Discount Code 15Subcool a.co/d/gmJMngk Amazon 15% off Code NXD9CZ2N Ends 1-31-25
Addison 30 Ton RTU Interface Installation Part No EQT1-4-BNK…Operational Check
มุมมอง 9752 หลายเดือนก่อน
Work order to install Equipment Touch interface on Addison RTU .. found a hidden problem. #hvac #airconditioning
Trane Chiller RTHD Water Temp Sensor Upgrade Does Not Go As Planned
มุมมอง 2.3K3 หลายเดือนก่อน
When repairing some non functioning condenser water temp sensors turns out to be more than expected, first time running into this issue #hvac #trane #chiller
Getting Chiller 2 Trane RTHC Back Online And Finding A Hidden Problem
มุมมอง 2.8K3 หลายเดือนก่อน
Got a work order for chillers offline and not restarting after clearing the Alarms #chiller #hvac #airconditioner
Walk In Cooler Not Having A Good Day… Looking For Answers..
มุมมอง 2.5K3 หลายเดือนก่อน
Got a work order for a walk in cooler blowing hot air, food has gone bad… here’s what I found #refrigeration #hvacrepair #cooler
Uniweld MaxEvac 6 CFM Cordless HVAC Vacuum Pump.. 3 Different Battery Brand Options
มุมมอง 1.4K3 หลายเดือนก่อน
Trying out a new Uniweld cordless vacuum pump that I purchased at my local Gemaire Distributor #Uniweld #hvac #airconditioning
2Yr Old Goodman AC Just Stopped cooling… Aluminum Coil Repair
มุมมอง 8864 หลายเดือนก่อน
Customer states the ac just stopped cooling all the sudden, blowing just a little cool air #hvac #airconditioner
Evapco 10hp Cooling Tower Motor Replacement.. This One Tried To Be Difficult
มุมมอง 2K4 หลายเดือนก่อน
Evapco 10hp Cooling Tower Motor Replacement.. This One Tried To Be Difficult
Trane 25 Ton Condensing Unit Blowing Fuses … I Should Have Known
มุมมอง 1.9K4 หลายเดือนก่อน
Trane 25 Ton Condensing Unit Blowing Fuses … I Should Have Known
Klein MOD BOX 54821MB 1 Drawer And 54803MB Medium Drawer Cleaned Up Clutter Area
มุมมอง 1.1K4 หลายเดือนก่อน
Klein MOD BOX 54821MB 1 Drawer And 54803MB Medium Drawer Cleaned Up Clutter Area
Emergency Work Order .. Tower Fans For Chillers Not Spinning After Early Storm… Steaming Hot
มุมมอง 1.7K5 หลายเดือนก่อน
Emergency Work Order .. Tower Fans For Chillers Not Spinning After Early Storm… Steaming Hot
Chilled Water Air Handler Making Loud Noise And Not Cooling Properly
มุมมอง 2.3K5 หลายเดือนก่อน
Chilled Water Air Handler Making Loud Noise And Not Cooling Properly
York YMC2 Magnetic Bearing Excessive Shutdown Alarm…
มุมมอง 9835 หลายเดือนก่อน
York YMC2 Magnetic Bearing Excessive Shutdown Alarm…
Chiller In Alarm …Trane CGAM Chiller Comm Loss Faults .. Discharge Temp and EXV
มุมมอง 2.6K6 หลายเดือนก่อน
Chiller In Alarm …Trane CGAM Chiller Comm Loss Faults .. Discharge Temp and EXV
Carrier RTU 8.5 Ton Not Turning On Affecting The Weight Room… It’s Getting Hot
มุมมอง 8K6 หลายเดือนก่อน
Carrier RTU 8.5 Ton Not Turning On Affecting The Weight Room… It’s Getting Hot
14yr Old 5 Ton Ruud Iced Up || Customer Prefers To Repair If Possible … Let’s Check It Out..
มุมมอง 11K7 หลายเดือนก่อน
14yr Old 5 Ton Ruud Iced Up || Customer Prefers To Repair If Possible … Let’s Check It Out..
NAVAC 18v 2 CFM Cordless Vacuum Pump VS HERCULES 20v 2 CFM Brushless HVAC Vacuum Pump
มุมมอง 9K7 หลายเดือนก่อน
NAVAC 18v 2 CFM Cordless Vacuum Pump VS HERCULES 20v 2 CFM Brushless HVAC Vacuum Pump
Air Handler Blowing Warm Air And Trane RTHD Chiller Leak … Yep That’s Oil
มุมมอง 4.4K8 หลายเดือนก่อน
Air Handler Blowing Warm Air And Trane RTHD Chiller Leak … Yep That’s Oil
York YMC2 Service Needed || That Doesn’t Sound Good
มุมมอง 3.2K8 หลายเดือนก่อน
York YMC2 Service Needed || That Doesn’t Sound Good
Condenser Pump And Motor Install With Some York YMC2 Surging Issues
มุมมอง 4.3K8 หลายเดือนก่อน
Condenser Pump And Motor Install With Some York YMC2 Surging Issues
TRANE Stealth Chiller Circuit 1 AFD 1A Bus Under Volts | Part 2 Results Are In ⚡️🦎
มุมมอง 3.4K8 หลายเดือนก่อน
TRANE Stealth Chiller Circuit 1 AFD 1A Bus Under Volts | Part 2 Results Are In ⚡️🦎
TRANE RTAE 150 Air Cooled Chiller Circuit 1 AFD 1A Bus Under Voltage Alarm Not Resetting…Part 1
มุมมอง 6K9 หลายเดือนก่อน
TRANE RTAE 150 Air Cooled Chiller Circuit 1 AFD 1A Bus Under Voltage Alarm Not Resetting…Part 1
York Ymc2 Chillers Shutdown Shortly After Scheduled Start Time… Tripped Main.. No Display VFD
มุมมอง 17K9 หลายเดือนก่อน
York Ymc2 Chillers Shutdown Shortly After Scheduled Start Time… Tripped Main.. No Display VFD
I imagine the last guy said, compressor isn't running, it's low on gas, So you need a new system and here's the bid...
@@throttlebottle5906 That and here’s a price for a service contract… see you in 6 months.
plastic fantastic and chrysler doing it's usual thing. you're lucky it lasted as long as it did....
Failure is built into design these days , of course warranty ran out 6 months ago
"hey where do you want the control box", ""oh I don't know put it over there up high so it doesn't get hit or smashed with anything"". 🤣🤣
🏀 yep, They play ball in there
Will it detect a leak on copper tubing, example: I just brazed into a unit and my gauges are detecting a leak, could this thing find it for me?
I have had good experiences detecting r410a and r22 leaks, double check your hose seals and valve seals are not the leak source as well
Word of advice.....you really have to set fan correctly with those microchannel evaps. They will drip water into the space if it was a vertical config. With this being horizontal, you still will get water in the evap section if not set correctly.
Thanks for the advice 👍
@subcoolHVAC you do great work brother. Love the channel.
I appreciate that 👊
I have that same unit at a facility, we have changed the ECM motor twice in 9 years. You need to remove the top, get a ladder and spend a ton of money to get that motor. Worst thing Trane has done
@@brushben22 I fully expect that since one of the items listed in IOM is supply fan failure if not up to 30rpm within 40sec it shutdown.
Great video. Thank you for sharing
Thanks Zekenzy !
From all brands Trane labels and schematics are the worst, most will fade out in the first year. Nice vid by the way 👍
Yep, the schematic is the mercy of a ziplock bag on the inside panel.
Nice simple little unit. Got to enjoy thise days
Yeah, grateful for low stress day 👍
Wooo, those are expensive Trane 8.5 Ton Precedent Package Unit, the ones I can easily find are around $11,600 plus shipping. At that price they better last a lifetime.
@@davidnull5590 Yeah, that’s a good estimate. Is 10 years asking too much 😉
Absolute trash. God speed my man.
We’ll never be without work
Nice work Subcool.
Thank you Steven !
Nicely done, thanks Subcool.
Thanks Steve, I Appreciate the feedback!
I'm installing a 7.5T split where I work now. Didn't know you had to have an option module just to use the strips. They didn't say anything when we got the quote. With Reliatel, all you ever had to do was cut the jumper to enable them.
@@topher8634 yeah, I had to remove the jump and install on P4 and from P5 to the OA module P5. First time dealing with Symbio but from what the Installation sheet looks like what they want.
Symbio is the epitome of overly complicated controls & poor QC. Haven't had a single startup that didn't have a factory issue.
@Jeremy-gt8xf I fully expect some type of issue , might be installer error on my part 😂
Both compressor are deference 1 is big than other why ?
There probably different stages, or one is a compressor and one is a receiver.
2 stages
If I remember correctly, one compressor is about 1/3 of the cooling (maybe a little bit more); the other compressor is about 2/3 of the cooling.
do the 454b regs go with commercail applications ???
Residential/light commercial Any manufactured after January 1, 2025 will be A2L, dealers can sell r410a units mfg prior still . Trane will use r454b from what I understand
Yessir 454B with RDS mitigation
Good video)
Thanks Victor 👊
First mistake was buying a dodge. Second mistake was keeping it. Don't make a 3rd😂
Guilty 😂 although ROI wasn’t bad for 5yrs
@subcoolHVAC Don't feel to bad, I have a LML duramax that has nearly bankrupted me with emissions parts. I'm in so deep I just can't sell it
@PorkChopAChunky Thanks, I feel better.
Oh no!
Exactly 👍
Nice to know we have a mechanic in the family
Absolutely 👍
Try crayon wax. Learned that trick from a TH-cam mechanic. Thanks for the update bud
Oh yeah, I saw that. Will give it a try. Thanks 👊
The oil cooler on those Pentastars are notorious for failure. Usually fail around 50K. Also the water drainage is an issue on the Pro masters and Ford's Transit vans. Usually end up shorting the coils out.
Thanks for the info , got that leak sealed 🤞
You have gorgeous eyes! That was nice that your son helped and you didn't try and drive your van without oil! THAT would have been a disaster! I really like your videos. Great content and good detail! Thank you.
@@pomonabill220 Thanks for watching 👀
Props to your son....he saved the day....proud dad moment there
Thanks Jason! Yes he did, and saved a big repair bill 💵
Good job fixing your own alongside your son
@thesilentonevictor Thanks, he definitely saved time and $.
“Outstanding” ✅
Thanks for Watching 👍
ABB > Toshiba
Agreed 👍
That sucker was dirty....when you blew it out....i was damn....how has that drive survived this long....kudos to you. Enjoyed the video 😊
Everything at that same level was covered in dust, cleaning services must only go up to 8ft high😀
I just find things are not serviceable anymore
It could have been more service friendly for sure
One of the main killers of VFDs
Definitely 👍
Thanks 👍
Great video!
@@ccthepope Thank you for watching!
Nice work Subcool, thank you for the knowledge.
Glad you enjoyed it!
Oops, commented too early. But still, a head's up: Most drives have a parameter setting that electrically reverses the motor. It allows a lazy installer to reverse rotation without swapping motor wires. It is usually disabled by default. An extensive power down, faulty memory keep alive supercap/battery, or power surge can toggle that parameter when the drive is powered back up. Another thing that causes that is static electricity, which could have happened when you blew the drive out in the truck. Early versions of some Damnfussy drives were prone to that and defaulting to full factory parameters.
@@mxslick50 yep, in this case the drive operated when bypass selected on front panel and bypass when drive selected.,
Damn! Yesterday I quoted an OEM indoor blower motor on a Lennox RTU, 3 phase 460v 2hp… at cost was over $1,000. And I thought THAT was ridiculous. What kind of unit is that? Never seen one of those before.
That sounds right these days, this is an Addison RTU… out of Orlando, FL
Was it $2800 for just the sensor or both sensor and interface?
Unfortunately just the sensor alone, the interface cost more. With the help of a subscriber we’ve been able to find replacement sensors at better cost since this order.
Hey have you had any trouble with the Bitzer scrolls ? We've had tons of compressor failures with them .
Not yet, what type of failure are you having?
@subcoolHVAC grounded windings and black oil ! They've had a very bad series of them in my opinion . They've supposedly corrected the issue but I'm sceptical because I've heard of other failures even with the supposed "good" ones ...
Thanks for the heads up, will make sure to go through all electrical connections . We do get a good amount of surges and momentary outages , especially with Thunderstorms
Curious to your thoughts on Addison RTU? I still prefer Aaon with Prism.
So far not impressed with Addison, although I don’t have any Aaon systems in my area. Prism seems like the better interface
It's supposed to go on North side to keep it out of direct sun. Direct sun on OA sensors affects sensor accuracy. Needs to be in a shaded place at all times. I Like your solution though, easy adjustment. Commissioning should have caught that.
@@HVACTIME Yep, the other 2 at this site face West 😂
Holden your right. Good job on your chiller academy.
Nice work as always Subcool.
Thanks Steven 👊
Awfully nice unit for a kitchen lol. Thanks for the video sc
Yeah , its a bit overkill . Thanks Eric 👍
Addison and aaon must be cousins
It looks that way 😀
Thanks ThumperKJFK !
Retired computer person. I enjoyed watching your video. I'll be doing a search for other chiller videos. I just enjoy learning new stuff.
@@NathanZSolomon That’s awesome, Thanks for watching!
Nice
Thanks 👍
Keep them coming bro good job.
Definitely, Thanks HetyLefty
Seems like there's a boat load of missing water. Gotta love LARPers who just screw with settings
The funny part is the alarm happened when the site was unoccupied… running fine today 😀
Great video. Thank you for sharing. Happy New Year 2025
Happy New Year, Thanks for Watching!
Shouldn't there be a check valve somewhere in the line to keep all the water from draining back to the tower sump when the pump shuts down? (Or if there is one, it's failed.) The scenario I see here is, pump shuts down, water flows back to tower, tower overflows, some genius at the facility sees the over flow and adjusts the float trying to stop the overflow. Side note: I did a lot of work on BacNet for Trane. Mainly at hospitals and other medical facilities. At one facility I had to, under Trane's direction, do an initial startup of a very large RTU. The one thing that was a real pucker factor was adjusting the blower drives, with the warning that if I overspeed the supply side I could literally explode the ductwork. 😮 And at the last one I did (with water chillers) we had to literally field rewire an air handler where supply and return sides were decoupled from inline to side by side (someone screwed up on the basement plans.) That was a nighmare to fix.
Yeah there’s a check valve and it is working, it’s just a funky piping setup .. all good for now as long as it stays in auto
Nice....always fun when people just start pushing buttons without either the knowledge or leaving a note. Does those tower(s) have a bypass? That loop was air locked pretty good.
Everyday is entertaining here, there’s no bypass… it’s all good today
I wonder how long before the new fan will fall off. Gotta love all the new "efficient" engineering and design.
Hopefully longer than 3yrs , I did coat the shaft end and clip with rust oleum afterwards