- 57
- 278 354
DIY & Fix it
Uganda
เข้าร่วมเมื่อ 12 มิ.ย. 2016
I started this channel as a way of helping out my fellow DIYers. I enjoy helping people fix their cars, generators, air-conditions, washing machines and other electronics home appliances.
If you interested to learn multiple things subscribe the channel and keep learning.
If you interested to learn multiple things subscribe the channel and keep learning.
How to replace AC indoor unit's blower motor bearings on LG WITH DUAL INVERTER COMPRESSOR
The blower motor in a forced-air heating and cooling system powers the fan that distributes air throughout your home and draws it back into the HVAC for reheating or cooling. The types of HVAC systems that use blower motors include furnaces, air conditioners, heat pumps and ductless mini-splits.
th-cam.com/video/9jCTgVvWVgo/w-d-xo.htmlsi=Py0bice_wT02KwD7
th-cam.com/video/9jCTgVvWVgo/w-d-xo.htmlsi=Py0bice_wT02KwD7
มุมมอง: 868
วีดีโอ
Magnetic Pickup Speed Sensor Test on Perkins Diesel Generator.
มุมมอง 1.5K2 หลายเดือนก่อน
A magnetic pickup is an AC generator. It is normally installed into the flywheel housing of an internal combustion engine, so that the starter ring gear acts upon it to generate a voltage pulse each time a gear tooth passes the end of the sensor. th-cam.com/video/4O-50ywg39c/w-d-xo.htmlsi=AdRBrYQmoWsvJ8mh th-cam.com/video/8U6Yu3nxvuE/w-d-xo.htmlsi=lngVqIz7F_Bj4Flo
How to replace AC indoor unit blower's motor on LG Dual Inverter Model
มุมมอง 1.3K2 หลายเดือนก่อน
A failing blower motor may emit unusual sounds. This may sound like screeching or squealing if it has bad bearings. You may hear a rattle or a banging sound if something inside the motor has broken or come loose.
Diagnosting Air conditioner's indoor units noise #lg
มุมมอง 1003 หลายเดือนก่อน
If the blower fan in your air handler (indoor unit) is out of balance, it can cause a pulsating noise as it rotates. This is often due to a buildup of dirt and debris on the fan blades or loose parts, which can throw off the balance and create vibrations down your ductwork. sometimes the motor itself making noise it is because lack of lubrication and some motors designed you can not disassemble...
Simple way to find out why engine oil seal goes bad so fast #perkins
มุมมอง 1513 หลายเดือนก่อน
If the engine breather get clogge In this particular perkins engine the oil will leak due to high pressure in the crankcase. Eventually, the oil can contaminate and degrade engine seals if you do not make sure to get regular oil changes for your engine. Finally, engine overheating can also cause problems that lead to a leak. If a cylinder head or other component warps due to overheating, oil ca...
Top Load Washing Machine dL Erorr Code. #lg
มุมมอง 654 หลายเดือนก่อน
Error DL means that your door lock has failed. Whether you hear the lock trying to latch or not, the latch will need to be replaced to fix this problem. It's actually a fairly easy part to replace.
Troubleshooting : Emergency stop button #perkins
มุมมอง 4675 หลายเดือนก่อน
The button safely shuts down all power, including uninterruptable power supplies, batteries and generators from a central location. EPO buttons can be found in places such as manufacturing plants, telecommunications facilities and IT data centers.
How To Troubleshoot Fuel In Oil Contamination . Diesel engine...
มุมมอง 3535 หลายเดือนก่อน
Fuel dilution can decrease oil viscosity and lubricity even at very low levels, increasing both bearing wear and the potential for bearing failure.
How to install an oil seal correctly.
มุมมอง 2.1K6 หลายเดือนก่อน
Oil seal: how to install it correctly 1: Preparing the oil seal installation. 2: Remove the old oil seal. 3: Select the correct oil seal size. 4: Check the materials and surfaces. 5: Clean the surfaces. 6: Use the right assembly tools. 7: Assembling the oil seal.
How to fix a leaking mini split AC, With simple tools in your home depot.
มุมมอง 2636 หลายเดือนก่อน
One of the most common causes of leakage is clogged drainage. The culprit can be dirt, dust, and fungus that block the water to flow. The water will try to find the other way out, causing the AC to leak. If you let this problem sit for too long, this may cause a breathing problem.
The symptoms of a bad injection pump #perkins
มุมมอง 9557 หลายเดือนก่อน
Here are the symptoms to look out for when you suspect there are issues with your engine's injection pump: -Hard starting. -Reduced engine power. -Increased fuel consumption. -Visible increase in exhaust smoke. -Misfiring.
5 Reasons why your air-conditioner is not cooling well, #airconditioning
มุมมอง 5059 หลายเดือนก่อน
There are a number of reasons why your air conditioner might be running but not cooling. It could be an issue with the thermostat, the compressor, or the evaporator coils. Or, it could simply be clogged with dust and debris, which is preventing it from working properly.
Engine Oil Pressure Sensor Wiring 1103/1104 Series #perkinsfamily
มุมมอง 3.6K11 หลายเดือนก่อน
An oil pressure sensor is a simple device that sends signal to the Genset controller This is a very simple device made up of a spring-loaded switch and a diaphragm. The diaphragm receives oil and is designed to stay open at a set pressure level.
A Bad Oil Pressure Sensor's Symptom #perkinsfamily
มุมมอง 1.5Kปีที่แล้ว
A Bad Oil Pressure Sensor's Symptom #perkinsfamily
Understanding SPN & FMI Fault Codes. #spn #fmi
มุมมอง 5Kปีที่แล้ว
Understanding SPN & FMI Fault Codes. #spn #fmi
Engine Under Speed Shutdown SPN 190 FMI 1 Diagnoses.
มุมมอง 6Kปีที่แล้ว
Engine Under Speed Shutdown SPN 190 FMI 1 Diagnoses.
PowerWizard Control Module Description #perkins
มุมมอง 684ปีที่แล้ว
PowerWizard Control Module Description #perkins
Engine failure to start due to a bad Relay #perkins
มุมมอง 13Kปีที่แล้ว
Engine failure to start due to a bad Relay #perkins
Unexpected engine shut down symptoms. #generator #1millionsubscribers
มุมมอง 12Kปีที่แล้ว
Unexpected engine shut down symptoms. #generator #1millionsubscribers
CH 05 Error LG Dual Inverter Air-condition #ac #error #codes
มุมมอง 56Kปีที่แล้ว
CH 05 Error LG Dual Inverter Air-condition #ac #error #codes
Engine Valve Grinding/Lapping #youtubeshorts
มุมมอง 3Kปีที่แล้ว
Engine Valve Grinding/Lapping #youtubeshorts
How to Adjust Generator's Voltage ? #AVR #perkins
มุมมอง 6Kปีที่แล้ว
How to Adjust Generator's Voltage ? #AVR #perkins
What Cause Engine Under Speed Shutdown on Generator #perkins
มุมมอง 6Kปีที่แล้ว
What Cause Engine Under Speed Shutdown on Generator #perkins
How to Clean Properly an Air-condition's Evaporator. #lg #ac #maintenance
มุมมอง 1Kปีที่แล้ว
How to Clean Properly an Air-condition's Evaporator. #lg #ac #maintenance
Crankshaft Position Sensor Test #toyota #crankshaft #positions #sensor
มุมมอง 6Kปีที่แล้ว
Crankshaft Position Sensor Test #toyota #crankshaft #positions #sensor
LG Top Load Washing Machine Error Codes & Maintenance.. #lg #topload #washing #machine
มุมมอง 4.5Kปีที่แล้ว
LG Top Load Washing Machine Error Codes & Maintenance.. #lg #topload #washing #machine
Was it necessary to remove the whole fuel injector pump? I think the fuel solenoid was enough
You probably didn't see the video till the end That Injection pump you were watching was not for this generator it was only for demonstration for well understanding the circuits.
IAM interested to find troubleshooting
𝚋𝚛𝚘 𝚑𝚎𝚕𝚙 𝚖𝚎 𝚏𝚒𝚗𝚍 𝚌𝚛𝚊𝚗𝚔𝚜𝚑𝚊𝚏𝚝 𝚜𝚎𝚗𝚜𝚘𝚛 𝚏𝚘𝚛 𝚃𝚘𝚢𝚘𝚝𝚊 𝚅𝚒𝚜𝚝𝚊 1997 𝚖𝚘𝚍𝚎𝚕
Thanks for the idea🌟
good batteries i open injector lines and prime. saves batts
❤
Good
So helpful, was able to get my AC working again. Will have to change the wire entirely.
This malfunctioning in our Dg set, hope the suggestions given must work for us. Thanks for sharing.
Again thanks bro
Yes another idea thanks again broooo........
Thanks bro gor the info keep going brother
❤❤❤❤
Very good example and good simple understanding 🙏👍
I'm glad you found it helpful!
Which one is the auto button on the display
Here you are click on this link : th-cam.com/video/s7L_hLY1P9E/w-d-xo.htmlsi=__5p78rfz2O5w1SM
Been looking for this solution everywhere. Thanks for providing!
Glad to help
hindi
Good evening my volvo D9 generator say engine can bus fault emergency stop hardware any ideas how to fix it please
CAN Controller for CAN Bus may be faulty Check the wiring Check the Controller unit
@northjayhoon9789 will do thanks a lot 👍🏻👍🏻
th-cam.com/video/7KCAP_N2o2w/w-d-xo.htmlsi=RrNmNmPeBdhnqf3N
Good work sir, but how to troubleshoot a generator that stops after running for some munities after stare
If your Genset controller is functioning well, it should tells you why your Generator's engine stops otherwise there are many reasons to stop the engine such as a faulty relay , a faulty injection pump solenoid, engine high temperature and 12 volt power interruption in controll modules, all the sensors feeds from Genset controller any power interruption causes engine shutdown.
Thanks
You're welcome!
Have you had any issues with the wave washer making noise? I was concerned the soft rubber sidewall sealed bearings wouldn't hold up over time next to metal wave washer pressed against it.
I never had any issues with wave washer but I always check to make sure the wave washer overlap the bearing cup. If you select the right bearing it never happens.
You make too big a deal of just screw it into a stop by hand back it out one turn
Thanks for your comment! You can do that, I can do that but for a trainee mechanic who still need experience I think it is ok take more time do a measurement to make sure everything goes will.
This model same generator starting very well and after 1 minute automatically shutdown.
Please check the event's log and tell me what ever the genset controller has been detected.
Very informative! What happens with the coolant if you remove the indoor unit for cleaning?
th-cam.com/video/QcyhvYNp-Lg/w-d-xo.htmlsi=WFoNrBqT964g1HWi
Dear, Sir pls make another playlist where u Only upload generator trouble shooting & it remedy.
th-cam.com/play/PL9emt8gEX58TzK4hH1VPTD9oyFoMaumEr.html&si=WSRDG6wCnrdJPOHl
Tnx
Check that magnet for metal chips which causes a malfunction. Also air gap between magnet sensor and rotating teeth.
Great advice! It's essential to inspect for those factors to ensure accurate readings.
i need a mull timitter🤣🤭
Hopefully you're gonna get it.
Speed sensors fail by shorting through or becoming an open circuit. Check them with an ohm meter. They will have no resistance or infinite resistance if bad. I've never seen one be out of calibration but if that was suspected, they should be checked against a strobe tach. Shoving paper clips into the harness connectors will provide a nice tunnel for water to enter and corrosion to form inside the harness.
Great point, thanks for sharing your experience!
th-cam.com/video/-mFO2LvLQV0/w-d-xo.htmlsi=rWBIPoCYtqnI5xo3
th-cam.com/video/-mFO2LvLQV0/w-d-xo.htmlsi=rWBIPoCYtqnI5xo3
th-cam.com/video/3KykFyM69xQ/w-d-xo.htmlsi=58_RnCxahmFxX5H1
th-cam.com/video/8U6Yu3nxvuE/w-d-xo.htmlsi=lngVqIz7F_Bj4Flo
th-cam.com/video/4O-50ywg39c/w-d-xo.htmlsi=AdRBrYQmoWsvJ8mh
th-cam.com/video/7KCAP_N2o2w/w-d-xo.htmlsi=CCI63mzsDgPNLISH
th-cam.com/video/9jCTgVvWVgo/w-d-xo.htmlsi=ivzByS6r9NC7OGOA
th-cam.com/video/3KykFyM69xQ/w-d-xo.htmlsi=wMlbyiCYuB504mis
th-cam.com/video/-mFO2LvLQV0/w-d-xo.htmlsi=ZMEWR1ehcxxSXQZO
th-cam.com/video/-mFO2LvLQV0/w-d-xo.htmlsi=ZMEWR1ehcxxSXQZO
I have the same issue i have checked the wire and is ok please what else can i do to resolve this issue
Check the pcb board at the outdoor you may have a malfunction component also check the main board at the indoor unit Note at the outdoor unit the pcb board has a fuse check make sure it is not blown.
I like to know more about it again
th-cam.com/video/-mFO2LvLQV0/w-d-xo.htmlsi=J42k6tLruueFFwNw
this is good stuff keep making this educational videos thank you!
Thanks for watching and I’m glad you find it helpful!
please keep making similar videos you are the best!
I'm glad you're enjoying them!
Love this tutorial you teach very briefly ❤
Glad it was helpful!
Greetings engineer I have this issue with one of my generator i am doing maintenance,thanks very much for the procedure,i will go and try it there,but was show me speed sensor disconnected
Dear Sir If it is showing the sensor has disconnected Please check the sensors circuit it might corroded or the sensor is bad you can check the resistance of the sensor by multimeter Crank the engine and check the sensors resistance. You can do this if you bypass the starter motors solenoid in order to be able to crank If you want to know how to test this sensor let me know I will upload a related video.
Thank you. This is well done and clearly shows the process. Good job!
Glad it was helpful!
th-cam.com/video/NR0FgvvIzec/w-d-xo.htmlsi=nFBoHZRh7Aw-k5gD
th-cam.com/video/7KCAP_N2o2w/w-d-xo.htmlsi=hjs16-_iix9kUo3a
th-cam.com/video/GseWzLig-k0/w-d-xo.htmlsi=YRZUGLgaS2W8VBNR