What is difference between Full Bore Valve and Reduced Bore Valve & When to use what ?

แชร์
ฝัง
  • เผยแพร่เมื่อ 4 ส.ค. 2024
  • Full Bore valves are specifically designed that can the complete flow of the fluid in the line without any restriction.
    However, Reduced bore Valve are designed such that the port size is slightly smaller that the line ID and hence there is some restriction to the flow.
    There are several reasons to be considered before selecting reduced bore or full bore valves
    🔴 Below is the link to free E-book on Engineering PIP standards 🔴
    www.asad-shaikh.com/newslette...
    0:00 Introduction
    0:10 Full Bore Valve
    0:38 Reduced Bore valve
    1:34 Selection Criteria Number 1
    3:04 Selection Criteria Number 2
    3:53 Selection Criteria Number 3
    4:24 Selection Criteria Number 4
    5:00 Selection Criteria Number 5
    6:05 FREE E-book on Engineering standards
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 20

  • @AsadPassionateEngineer
    @AsadPassionateEngineer  ปีที่แล้ว

    🔴Link to Instrumentation Crash Course for Professionals (FREE course)
    1500+ Students have already taken this course.
    👉asad-shaikh-instrumentation.ck.page/06e66ac455
    Students have said to make the course course PAID (Because of the value they received from the course)
    Let me know your feedback

  • @abdulafeel9233
    @abdulafeel9233 2 ปีที่แล้ว +1

    Simple and dimple, Thanks Asad

  • @ankurbhatnagar4459
    @ankurbhatnagar4459 2 ปีที่แล้ว +1

    Kudos Asad

  • @adityakirpalani3072
    @adityakirpalani3072 2 ปีที่แล้ว +2

    Excellent explanation sir

    • @AsadPassionateEngineer
      @AsadPassionateEngineer  2 ปีที่แล้ว

      Thank you for your kind words of appreciation and yes for motivating me in the past as well Aditya !! 😊

  • @industrialsolutions8138
    @industrialsolutions8138 2 ปีที่แล้ว +1

    Gr8 video.

  • @UDAYKumar-rm5bj
    @UDAYKumar-rm5bj ปีที่แล้ว

    U guys are mainting good clarity can i get u r pdf egarding valves. plzzz help me in learning

  • @sysm7562
    @sysm7562 2 ปีที่แล้ว +2

    Whenever you are using Valve as an isolation valve for installing the Sample probe, since the Sample probe shaft i.e. pipe shall pass through that valve, FULL BORE valve is used.
    You may add this point as one of the criterias where application of the valve is taken into consideration.

    • @AsadPassionateEngineer
      @AsadPassionateEngineer  2 ปีที่แล้ว

      Oh wow good point to be noted.
      Thanks for sharing your knowledge 😃

  • @thanhhoangvan-nv7fv
    @thanhhoangvan-nv7fv ปีที่แล้ว

    how much pressure drop of reduce bore valve in normal operation

  • @abdessamedghettas7167
    @abdessamedghettas7167 2 ปีที่แล้ว

    Thanks

  • @ashrafk8131
    @ashrafk8131 ปีที่แล้ว

    Can you provide full bore, reduced bore, standard bore dimension chart??

  • @itsmetinnie1685
    @itsmetinnie1685 ปีที่แล้ว

    Asad kindly make video related to partial stroke test requirements for on off valves

    • @AsadPassionateEngineer
      @AsadPassionateEngineer  ปีที่แล้ว

      Sure, PST is a very important topic, will start right away and thank you for your constant support and comments. it means a lot !! 😊

  • @jobybhavana
    @jobybhavana 2 ปีที่แล้ว

    Kudooos👏👏👏

    • @AsadPassionateEngineer
      @AsadPassionateEngineer  2 ปีที่แล้ว

      Thank you for your continuous motivation ☺️ it really means a lot !!!