Lighting Sensor Wiring with Override Facility

แชร์
ฝัง
  • เผยแพร่เมื่อ 27 ก.พ. 2020
  • Wiring for a PIR, microwave or photocell with an override facility, so that the lights can be off, automatically controlled or permanently on. Two different methods, using two switches or a single centre-off switch.
    These methods result in a single cable at the light, and a single cable at the sensor, for easier installation with fittings that have very little space inside.
    ► Support this channel:
    Patreon: / jwflame
    PayPal Donations: xo4.uk/?PPP
    ► Social Media:
    Twitter: / jwflame
    Facebook: / jwflame
    Instagram: / jwflame
    ► Contact info, sending stuff in: etc.:
    xo4.uk/?YTT
    ► Website - More on this video and many other subjects
    Website: www.flameport.com
    Page for this video: xo4.uk/?Sen
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 198

  • @robwilkie1
    @robwilkie1 4 ปีที่แล้ว +1

    Moved into a new house recently that has photocell lights with an override and I’ve been puzzling how these work so great timing John. Ours have a fused spur as the main on/off and then a separate switch for the override and the photocells are built into the lights but I can at least now understand how they can work. Great video thanks.

  • @PurpleTT99
    @PurpleTT99 4 ปีที่แล้ว +7

    Well that's had an odd effect. I now feel totally inspired to review and upgrade the external lighting chez nous. Been thinking about a series of lights along the drive all switched by one PIR but wasn't entirely sure how to wire it, was planning to google it! This was excellent, thanks JW.

  • @Wilkkid1
    @Wilkkid1 4 ปีที่แล้ว +1

    Great vid John last job I was on we ran a feed to a key switch then a 3 core to the pir then connected the switched feed for the lighting circuit in the pir

  • @dw1hkdavidtkwong
    @dw1hkdavidtkwong 3 ปีที่แล้ว

    I am no electrician, but your teaching is clear and very understandable. Thank you for sharing..

  • @sunshine7453
    @sunshine7453 4 ปีที่แล้ว +4

    Great presentation! I have learned a lot from you in just a few minutes. Thank you!

  • @chrisholmes8250
    @chrisholmes8250 2 ปีที่แล้ว +2

    Absolutely superb explanation. You have saved me a massive headache (and probably massive electrocution). Just brilliant 👍🏻

  • @thomasbyles3075
    @thomasbyles3075 4 ปีที่แล้ว +1

    Very helpful. Being an apprentice I’m really struggling with taking the feed to the switch with one ways all the way to intermediate. I know you’ve done some videos on this but if you’re looking for ideas for more I’d love to get more guidance on this. Thanks for the videos JW

  • @grantrennie
    @grantrennie 4 ปีที่แล้ว +3

    Thanks for the great video John 👍

  • @millomweb
    @millomweb 4 ปีที่แล้ว +8

    13:04 - connection to light, I'd have connected to the bottom terminal of switch 2 and the live out of the top of switch 1 I'd have connected to terminal 1 on the top of switch 2. For the purposes of clarity of drawing. It'd also have the electrical safety benefit of not making SL live on the PIR when the light was permanently on.
    I take it you're now going to connect the live out of sw 1 to the bottom terminal of sw 2.

  • @davidbalfour798
    @davidbalfour798 3 ปีที่แล้ว

    Great content, just fitted PIR with gridswitch, worked first time.

  • @alanfowler1187
    @alanfowler1187 4 ปีที่แล้ว

    Thanks for the presentation, It explains something that was puzzling me. My outside lights were wired with 3 core & earth, and the wiring diagram in the lid showed no external connection to the light connection. In fact there the black core was connected. When the switch was activated the lamp lit continually, and in the off position it was controlled by the PIR. Your presentation made clear what was intended. However they had cheapened the installation by using no second switch. The line connection was hard wired without a switch!!
    Now I see how it is supposed to work, I can live with it, but it is not Ideal.

  • @adrian-mu3jr
    @adrian-mu3jr 3 ปีที่แล้ว

    Excellent video and solution for PIR lights. Thanks

  • @noskills9577
    @noskills9577 4 ปีที่แล้ว

    No doubt I'll be referring back to this, thanks 👍

  • @gyasikrasineb4808
    @gyasikrasineb4808 4 ปีที่แล้ว +15

    A massive thumbs up John a fantastic video well explained, no possibility of making any mistakes in connections brilliantly narrated and a treasure source of knowledge. THANKS.

    • @millomweb
      @millomweb 4 ปีที่แล้ว

      This is one way of doing it. Other options are available !

  • @millomweb
    @millomweb 4 ปีที่แล้ว

    My preference for switch labelling is off/on and auto/man (ual).
    I've done this switching arrangement on a number of situations, whether lighting, heating or compressing.

  • @johndoe2769
    @johndoe2769 3 ปีที่แล้ว +1

    Great Stuff again John, Thanks for the video and sharing your knowledge : )

  • @snail5967
    @snail5967 4 ปีที่แล้ว

    Interesting solution - I have just fitted a pir sensor in a cupboard - 1 x 2 way switch only so supply goes to switch, then to sensor and on to light using just twin and earth cable. In this case, the client doesn’t really need the option of the light being switched on permanently in case she forgets to turn it off after closing the door! I can see a great use for this circuit in a garden with a pir where you may want to keep the floodlights on during bbq season etc., - so thumbs up from me JW👍

    • @millomweb
      @millomweb 4 ปีที่แล้ว

      Block of flats hallway lighting was on timeswitch. I had it converted to PIR with two override switches as per John's first circuit.
      Fitted our understairs cupboard with PIR, permanently on. Worked fine for years then failed to turn off. Now plan to fit a door activated switch to do the job - meaning light would remain on while door open - which PIR turned off ! As doorbell transformer is in there, Plan to light the cupboard with LEDs off that via door switch. One day, I might get round to it !

  • @michaelbirchall2247
    @michaelbirchall2247 3 ปีที่แล้ว

    You make everything make sense. Thank you.

  • @robinnorman795
    @robinnorman795 ปีที่แล้ว

    Cheers John been ignoring an issue for months thanks for the help worked out first time too

  • @nigelwood9385
    @nigelwood9385 3 ปีที่แล้ว

    Thanks great explanation. was thinking of using a standard 3 pin plug for the supply to plug into a wall or garage socket so only needing a single 1 gang 2 way switch same as your second example but the on/off at the socket. This may sound strange but I'm retro fitting a pir to existing circuit just replacing the switch so will connect the neutrals inside the switch using wago 3 way connector

  • @redsolar7
    @redsolar7 ปีที่แล้ว

    love the way you simply methods 👍🏾

  • @user-qx4yy2wq1z
    @user-qx4yy2wq1z 5 หลายเดือนก่อน

    Best explanation I've found. Thank you

  • @pcg1276
    @pcg1276 ปีที่แล้ว +1

    Hello John. I enjoyed watching your video on how to override a pir sensor using a two gang and centre off switch.
    I Set up a practice board and found the same result can be achieved if you use a one gang one way switch and a 3 core cable from the pir to the switch.Take the supply feed to the switch connect the live feed to common and the pir switch line to L1 or L2 and join the neutrals using a connector block or wago.

    • @0044512
      @0044512 3 หลายเดือนก่อน

      That’s the way our outside light was wired, PIR and on/off switch to override with one-gang.

    • @JayG2K
      @JayG2K 3 หลายเดือนก่อน

      how can it be a one way switch if you have L1 and L2. that would be a two way switch

    • @pcg1276
      @pcg1276 3 หลายเดือนก่อน

      @@JayG2K connect permanent live from the board and pir to common then add the switch line to L1. The neutrals go into a connector block as does the earth.

  • @Kairosproperty
    @Kairosproperty 8 หลายเดือนก่อน

    Hi John,
    Totally brilliant, have used it and it works a treat.
    Regards Kairos

  • @kennybrown9985
    @kennybrown9985 3 ปีที่แล้ว

    Hi John, brilliant video/explanation. Would it be possible to add a timer switch to your wiring diagram so that when switched on permanently the timer could control the on period. If yes could you provide guidance on how this could be done. Many thanks.
    Kind regards,
    Kenny.

  • @chrisdavies1814
    @chrisdavies1814 2 ปีที่แล้ว

    Hi john great video very informative, how do you go about R1+R2 testing and insulation resistance testing with a pir in circuit ? thanks

  • @tauraigatsi7664
    @tauraigatsi7664 9 หลายเดือนก่อน

    Brilliant and quite comprehensive explanation.
    Question : how can we connect such a sensor light connected to an extraction fan?

  • @djchrisparr
    @djchrisparr 3 ปีที่แล้ว

    Brilliant vid, cheers!

  • @explorer47422
    @explorer47422 4 ปีที่แล้ว

    I was thinking of having a PIR (or micro) in my bathroom, and would want an override switch on the outside to have it permanently on or on auto. However I'd also wanted a switch, on a separate gang (maybe above the door with the fused switch) that would override it to be permanently off. The trick I guess is not have any single cables going somewhere but a mixture of 3 and 4 core cables!

  • @AdamSpooner191
    @AdamSpooner191 3 ปีที่แล้ว

    Hi John, Thanks for the video, really like the idea of the centre off switch.
    Can this arrangement work if I wire in series i.e. have a 3core and E from the centre off switch to the PIR, then a twin and E from the PIR to the light? I can then connect the PIR SL straight to the light? I'll be using wiska boxes for wiring connections throughout. Any help would be appreciated.

  • @propertyomgtv254
    @propertyomgtv254 3 ปีที่แล้ว

    You're just awesome! Precious content
    Thank you

  • @thomasread1612
    @thomasread1612 2 ปีที่แล้ว

    A nice explanation, maybe best to have flat faced connection box (wiska) to mount your PIR on. All your connections are up in the eves and not show excessive cables coming down (surface mounting) at switch which is all the customer will see. Also multiple PIR's need to link their switch Line to multiple lights.

  • @chriswright6558
    @chriswright6558 3 ปีที่แล้ว

    Hi thanks for the video you explain everything nice and clearly I am thinking of installing outside lights with a double switch and PIR like in the video but I don’t require the all off switch just PIR override as with the 1st switch I want to control 1 light by the back door and have flood lights controlled by PIR with override for BBQ’S ect
    Would it work if I just connected the common from the switch to the PIR L or will I need 3 switches as they will be outside switches

  • @millomweb
    @millomweb 4 ปีที่แล้ว +1

    Version 2 (21:00) I'd be looking for a switch with off in the upper position, not centre - and centre being 'auto' - just to maintain the loose standard of up for off.

  • @ianfielding4123
    @ianfielding4123 3 ปีที่แล้ว

    Hi John great videos. Is it possible just to have a switch that turns the pir and light off when not needed? Thanks

  • @RobIbb
    @RobIbb 3 ปีที่แล้ว

    Great video, but one question. How would this change if it was at the end of an intermediate light circuit?

  • @billglass5160
    @billglass5160 3 ปีที่แล้ว +4

    Another suggestion if you're not sure if the PIR is using a relay or electronic switch then: 1. Always keep the PIR powered up to the Power Line and Neutral. 2. Connect PIR output SL to the 3-way switch L1. 3. Connect Power Line L to 3-way switch L2. 4. Connect light line L to 3-way switch common C. 5. Connect light Neutral N to Power Line Neutral N.

    • @NevDunn
      @NevDunn 10 หลายเดือนก่อน

      how do I wire to an existing light. Can it be wired direct to the light fitting?

    • @elliotgray9666
      @elliotgray9666 หลายเดือนก่อน

      I did it this way, too.

  • @tomtom786
    @tomtom786 3 ปีที่แล้ว

    Hi JW, thanks , could you explain connecting 2 motion sensor (PIR) lights to a switch, both as masters please.

  • @1alph1
    @1alph1 3 ปีที่แล้ว

    Fantastic!!! Keep up the great videos

  • @melvis2017
    @melvis2017 3 ปีที่แล้ว

    great job thx good experience and explanation

  • @barryhall5659
    @barryhall5659 3 ปีที่แล้ว

    Hi, if you didn't need nned the override facility on a PIR, would you simply be able to use a 1 Gang 2 Way Switch, using the L1, L2 and COM connections as per your video at around 14:30 mins? Thank you!

  • @rachelelinpearce4135
    @rachelelinpearce4135 หลายเดือนก่อน

    Really simple cheers for that

  • @SPARKY400T
    @SPARKY400T 4 ปีที่แล้ว +1

    Another great video John Thanks! Can we have one on Power Factor please

  • @segovia102
    @segovia102 3 ปีที่แล้ว

    We have outdoor lights connected to one switch such that in one position the PIR works but in the other position the light is permanently on. Works great for us. Is this bad practice or dangerous? I'd like to do something similar in a hallway but do not want to use two switches.
    The PIR is using 0.5 watts if you don't have an 'everything off' switch, but beyond that is it terrible?

  • @jacknguyen1869
    @jacknguyen1869 3 ปีที่แล้ว

    Hi John... I've learnt so much from you. Can you please please do video of emergency lighting in single and T&E. Thank you.

  • @chrispascall2616
    @chrispascall2616 3 ปีที่แล้ว

    Great video but the problem I find is that most flood lights now include a sensor but they are now all sealed and you can't get access to bypass them anymore. This is somewhat frustrating as it means buying separate units, separate mounts plus a more complex wiring. The old one you could disconnect and rewire!

  • @AB-oc5lj
    @AB-oc5lj 3 ปีที่แล้ว

    Another gem from you John, thank you. Keep 'em coming!

  • @thephilpott2194
    @thephilpott2194 4 ปีที่แล้ว

    Not watched the vid yet but I did something similar using two switches. I used Triple & Earth for part of the wiring.

  • @markmitchell8593
    @markmitchell8593 2 ปีที่แล้ว

    Really useful video, thank you. I wonder if i can use a timeclock instead of the override switch, such that I can bring the light on under timeclock control, and then when the Timeclock switches off, the light remains under PIR control, so effectively using the timeclock as an override.

    • @jwflame
      @jwflame  2 ปีที่แล้ว

      Yes, a timeclock is just a switch operated by a clock - the principles of wiring it are exactly the same.

  • @johnromberg
    @johnromberg 8 หลายเดือนก่อน

    I think I'll do it by going sw1 + sensor in series with sw2 in parallel to both. Instead of sw1 + sensor in series and just the sw2 and sensor in parallel, which this seems to be. It's a small difference both in wiring (just tie the switch inputs together instead of sw1 out to sw2 in) and operation, but it does mean that sw1 is just for enabling/disabling the sensor and sw2 operates the load as normal. Nice and separate functions for the switches, no need to have both on to definitely have the light on. Although it will be. It's just a single difference in the truth table, when sw1 is off and sw2 is on the load is on, instead of off.

  • @miro_s
    @miro_s ปีที่แล้ว

    Thank you

  • @glenlucas4332
    @glenlucas4332 3 ปีที่แล้ว

    You have such a cool voice ...I'm envious!!

  • @ifyougetstucklookitup237
    @ifyougetstucklookitup237 2 ปีที่แล้ว

    Thank you.

  • @christopherhall550
    @christopherhall550 2 ปีที่แล้ว

    I have outside lights with a sensor built in and also a separate PIR by the garage. this has a three wire feed. I put two new light bulbs in and thought that I would clean the separate sensor but I must have damaged it. Can I replace it with an ordinary PIR or a special one? What would the wiring configuration be? Any help would be great.

  • @ghulammuradi6651
    @ghulammuradi6651 2 ปีที่แล้ว

    Hi, is this set up have no constant power to the PIR ? As in one of your other videos you suggested that PIR should have a live wire connection as would more reliable? Or maybe I seen the video somewhere else suggested that PIR needs a constant live connected!!

  • @pegnaz1994
    @pegnaz1994 2 ปีที่แล้ว

    Question: I would like to program my chicken coop heat lights to come on at dark and go off when when it is 50゚or more outside which is which is well after it becomes light.
    Wondering if you have an idea on how to wire or program this?
    Combo heat/light sensor?

  • @deanaston4538
    @deanaston4538 2 ปีที่แล้ว

    Would you not have the pir permanently live and add the switch into it as a on off override or do it this way.

  • @millomweb
    @millomweb 4 ปีที่แล้ว

    Global lighting-wise, this video's the other way around ! Starts with the globe unlit, ends with it lit !

    • @hayderuk7970
      @hayderuk7970 3 ปีที่แล้ว

      Thank you for the information John

  • @johnworkinger2203
    @johnworkinger2203 2 หลายเดือนก่อน

    outstanding.

  • @martinrenfrew2111
    @martinrenfrew2111 ปีที่แล้ว

    Great video. However I connected my outside light photocell as described for 3 position switch. Everything fine except for when in the override on position. Lights are manually on but I can here photocell switching on and off constantly. This is due to removing live input to photocell but having live connection to photocell switched output. I could replace photocell with relay output type but manufacturers detail don’t appear to give this info. In my opinion better arrangement is to connect live in and input to photocell to switch position 1, connect switched live from photo cell to switch position 2 and connect feed to lights to the common terminal on the switch. Has the benefit of keeping photocell live and not back feeding the photocell which I believe causes a fault for most common types.

  • @stug45
    @stug45 3 ปีที่แล้ว

    Is it possible for a single switch to be the slave and have the PIR as the master? Ideally i would want PIR in use all the time but a switch to make the light stay on until the switch is set to off - i dont need the centre off position and ideally i just want a pull cord

  • @wisher21uk
    @wisher21uk 4 ปีที่แล้ว +2

    Got 2 of those led type lights with a sensor that you can turn off/on with in 3 seconds it stays on they’re blooma ones form B&Q I believe
    Only got them last year

    • @mb63
      @mb63 4 ปีที่แล้ว +1

      Cucumber Man yes, they are definetly still on sale.

    • @wisher21uk
      @wisher21uk 4 ปีที่แล้ว

      Michael Birchall I’m glad because I think one is on its way out lol 😂

  • @cloud7979
    @cloud7979 2 ปีที่แล้ว

    Thanks for the help always get confused with wiring of lights. The second option you have if there are two rooms that are to be controlled separately. We would just need a live connector as well same as earth and neutral and just supply both switches from there I suppose?

    • @jwflame
      @jwflame  2 ปีที่แล้ว +1

      More lighting circuit info here: www.flameport.com/electric/lighting_circuits/index.cs4

    • @djturbine7565
      @djturbine7565 2 ปีที่แล้ว +1

      You would ideally loop the supply in and out of each switch, connecting through the neutral and earth cores in a wago or similar and linking the line via the common terminal in the switch.

  • @RandomRoshProduction
    @RandomRoshProduction 2 ปีที่แล้ว

    Hello John great video again re sensor wiring. sorry to be dense but I have a steinel dusk to dawn and has N L' N L Connections on the sensor. 4 lights. I have wired in the live and neutral from the supply and the other N I put the neutral from the first light and the L' I put the live from the light and the switch line from the live. unfortunately I only have the first light coming on and the other 3 are not coming on. I have checked and all the lights are serviceable ....HELP !!!!

  • @rimasp4769
    @rimasp4769 ปีที่แล้ว

    Amazing

  • @jodyking8754
    @jodyking8754 4 ปีที่แล้ว

    can you connect 2 sensors to one wire system and what if one sensor fails will my system pick it up i have a adt alarm system

  • @Scotkruz
    @Scotkruz ปีที่แล้ว

    Think 2 gang switch was totally un necessary.. the SL from the PIR could have gone straight to the light.
    What is the benefit of the overide?

  • @andyvaughan5901
    @andyvaughan5901 3 ปีที่แล้ว

    Hi JW great videos. I am trying to work out unsuccessfully in my head how to wire up multiple sensors to multiple lights, with any sensor activating all of the lights. The system is up a stairwell.
    Thanks for any response 🙂

    • @baldyslapnut.
      @baldyslapnut. 4 หลายเดือนก่อน +1

      3C+E chaining all the PIRs together, then back to switch control point as per JW's diagrams. Any sensor triggers all lights. You probably worked that out by now of course...

  • @nicholaspratt7934
    @nicholaspratt7934 4 ปีที่แล้ว +9

    You missed pointing out that in the dusk to dawn photocell the arrow has to point North to work correctly.

    • @millomweb
      @millomweb 4 ปีที่แล้ว

      Interesting point but I've not come across a direction dependent sensor !

    • @Mark1024MAK
      @Mark1024MAK 4 ปีที่แล้ว +1

      Nicholas Pratt - that’s fine for us in the south of the country, but if you are already ‘up North’, which way do you point it 🤣

    • @millomweb
      @millomweb 4 ปีที่แล้ว +2

      @@Mark1024MAK Further north !

    • @beardyface8492
      @beardyface8492 4 ปีที่แล้ว +1

      Santa is screwed then, he can literally only point it due south!

  • @0x00zero
    @0x00zero 3 ปีที่แล้ว

    I watched this to answer one question: Is it really OK to backfeed the PIR output. For an old 'relay' sure. What if it's a semiconductor?

  • @martymac2650
    @martymac2650 2 ปีที่แล้ว

    Love your vids JW, but I’ve come across this so many times… and I hate this method… if you put switch to auto, day or night, the sensor has to settle for a couple of minutes, and if it’s a photocell it will start clicking and almost certainly mess up due to back feeds. I usually connect mains to L1 and auto sw back to L2, with sw to the light connected to common. This way there is no back feeds and no sensor settle time…

  • @LafaTV
    @LafaTV 4 ปีที่แล้ว

    What if your working with just 2 wire cable on a 12v system?

  • @edmundskipper455
    @edmundskipper455 2 ปีที่แล้ว

    A great video John. Do you know whether it is possible to use a PIR with a 1500 watt electric radiator? If so how would it be wired?

    • @spjelectrical2940
      @spjelectrical2940 ปีที่แล้ว

      use a contactor if it cannot cope with the load

  • @arronnorton3072
    @arronnorton3072 4 ปีที่แล้ว +9

    Can we have more on lighting circuit types please

    • @davidlewis4162
      @davidlewis4162 4 ปีที่แล้ว +1

      arron norton there’s plenty on TH-cam, search 2plate 3plate methods

  • @piratedprivacy9052
    @piratedprivacy9052 4 ปีที่แล้ว +1

    Sir JohnW, may I add that for the 1st diagram with 2switches used i.e. 2Gang2Way, its sufficient to use 1WAY switch for both the switches there.
    Am I correct or otherwise?

    • @MrDumbdane
      @MrDumbdane 4 ปีที่แล้ว

      You are correct.

    • @jwflame
      @jwflame  4 ปีที่แล้ว

      Yes. They are drawn as 2 way because 2 gang switches are almost always 2 way types.

    • @piratedprivacy9052
      @piratedprivacy9052 4 ปีที่แล้ว +1

      John Ward Oh thanks for that bonus info...
      Outside UK but countries that still based itself to bs, its more common to find 2g1w , 3g1w, 4g1w and even 5g1w. its not common to spot 1g2w or 2g2w unless we really need those for 2way switching etc.

  • @EmpoweringElec
    @EmpoweringElec 4 หลายเดือนก่อน

    Hi JW, Is there a way of incorporating an override switch in a 2 way or intermediate switch setting?

    • @jwflame
      @jwflame  3 หลายเดือนก่อน +1

      A double pole switch used to connect all 3 wires together would turn the light on, and prevent it being turned off from any of the other switches.

    • @EmpoweringElec
      @EmpoweringElec 3 หลายเดือนก่อน

      @@jwflame Thank you for your reply... I thought there might have been some sort of new invention to be able to have a 3 position switch from multiple location 🤯 without making things complicated for the customer.
      Much love from Australia, thank you for sharing your knowledge.

  • @sundaybighouse
    @sundaybighouse 4 ปีที่แล้ว +1

    if wiring the on off on in singles could you connect SL directly to light Line and another single from L2 directly to light L?

    • @millomweb
      @millomweb 4 ปีที่แล้ว

      That sounds like the same difference but without the SL going via the switch again.

  • @jlaw8882
    @jlaw8882 5 หลายเดือนก่อน

    What if you had 3 PIR sensors on different sides of a small building that all worked a single bank of say 4 lights? The total lighting load within the PIR's Amp loading. Can that be done even if 2 or all 3 PIR's were at some point tripped and passing current?

    • @jwflame
      @jwflame  5 หลายเดือนก่อน +1

      Yes. Current would be shared between the PIRs if more than one was active, but that doesn't matter.

    • @jlaw8882
      @jlaw8882 5 หลายเดือนก่อน

      @@jwflame Thanks for the reply. I am about to wire it all up and using a 10A contactor for the 4 lights to take the load off the PIR's.

  • @monicaissa5966
    @monicaissa5966 4 ปีที่แล้ว +1

    Thank you for sharing this information as I found it very useful.
    Please if you can help me on the below, I be most grateful.
    I like to install a flood light with an external PIR sensor, similar to the 1 way switch design you show. The only problem is the current set up I have uses a switched fuse spur instead of a 1 way switch. I only want the light to stay in the PIR mode or off completely.
    From this can I directly connect the switched line output from the PIR to the light? If not, please can you explain so I understand.
    Thank you most kindly.
    Matt

    • @jwflame
      @jwflame  4 ปีที่แล้ว +1

      Yes, LNE from the spur to LNE in the PIR, light connects to PIR switched L, N&E

    • @monicaissa5966
      @monicaissa5966 4 ปีที่แล้ว

      Thank you very much for this information John. Will continue to learn this profession going forward.

  • @zeebeezoey
    @zeebeezoey 4 ปีที่แล้ว

    Would it be acceptable to wire the PIR to be permanently connected, and just switch the PIR switch line? I ask because many PIR sensors switch on when initially powered, but you may want to be able to set the light to auto without having it illuminated.

    • @jwflame
      @jwflame  4 ปีที่แล้ว +1

      Yes, that would work.

  • @rodgerq
    @rodgerq 3 ปีที่แล้ว

    Great video! Why must an earth be taken to one of these twist on dusk till dawn sensors when 1. It's plastic, and 2. there isn't even a termination point for it? Seems like a pointless endeavour to me.

  • @BillyWard
    @BillyWard ปีที่แล้ว

    Great video - you have a way with words and making things simple. One question: Can I have a PIR to turn low-level mood lights on (like decking-type lights) in my bathroom BUT also have the main bathroom lights connected to the mood lights - so that ALL lights come on from the main switch BUT ONLY the low level mood lights come on via the PIR? This is to have the low-level lights come on in the middle of the night for a bathroom visit. My diagram suggests that the mood lights will pass on the current to the rest of the lights so the PIR will sadly turn EVERYTHING on. I'm wracking my brains to see a workaround. And believe that YOU have the answer! :) Cheers

    • @jwflame
      @jwflame  ปีที่แล้ว

      You will need a relay. 230V coil connects to the existing lighting, and the contacts of the relay connected in parallel with the contacts of the PIR.

    • @BillyWard
      @BillyWard ปีที่แล้ว

      @@jwflame Mmmm thinking hard John. So the existing wiring when turned on - switches the relay to 'on' and therefore lights the low-level mood lights. But - the low-level lights if turned on by the PIR are not directly connected back to the existing lights, so, therefore, won't just turn everything else on! I think I have it! 😁 (Supplementary Bonus question: Do you know of such a relay? Looking online they look like they would sit in a sort of Consumer Unit setup).

    • @BillyWard
      @BillyWard ปีที่แล้ว

      @@jwflame And mega thanks for the reply John - I've had sleepless nights thinking about this satanic dilema! :)

  • @Displays.1234.
    @Displays.1234. ปีที่แล้ว

    I have a question, just fitted a pir in the bathroom, but it stops working if we use the shower, I guess the infrared won't pick up though the shower glass, is the microwave version going to work better.....

    • @jwflame
      @jwflame  ปีที่แล้ว

      Yes, microwave will work through glass. However make sure to get an adjustable one, otherwise it will also work through the door, window and in some cases through the floor/ceiling into other rooms.

    • @Displays.1234.
      @Displays.1234. ปีที่แล้ว

      @@jwflame thanks for letting me know that...

  • @joefriday6324
    @joefriday6324 2 ปีที่แล้ว

    What if you want to have the left switch be the on/off to the power to the auto sensor/light combo....... and have the right side switch make the light turn permanently on or permanently off override to the sensor light? Is that possible? If I am understanding this correctly; the right side switch in your illustration would either allow the sensor/light to be in sensor 'auto' mode, or sensor 'always on' mode..... but to turn the entire sensor/light 'off'..... requires the left side switch to be in the 'off' position, if you wanted to keep the sensor/light completely 'off/disabled.' Can't it be wired so the right side switch overrides the sensor/light normal operation of the left side switch by turning the light permanently 'on' or permanently 'off?' or, is that overly complicating things?

    • @jwflame
      @jwflame  2 ปีที่แล้ว

      If one switch is wired to permanently turn the light on or off, then it's just a normal switch. The other one will do nothing.

  • @jnevercast
    @jnevercast 6 หลายเดือนก่อน

    For whatever reason, the setup on the second switch in the first setup makes me uncomfortable. I'd have rather seen the live go from the first switch, and jump to the left hand terminal of the second switch, rather than the common. Then the light connects to the common, and the sensor connects to the right hand terminal of the switch. This way, on and off behaves as expected, and the auto switch either goes from left to common to light (always on), or live goes from first switch, to pir, to right terminal to common, to light. In this configuration there is only ever one live path to the load and no loops.
    I don't mind loops in DC systems, but they make me upset in AC. I'm not sure if that sentiment is based in reality.

  • @democracyforall
    @democracyforall 4 ปีที่แล้ว +1

    Dear John Ward, if you can do one video on emergency lighting. In my workplace I do allot of emergency lighting and sensors, the sensors are fine for me but the emergency one is confusing. Some have back up battery supply and bypasses the ballast or relay and has different wiring. I tried to find the source of the power when the light is not on but was told it gets its power from battery? When I do the emergency lighting testing- I switch off the lights and the emergency lights come on- was asking the chief Engineering if he can explain where it is getting its power from? but he is not a qualified electrician so avoided the answer. If you can do one video on it, will be grateful. Thank you.

    • @millomweb
      @millomweb 4 ปีที่แล้ว +1

      They all have back up battery ! SOMEWHERE ! There are self contained units that have a battery in the light and there are lights fed from a central battery in the building - that's 'old style' but still valid. (And probably far better !)

    • @Mark1024MAK
      @Mark1024MAK 4 ปีที่แล้ว +2

      The vast majority of emergency lights, or lights with an emergency mode have an internal battery. When supplied with mains power, a charging circuit charges the battery. When mains fails, the battery supplies an electronic module, which in turn powers the light.

  • @alexray775
    @alexray775 3 ปีที่แล้ว

    Hi John, I have a 400W Halogen floodlight with a PIR. Is there a way I can add another PIR sensor as well as the one on the light?

    • @jwflame
      @jwflame  3 ปีที่แล้ว +1

      If all 4 terminals are accessible (L,SL,N,E) then yes, just connect another sensor to those.

    • @alexray775
      @alexray775 3 ปีที่แล้ว

      @@jwflame thank you!

  • @youssefabimikhael1250
    @youssefabimikhael1250 ปีที่แล้ว

    Every time I turn on the ON/OFF switch ( please note the PIR switch is in auto) the sensors click many times and the down lights flashes many times. After that the system settles. I am using exactly the same first configuration.
    Can someone advise? Thank you.

  • @michaelcostello6991
    @michaelcostello6991 2 ปีที่แล้ว +1

    Could you send 230 volts to the sensor switched live without disconnecting the sensor permanent live ? ?? This might be an option in an existing installation where you wanted to add a override switch in a different location without touching the existing wiring .

    • @jwflame
      @jwflame  2 ปีที่แล้ว +1

      Yes, that will work. On most the output is just a relay contact, so it won't damage anything by connecting it to L externally.

    • @michaelcostello6991
      @michaelcostello6991 2 ปีที่แล้ว

      @@jwflame Thanks . The PIR i just ordered showed in the online specification sheet that it can be manually bypassed this way

  • @derekt7606
    @derekt7606 4 ปีที่แล้ว

    Jeepers that made sense to me second viewing 👍

  • @AndyK.1
    @AndyK.1 4 ปีที่แล้ว

    Most pirs and lights still have the override facility. Some will stay on till dawn.

  • @mohibulhassan
    @mohibulhassan 3 ปีที่แล้ว +1

    Where can I get that single switch John was talking about? What is the name of that switch?

    • @jwflame
      @jwflame  3 ปีที่แล้ว

      uk.farnell.com/mk/k4899whi/grid-plus-switch-2-way-off/dp/3458766

  • @abscomm
    @abscomm 4 ปีที่แล้ว

    Is it possible to get a sensor with both microwave and PIR technology that requires both types to be tripped before the circuit completes? Wouldn't this be the best solution?

    • @jwflame
      @jwflame  4 ปีที่แล้ว +2

      They exist, but are typically used for intruder alarm systems rather than stand alone sensors for lighting.

    • @abscomm
      @abscomm 4 ปีที่แล้ว

      @@jwflame Thank you.

  • @NevDunn
    @NevDunn 10 หลายเดือนก่อน

    how do I wire to an existing light. Can it be wired direct to the light fitting?
    Anyone?

  • @Tommyinoz1971
    @Tommyinoz1971 4 ปีที่แล้ว +3

    Is it possible to join two PIRs to a single light fixture?

    • @baldyslapnut.
      @baldyslapnut. 4 ปีที่แล้ว +2

      Yes just extend the 3C +E from pir 1 to any number of additional pir sensors.

    • @Mark1024MAK
      @Mark1024MAK 4 ปีที่แล้ว +1

      Thomas McBurney - only if both sensors use a relay contact to perform the switching. If the sensor uses solid state switching, the sensors may be damaged if wired in parallel.

  • @Feirypackman
    @Feirypackman ปีที่แล้ว

    Hello I've looked at all your videos but cannot find a microwave sensor with manual overide. I'm trying to fit a V-TAC VT-8077 Microwave Sensor 360° white with manual Override Function to 240v battern lights in my workshop , it has four connectors N NL L middle connector for load I've connected all to power fine, but the light keeps tripping the house RCD, I've connected the earth cable from the power to the load lead, could this be causing the problem, not sure how or where the earth's should be connected, your help, or anyone's help would be desperately appreciated.

    • @jwflame
      @jwflame  ปีที่แล้ว

      RCDs trip on earth faults, which will either be L to E or N to E.
      As the sensor has no E connection, it's not the sensor causing it. More likely incorrect wiring at the lights or a damaged cable.

  • @caplemillings2644
    @caplemillings2644 3 ปีที่แล้ว

    What makes the Bob blowing ofthin

  • @michalkrolik3021
    @michalkrolik3021 4 ปีที่แล้ว

    hi guys i wanted to have two sensors (on two ends of the wall) activating one section of lighting. Is this correct to connect second PIR in series with the first one??? thanks for help anyone!!!

    • @jwflame
      @jwflame  4 ปีที่แล้ว +1

      Cable between the two PIRs, each terminal connected to the same terminal in the other PIR, so L-L, N-N, SL-SL, E-E.

    • @michalkrolik3021
      @michalkrolik3021 4 ปีที่แล้ว

      @@jwflame very appreciate thank you John

  • @AndyK.1
    @AndyK.1 4 ปีที่แล้ว +1

    Where can you get household 3 position switches?

    • @jwflame
      @jwflame  4 ปีที่แล้ว +2

      This: www.cef.co.uk/catalogue/products/506614-10a-3-position-switch-module-polar-white
      or this: www.cef.co.uk/catalogue/products/506614-10a-3-position-switch-module-polar-white
      There are probably others.

    • @heffo1992
      @heffo1992 4 ปีที่แล้ว

      Could you do a video on how to link two PIRs to control the same light?

    • @beardyface8492
      @beardyface8492 4 ปีที่แล้ว

      @@heffo1992 The obvious solution would be to link them in parallel using 3 core + E, chain as many as you like together, any one triggers the light comes on.

  • @kesavankasi4786
    @kesavankasi4786 7 หลายเดือนก่อน

    HI. my PIR sensor does not have a SL terminal. What can I do? Thanks

    • @jwflame
      @jwflame  7 หลายเดือนก่อน

      May be marked Load or something similar. It must have one, otherwise it would be useless.