- 58
- 134 769
Roxxofoxxo
United States
เข้าร่วมเมื่อ 16 พ.ค. 2019
Oh hey! I'm just a random furry on the internet that happens to be interested in fire alarms and life safety devices. I mainly post fire alarm content/life safety-related content but sometimes I'll occasionally post a vid that's not related to fire alarms such as something tech-related. Even though I am a furry I will rarely ever make furry-related content so if you're expecting furry content this isn't the channel.
Feel free to stick around if you like, and if you want you can sub to me.
pfp drawn by @ Argyle199 on Twitter.
Feel free to stick around if you like, and if you want you can sub to me.
pfp drawn by @ Argyle199 on Twitter.
Simplex 4007ES Demo Board Test 2 - Two Stage!
Here's a PDF of my custom control equations for two-stage and my alert horn strobe. For the fast reset, it works on other Simplex panels as well, not just the 4007ES.
drive.google.com/file/d/1d-YHaVjLl_6WygIsf_KbXLPCjg1K78T_/view
drive.google.com/file/d/1d-YHaVjLl_6WygIsf_KbXLPCjg1K78T_/view
มุมมอง: 598
วีดีโอ
Simplex 4100ES IDNAC updates
มุมมอง 6635 หลายเดือนก่อน
So, I didn't really have anything that eventful to upload, but I finally got IDNAC after wanting it for a long time, so that's a plus.
Simplex 4100ES Home System Test 1
มุมมอง 5Kปีที่แล้ว
Well I am back after a long hiatus of not uploading TH-cam videos this system test wasn't anything too eventful; I just changed the speaker strobes and finally got an ES CPU. If you guys have any suggestions for videos you want to see lemme know!
Simplex 4100U Home System Test 1
มุมมอง 9K2 ปีที่แล้ว
Thanks for watching and thanks to all the amazing people who helped in making this system possible! Here's a channel link to Nick's Mad Science www.youtube.com/@NicksMadScience/featured And here's where you can find his voice messages nickpiegari.com/misc/firealarmmessages/ Please don't ask me for Simplex programming software because I will not be giving that out for obvious reasons.
The Final Test Of The Notifier NFS2-640
มุมมอง 7142 ปีที่แล้ว
Yep, so as I said in the video, I'm probably going to get a 4100U so stay tuned for that!
Simplex 4007ES Demo Board Test 1
มุมมอง 3.8K2 ปีที่แล้ว
Thanks to everyone that helped me with my 4007es and get it to normal! Here are all the wonderful people that joined the VC to watch the first test of the 4007es! th-cam.com/users/FireAlert th-cam.com/channels/LlQEUBINzPr-PvDHdcnEDw.htmlfeatured th-cam.com/channels/_Cqp1PRNzFesemdlP6_xcw.html th-cam.com/channels/uIC71XQUYXT_-ww41d6A8g.html th-cam.com/channels/ribR9WyDh-T4eZwCO7m-Bg.html th-cam....
Notifier nfs2-640 home system test 3
มุมมอง 8622 ปีที่แล้ว
Sorry for the crappy/boring video, it's just that there isn't really anything to show since last system test. People wanted to see the Nca 2 in action though so I decided to post this. I've been pretty busy with school and life so I haven't been able to upload system test more often.
Simplex 4007es Unboxing
มุมมอง 2782 ปีที่แล้ว
Just as I said in the video, yes I do have the software for it but please do not ask for it. I WILL NOT SHARE IT
How To Connect a NCA 2 to a NFS2 640 Without Verifire Tools
มุมมอง 6K2 ปีที่แล้ว
How To Connect a NCA 2 to a NFS2 640 Without Verifire Tools
The Simplex 4007es at school having a stroke
มุมมอง 3.6K3 ปีที่แล้ว
The Simplex 4007es at school having a stroke
Notifier nfs2-640 system test 1 with Mimi2!
มุมมอง 4293 ปีที่แล้ว
Notifier nfs2-640 system test 1 with Mimi2!
Honeywell Vista20 and Silent Knight 5820XL test
มุมมอง 7103 ปีที่แล้ว
Honeywell Vista20 and Silent Knight 5820XL test
Silent Knight 5820XL basic wiring and programming
มุมมอง 11K3 ปีที่แล้ว
Silent Knight 5820XL basic wiring and programming
Where did you get the “NOT TO BE OPERATED BY F**KWITS” sign?
LCD80 SUPERVISORY FAULT HATANA HAI KAISE HATAYE
I like the older ones that have Kobishi horns more.
Bro sound like fart nice
Is it a conduit bender?
Why did you downgrade the system from notifier to simplex. My school went from simplex to notifier.
California Code What’s That.
Cool! A touchscreen FACP! :3
"Its been forever since I recorded a video" welcome back
Nice demonstration! Oh btw, wasn’t this panel bricked or did something else die on it? Also, I did have a problem with my 4007es system where the Truealert es av quit working randomly and wouldn’t sound unless you manually turned it on through the panel. I found out the reason why was due to bad device firmware as devices that matched mine’s date code had been flagged for defective firmware. I tried firmware upgrading (I had help from an experienced person and didn’t brick my panel) and the “software fix” that simplex put out for these devices but ultimately I ended up just replacing the device.
woah very cool
bro's back from the dead, that space age annuciator is cool
Notifier is better
No way A part 2 roxy video for the first time in 2 years So crazy
Nice!, Its my birthday and i just got my hands on a 4099-9006!
Here's a PDF of my custom control equations for two-stage and my alert horn strobe. For the fast reset, it works on other Simplex panels as well, not just the 4007ES. drive.google.com/file/d/1d-YHaVjLl_6WygIsf_KbXLPCjg1K78T_/view
Sounds Dutch lol
Yup. Just had that same thing happen today. panel has been in for three months now and this happens. Only one smoke on that slc loop. At least they gave me a case number.. Told me to do a default first. I'll do it but not expecting in to change anything.
10:57 Dang thats a NASTY Scar! If you dont mind, What did you do?
I cut my arm on glass on a broken window while exploring an abandoned hospital lmao
@@Roxxofoxxo Dang! I Hope it will get better!
@@alrmfire1 ayy thanks
@@Roxxofoxxo No Problemo!
Very informative. Thank you
Wonder if you could get all the 4100 classic and plus tones on the panel
I thought youd never upload again
I need the audio rip of that
Simplex 4100ES is NOT to be operated by fuckwits.
Hell yeah
holy crap you're alive
Me just realizing I'm technically subbed to a furry: 0__0 Really cool though!
Yooo awesome! I've always wanted one of those idnac speaker strobes even though I can't run it on anything! I do wonder where you got one, but they are awesome.
I really do wonder who got this for me... (thanks btw)
@@Roxxofoxxo :3
Yay the fire alarm fluffer is back :3 This is awesome, I do love IDNAC, one of the coolest technologies in the life safety field
Welcome back!
Simplex 4100ES.
Simplex 4100ES.
Simplex 4100ES.
5:55 That is the same exact message that my middle school used on its 4100U system, except they used the male voice.
So basically you took out the home system and patched it entirely? If so rip, but demo boards are more able to be changed
Yeah, the holes on the home system have all been patched up, no panel took it's spot.
IDNAC!
The latest and greatest by Simplex 💯
@@Roxxofoxxo ✅
1:05 Wow I didn’t know that 4007’s were prone to dying. My school district has had 4007ES systems in 5 out of its 7 elementary schools for around 10 years now and has had zero issues with them. I guess they are just lucky.
4007ES's are prone to failure during software updates for some reason, if you don't update them or mess with them often they should be fine...my school's 4007es did freak out once or twice though, as seen here th-cam.com/video/i3Qb5wqnJXo/w-d-xo.html
S.E.R safety is going to see this
Aw man I'm so happy my voice made it onto a real 4100 system :D Really cool homelab-type setup!
Tyty!!
there is some reason we need to shutdown this control box. how do we do it? and how to turn it on again when we want to use it ?
U have to disable it when u go up to it there should be a control box that’s blinking unscrew the 2 screws and there should be 2 knobs one should say ten and one’s depends on how many devices for example u have device 9 on the loop or device 109 that means 10 is in the tens and 9 is in the ones then u go back to the to the panel and go into settings and enter 109 or 9 when it says enter point enter the number that it says at the control box then u should be ready to go if u don’t understand just unplug power or unplug SLC when u need to disable it
He's probably tired of it constantly going off
How add device by zone or address
The baseball stadium I work at as a mascot performer was initially built in 2002 with a Notifier AFP-100 system, and the NBG-12LX pulls in the enclosed areas blinked red on the CLIP protocol. But in early 2018, the AFP-100 was replaced with an NFS-320 panel, and the existing NBG-12LXs started blinking green due to the FlashScan protocol. Aside from that, and the annunciators and the outdoor elevator recall heat detectors, everything else was unchanged (including the REALLY loud and piercing Wheelock AS horn/strobes).
Shoutout to our tech furries for delivering us the content we need 🙏
nfs 320 next plz
I need you help..
Excellent system!!
Ayyy thanks!!
I cant seems to get to the " change program " menu, even im using the correct password. It just gets back to the home screen. Sometimes it works but most of the time not. 1:32 . I know that its not a wrong password since it doesnt shows error it just simply puts me back to home screen.
Simplex 4100ES
Woah, you got idnac?? That's awesome! Also amazing speaker strobe. I always wanted one of those lmao
I wonder who gave me that speaker strobe... :p