The symptoms of a bad injection pump

แชร์
ฝัง
  • เผยแพร่เมื่อ 5 ม.ค. 2025

ความคิดเห็น • 16

  • @elcolibri1971
    @elcolibri1971 6 หลายเดือนก่อน +1

    Thanks sir 🔧,I had already checked that filter and I think the problem is with the lift pump, a few months ago the tank was contaminated, the injection pump and injectors were serviced but nothing has been done to the lift pump

  • @christopherfadera763
    @christopherfadera763 8 หลายเดือนก่อน +1

    Big help for us. Thank you sir 🙏

  • @antoniogonzalezmedel
    @antoniogonzalezmedel 7 หลายเดือนก่อน

    My FGWilson trip in the First start by overspeed... In the second start no problem... I gona Check my filter of pump. Thanks Mr.

    • @northjayhoon9789
      @northjayhoon9789  7 หลายเดือนก่อน +1

      Greetings
      First start overspeed means there is a problem with the fuel line
      The fuel from filter housing returns back to the fuel tank after some hours , while the generator is standby
      In this situation before you start the engine please run the prime pump for two minutes and start the engine , if the engine did not overspeed which mean the fuel line gets empty when it is standby for two or three hours
      Note: if your generator doesn't have an electric fuel prime pump
      Pump it manually.

  • @electricalrme2267
    @electricalrme2267 6 หลายเดือนก่อน

    Thanks Sir. Please upload more troubleshooting videos.

  • @Automation_workshop
    @Automation_workshop 4 หลายเดือนก่อน

    Hi dear,
    We have a Cummins generator, it trips on overspeed alarm, what could be the cause? Fuel SOV relay is okay, starter is okay, we could not figure out where is the problem.

    • @northjayhoon9789
      @northjayhoon9789  4 หลายเดือนก่อน

      Greetings !
      Could you please give further information ?
      Is this Genset overspeed at first start, or any time when you crank it overspeed?

    • @Automation_workshop
      @Automation_workshop 4 หลายเดือนก่อน

      @@northjayhoon9789 every time when we start the gen set trip on over speed, over speed setpoint is 1650, speed probe is healthy, engine trips during cranking

    • @northjayhoon9789
      @northjayhoon9789  4 หลายเดือนก่อน +1

      Thank you for your info,
      Your Genset RPM should be 1500,
      Your generator voltage 230 volts and 50Hz at 1500 RPM
      If you don't have any issue with fuel line and injection pump, your engine RPM should remain the same rpm ,even after loading
      In this case adjust the engine RPM at 1550 and then load the genset see if the engine RPM remain at 1500 if so! your problem solved.

  • @abdualkadershuga1163
    @abdualkadershuga1163 6 หลายเดือนก่อน

    Hello my dear friend, I have a problem with a Caterpillar C18 generator, 500 kilowatts. After the generator is started without load, there is a problem with the speed and voltage stabilizing together, with a humming sound occurring in the generator. It is unstable. Please help me. Many thanks and respect to you.

    • @abdualkadershuga1163
      @abdualkadershuga1163 6 หลายเดือนก่อน

      Please, can you give me your WhatsApp number so I can send you a video clip of this problem

    • @northjayhoon9789
      @northjayhoon9789  6 หลายเดือนก่อน

      Greetings
      Thank you for your enquiry!
      Can you tell me about RPM and the voltage in your country?
      If the voltage is 110 v 60Hz the RPM should be 1800 for 220 v 50Hz the RPM should be 1500.
      First make sure stabilize your engine speed , either there is problem with your fuel line or the injectors are bad .
      01 Check the fuel line and the pump pressure .
      02 inspect the injectors .
      If they are all ok
      Do a compression test make sure you don't have any problem with your engine after inspection when you got all ok the engine speed stabilized , check the voltage if still the voltage fluctuating please check the AVR.

    • @abdualkadershuga1163
      @abdualkadershuga1163 5 หลายเดือนก่อน

      the RPM 50/52/48 And Voltage 400/420/389/380

    • @abdualkadershuga1163
      @abdualkadershuga1163 5 หลายเดือนก่อน

      Speed ​​and voltage are unstable