THANKU Sir Aap. Interview ke Related jitna Bhi Video Banaye hai Sab dekha hu Sab ka samajh me aa jata hai but Plumber or STP operator ka video samajh me nahi aata hai pata nahi kiyo Me Soch Raha hu Aapk Jis Side PE job kr rahe hai me Waha 6 month job Karu taki sab kuchh Sikh lu
there is not a specific formula. It depend on building's type. watch it, you will find answer. th-cam.com/video/kEBaqMtiV9M/w-d-xo.htmlsi=QfJv57Y4OBjjQlI1
Sir mainly we didnt have btw meter so pls explain it with defination and also ikw of chiller. And min and max value of cop and ikw of chiller. And also i m always confused in sanction and demand load of building. Pls explain. Hope you will explain this too.
@@BuildingSanchalan sir, ikw-cop ka sayad ulta nahi hota kya?,kyuki cop ki value jitni badi hogi utni acchi hogi aur ikw ki value jitni choti hogi utni achhi hogi,pls correct me if it is not..
Sir Good Evening, Mere Pass one question hai is topic se alag hai , hamare pass HVAC plant ek 30 kw ke condenser motor hai uska panel side se , star delta ka 6 wire jo panel pe hai , wah hamesha heat hota , continously Burn hota hai , Hamane sare option try kiya Jaise 1- motor current each phase ok as rated current Pls. App kuch suggestion dijiye hai. Ki problem ko permanent resolve kar sake. Regards Jai
Sir दो chiller unit hai 120 120 TR ke दोनो pr लोड 70 परसेंट से कम है but discharge discharge pressure 150, 152 जा रहा है और कूलिंग टावर से पानी 34, 36 डिग्री a rha hai दोनो CT fan चालू होने के बावजूद प्रोब्लम का सॉल्यूशन कया है सर
Sir Dief controller ke baarei mein bhi bataiyee, interview mein kaii baar poocha gaya hai, jawab nahi de paaya hu, pls help me😢😢.. kei comments kiye hai,pls make it for God sake...
Main performance parameter is ikW/TR and it is define by ratio of power input to compressor divided by tons of cooling produced. Lower ikW/TR indicates higher efficiency. COP and IKW are same thing.
Sir I appreciate your efforts.salute you you're the great.❤❤
So nice of you
Excellent sir, also please explain load calculation of Heat
Which electrical load do i calculate only chiller or all accessories like secondary, primary, condenser pump and ct fan motors
only chillar plant
Sir very good job
Regards
Ashwani Kumar
tx
Nice topic sir ❤🎉
Thanks for liking
Exallent class sir ❤
thanks dear
Sir Cop centrifugal or screw, reciprocating ka range kitna hona chahiye
Great ❗❗❗ beautiful
Thank you! Cheers!
Good work sir g
Thanks
Very nice sir ji
Thanks
Aap sahi se samjhate hai sir ji
thanks
Cooling tower evaporation loss and blow down losses and drift loss kaise Nihal Sauter hain?
th-cam.com/video/f4P_uvG2OdI/w-d-xo.htmlsi=mZj-5SSt1OP9SSH- many more video related to blow down etc in chanel please visit Building Sanchalan
Thank you sir for your information 🙏
So nice of you
Bro please tell me the electricity consumed by the chiller including all the primary, secondary pumps and condenser pumps?
It will depend on plant capacity.
Sir what is range of cop for good chiller plant
40% to 60%
Very nice
thanks
Sir Chillier plant Cop or IKW diffrence with example
It is little bit different. IKW is which electricity consume in 1 TR refrigeration generate. KW energy in per ton refrigeration.
What is the approach temperature and why it's going high..?
th-cam.com/video/1b8CxFeZwFI/w-d-xo.htmlsi=qysOl5A9DM7M8ZAY watch it
BTU /hr ye btu meter me kaise milega yani muje btu meter per 2.241kwh dikhata he to btu/ hr kitna
Sir COP limit kay hoga
What should be the limit of COP of chiller
It depends on the plant condition and maintenence. Limit is 40% to 60%
Thanks Sir
Sir btu meter se every ahu k pass jayenge btu check krne k liye
Jab chillar plant per na ho tab.
Sir agar BTU meter na Lage ho to kaise nikalte cop ko please reply
Isi tarike se nikalte ha
THANKU Sir Aap. Interview ke Related jitna Bhi Video Banaye hai Sab dekha hu Sab ka samajh me aa jata hai but Plumber or STP operator ka video samajh me nahi aata hai pata nahi kiyo
Me Soch Raha hu Aapk Jis Side PE job kr rahe hai me Waha 6 month job Karu taki sab kuchh Sikh lu
dobara dekho aur jo samajh me na aaye usko practically dekh kar try karo ya mail karo.
Very nice dir
Thanks a lot
Sir kisi chiller ka capacity lekar ex.sajhaye please
Sir cop kitna se kitna k bich m hona chahiye.
4 to 6
@@BuildingSanchalan sir approach temperature kitna se kitna bech m hota h
Or saturation temperature kitna se kitna hona chahiye.plz dono question ka answer bataye
Is cop and ikw is same
yes
Ikw kya hota h sir
Sir ETP Plant me as per Government rule ph value limit kay hoga
7.5
Dear Sir, what is the formula to calculate the CAM bill of a Building?
there is not a specific formula. It depend on building's type. watch it, you will find answer. th-cam.com/video/kEBaqMtiV9M/w-d-xo.htmlsi=QfJv57Y4OBjjQlI1
Hi sir what are the design parameters of cop, i meant how we understand that our cop is good or not.
For water cooled chiller the minumum COP is 4.2
Sir plant ki kitni Cop best rahti h
4 to 6
Sir mainly we didnt have btw meter so pls explain it with defination and also ikw of chiller. And min and max value of cop and ikw of chiller. And also i m always confused in sanction and demand load of building. Pls explain. Hope you will explain this too.
IKW and cop are same. sanction load is contract load, demand according to our connected load and maximum demand.
Sir ct ke water(tds/PH etc) ke baare me to video bnaya hai aapne but chiller water(tds/pH etc) ke baare me bhi ek video upload kariye sir please 🙏🙏🙏🙏🙏
Chiller water me soft water use kiya jaata ha jo soft water ke parameter ha wahi rahenge.
@@BuildingSanchalan thank you sir🙏🙏🙏
Sir but kaise naapte hai is par bhi video banaye
Sir,ikw kya hota hai
COP ko hi IKW/KWR bhi kahte ha, same ha
Yes sir IKW pr ek details mai video share krne please
@@BuildingSanchalan sir, ikw-cop ka sayad ulta nahi hota kya?,kyuki cop ki value jitni badi hogi utni acchi hogi aur ikw ki value jitni choti hogi utni achhi hogi,pls correct me if it is not..
Sir sp gravity par 1 video banao
Thanks sir ❤❤❤
welcome
Please shared the complete sheet with calculation
USGPM ko kese convert karte hai
1 GPM=3.785 liter per minut
Nice sir
Thanks and welcome
Sir chiller ki COP ko impact karne Wale reason ya parameters kon kon se ho sakte hai?
Poor maintenance of condensor, cooling tower, poor quality water, damage mechenical iterms etc.
Sir five S ka kiya matlab hota hai
5S japanies teqniqe ha cleaning ki jo manufactuaring unit me use hoti ha.
Sort-set in order-Shine-standardise-sustain.
Sir Good Evening, Mere Pass one question hai is topic se alag hai , hamare pass HVAC plant ek 30 kw ke condenser motor hai uska panel side se , star delta ka 6 wire jo panel pe hai , wah hamesha heat hota , continously Burn hota hai ,
Hamane sare option try kiya
Jaise
1- motor current each phase ok as rated current
Pls. App kuch suggestion dijiye hai.
Ki problem ko permanent resolve kar sake.
Regards
Jai
please check wire size once and tight all connection in every week. Wire/ cable should be copper then problem must be resolve.
Vantilation problem ho sakta h
Sir दो chiller unit hai 120 120 TR ke
दोनो pr लोड 70 परसेंट से कम है but discharge discharge pressure 150, 152 जा रहा है और कूलिंग टावर से पानी 34, 36 डिग्री a rha hai दोनो CT fan चालू होने के बावजूद
प्रोब्लम का सॉल्यूशन कया है सर
Dirty condensor, You need de scaling of both condensor.
Sir pls make a vdo on ETP
th-cam.com/video/tIMK9A651S8/w-d-xo.htmlsi=fLwPdtktmlZ2MH1o
Sir Dief controller ke baarei mein bhi bataiyee, interview mein kaii baar poocha gaya hai, jawab nahi de paaya hu, pls help me😢😢.. kei comments kiye hai,pls make it for God sake...
OK pankaj. I will try but it will take time.
@@BuildingSanchalan thanks sir waiting for your video
SOP ke bare me bataye sir fm me
🎉🎉🎉
Thanks
❤
welcome
Sir - Kindly brief about IKW of chiller
Main performance parameter is ikW/TR and it is define by ratio of power input to compressor divided by tons of cooling produced. Lower ikW/TR indicates higher efficiency. COP and IKW are same thing.
Cop= 5.86 Good Kitna hona chahiye
Min-4 to Max 5.5
सर एस टी पी के बारे में आपके जैसा जानकारी पाने के लिए कौन सा कोर्स करना पड़ेगा प्लीज जवाब जरूर दीजिएगा
Dost koi course ni ha alag se practice and learn.
@@BuildingSanchalan aap se mil sakta hai
सर hvac टेकनीशन विदेश का इंटरव्यू में क्या क्या qustion किया जाता है इनपोटेन क्यूशन में वीडियो बनाए plz सिर।।।।।
विदेश में क्या रखा है भाई
th-cam.com/video/zTEJc2xPi0Q/w-d-xo.htmlsi=bEfuB430J8gmK54F watch it, everywhere technical interview questions are same.
The Whole world is ours.
Aapke under Bahut Nolage hai
Esa ni ha ji. sab yahan hi seekhte ha.
🎉🎉🎉