2 stage compressor Changeout

แชร์
ฝัง
  • เผยแพร่เมื่อ 31 มี.ค. 2021
  • Change of a compressor on a Bryant 2 stage system.
    #hvac
    #bryant
    #compressor
    #repair

ความคิดเห็น • 48

  • @HVACGUY
    @HVACGUY  3 ปีที่แล้ว +4

    I appreciate the suggestions. As I work by myself, i learn from guys like you.

    • @scottk0623
      @scottk0623 3 ปีที่แล้ว

      I also am a one man operation, been doing this over 35 yrs. I still learn everyday. Thanks for the videos, nice work.

  • @donnierobertson3088
    @donnierobertson3088 3 ปีที่แล้ว

    Nice job and video like always

  • @Brad.W
    @Brad.W ปีที่แล้ว +2

    I dont think i have ever seen an ac unit big enough for someone to get down inside of it without tearing the Fins up.

  • @NuttyProfessor-
    @NuttyProfessor- 3 ปีที่แล้ว +1

    I love all y'all who get down on hvac

  • @cutum
    @cutum 3 ปีที่แล้ว

    Nice work!

    • @HVACGUY
      @HVACGUY  3 ปีที่แล้ว

      Thanks!

  • @unabridgeddick6645
    @unabridgeddick6645 หลายเดือนก่อน

    I wish I could fit in there with my tall self 🤣

  • @jacobreed1087
    @jacobreed1087 3 ปีที่แล้ว +5

    I always put a heat gun on those accumulators when reclaiming. Seems to work most of the time

    • @jakem117
      @jakem117 3 ปีที่แล้ว +2

      "Recover" Not reclaim...

    • @shannonhill3356
      @shannonhill3356 6 หลายเดือนก่อน

      Reduce, reuse, recycle

  • @chriscermak3188
    @chriscermak3188 3 ปีที่แล้ว +4

    Never seen anyone crawl inside a condensing unit before. Whatever works

    • @HVACGUY
      @HVACGUY  3 ปีที่แล้ว +1

      That thing was four feet tall. It was either that or remove the coil. Fortunately there was plenty of room in there.

  • @hkhsm359
    @hkhsm359 3 ปีที่แล้ว +1

    Nice job. Great installation. Keep posting , like your videos

    • @HVACGUY
      @HVACGUY  3 ปีที่แล้ว

      Thanks 👍

  • @joecephus352
    @joecephus352 3 ปีที่แล้ว

    Ive used a fan in the past as a powered exhaust...if your lucky you can set it to low speed and prop it agaisnt the wall.

  • @ryanscho9207
    @ryanscho9207 ปีที่แล้ว

    Is it recommended to remove an old line drier located inside the condensing unit?

  • @davidcruickshank2419
    @davidcruickshank2419 3 ปีที่แล้ว

    Quick question, what size tip do you use for brazing. It might be just the way it looks in the videos but it seems the flame fans out like a spray gun. BTY, nice work!

    • @HVACGUY
      @HVACGUY  3 ปีที่แล้ว

      i just looked and it’s a 3. I may do a video on proper way to braze. I’ve seen many people not mix their acetylene and oxygen correctly. the way mine appears May be more due to how I mix the flame, than the tip.

    • @davidcruickshank2419
      @davidcruickshank2419 3 ปีที่แล้ว

      I use a #2..... I’m gonna have to go play tomorrow with the adjustments and pressures tomorrow lol. Thanks for responding 👍

  • @ThePete2432
    @ThePete2432 3 ปีที่แล้ว

    Those are tough jobs, I’d rather do it like you did than remove condenser coils... units always end up rattling when I pull them all the way apart

  • @JazweenA221
    @JazweenA221 2 ปีที่แล้ว

    How heavy compressors are? (tell in kilogram please)

  • @Empty7775
    @Empty7775 ปีที่แล้ว

    Do you cut the vapor and liquid lines from the compressor or do you torch them out? Im doing one now and the 7/8” vapor line is giving me a hell of a time.

    • @shannonhill3356
      @shannonhill3356 6 หลายเดือนก่อน

      Most guys get on my ass but I prefer to torch em out (but I always flow nitrogen anytime heat hits refrigerant lines, too). I know it’s never “safest” because flame out and popping but I do.
      ….unless it’s 7/8. Then I’m willing to cut and junctions even if needed usually. My turbo torch air/acetylene kit with the big tip can actually get those 7/8 all right, but it’s still a pain to maneuver 7/8 so damn rigid

  • @shannonhill3356
    @shannonhill3356 6 หลายเดือนก่อน

    My dude. Respirator. Nitrogen flow. Every time, I do these things. I’m four years in. Respirator isn’t even gonna get it all but better than nothing with appropriate filter.
    Also, heating that accumulator up with heat gun or even just a hose would help boil that junk off.
    Idk, my buddy and I are anal as hell about keeping peoples shit clean and running good. Time is money, but good habits in setup and tear down don’t cost much. Video is two years old and you did a good repair just saying. Good catch on strapping that wire too.

  • @joestinson7195
    @joestinson7195 3 ปีที่แล้ว

    i agree using heat gun to get refrigerant out of accumulator

  • @onenikkione
    @onenikkione 3 ปีที่แล้ว

    We just purchased a American Standard System. The inside walls are not smooth like this unit (ours has aluminum Spine Fins) may make jumping inside not possible?

    • @shannonhill3356
      @shannonhill3356 6 หลายเดือนก่อน

      Yeah, I’m a pretty thin guy but with the AmStan/Trane units they tend to have really wide-wound coils I’m pretty easily able to get in em but for some guys yeah can be tough and may even require a second hand to pull a 5t compressor from.

  • @txmade72
    @txmade72 ปีที่แล้ว

    Yes sir got me a mask once I got a wiff of fumes in hvacr school. My chest was congested had me spitting up all kinds of nasty phglem

  • @miguelsanchez9789
    @miguelsanchez9789 3 ปีที่แล้ว

    What’s that compressor handle/tool you used to lift the compressor called?

    • @HVACGUY
      @HVACGUY  3 ปีที่แล้ว

      Im not sure. I bought it at my local HVAC supply store.

    • @coolmandude1000
      @coolmandude1000 3 ปีที่แล้ว

      Compressor tote tool.

  • @scottk0623
    @scottk0623 3 ปีที่แล้ว +1

    I know it’s not ideal but the few times I have been in your situation with phosgene gas potential I recover the charge then leave an old vacuum pump run overnight. That really helps boil out the rest of the gas. Unfortunately time is the issue but stay safe.👍

    • @jakem117
      @jakem117 3 ปีที่แล้ว +2

      R410a Can't create phosgene gas. only chlorinated refrigerants can.
      However, I agree refrigerant decomposition is nasty..

    • @scottk0623
      @scottk0623 3 ปีที่แล้ว

      @@jakem117 100% correct, unfortunately we still service a lot of older R22 equipment

    • @Balticblue93
      @Balticblue93 ปีที่แล้ว

      You must have a garbage vacuum pump you don't care about and want to replace often. I use quality equipment and run Fieldpiece VP87's with Trublu dual hose setup. I do a double or trip evacuation in with decay tests in between in less than 45-60 minutes. Leaving a pump running all night will just burn it out. That makes zero sense at all unless you are talking massive tonnage RTU's.

  • @chesneyquinn2377
    @chesneyquinn2377 3 ปีที่แล้ว

    I was a little concerned about sanding open end copper pipes.

    • @HVACGUY
      @HVACGUY  3 ปีที่แล้ว +2

      You gotta prep that surface though. It makes for an easy weld.

  • @Brad.W
    @Brad.W ปีที่แล้ว +1

    Sounds like someone doesn't know how to run a weed eater or hedge trimmer whatever that is it's running in the background should never let fully off the trigger in between passes maybe let off a little bit but not all the way and unless you like replacing the engine every season that's really hard on the clutch.

  • @josetrevino9869
    @josetrevino9869 3 ปีที่แล้ว

    Off comment question... have you ever decided not to take a job that was recommended by an acquaintance?

    • @HVACGUY
      @HVACGUY  3 ปีที่แล้ว

      Oh yes. I regularly turn down work for various reasons, usually because I don’t wish to travel.

  • @gregs9555
    @gregs9555 3 ปีที่แล้ว

    My shot knees are hurting watching you do this lol

    • @HVACGUY
      @HVACGUY  3 ปีที่แล้ว

      I’ve been lucky with my knees and back.

    • @La2venida
      @La2venida 11 หลายเดือนก่อน

      What's the secret

  • @zesty2023
    @zesty2023 3 ปีที่แล้ว +1

    lol I've never seen anyone actually fit inside a condenser.

    • @HVACGUY
      @HVACGUY  3 ปีที่แล้ว

      it’s a big condenser