14yr Old 5 Ton Ruud Iced Up || Customer Prefers To Repair If Possible … Let’s Check It Out..
มุมมอง 9K14 วันที่ผ่านมา
Referred customer interested in second opinion to repair 14yr old Ruud 5 ton system that iced up #airconditioner #hvac #airconditioning #hvacrepair
NAVAC 18v 2 CFM Cordless Pump …HERCULES 20v 2CFM Brushless HVAC Vacuum Pump Comparison
มุมมอง 6Kหลายเดือนก่อน
Trying out the Hercules HVAC 2cfm vacuum pump that I picked up at HARBOR FREIGHT… is it worth the money and how did it compare to my NAVAC 2cfm #hvac #harborfreight #navac
Air Handler Blowing Warm Air And Trane RTHD Chiller Leak … Yep That’s Oil
มุมมอง 3.8Kหลายเดือนก่อน
Got a work order for a building warm and found one Trane chiller has developed a leak at 2 yrs old #trane #chiller #hvac
York YMC2 Service Needed || That Doesn’t Sound Good
มุมมอง 2.7Kหลายเดือนก่อน
Met up with JCI tech to service our YMC2 chillers that have been surging and Loss of Subcooler Liquid Seal warning resolved #york #chiller #hvac
Condenser Pump And Motor Install With Some York YMC2 Surging Issues
มุมมอง 4Kหลายเดือนก่อน
30hp condenser motor and pump reinstalled for our York YMC2 chillers and now Chiller 1 is starting to surge… #hvac #york #chiller #controller
TRANE Stealth Chiller Circuit 1 AFD 1A Bus Under Volts | Part 2 Results Are In ⚡️🦎
มุมมอง 3K2 หลายเดือนก่อน
Follow up on Trane RTAE that blew 200amp AFD fuses from what appeared to be just a lizard shorting the phase… here’s the results #hvac #trane #hvacrepair #chiller
TRANE RTAE 150 Air Cooled Chiller Circuit 1 AFD 1A Bus Under Voltage Alarm Not Resetting…Part 1
มุมมอง 5K2 หลายเดือนก่อน
Received a work order to repair a Trane RTAE 150 not resetting and in Alarm for circuit 1 … here’s what I found #hvac #trane #airconditioning #chiller
York Ymc2 Chillers Shutdown Shortly After Scheduled Start Time… Tripped Main.. No Display VFD
มุมมอง 16K2 หลายเดือนก่อน
Was contacted early in the morning prior to shift start by a coworker that the chillers abruptly stopped after starting, no pumps or chillers running, no display on vfd’s and a main breaker tripped…Priority work order generated and Here’s how we responded #chiller #york #hvac
Cooling Tower Overflowing Follow Up Work Order | I Should’ve Check This
มุมมอง 35K2 หลายเดือนก่อน
Going back to figure out cooling tower 1 water overflowing during shutdown #hvac #coolingtower #chiller
TRANE RTHD’s Had Trouble Restarting After Power Outage | EMS Override!
มุมมอง 8K2 หลายเดือนก่อน
Got a work order stating chillers not starting up , had to troubleshoot where the night crew left off #chiller #hvac #airconditioning
Troubleshooting High Coil Temp Reading | York Chilled Water Air Handler
มุมมอง 2.9K2 หลายเดือนก่อน
Got a work order to repair/replace high coil temperature thermistor and end up finding more issues. #airconditioning #hvac #chiller #temperature
Building A Signal Generator With Parts In The Garage
มุมมอง 6493 หลายเดือนก่อน
I decided to build my own signal generator and put those little Dewalt batteries to good use #hvac #signalgenerator #dewalt #garage a.co/d/cmmTZeQ a.co/d/2SNGgWV a.co/d/aip1wou
Air Handler Blowing Warm Repair … EMS Reload And Chiller Down .. What Else Can Go Wrong?
มุมมอง 2.6K3 หลายเดือนก่อน
Got a work order for one air handler blowing warm which goes from controller problems to Chiller Alarms , tripped 175 amp breaker for pump motors, low meg reading on one motor , here’s what I found #chiller #hvac #controller
Trane Climate Changer AHU Making A Lot of Noise…Old Still Works
มุมมอง 2.8K3 หลายเดือนก่อน
Got a work order for a noisy air handler on start up , here’s what I found #hvac #airconditioning #hvacrepair #trane
30 HP Secondary Chiller Pump Motor Replacement.. Chiller Plant
มุมมอง 2.8K3 หลายเดือนก่อน
30 HP Secondary Chiller Pump Motor Replacement.. Chiller Plant
The Gym AC Not Working.. Old Toshiba Q9 Speed Drive Overheat Fault.. Need More Info
มุมมอง 4.9K3 หลายเดือนก่อน
The Gym AC Not Working.. Old Toshiba Q9 Speed Drive Overheat Fault.. Need More Info
Chiller Cooling Tower Wants Attention .. Pump Power And Small Temp Difference
มุมมอง 6K3 หลายเดือนก่อน
Chiller Cooling Tower Wants Attention .. Pump Power And Small Temp Difference
Chiller Pump Strainer Pull And Clean HVAC Maintenance… New Tool
มุมมอง 3.7K3 หลายเดือนก่อน
Chiller Pump Strainer Pull And Clean HVAC Maintenance… New Tool
Leaking TACO Condenser Chiller Pump Removal And Breakdown
มุมมอง 5K3 หลายเดือนก่อน
Leaking TACO Condenser Chiller Pump Removal And Breakdown
10 Ton Carrier RTU Intermittent Cooling… Almost A Call Back. Good Thing I Waited
มุมมอง 6K4 หลายเดือนก่อน
10 Ton Carrier RTU Intermittent Cooling… Almost A Call Back. Good Thing I Waited
TRANE RTHD Loss Of Oil Alarm… RTHC No Evap Flow … Both Chillers Not Working Call
มุมมอง 6K4 หลายเดือนก่อน
TRANE RTHD Loss Of Oil Alarm… RTHC No Evap Flow … Both Chillers Not Working Call
York Chilled Water Air Handler Too Cold …… Rooms Are Freezing
มุมมอง 5K4 หลายเดือนก่อน
York Chilled Water Air Handler Too Cold …… Rooms Are Freezing
No Chillers Running And Burning Smell … A60 External Interlock Drive Alarm Issue
มุมมอง 35K4 หลายเดือนก่อน
No Chillers Running And Burning Smell … A60 External Interlock Drive Alarm Issue
Loss Of Charge TRANE CHILLER CGAM070F … Leaks or Something Else
มุมมอง 3.1K4 หลายเดือนก่อน
Loss Of Charge TRANE CHILLER CGAM070F … Leaks or Something Else
York Centrifugal Fan Blower Replacement… The End
มุมมอง 1.4K4 หลายเดือนก่อน
York Centrifugal Fan Blower Replacement… The End
Install And Setup Motor Saver 455….Simple Solution
มุมมอง 1.3K4 หลายเดือนก่อน
Install And Setup Motor Saver 455….Simple Solution
Chiller 2 Down After Blown Pump Motor || Found The Source
มุมมอง 6K5 หลายเดือนก่อน
Chiller 2 Down After Blown Pump Motor || Found The Source
Defeated … I Had To Tap Out On This One.. Sometimes It Happens
มุมมอง 2K5 หลายเดือนก่อน
Defeated … I Had To Tap Out On This One.. Sometimes It Happens
The Drive Was Right … It’s Motor Time | 5hp 184T 3 Phase
มุมมอง 2K5 หลายเดือนก่อน
The Drive Was Right … It’s Motor Time | 5hp 184T 3 Phase

ความคิดเห็น

  • @SombraLocs
    @SombraLocs 6 ชั่วโมงที่ผ่านมา

    Those Carriers are junk!

    • @subcoolHVAC
      @subcoolHVAC 3 ชั่วโมงที่ผ่านมา

      Willis wouldn’t be proud 🥲

  • @lucienadecuba4728
    @lucienadecuba4728 9 ชั่วโมงที่ผ่านมา

    Why not install the copper first and set it to vacuum to win time while its vacuuming you finish the rest great job

    • @subcoolHVAC
      @subcoolHVAC 9 ชั่วโมงที่ผ่านมา

      I just work from top to bottom so I can focus on test/vacuum at the end. Thanks for watching

  • @caffeinatedinsanity2324
    @caffeinatedinsanity2324 วันที่ผ่านมา

    Not really an hvac tech myself but mostly working on building automation projects yet I also do some service calls from a distance from my office to figure out what is going on. Fishing for information when dealing with problems is always a fun game. Steps I undertake: -Open the BMS and if there are GUIs created for the sector, open them and do a quick scan on the rooms of the building. Afterwards, narrow down the issue. Usually, i have dealt with lack of cooling on hot summer days, as opposed to the lack of heating during winter, for some reasons. Most of times they were RTUs feeding cool air to VAV damper boxes. The first thing I always notice is that all rooms fed by the same system are at least 2-3 °C above their setpoint (usually around 21-22°C), even if the customer tells you only a few are problematic (ex: 27°C, which is really hot). Either they genuinely had a mechanical problem that needed to be fixed, or sometimes it's just a case of undersized unit. If you see that the unit fails to maintain duct static pressure even when the fan is at 100% speed (because the room controls are all at maximum cooling demand and therefore, maximum airflow) or if all compressors are on and recently maintained but the air is still above 20°C, you can tell right away that the unit is undersized for the building's requirements. Sometimes I stumble upon autonomous units integrated on the BMS's BACnet network that generally give a lot of info, sometime I stumble across ones where we put our electronics on to control them and the equipments have feedbacks for a bunch of stuff (ex a current transducer on the power lines of the blower, compressor, etc...), and sometimes no feedbacks on the real state of equipments, mostly older installations. I have limited skills when it comes to troubleshooting machines physically, but whenever I can, I go fish for info for my colleagues who might be dispatched there.

    • @subcoolHVAC
      @subcoolHVAC วันที่ผ่านมา

      Thanks for commenting, hopefully you found this call interesting

  • @maheradous9257
    @maheradous9257 2 วันที่ผ่านมา

    Good job 👍

    • @subcoolHVAC
      @subcoolHVAC วันที่ผ่านมา

      Thanks 👍

  • @abdullah_q8171
    @abdullah_q8171 2 วันที่ผ่านมา

    Nice jop man

    • @subcoolHVAC
      @subcoolHVAC 2 วันที่ผ่านมา

      Thanks for watching!

  • @abdullah_q8171
    @abdullah_q8171 2 วันที่ผ่านมา

    Motor 3 hp

    • @subcoolHVAC
      @subcoolHVAC 2 วันที่ผ่านมา

      Yes , that’s what we installed

  • @c21meister
    @c21meister 2 วันที่ผ่านมา

    Waiting on a vfd now for a carrier

    • @subcoolHVAC
      @subcoolHVAC 2 วันที่ผ่านมา

      😔we do a lot of waiting

  • @AaronPowellvox
    @AaronPowellvox 2 วันที่ผ่านมา

    So THAT’S where the noise was coming from

  • @AaronPowellvox
    @AaronPowellvox 3 วันที่ผ่านมา

    lol. That motor sounds like grandma’s wind chimes.

    • @subcoolHVAC
      @subcoolHVAC 3 วันที่ผ่านมา

      Yep, or a 10 speed bicycle 😁

  • @marcelocortez18
    @marcelocortez18 3 วันที่ผ่านมา

    Have have some really good content, u should consider gettin a tripod to show yr work/installations, I think that would be cool to see. Keep up the cool videos

    • @subcoolHVAC
      @subcoolHVAC 3 วันที่ผ่านมา

      Thanks, the tripod would slow me down, I just try to film as I go and get the repair done as efficiently as possible. I appreciate your input 👍

    • @marcelocortez18
      @marcelocortez18 3 วันที่ผ่านมา

      @subcoolHVAC yea I understand

  • @robmcshane3260
    @robmcshane3260 3 วันที่ผ่านมา

    Don’t you love where the vfd is mounted. F carrier!!

    • @subcoolHVAC
      @subcoolHVAC 3 วันที่ผ่านมา

      It’s genius 🤣

    • @c21meister
      @c21meister วันที่ผ่านมา

      @@robmcshane3260 right in the airstream with all the moisture

    • @subcoolHVAC
      @subcoolHVAC วันที่ผ่านมา

      You know it 👍

  • @stevencossaboon3237
    @stevencossaboon3237 3 วันที่ผ่านมา

    Nice troubleshooting and video Subcool.

    • @subcoolHVAC
      @subcoolHVAC 3 วันที่ผ่านมา

      Thanks Steven !!

  • @Attest411
    @Attest411 3 วันที่ผ่านมา

    Just enough information so you can out source the motor

    • @subcoolHVAC
      @subcoolHVAC 3 วันที่ผ่านมา

      Yep, motor volts/amps and frame 👍

  • @AaronPowellvox
    @AaronPowellvox 3 วันที่ผ่านมา

    Great work man. I wish they came out with that vacuum pump before I bought my Navac. They’re pretty awesome! I finally made my first heating and air video on my channel, hopefully I can reach a few people.

    • @subcoolHVAC
      @subcoolHVAC 3 วันที่ผ่านมา

      The NAVAC is a great pump either way, I’ll check out the video, Thanks for commenting 👍

  • @jrsmyth9761
    @jrsmyth9761 3 วันที่ผ่านมา

    Carrier does have a service/tech bulletin on how to wire around the VFD. This unit appears to be cool only so low voltage control wiring you did should be okay. However, there is already a signal wire in the unit for this purpose, well it is there if there was no VFD. Also, I did not see that the wires ran through the fuses that are in the blower compartment. Maybe it is different on 460VAC, I don't think I have worked on anything over 240VAC that I bypassed the VFD on. The fuses are supposed to still be used but need to be changed to a different type. I usually run the yellow wires that are on the capacitor for the condenser fan motor directly to the contactor instead of to the capacitor. Just my OCD/thing to do.

    • @subcoolHVAC
      @subcoolHVAC 3 วันที่ผ่านมา

      I didn’t see fuses for the blower , the cfm relay is the weak link to the motors , the yellow motor leads remain energized through the cap common. They already have enough wires shoved into undersized contactors as it is 😂 Thanks for commenting

    • @jrsmyth9761
      @jrsmyth9761 3 วันที่ผ่านมา

      @@subcoolHVAC I run the yellows to the same side of the contactor as the common/yellow wire to capacitor is run from. If there is too much on there, they are not long enough or it is just easier then they stay on the capacitor. As for the fuses,, there is a block for them just above the VFD, at least on the units I have worked on. Again, maybe different on the higher voltage equipment.

  • @MarcosHVAC
    @MarcosHVAC 3 วันที่ผ่านมา

    I have a site with 32 carriers all 25 tons from 2020. We call it the Covid building. Numerous issues from factory that I caught on start up. Watch out for those insulated terminals for the drive. I had a few burn out on me this spring

    • @subcoolHVAC
      @subcoolHVAC 3 วันที่ผ่านมา

      Oh man, good to know . Thanks Marcos 👍

  • @ericbaker5619
    @ericbaker5619 3 วันที่ผ่านมา

    A bypassed VFD on a carrier? No way! I swear their VFD quality is terrible past few years

    • @subcoolHVAC
      @subcoolHVAC 3 วันที่ผ่านมา

      Lol, I guess 1 out of 6 isn’t too bad 😂

  • @Josh.SPublishingTeam20240
    @Josh.SPublishingTeam20240 3 วันที่ผ่านมา

    Hi, i am a new subscriber nice trobleshooting, the wire was crisp

    • @subcoolHVAC
      @subcoolHVAC 3 วันที่ผ่านมา

      Welcome to the channel 👍 yep, it was a little over cooked !

    • @johnpadua9115
      @johnpadua9115 3 วันที่ผ่านมา

      Looks like the sheaves opened up and motor over amped

    • @subcoolHVAC
      @subcoolHVAC 3 วันที่ผ่านมา

      Set screw was loose but didn’t look like it spun, I was thinking loose wire nut at motor possibly. 🤔

  • @ccthepope
    @ccthepope 4 วันที่ผ่านมา

    Great video! (as always)

    • @subcoolHVAC
      @subcoolHVAC 4 วันที่ผ่านมา

      Thanks CC 👍

  • @SonicOrbStudios
    @SonicOrbStudios 6 วันที่ผ่านมา

    Is that blue guy A2L compliant? I'm sure the Navac is because I just purchased it

    • @subcoolHVAC
      @subcoolHVAC 6 วันที่ผ่านมา

      I haven’t seen A2L compliant in writing on the Hercules but it has the features to be, DC Brushless motor, spark proof switch. Would need to verify with mfg. Thanks for asking!

  • @hvacrnortheastern2110
    @hvacrnortheastern2110 7 วันที่ผ่านมา

    Great job that surprised at they didn’t know chiller were off whole week or having problems l operate a #2 YK York 800 ton chiller we have alarm when chiller go off on an warning or any chiller pump and cooling pumps or any other problems we have the in the utility plant l guess that they doing a big project hated when they upgrade and the cause a problem due to the construction.

    • @subcoolHVAC
      @subcoolHVAC 7 วันที่ผ่านมา

      Yeah EMS doesn’t have alarms enabled at these sites during unoccupied or occupied times, building maintenance has to check physically… Thanks for commenting 👍

  • @wbforsure2104
    @wbforsure2104 7 วันที่ผ่านมา

    They're not the most powerful but the convenience of doing automatic ac jobs out in the field makes it priceless to me. No need for a generator, a converter or extension cord. I bought the 12ah battery so I'm curious how many cars i can do off it.

    • @subcoolHVAC
      @subcoolHVAC 7 วันที่ผ่านมา

      Nice, keep me posted how it does with 12ah. 👍

  • @stephenjenner484
    @stephenjenner484 7 วันที่ผ่านมา

    Only a good tech can make a repair. Any hack can take good equipment and through it in the junk . Those Rheem,Rudd, Weather Kings were good equipment .

    • @subcoolHVAC
      @subcoolHVAC 7 วันที่ผ่านมา

      The previous company only wanted to replace 😎

  • @lee-johnson
    @lee-johnson 8 วันที่ผ่านมา

    What was the subcooling before you added refrigerant? Nice work

  • @therealromster
    @therealromster 8 วันที่ผ่านมา

    Nice video, why didn't you diode test the 6 diodes in that bridge rectifier? A lizard alone wouldn't blow them high current relatively low voltages compared to thousands of volts lines. More than likely IGBTs are blown or the full wave bridge rectifier.

    • @subcoolHVAC
      @subcoolHVAC 8 วันที่ผ่านมา

      It was just the lizard, see part 2. Thanks for commenting 👍

  • @wayneguy6043
    @wayneguy6043 8 วันที่ผ่านมา

    Who wants to to put in a new 5 ton every 10-15 years for $18k

    • @subcoolHVAC
      @subcoolHVAC 8 วันที่ผ่านมา

      You could spend that much but not for a comparable replacement to this one . Thanks for watching!

  • @stevem1081
    @stevem1081 9 วันที่ผ่านมา

    They may save money now, but the unit being that old, they will be paying a lot more in the long run due to it being less efficient and more leaks are likely to show up again before long.

    • @subcoolHVAC
      @subcoolHVAC 9 วันที่ผ่านมา

      Ultimately customers decision

  • @nicolasmuniz9452
    @nicolasmuniz9452 9 วันที่ผ่านมา

    Looks like the H/F vacuum pump works great.

    • @subcoolHVAC
      @subcoolHVAC 9 วันที่ผ่านมา

      I’m using it where I can to keep testing 👍

  • @nicolasmuniz9452
    @nicolasmuniz9452 9 วันที่ผ่านมา

    Hopefully no fan, capacitor or compressor goes out in the near future they might blame it on you, usually no good deed goes unpunished, I've done a a couple of less expensive jobs to help a customer out and BAM! they call back that their water heater, on other side of house does not work a day after I repaired the a/c, this really happened to me, just told them to go kick rocks.

    • @subcoolHVAC
      @subcoolHVAC 9 วันที่ผ่านมา

      I did replace the capacitor, no guarantees when in situations like this. The owner is aware of the condition

  • @josephradford9665
    @josephradford9665 9 วันที่ผ่านมา

    What type of megaohm meter was that? Fairly new to HVAC and i appreciate the lessons

    • @subcoolHVAC
      @subcoolHVAC 9 วันที่ผ่านมา

      Fluke 1503 insulation tester, Thanks for watching! All the best 👍

  • @jwotham96
    @jwotham96 10 วันที่ผ่านมา

    Forgot the video, but what is your opinion on the compressor jackets? My unit has one and I still need to clean it.

    • @subcoolHVAC
      @subcoolHVAC 10 วันที่ผ่านมา

      Sound blanket? Not a fan… not sure what that has to do with cleaning?

    • @jwotham96
      @jwotham96 9 วันที่ผ่านมา

      @@subcoolHVAC didn’t think about it for sound reduction. I asked so when I go in to clean I could address it at the same time if it had a negative effect. Thanks

    • @subcoolHVAC
      @subcoolHVAC 9 วันที่ผ่านมา

      Gotcha, clean it sure or toss it 👍

  • @Jarrettsville_Garage
    @Jarrettsville_Garage 10 วันที่ผ่านมา

    Better make sure you keep an eye on your superheat. You get it too low you’re gonna flood a compressor

  • @kamranjutt9040
    @kamranjutt9040 11 วันที่ผ่านมา

    Good work👍 but if the leakage is close to metal part of condenser. It is better to carefully melt the surroundings of metal part touching copper u and then solder copper part No callback no complains . I work as an hvac technicion in kuwait .

    • @subcoolHVAC
      @subcoolHVAC 11 วันที่ผ่านมา

      You realize the end sheet melts at a higher temp than the copper, trying to melt that would destroy the copper. Thanks for the comment though👍

    • @kamranjutt9040
      @kamranjutt9040 11 วันที่ผ่านมา

      @@subcoolHVAC I have done it bro It needs super skills But any way your work is outstanding 👍

  • @mrsmith5114
    @mrsmith5114 11 วันที่ผ่านมา

    Wish you posted the prices.

    • @subcoolHVAC
      @subcoolHVAC 11 วันที่ผ่านมา

      Replacement would’ve cost 6-7 times as much if that helps

    • @mrsmith5114
      @mrsmith5114 11 วันที่ผ่านมา

      @@subcoolHVAC It does :) Thanks for the response. Donno why I watch all these repair stuff, but always interested in the prices. Best of luck!

  • @welrod94
    @welrod94 12 วันที่ผ่านมา

    I didnt watch the video just because I dont find it interesting when you have worked on and replaced god only knows how many units but I did wanna say unless they are stupid rich they are always gonna wanna repair over replacing the unit. I mean I'm the type of guy if my compressor blows up I wanna buy a new compressor than a entire unit😂 **even tho I didnt watch the comment will still help with the algorithm

    • @subcoolHVAC
      @subcoolHVAC 11 วันที่ผ่านมา

      Thanks for not watching but commenting 😎

  • @philipwalker1267
    @philipwalker1267 12 วันที่ผ่านมา

    Love my Hercules vacuum pump I use it on ice machine and walk in coolers and reach in coolers and on ac units . It’s not the fastest but it’s light and works like it should. Half the cost of other brands and just as good with a 5 year warranty on tool and three year warranty on battery and charger

    • @subcoolHVAC
      @subcoolHVAC 12 วันที่ผ่านมา

      Right on 👍 it gets those jobs done! Thanks for commenting

    • @philipwalker1267
      @philipwalker1267 12 วันที่ผ่านมา

      @@subcoolHVAC your welcome anytime!

  • @josemanuelsanchez-cuadrado9694
    @josemanuelsanchez-cuadrado9694 12 วันที่ผ่านมา

    Generally for medium commercial units like that in video takes more than 10 minutes so there is missing facts about the performance on the Navac 2 cfm pump. Is my opinion on that matter😅

    • @subcoolHVAC
      @subcoolHVAC 12 วันที่ผ่านมา

      I believe that was a 3 ton residential unit

  • @MarcelHVAC
    @MarcelHVAC 12 วันที่ผ่านมา

    Great job, what was the smoke coming from the condensor? Dirty condensor or was it oil from then refrignant lines burning? Like your oldschool scale, i bet it will survive you!

    • @subcoolHVAC
      @subcoolHVAC 12 วันที่ผ่านมา

      It was a combination of leak detector liquid boiling off and may have been residual oil on the coil from the initial leak. Yep, the scale will outlast me 👍

  • @user-de8fi2ih3s
    @user-de8fi2ih3s 12 วันที่ผ่านมา

    Nice job!!! what a difference a clean coil makes...

    • @subcoolHVAC
      @subcoolHVAC 12 วันที่ผ่านมา

      Yes indeed!

  • @MindzEnt
    @MindzEnt 12 วันที่ผ่านมา

    All depends on how much you charged them, if you go around making leak repairs for 500 bucks of course the owners will go with repairs.

    • @subcoolHVAC
      @subcoolHVAC 12 วันที่ผ่านมา

      Where did you get $500 ?

  • @jasonjohnsonHVAC
    @jasonjohnsonHVAC 12 วันที่ผ่านมา

    Been busy....just catching up on videos.....keep it bro...I enjoy the content and the channel

    • @subcoolHVAC
      @subcoolHVAC 12 วันที่ผ่านมา

      The Heat is On 🔥 Thanks Jason 😎

  • @DabblelyDiddly
    @DabblelyDiddly 13 วันที่ผ่านมา

    funny, most window units still use copper. besides the midea 5k

  • @R290s_biggest_fan
    @R290s_biggest_fan 13 วันที่ผ่านมา

    I would have stuck a fork in it and moved on, good job though.

    • @subcoolHVAC
      @subcoolHVAC 13 วันที่ผ่านมา

      Thanks de minimis bucket 🪣 ! Great name 👍

  • @davidnull5590
    @davidnull5590 13 วันที่ผ่านมา

    Thanks for the video, it was interesting. Was there a huge difference in price between a repair and replacement? thanks,

    • @subcoolHVAC
      @subcoolHVAC 13 วันที่ผ่านมา

      Thanks David, would’ve cost at least 6x the $ to replace , ultimately it’s customer decision 👍

  • @alabamahvacprofessional2946
    @alabamahvacprofessional2946 13 วันที่ผ่านมา

    Just watched the video, and want to say thanks for repairing the problem. I have 37 years of experience in the field, and most guys these days only want to replace the entire system.

    • @subcoolHVAC
      @subcoolHVAC 13 วันที่ผ่านมา

      Thanks Alabama HVAC!

  • @OIC-es6pi
    @OIC-es6pi 13 วันที่ผ่านมา

    Nice work.

    • @subcoolHVAC
      @subcoolHVAC 13 วันที่ผ่านมา

      Thanks!

    • @subcoolHVAC
      @subcoolHVAC 13 วันที่ผ่านมา

      Thanks!

  • @TrustedHVACR
    @TrustedHVACR 13 วันที่ผ่านมา

    I would be challenged to do that without burning a hole through the copper … any suggestions?

    • @subcoolHVAC
      @subcoolHVAC 13 วันที่ผ่านมา

      Yep, clean the u-bend with sand cloth, small light flame and keep it moving with brazing melting over it. I use Stay-silv 6% . Had to stop the nitro because it was popping holes, but got it to close. You can do it. 👍

  • @ericbaker5619
    @ericbaker5619 13 วันที่ผ่านมา

    Some guys can really perform art with a mixed torch. Good job bud.

    • @subcoolHVAC
      @subcoolHVAC 13 วันที่ผ่านมา

      Thanks Eric 🔥

  • @divine4fi244
    @divine4fi244 14 วันที่ผ่านมา

    They dont make them capacitors like they used to 😅

    • @subcoolHVAC
      @subcoolHVAC 14 วันที่ผ่านมา

      Definitely not !

  • @Paul-IE-Repairs
    @Paul-IE-Repairs 14 วันที่ผ่านมา

    ive seen several systems installed without a dryer, when the lineset is less than 10ft long. i dont think that is the case in this situation. did someone put a hard start on a scroll compressor smh....

    • @subcoolHVAC
      @subcoolHVAC 14 วันที่ผ่านมา

      They provide a drier with those units, none was put in when the evaporator was replaced either 🤔.