FIXING 24 VOLTS LOW INSULATION | Marine Electrician

แชร์
ฝัง
  • เผยแพร่เมื่อ 4 ส.ค. 2024
  • 24 VOLTS LOW INSULATION, I consider this as part of the critical system onboard. You cannot just simply drop off any breakers as it may affect the operations of the Main Engine and Auxiliary Engines.
    It may cause blackout or slow down once essential breakers have been off.

ความคิดเห็น • 61

  • @Dilidjent
    @Dilidjent ปีที่แล้ว

    Wow, the things you are doing for future generations are pure gold my friend. God bless you!

  • @eboytheeminent831
    @eboytheeminent831 3 ปีที่แล้ว +3

    I like your touch, this is amazing. It's such a great pleasure to be in a position to explore your career. Keep it up. Congratulations.

  • @jeromewelch7409
    @jeromewelch7409 3 ปีที่แล้ว

    your an awesome diagnostician very methodical in your approach thanks for lesson.

  • @PeaceMah
    @PeaceMah 2 ปีที่แล้ว

    You da man Jake. Bravo.

  • @johncantrell614
    @johncantrell614 2 ปีที่แล้ว

    Good work. I have to admit, that one probably might have stumped me.

  • @adrianaberion8140
    @adrianaberion8140 3 ปีที่แล้ว +1

    Thanks, very informative, lalo na sa mga 3 A/E na walang kasamang electrician sa barko

    • @leckyjake
      @leckyjake  3 ปีที่แล้ว

      Thanks for the support

  • @denis_artemov
    @denis_artemov 3 ปีที่แล้ว +1

    Thanks for your great videos!

    • @leckyjake
      @leckyjake  3 ปีที่แล้ว

      Thanks for the support

  • @gavinofuedan2664
    @gavinofuedan2664 3 ปีที่แล้ว

    Superb Isolation sir

  • @bertapartv
    @bertapartv ปีที่แล้ว +1

    Very nice master

  • @reyvincentgumapac210
    @reyvincentgumapac210 3 ปีที่แล้ว

    Laking tulong to sir thank you po ngyon po ganito problema namin

  • @fcgaylan
    @fcgaylan 3 ปีที่แล้ว

    You're the BEST !!!

  • @abdalrahembarham4343
    @abdalrahembarham4343 3 ปีที่แล้ว +1

    Thanks for your info Mr.lecky
    How did you test the sensor in DG control panel ?
    and can we start the generator if there was an earth fault in it ??
    Hoping you can answer my multi answer!!!

  • @mohdkhaja2713
    @mohdkhaja2713 ปีที่แล้ว

    Lot of thanks sir.
    I take knowledge from u

  • @BroskiTheGreat
    @BroskiTheGreat ปีที่แล้ว

    Outstanding 👏

  • @kknk5072
    @kknk5072 5 หลายเดือนก่อน

    Thank you Sir.

  • @senthilanbalagan8532
    @senthilanbalagan8532 3 ปีที่แล้ว +1

    Nicely explained great job

  • @monzurhasan3583
    @monzurhasan3583 3 ปีที่แล้ว

    Thank you so much

  • @aveshgupta4252
    @aveshgupta4252 5 หลายเดือนก่อน

    Thank you 🙏

  • @MsPinks007
    @MsPinks007 3 ปีที่แล้ว

    Superb lecky sir.. waiting for your new trouble shooting videos...👍

  • @picachou8561
    @picachou8561 3 ปีที่แล้ว +1

    Galing talaga leck. Keep up the good work leck

    • @leckyjake
      @leckyjake  3 ปีที่แล้ว

      Thank you for the support

  • @dipakkumar-kk8zp
    @dipakkumar-kk8zp 2 ปีที่แล้ว +1

    Thanks 👍

  • @ionaandshienahendwonderlan1904
    @ionaandshienahendwonderlan1904 2 ปีที่แล้ว

    Idol lecky tnx for sharing

  • @viraltandel7769
    @viraltandel7769 2 ปีที่แล้ว

    please make video on DG sensors.. how to check & maintain well

  • @subhammondal6294
    @subhammondal6294 3 ปีที่แล้ว +1

    Nice video sir.
    Thank you very much sir.

    • @leckyjake
      @leckyjake  3 ปีที่แล้ว

      Thank you for the support

  • @dipakkumar-kk8zp
    @dipakkumar-kk8zp 3 ปีที่แล้ว

    Thanks dear

  • @dshinkori
    @dshinkori 2 ปีที่แล้ว

    Good keep it up

  • @dilipsangada6691
    @dilipsangada6691 3 ปีที่แล้ว +1

    Good morning sir from india

  • @kahar2011
    @kahar2011 3 ปีที่แล้ว +1

    Nice explain sir, thanks for your share..

    • @leckyjake
      @leckyjake  3 ปีที่แล้ว

      Thank you. Please like and share 😉

    • @kahar2011
      @kahar2011 3 ปีที่แล้ว

      I am electrician to, please follow my channel.. thanks

  • @shyster717
    @shyster717 2 ปีที่แล้ว

    Good material, I am also with Maersk. On Santa class unfortunatelly, when you have a 24VDC earth fault, there is an engine stop...but this fault must be only in engine control modules to let it happen.

    • @leckyjake
      @leckyjake  2 ปีที่แล้ว

      Just had on the ECU B 2 days back and good thing it was fixed immediately. I am doing this fault finding specifically for the MAN B&W engine.

  • @DANI-ru3vt
    @DANI-ru3vt 3 ปีที่แล้ว

    Sir, I would like to ask one question. If you don't mind, please tell what are things are needed before joining the ship.

  • @adityaputra6747
    @adityaputra6747 9 หลายเดือนก่อน

    Hi Jake, this is pretty much helpful. i have question. but what if the alarm comes and goes, it just triggered for few second. and back to normal. how to find the source in this situation.

  • @ShubhamSingh-bn3vx
    @ShubhamSingh-bn3vx 3 ปีที่แล้ว

    What u were checking in those sensor? IR value???

  • @scorpiomarine-electrocutio7460
    @scorpiomarine-electrocutio7460 3 ปีที่แล้ว +1

    Goodpm sir leckyjake.. Mayroon ako case dito nah lowinsulation sa 24 V, nka zero ang insulation meter, P at N nag ilaw .pag ene earth test ko sya nag nonormal at infinity reading at ang namamatay na lamp indicatior ay ang N. Pag balik ko naman sa earth test switch sa normal position, mag zero at P N ang iilaw olit. Ang ginawa ko sa dc switchbaord namin, dhil may 2 breakers, (DC-A for navagitional equipments, fire alarms etc. at DC-B para sa Engine control console at main switchboard ) sa DC-A na inoff ko hindi sya nag normal, pero sa DC-B nung inoff ko nawala ang low insulation nag normal na.so doon ako SA panel board sa engine control room(DC-B)nka fuse na lng sila, 4 na fuse, ang 2 fuse ay para sa main switchboard positive at negative, at ang dalawa pang iba ay sa engine control console.. Tinanggal ko isa-isa ang positive fuse ng main switchboard, at engine control console. Wla parin,So tinanggal ko ang mga negative fuses. Sa engine control console wala parin nangyayari, pero nung ang negative fuse na tinggal ko sa main switchboard. Nwala na ang low insulation at nag infinity.
    1.)Engine control console(alarms indicators and anunciators)
    2.)DC Main Switchboard alarm (alarm circuit na may tatlong cards. Alarma Para sa low insulation 440,low insulation 100,preferencial trip at Emer. GEN. Eng. Abnormal at power ng lamp indicators sa emergency gen., (Emergency Gen. run, eng Abnormal at stanby ,
    nung tinggalan ko ito ng negative fuse saka pa nawala ang low insulation.Ngayun palang tu nagka low insulation 24v,kadalasan nmn dito ay 440v,100v.

  • @bt9604
    @bt9604 ปีที่แล้ว

    When u connect the wire to gnd both the lights should dim, how only one did, since they are in series

  • @ademothmen450
    @ademothmen450 ปีที่แล้ว

    Some ship there is not existing 24 vdc inducator of fault insulation,how to know that? Is it from 220v inducator ?!

  • @arvinagullana6679
    @arvinagullana6679 3 ปีที่แล้ว +1

    Sir.. good day.. thank you for sharing your knowledge to us especially to those who are new to the work..
    Sir, kung okay lang.. pwd ba makahingi ng tips/ guidelines on how to recover during blackout. Bago lang po ako sir. Thank you sir and God bless

    • @leckyjake
      @leckyjake  3 ปีที่แล้ว +1

      Will keep that in mind. Magandang topic yan

    • @arvinagullana6679
      @arvinagullana6679 3 ปีที่แล้ว

      @@leckyjake thank you sir jake... God bless po

  • @radhakrishna1008
    @radhakrishna1008 3 ปีที่แล้ว

    Plz make a video on power system on how 440V is converted and fed to 24V loads.. I mean from generation of 440V to different types (I.e. volts) of loads...

    • @sanaalldevcon3078
      @sanaalldevcon3078 2 ปีที่แล้ว +1

      transformer brother...and also ac/dc inverters

  • @jackpot7029
    @jackpot7029 3 ปีที่แล้ว

    Sir any idea about ang generator engine alternator, alarm low insulation 440v triggered when generator has a load, pag naka idle po wla naman alarm,...anu kaya possible problem and troubleshooting ?tanx

  • @dreamoto7251
    @dreamoto7251 2 ปีที่แล้ว

    Sir Im a newbie in ship electrician , nag trouble po yung auxillary namin hindi na po ma auto yung gobernor nya,, pwede po ba pa advice kung ano ang dahilan nito at bakit ?
    Top fan nyo po ako sir

  • @johnandes8861
    @johnandes8861 3 ปีที่แล้ว

    Sir Jake san po kaya maganda magtraining about sa marine electrical. kakatapos ko lang isang contrata ko as wiper. gusto ko rin sana maginf eto gaya nyo REE at RME din po ako.

    • @FloroJrGaray
      @FloroJrGaray 3 ปีที่แล้ว

      Try mo UMTC,NTC,GIGAMARE...May trainee cadetship sila dun sir.

  • @joelsemblante3486
    @joelsemblante3486 3 ปีที่แล้ว

    Same sa kabayo ko dto sir 24v low insulation ang hirap hanapin kac intermittent yong alarm seconds lang mawala na both navigation at sa port susulpot...

    • @leckyjake
      @leckyjake  3 ปีที่แล้ว

      Sana ma kita mo ang fault

  • @noblehormeku7326
    @noblehormeku7326 2 ปีที่แล้ว

    i will like to work with you one day on a ship one fine day kudos to you

  • @manoranjan4598
    @manoranjan4598 3 ปีที่แล้ว

    Nice medam aur banaiye video realy ke baare me

  • @ManojYadav-or6tj
    @ManojYadav-or6tj 2 ปีที่แล้ว

    Hii sr

  • @hafizanismujahid5375
    @hafizanismujahid5375 ปีที่แล้ว

    I cant understand..

  • @alfrazernudalo1060
    @alfrazernudalo1060 2 ปีที่แล้ว

    😉