Well explain sir 30XA carrier chiller use krte hai 134a refrigerants hai Discharge pressure 200 psi m agr nhi jta it's means compressor load p nhi hai to fir 150 psi m ap bol rhe cut of hoga
What is motor kw /TR ratio for R134a. What is interstage pressure in COMPRESSOR? what is efficiency /cop of chiller. What is flow rate chilled water, brine as per thumb rule per TR of plant?
Koi khaas fark ni hota bus jis industry me kaam karte han usi type ki machinery ki knowledge hoti ha bus itna fark ha. Mostly electrical work same hota h.
Sir cooling tower me wet bulb temp aour chiller condenser water entering temp ka kya mtlb hai jaise cond entering temp 29c hai to wet blub ka temp kitna hona chahiye
Wet bulb temperature environment temp ha jo wet thermameter ki sahyata se check kiya jaata h, yadi jyada janan chahte ho to cooling tower paylist me video dekh lo.
Condesor water pressure cooling tower distance ke anusar aur machine ke anusaar hota ha ..th-cam.com/video/Aj4tKJDPgQ0/w-d-xo.htmlsi=ccl-AmRN0Fz6VbpM watch it
super heat me sir dout hai ...pls fir se samajana .......super heat = refrigerant suction temp - evaporator saturation temp ............matlab suction temp .and saturation temp difarance ..galat hai ya sahi o batana
Superheat is measured as the difference between the actual temperature of the refrigerant vapor and the saturation temperature of the refrigerant at that same point. Your comment is right.
Sir mere plant me Trane chillers h or un ka chilled water pressure 4 kg rakha jata h 3 kj pr plant trip ho jata h or aap bta rahe h ki 1 se 2 kg rakhna h aisa q ???
First check safety kon si active ha. yadi normal ha aur sabhi parameter sahi ha tab safety reset karne ke baad start kar sakte ha. Parantu pahle alarm check karenge aur trip kyon hua use door karen.
❤❤❤
Well explained
Sir, u are ocean of knowledge
So nice of you
Good 👍
thanks
Thanks for sharing such a great knowledge
So nice of you
Very nice video 👍👍👍
Very well explained 👏 pls keep the good work up
Thank you, I will
Well explained Sir
Thank you ❤️
Glad you liked it
Great sir 👏
Suprb🎉
Thanks 🤗
Well explain sir....
Very good explain boss lot's thanks
His definition of Super Heat is absolutely wrong.
Good sir
Thanks, Pls mention your name in English.
Very helpful video Dear sir
thanks
Great sir
Thanks sir, for clearing my doubt in the chiller
Regards
Ashwani Kumar
Always welcome
Nice sir🙏
actually Superheat ki Definition me thoda Doubt lag rha hai
Superheat mean
THE outlet temp - Suction temp
Ref. Temp. Outlet from cond.- ref temp. outlet from TXV
Very well explained
Thanks for liking
Yes
Thanks
🙏🙏
Great sir❤
Thanks
Sir , next time
2 Unit me Explain karne ki koshi kijiye
pressure = PSI and Kpa
Temp = C and F
Cufick minte cfm.
Good explain
Thanks for liking
What is the corresponding temperature
Nice jankari sir ji
Thanks
Sir air cooled chiller ke bare Mai bhi bataye
Sir , loss of communication fault kis karan se aat hai chiller me ? Carrier 470 TR ke chiller me ye problem aah rahi hai
Sir central air conditioning plant ko operate kaise karte hai uski bhi ek series banao please
Good video sir. Please 3 phase chiller ki control wiring par video banayen.
Thanks Mr Sahab singh. Sorry for control wiring video.
How to calculate power consumption of motor. Which refrigerant is most efficient? (energy consumption less)
Which refrigarant have low pressure..like R134a&R600 theses due to low pressure , power consumption also less .
Really I am impressed with your explanation thank you
You are most welcome
I hope this exclusive for water cooled chillers with screw compressor sir or is it different for every compressor
It is same but it can be little bit difference by Make of chiller.
Very nice
Thanks
Well explain sir
30XA carrier chiller use krte hai
134a refrigerants hai
Discharge pressure 200 psi m agr nhi jta it's means compressor load p nhi hai to fir 150 psi m ap bol rhe cut of hoga
thanks
Sir ap ney aik bat to ki ni expansion valve kiss liye use hota ha
Sir which approach is important condensor or evaporater?
Evaporator to save compressor.
Very good explained sir
How to set this
What is motor kw /TR ratio for R134a. What is interstage pressure in COMPRESSOR? what is efficiency /cop of chiller. What is flow rate chilled water, brine as per thumb rule per TR of plant?
Dear It depends on many factor and types of compressor but approx 1.5 to 1.7 TR for 1 KW in Centralize AC.
Sir interview krado apni company me
If superheat up to 25
How I solve this problem?
Nice sir electrical technician or industrial electricain ma different kya hai or kaam ke bare kuch jankari chiye
Koi khaas fark ni hota bus jis industry me kaam karte han usi type ki machinery ki knowledge hoti ha bus itna fark ha. Mostly electrical work same hota h.
@@BuildingSanchalan ups or dg vedio upload kiye sir
Cooling tower & chilled water Water me kaya hai sir please tell
Aap kya puchhna chahte ho?
++
Sir cooling tower me wet bulb temp aour chiller condenser water entering temp ka kya mtlb hai jaise cond entering temp 29c hai to wet blub ka temp kitna hona chahiye
Wet bulb temperature environment temp ha jo wet thermameter ki sahyata se check kiya jaata h, yadi jyada janan chahte ho to cooling tower paylist me video dekh lo.
Sir for what capacity chillers these settings ?
All centralised chiller, it may be little bit differ.
R134a according chiller plant me suction pressure n discharge pressure kitna hona chaheye plz betaine
th-cam.com/video/WB-LsP2KB7I/w-d-xo.html watch it.
In line me lga rhta ya out line m sir
what?
Hi
cfm duct dising k video banaye kindly
Asif thoda time lagega abhi kaafi demand wali video pending han. parantu jarur banaunga
Sir condenses ka water pressor kitna hona chahiye
Condesor water pressure cooling tower distance ke anusar aur machine ke anusaar hota ha ..th-cam.com/video/Aj4tKJDPgQ0/w-d-xo.htmlsi=ccl-AmRN0Fz6VbpM watch it
Sir link diya kro low pressure ka video ka plz
C°me keya rakhege
Chiller safety Fahrenheit me hi hoti h
Sar AC plant mein Kirloskar compressor hai aur ammonia gas hai iska video kar bataiye
Friend ab to amonia gas bann ho gayi ha aur aage nahi aati hvac plant me. Kya yeh jyada puranaa ha?
Sir Condenser inlet and outlet temp. How much have any video
yeh fix ni hota, Mausam ke anusaar change hota ha.
Nice Explanation sir...
Comprsn
Good explained
super heat me sir dout hai ...pls fir se samajana .......super heat = refrigerant suction temp - evaporator saturation temp ............matlab suction temp .and saturation temp difarance ..galat hai ya sahi o batana
Superheat is measured as the difference between the actual temperature of the refrigerant vapor and the saturation temperature of the refrigerant at that same point. Your comment is right.
Campresser sefti
All electrical safety is used for compresson safety.
Sir mere plant me Trane chillers h or un ka chilled water pressure 4 kg rakha jata h 3 kj pr plant trip ho jata h or aap bta rahe h ki 1 se 2 kg rakhna h aisa q ???
Bilkul sahi kon sa refrigerant use kiya h
@@BuildingSanchalan r123
Sir, ye Kaun sa chiller Ka parameters hai
York
My ice plant compressor drip after 15 min
Chiller oil ka name ?
For screw and rotary = Compressor oil 68 ( synthatic or Mineral oil).
For Others = Oil 122 & 220
Sir aap coching chahiye kya proses hai
Sorry dear aap channel se seekh sakte h yadi koi question h to puchh lena
Sir chiller trip honeka baad kaise radi karta sir bola sir please 🥺
First check safety kon si active ha. yadi normal ha aur sabhi parameter sahi ha tab safety reset karne ke baad start kar sakte ha. Parantu pahle alarm check karenge aur trip kyon hua use door karen.
Explain thik hai but yar ye yad nhi rhti
Thank you sir ji amazing explenation
Most welcome
High pressure 280 psi not 150 psi
Dear May be you are right in any brand but if have any reference then share i will correct myself. Thanks for your comment.
Super video
thanks
Wonderfull
Chillar kon kon gas rha h
बहुत सारी कैसे यूज़ की जाती है लेकिन आजकल r134a यूज़ की जा रही है
Sir apka number konsa hai
Sir jaise aap bole cond ki super heat 12-20 'F agar 'c mein nikal tehw toa -11- -6'c. Agr minus mein jata h toa ye ice banadega
Pls explain
Superheat temperature ni ha vah do temperature ka difference ha
Totally wrong information
Sahi batayen sir, Kya ha? khali kahne se ni chalta.
Great sir
Thanks