How to control VFD with push button switch/ terminal control/wire control

แชร์
ฝัง
  • เผยแพร่เมื่อ 6 มี.ค. 2019
  • Buy ATO VFD online: www.ato.com/single-phase-to-t...
    This video shows single phase to three phase VFD to make the motor forward and reverse in terminal control mode(push button switch control/3 wire control).This method can start and stop the motor without approaching the VFD.
    Parameter settings in the video: P0.3=1, P4.02=9, P4.08=2
    Other basic settings video, • Run a 3-phase motor on...
    AC Contactor link,www.ato.com/ac-contactors
    Relay link,www.ato.com/electromagnetic-r...
    Switching power supply link,www.ato.com/switching-power-s...
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 54

  • @bookquotes5
    @bookquotes5 4 ปีที่แล้ว +1

    Thanks brother !!! Respect from Karachi , Pakistan..
    Can you guide us briefly about VFD basics

  • @glennedward2201
    @glennedward2201 4 ปีที่แล้ว +1

    I’m thinking about using a relay turned on by my 120v side of circuit. Switch on triggers relay for 240v. Would be nice not to have several switches.

  • @dilipdande134
    @dilipdande134 3 ปีที่แล้ว

    Good job..
    Thanks allot..legends

  • @nagarasud1441
    @nagarasud1441 2 ปีที่แล้ว +1

    Thank you 👍

  • @mahmoodalam4122
    @mahmoodalam4122 5 ปีที่แล้ว

    Very nice video

  • @fredastaire6156
    @fredastaire6156 2 ปีที่แล้ว +1

    Great video!
    Is there a such thing as using a wireless remote control for this set up?

  • @madhurao4538
    @madhurao4538 3 ปีที่แล้ว +1

    Thank you sir

  • @marloulariego9674
    @marloulariego9674 2 ปีที่แล้ว

    Is this also applicable for a 1.5 HP Single phase motor? Can i ask for the specifications for the items use in this video?

  • @markzalavari1780
    @markzalavari1780 4 ปีที่แล้ว +1

    Hi!
    How to wirelessly remote controll frequency?

  • @MichealJana
    @MichealJana 8 หลายเดือนก่อน

    nice work

  • @drakon1300
    @drakon1300 ปีที่แล้ว

    I just bought a model EM15-sp1s1-1d5 /1ph 120v ac input -1.5kw 1ph/3ph 0~220v ac 7a output vfd for my wood lathe.
    this video shows a vfd with different terminals then the one I got and not sure which terminals to use for forward - reverse ..
    none of the terminals are labeled for. rev. or X ...

  • @jaykesapalaran7001
    @jaykesapalaran7001 ปีที่แล้ว

    good tutorial, PLEASE CREAT A VIDEO HOW TO PROGRAM COMMAND IN SOFT STARTER AND VFD,🇵🇭🇵🇭🇵🇭❤

  • @fojlerabbikhan2060
    @fojlerabbikhan2060 5 ปีที่แล้ว

    Nice

  • @runbou3485
    @runbou3485 ปีที่แล้ว

    អរគុណបង🙏

  • @aymansaad7429
    @aymansaad7429 2 ปีที่แล้ว

    Good work
    I have a drive like this
    It doesn't work
    A message on screen p. Off
    No apply for programming how can I do

  • @tettehphilipkwei3905
    @tettehphilipkwei3905 6 หลายเดือนก่อน

    Please you need to show us step by step where all wires a connected practically cause people may not be familiar with some circuit diagram

  • @pv.inteless
    @pv.inteless 5 ปีที่แล้ว

    Can i have your schematic diagram !

  • @ioannisgalanos7911
    @ioannisgalanos7911 3 ปีที่แล้ว

    Hello, can i start any frequency inverter with single phase? My motor is three phase. My inverter is a RM5G. I supose must change some settings.

    • @ATOcom
      @ATOcom  3 ปีที่แล้ว

      I did not know the model you are using; but this has a dedicated VFD, such as ATO 1-phase input to 3-phase output VFD, www.ato.com/single-phase-to-three-phase-vfd

  • @darbats
    @darbats 4 ปีที่แล้ว

    I have an air compressor 10hp. Can the VFD run the motor without the Red, White, Green buttons?

    • @ATOcom
      @ATOcom  4 ปีที่แล้ว

      Yes, you can choose the control method: panel control, terminal control, modbus-RTU control, analog control.

  • @shreelaser4685
    @shreelaser4685 ปีที่แล้ว

    how can we control vfd using only limit switch

  • @judemanoharan1863
    @judemanoharan1863 3 ปีที่แล้ว

    Please send the credit wiring details

  • @ele4853
    @ele4853 4 ปีที่แล้ว +1

    is your "switch" (green button switch) momentarily on or it "toggles" between on and off at each press?

    • @ATOcom
      @ATOcom  4 ปีที่แล้ว +3

      In the video, the green button at 2:07 is a self-locking button (it is always ON after being pressed), and the green button on the rear control box is an auto-reset button (ON when pressed, and OFF when not pressed).

    • @ele4853
      @ele4853 4 ปีที่แล้ว +2

      @@ATOcom OK so the one on the 2:07min. is a ON/OFF normally open and the "Green and White" on the yellow box are Momentarily Normally Open. What is the rate of amperage and voltage for the switches on the yellow box? Thanks in advance.

    • @vfgrfbgrb
      @vfgrfbgrb 3 ปีที่แล้ว

      @@ATOcom don't understand schmetic so t1 t3 from contacter connected to vfd

  • @camron2674
    @camron2674 5 ปีที่แล้ว

    I know the objective of the video was to get remote push buttons to control VFD. So I assumed you entered the other parameters like voltage and hertz before this video was recorded...?

    • @ATOcom
      @ATOcom  5 ปีที่แล้ว

      YES.

  • @rolandiansillano3068
    @rolandiansillano3068 2 ปีที่แล้ว

    Hi sir can you give me idea how to run motor with vfd 10 hz to 50hz repeatedly

    • @ATOcom
      @ATOcom  2 ปีที่แล้ว

      You mean run at 10Hz for a while, then run at 50Hz for a while, and so on?
      1. You can use VFD two-stage speed control mode + 2 time relays, and connect a group of multi-function terminals after each time.
      2. You can use PLC to build control logic to activate a certain speed at regular intervals. VFD can choose multi-speed control or directly control VFD frequency by Modbus communication.
      ATO VFD multi-speed control mode link, th-cam.com/video/uZKsPgcB2a8/w-d-xo.html

  • @alikhalaf805
    @alikhalaf805 4 ปีที่แล้ว

    Why not use rela 220v ac allowance rela 24 v dc I am waiting for your answer, please

    • @ATOcom
      @ATOcom  4 ปีที่แล้ว +1

      24VDC is a safe voltage and 220VAC is a dangerous voltage. In the application of automation equipment, the safe voltage is usually used to control the dangerous voltage.

    • @alikhalaf805
      @alikhalaf805 4 ปีที่แล้ว

      @@ATOcom Thanks a lot for clarification. I am very grateful

    • @ATOcom
      @ATOcom  4 ปีที่แล้ว

      @@alikhalaf805 : )

  • @DemiFlower1010
    @DemiFlower1010 3 ปีที่แล้ว

    Hi i just purchased a GK3000 single phase in and out for my 3hp lathe motor. Do you have a similar scamatic for me to use so I can make a enclosure to use. The only difference I need is I want to put a variable knob on the lathe and I want to use a joystick up for forward and down for reverse. Please if you can send me a scamatic.

    • @ATOcom
      @ATOcom  3 ปีที่แล้ว

      Is this video what you want? th-cam.com/video/TJsN1gW8hVQ/w-d-xo.html

    • @DemiFlower1010
      @DemiFlower1010 3 ปีที่แล้ว

      @@ATOcom yes this helps but I have other questions not answered yet, this video is still for 3phase correct? I have single phase in and out. Am I gonna need the dc converter? And what about a scamatic for a joystick for forward and reverse control?

    • @ATOcom
      @ATOcom  3 ปีที่แล้ว

      @@DemiFlower1010 1. Yes, the video is applicable to all GK3000-2S series (including single-phase output, three-phase output VFD), but it should be reminded that single-phase motors are not suitable for long-term operation below 80% of the rated speed because single The centrifugal switch of the phase motor will not be cut off at low speed, leading to the risk of burning the motor.
      2. At present, the forward and reverse rotation of the motor can only be controlled by button, panel, and modbus communication. You can use the VFD in combination with the two videos you see.
      3. What is your purpose of using DC converter?
      4. If you encounter more troubles, please contact our after-sales team, www.ato.com/contactus

    • @DemiFlower1010
      @DemiFlower1010 3 ปีที่แล้ว

      @@ATOcom I'm not interested in the dc converter I just keep seeing it in most the videos. I purchased this for my lathe as I said it's 3hp motor. So if I set this up like I see in those couple videos how long are you saying my motor Will last? And why would single phase input and output vfd control be made if its no good for your motor? Should I return it and purchase a single phase in and 3phase out and get a 3phase motor instead? I idid not know these were not good for single phase motors or I would not of purchased. Because On a lathe I'll probably be using the lathe speed less than 80 percent speed all the time so my motor will not last long your saying correct?

    • @ATOcom
      @ATOcom  3 ปีที่แล้ว

      @@DemiFlower1010 1. The low-speed operation time of each brand of single-phase motor is different, which depends on its heat dissipation performance and the separation speed of the centrifugal switch.
      2. Single-phase input & output VFD is suitable for single-phase motors that do not run at low speed for a long time, to adjust speed or reduce the impact of the motor on the power grid.
      3. If your motor has a long-term use speed lower than 80% of the rated speed without matching the reducer, I suggest that you purchase a three-phase motor and use it with a single-phase input to three-phase output VFD (when running at low speeds, Note that the motor can dissipate heat in time)

  • @user-wk9fy4si8y
    @user-wk9fy4si8y 4 หลายเดือนก่อน

    can you give me full circuit diagram pls

  • @joaotuga7181
    @joaotuga7181 5 หลายเดือนก่อน

    Please what are the specifications of the contactor and relay?

    • @ATOcom
      @ATOcom  4 หลายเดือนก่อน

      Thank you for your inquiry sir. The specs of the contactor: 32A, 4 Pole, NO. For the relay, check out here: www.ato.com/electromagnetic-relay-dpdt-12-24-110-220v-coils

  • @sambamurthy883
    @sambamurthy883 2 ปีที่แล้ว

    Saft stater control wireing diagram plz make video sir

    • @ATOcom
      @ATOcom  2 ปีที่แล้ว

      This video, th-cam.com/video/GkSo1DOBHlM/w-d-xo.html

  • @PTinvest
    @PTinvest 2 ปีที่แล้ว

    What role of the relay

    • @ATOcom
      @ATOcom  2 ปีที่แล้ว

      Low voltage control high voltage

  • @jackb3232
    @jackb3232 4 ปีที่แล้ว

    That's smps is little overpowered,😉

    • @ATOcom
      @ATOcom  4 ปีที่แล้ว

      :)

  • @Devanfarm
    @Devanfarm 3 ปีที่แล้ว

    motor connection must be STAR or DELTA

    • @ATOcom
      @ATOcom  3 ปีที่แล้ว

      all ok