  • In this video, I will show you how to troubleshoot a low insulation on a switchboard (applicable only to low to medium voltage system).
    A conductors insulation degrades the day it is made. That is why onboard, we do insulation resistance test.
    Hello I am Mark Roy, I am an Filipino electrical engineer, signed on as an electrician on a ship, most of my ships I have I have been to were containerships, This time, I am on a bulk carrier ship.
    I love taking pictures and videos, but not fond with speaking in front of a camera. That is why I made this video as a challenge for me. I want to progress myself in the upcoming more videos.
    If I did not torture you with my robotic voice, then please consider subscribing. It will be a huge confident boost for me. Thanks! See you soon.

ความคิดเห็น • 66

  • @lketterling
    @lketterling ปีที่แล้ว +1

    Your videos are a joy to watch and your troubleshooting methodology are explained very well. They're very useful to help teach our junior engineers the basics of troubleshooting on a ship.

  • @emmanmiclat7839
    @emmanmiclat7839 2 ปีที่แล้ว +1

    Another legit marine maintenance technician. 👏🤝

  • @BaldurKhr
    @BaldurKhr 3 ปีที่แล้ว +1

    Very useful ! We wait for more info !

  • @mitreviper
    @mitreviper 2 ปีที่แล้ว

    Very clear explanation. thanks.

  • @mr.cryosea7397
    @mr.cryosea7397 2 ปีที่แล้ว

    The best talaga basta pinoy ETO. More power to your channel sir.

  • @jayarmanalo6456
    @jayarmanalo6456 4 ปีที่แล้ว +2

    Thank you for very detailed explanation sir. ❤️ Kuddos

  • @theoryofeverything9439
    @theoryofeverything9439 4 ปีที่แล้ว +3

    Well done, it fact this is most headache job of ETO as its not an easy task not find and isolate the earth faults

  • @cyrildelacruzjr4365
    @cyrildelacruzjr4365 3 ปีที่แล้ว

    Thanks sir nandito Lang pala hanap hanap ako SA TH-cam ..dito kulang makita salamat SA magandang tutorial at mahusay na pag gawa

  • @14.daninursetiawan10
    @14.daninursetiawan10 3 ปีที่แล้ว

    Thks sir, so much help 👏

  • @user-ko8zv6kj3m
    @user-ko8zv6kj3m 2 ปีที่แล้ว

    Thank you!

  • @Historyofiraniankingdom
    @Historyofiraniankingdom ปีที่แล้ว

    Bravo 👍

  • @aravindraj8205
    @aravindraj8205 4 ปีที่แล้ว +1

    Very nice sir

  • @ertugrul5349
    @ertugrul5349 ปีที่แล้ว

    Good information...

  • @alexpornes7182
    @alexpornes7182 11 หลายเดือนก่อน

    Ayos lods simple at klaro demonstration

  • @blockchainJP
    @blockchainJP 4 ปีที่แล้ว +1

    Nice

  • @user-oi7xx6gr3b
    @user-oi7xx6gr3b 3 ปีที่แล้ว

    Cool!

  • @hero795
    @hero795 3 ปีที่แล้ว +1

    Useful video. well done

  • @eduardoiifuderanan7618
    @eduardoiifuderanan7618 3 ปีที่แล้ว +1

    Thank you sir, crane nmn sunod sir, common troubleshooting. Thanks safe voyage

  • @icefaceboy
    @icefaceboy 3 ปีที่แล้ว

    Thanks, from electrical cadet on viking sea :D.

  • @bobmagalong1332
    @bobmagalong1332 2 ปีที่แล้ว

    Galing nyo boss

  • @srinathgopinath7964
    @srinathgopinath7964 3 ปีที่แล้ว

    Nice background music nd expln.

  • @delaryan1
    @delaryan1 3 ปีที่แล้ว

    Good day Mark, Thanks for the video, it’s really entertaining…. But for a load like tv, you think is it possible to deteriorate the insulation of the wires? Thanks again

  • @krushangtandel2992
    @krushangtandel2992 4 ปีที่แล้ว +2

    Love from India 🙌🏼

  • @kevinmarpa568
    @kevinmarpa568 3 ปีที่แล้ว +1

    nice sir.

  • @cremonam7936
    @cremonam7936 3 ปีที่แล้ว

    Is it gonna be replaced while the ship at port, or for class repair ?

  • @andriyivanov4810
    @andriyivanov4810 4 หลายเดือนก่อน

    Hello! I am an engineer and the insulation problem is not clear to me. Your video is great and worth seeing! At the very beginning of the video (0:46), you measured current with the tester. Could you pls provide a drawing of this connection, pls? Also, your explanation of the motor is not clear to me as well. Why if T-face grounded it shows 0 Ohm insulation? I can understand that the current will flow with the easiest path from the R-face through the grounded U-winding to the ground (1:34). I was wondering if this current will back through the T-face ground and why? And why U-winding will be burned?

  • @MarineEngineer1989
    @MarineEngineer1989 9 หลายเดือนก่อน

    Hi Roy, Do you have a good understanding of the instrument type earth leakage monitors, how they actually work?

  • @skkumawat5805
    @skkumawat5805 4 ปีที่แล้ว +1

    do you know how to apply for cruise line job i want join cruise line as an electrical job and one more question is if i am appply an an 4th engg so this p[ossible or not

  • @channacion2020
    @channacion2020 3 ปีที่แล้ว

    Wow

  • @SB-on2qu
    @SB-on2qu 8 หลายเดือนก่อน

    What are the low insulation alarm limits for 220 and 440V panels according to Panama and Marshall flags.

  • @MdRasel-hs5xn
    @MdRasel-hs5xn 23 วันที่ผ่านมา

  • @charithsuboda4064
    @charithsuboda4064 ปีที่แล้ว

    Can you explain how low insulation monitoring instrument working?? Based on DC Injection. Thanks.

  • @engineroominsights
    @engineroominsights 5 หลายเดือนก่อน

    Which editingg software do you use sir

  • @cyrildelacruzjr4365
    @cyrildelacruzjr4365 3 ปีที่แล้ว

    Ehh like at share natin Yan Lect para marami tayo matotonan ..

  • @Kidseducationalandsports
    @Kidseducationalandsports 3 ปีที่แล้ว

    Sir pa vlog nman po sa reverse power, salamat

  • @cyrildelacruzjr4365
    @cyrildelacruzjr4365 3 ปีที่แล้ว +1

    Maganda Yan Kasi actual na trouble shooting Lect

  • @engronboard3605
    @engronboard3605 3 ปีที่แล้ว

    Thanks for the bright info sir, tanong lang po sana ako ano po editor gamit nyo for making Schematic diagram, galing kasi!

    • @markroymangrobang1072
      @markroymangrobang1072  3 ปีที่แล้ว +1

      Thanks sir. Lumafusion po gmit ko sa ipad. Mejo hassle ang procedure sir. Kaya nman yata sa ibang editor apps.

  • @captain_lare
    @captain_lare ปีที่แล้ว

    what dose mean TPYC-38 in plate name

  • @hunskhant-xq7pv
    @hunskhant-xq7pv 6 หลายเดือนก่อน

    Anong pwedeng paraan para maitago muna ang fault sakali darating n k u sa pwerto at meron psc na darating.

  • @ricardopastor7488
    @ricardopastor7488 3 ปีที่แล้ว

    Sir Anong Tawag mo sa tatlong ilaw Sa switch board at Anong ibig sabihin nyan?

  • @user-dx3jt9ur9b
    @user-dx3jt9ur9b 9 หลายเดือนก่อน

    Sir.kung ok lng po sa inyo,pwede po ba malaman kung ano-anong reading nakuha nyo po sa linya?

  • @dhomzbon6979
    @dhomzbon6979 4 ปีที่แล้ว +1

    Hello sir .parequest po sa insulation testing of ng machine .salamat po .

    • @markroymangrobang1072
      @markroymangrobang1072  4 ปีที่แล้ว

      Meron ako video sana sir kaso nabura ko mga vids. Anyways.
      The most ideal way to test insulation of a machine is when it is in running condition. Kasi andun yung mga factors like temperature, vibration, etc2. Pero hindi kaya i-insulation test mo ang machine while energized. The closest we can achieve this ideal way is to check before and after run for few minutes. Tapos before mag test dapat may good ground ka, hindi naka energized ang machine. For low to medium voltage machine, spot-type lang, mga 1minute lang na i insulation test. Sana nakatulong. Salamat.

  • @BongButingting
    @BongButingting 2 ปีที่แล้ว

    common problem experienced in ship

  • @GodricThe
    @GodricThe 2 ปีที่แล้ว

    simple wire marking would make the process much faster

  • @quantified7535
    @quantified7535 3 ปีที่แล้ว +1

    Sir pwede rin naman na patayin mo isa isa yung breaker, tas pag nawala yung low insulation, yun na yung problema sir. Alam mo na. Pwede din naman yun di ba

    • @vanpore6326
      @vanpore6326 3 ปีที่แล้ว

      Yun nga ginawa nya diba. Hinanap lang nya specifically kung saan ang problema. Mas mabuti nga nahanap nya kaysa i isolate lang ang breaker which karamihan ng elec ginagawa tamad na nahapin yung saan nag short.

  • @meeraal719
    @meeraal719 3 ปีที่แล้ว

    What is the Meaning of low insulation?

    • @mitreviper
      @mitreviper 2 ปีที่แล้ว

      Wirings and cables have the copper conductor core and insulation surrounding. as time goes by, this insulation material may deteriorate over time. and current will leak to the ground. the metal hull in this case.

  • @dwiyogapratama8823
    @dwiyogapratama8823 3 ปีที่แล้ว

    Please subtitle Indonesia

  • @bobmagalong1332
    @bobmagalong1332 2 ปีที่แล้ว

    Pwede ko po ba kayo add sa messenger? 1st time elect. Po ako sa bulk, and if I have questions maybe I can ask? Thanks for replying

  • @aldrinempalmado1774
    @aldrinempalmado1774 2 ปีที่แล้ว

    Low insulation will cause a bigger problem its just a matter of time

  • @mr.klenntv8800
    @mr.klenntv8800 4 ปีที่แล้ว +1

    EE ka po ba sir?

    • @markroymangrobang1072
      @markroymangrobang1072  4 ปีที่แล้ว

      Yes sir. Registered electrical engineer po ako. Pasensya ka na kung matagal reply ko. Sa port lang kasi ako nagkaka internet. Thanks

    • @mr.klenntv8800
      @mr.klenntv8800 4 ปีที่แล้ว

      Thanks sa info lecky, just keep safe lang po and God bless

  • @abcdef-kx2qt
    @abcdef-kx2qt 3 ปีที่แล้ว

    OLD SCHOOL WOULD USE A MEGGER !!!!!!!!!!!!!!!!

    • @rscelectrical7091
      @rscelectrical7091 2 ปีที่แล้ว

      What would New school use instead ?.

    • @abcdef-kx2qt
      @abcdef-kx2qt 2 ปีที่แล้ว +1

      @@rscelectrical7091 :
      electrical hipot test !!!!!!!!!!!!!!!

    • @janechelonrico5218
      @janechelonrico5218 2 ปีที่แล้ว

      Pano mg.trace pag live sir?