Sir, I am Dealing in the Chemical Free Solution for Cooling Tower. Patented ECOMax CT water treatment for Cooling Tower. Nice Explanation. I just save your VIDEO for future References❤
Why we check the M. Alkalinity and P. Alkalinity. Both of above titrations we can use only one or both. If the M and P. Alkalinities are not within the limit what we do. What type of chemicals we are you use.
Do you recommend side stream filter to maintain TDS of cooling water ? what is blow down percentage of coolng tower?.whatcis efficiency of cooling tower ?
सर नमस्कार, सर शायद पानी का अम्लीय या क्षारीय होना का ज्यादा या कम होना pH पर निर्भर करता है...आपने कहा की हार्डनेस से ऐसा हो सकता है... इसमें कन्फ्यूजन हो गया....क्योंकि एक बार टेक्निकल जीएम सर ने इंटरव्यू के दौरान मुझे बताया कि यदि हार्डनेस 0 पीपीएम होगी तो कूलिंग टावर के लिए अच्छा होता है और कंडेंसर में स्केलिंग भी नही होगी क्या यह सही है.....? जरूर बताएं सर जी
सॉफ्ट वाटर जीरो हार्डनेस का हो सकता है लेकिन कूलिंग टावर में भरने के बाद जैसे ही हम कूलिंग टावर चलाते हैं तो जीरो हार्नेस नहीं रहती पानी छारीय है या अम्लीय इसके लिए cooling tower playlist mein वीडियो देख लो
1 - 14 to pH value hai sir lekin ye nhi samjh aarha 150,50,30 450 ye sb ko kya bolenge ,jaise 1 likh diye to ye pta nhi chl rha ye ft mai hai ya mm mai hai ya inches .wo jo aap likhe hai kya likhe hai
Hard water is usually defined as water, which contains a high concentration of calcium and magnesium ions however some other desolved metels, those forms divalent or multivalent cations, including barium, iron, strontium, zinc, aluminium and magnese.
Sir, if total hardness- 2000 Cl- 1800 TDS- 5000 then how many ppm dose should be of antiscalant, corrosion inhibitor & dispersant?? Please suggest 🙏🏻🙏🏻
TDS ,Hardness per antiscalent kam ya jyada limit ke according kar sakte ho, corrosion ph per depend karta h aur bioside algae/ kai ke liye hota h. Sabhi chemical water ko permissible limit me rakhne ke liye hi add kiye jaate h, inki quantity fix nahi hoti accordingly change ki jaa sakti h yadi tumhe limit pata h too
सर जो आप बताते हो । वह इतना अच्छा बताते है ।आप के अलावा और विडीयो को देखने मन नही करता है । कयोकि आप इतने विस्तार से बताते है । कि समझ मे आ जाता है। हर चिज बारिक से बताते है ।
Very nice
Ryt
आपका समाजाने का तरीका बहुत ही अच्छा है। sirf cooling tower me pani add karana Janate the Hum lekin aapane bahut kuch achha sikhaya.... thank u so much
So nice of you
आपकी सभी वीडियो बहुत अच्छी होती हैं और आपका समझाने का तरीका कबीले तारीफ है
थैंक्यू सर
बहुत ही सारानीय वीडियो सर जी🙏🙏🙏🙏🙏
😲Wow what a knowledge you had sir that's mind blowing keep it sir being subscriber I am proud of you
Sir, I am Dealing in the Chemical Free Solution for Cooling Tower.
Patented ECOMax CT water treatment for Cooling Tower.
Nice Explanation.
I just save your VIDEO for future References❤
Thanks for viewing, I will share your reference to concern
Very nice performance sir ji 🙏
You are an excellent teacher 👏
Thanks but I m engineer.
Thank you sir for your information 🙏
Good knowledge sir
Awesome 👍
Thanks 🤗
Awesome video sir
Very good sir ji
Sir how many types of valve use in firefighting, plumbing, and chiller syster and why? Please make video
Gure Dev🙏🙏🙏
Masaallah satsatnaman ....
Could you please add English subtitles? It would be super helpful for viewers like me who are not Hindi native speakers. Thank you.
Thanks for comment, will try.
Nice sir
Osm...but sir..I think the best tds for cooling tower sump may be 1000-1500
Yes, it can be best but as standard in the video
Yes, it can be best but I told as standerd limit
Sir,kya aap pot stainer k bareme me full detail video bana sakte hai?
Namste sir ji
I'm sachin
AAP ki padai aachi lagi
Thanks
Thanks Sor
Cycle of consentration (COC)
Total disolves solid (TDS)
potential hydrogen( PH)
Total hardness (TH)
You want to ask or tell?
@@BuildingSanchalan I write abrivationa If some one wants they can. Good explaination from you ,like you bro
Thank you sir
Why we check the M. Alkalinity and P. Alkalinity. Both of above titrations we can use only one or both. If the M and P. Alkalinities are not within the limit what we do. What type of chemicals we are you use.
Dear sir
Cooling tower m po4 (phosphate) ke bare m btaye
Sir, mee condasate ka pani cooling tower me le sakte hai ya naji 😊
no
Heat exchanger primary secondary delta T kitna hota h es par video bnaye
heat exchanger kahan use kiya ha ?
Thank you
Please make a video onPressure reducing valve working and settings
Do you recommend side stream filter to maintain TDS of cooling water ? what is blow down percentage of coolng tower?.whatcis efficiency of cooling tower ?
th-cam.com/video/f4P_uvG2OdI/w-d-xo.html
Sir close circuit me
Hum maxigard or colent dalty hn khud bana ho to kia use karein
Tumhara message clear ni h
Thanx sir
Ye kon sa device water check
pubg khelane wale aur party video se bhi achha lagata hai aapake video dekhana ab mujhe kyoki mera salary achha badha thank u
Thanks dear,
Apne friends ko bhi share karo jisse wo bhi seekhe
❤️
Sir,
plz make the video on HVAC Interview
Tq sir
Kya yahi properties Air Cooled Chiller k chilled water me nhi hota hai?
this is a cooling tower video but in air cooled no cooling tower.
These parameters of which plant in India?
Because these are too much high, what is your condenser tibe leakage ratio?
Sir chilled water of parameter ka bhi bana do sir.ya ye same parameters hota h
th-cam.com/video/cklNejj6aVo/w-d-xo.html chiller water parameter
What is the unit of this all ppm. Or ppb sir??
Both are unit. PPM= part per million and PPB= part per billion
Sir wire size to amp par ek video banado..
Sir pls video made with unit
Please tell how to calculate mbbr media.quick thumb rule
Sir mera plant me C/T water ka
Tds-300-900
TH-50-200
PH-7-8.5
Kya ye sahi hai?
Chiller ka cooling tower hai
100 percent
Sir above you mention all parameters but how to check
Please sir tell instruments name
Temperature meter, TDS meter, Hardness Meter etc.
Sir softner me ressine topup kyse kr
सर नमस्कार,
सर शायद पानी का अम्लीय या क्षारीय होना का ज्यादा या कम होना pH पर निर्भर करता है...आपने कहा की हार्डनेस से ऐसा हो सकता है... इसमें कन्फ्यूजन हो गया....क्योंकि एक बार टेक्निकल जीएम सर ने इंटरव्यू के दौरान मुझे बताया कि यदि हार्डनेस 0 पीपीएम होगी तो कूलिंग टावर के लिए अच्छा होता है और कंडेंसर में स्केलिंग भी नही होगी क्या यह सही है.....? जरूर बताएं सर जी
सॉफ्ट वाटर जीरो हार्डनेस का हो सकता है लेकिन कूलिंग टावर में भरने के बाद जैसे ही हम कूलिंग टावर चलाते हैं तो जीरो हार्नेस नहीं रहती पानी छारीय है या अम्लीय इसके लिए cooling tower playlist mein वीडियो देख लो
th-cam.com/video/Aj4tKJDPgQ0/w-d-xo.html
Sir ppm kya hota hai
Part Per Million
Par per million
Ph = potential of hydrogen
Sir TDS ki unit kya hoti he
PPM( Part Per Million)
Sir ppm kiya hai
th-cam.com/video/haD1yIgS0Fs/w-d-xo.html watch this video for PPM
1 - 14 to pH value hai sir lekin ye nhi samjh aarha 150,50,30 450 ye sb ko kya bolenge ,jaise 1 likh diye to ye pta nhi chl rha ye ft mai hai ya mm mai hai ya inches .wo jo aap likhe hai kya likhe hai
mm
Sir aap ye to bata rahe ho range kitni honi chahiye pr kyo honi chahiye ye nahi bata rahe ho practically kya nuksan ke kam jyada hone ke
definately line kharab na ho aur cooling tower quality ke saath lambe samay tak chale
Sir up ke sath bat karna hai lekin kaise karu please help me
Apna no mention karo aur mail me.
Sir hmara ph 2 aa Raha hai to kya Karna chahiye
Interview me questions Kiya tha please replay
P alknitiy full form
Phenolphthalein Alkalinity.
100 1000 kya samjh nahi Aya 100 psi ya 100 °c
++
Water m manganese hardness bnata h 👍 kya kya bol rhe ho sir 😆
Hard water is usually defined as water, which contains a high concentration of calcium and magnesium ions however some other desolved metels, those forms divalent or multivalent cations, including barium, iron, strontium, zinc, aluminium and magnese.
Thanks for watching my video and asking your doubt but way of asking is little bit strange.
Thanks
Sir, if
total hardness- 2000
Cl- 1800
TDS- 5000
then how many ppm dose should be of antiscalant, corrosion inhibitor & dispersant??
Please suggest 🙏🏻🙏🏻
TDS ,Hardness per antiscalent kam ya jyada limit ke according kar sakte ho, corrosion ph per depend karta h aur bioside algae/ kai ke liye hota h.
Sabhi chemical water ko permissible limit me rakhne ke liye hi add kiye jaate h, inki quantity fix nahi hoti accordingly change ki jaa sakti h yadi tumhe limit pata h too
Hardness unit kya hai sir?
Sir unit toh likho
For what
Kiski unit chahiye
Sir apna number send karo do
Sorry boss,
Mail me if anything.
++