Many a times I used to touch live bushings of DTR after isolating it's earth and didn't ever get electric shock but with the concept that the circuit wasn't complete. Surprised to know that even in these conditions Circuit could get complete due to capacitance. Thank you for adding a new jewel to my knowledge.
We should always follow safety rules. As there may be knowledge gap or some unknown phenomenon. Watch my video on How we get electric shock during walking on the earth.
I knew this that the APC UPS use Isolated Transformer for precious human life safety. Once upon a time I used an isolation transformer for my clinic locale.
Sir make a video series for those UPSC Civil Service exam for those students whose optional paper is Electrical Engineering. Most of your videos is useful but make a single package playlist. And make explanation video in simple language for previous year questions....
Thankyou sir. Sir single phase me single earthing or double or three phase equipment ke liye double earthing ka KYA istamal Kiya jata hai ya nahi. Agar Kiya jata hai to kyo.
Is video me apne kaha ki pehla fault insulate neutral system me aane par ham use sense Karte hai taki use repair kiya ja sake.par ye sense ham kaise krenge?please sir reply
Insulated Natural system ma Single ya First fault ana pr kasa pata chalta hai ki fault aya h? Kayo ki isma ko MCB trip nhi hui? Isma Electric equipment wor kr rahai hai?
isolated neutral open road per nahi allowed hai safity, protection and use ki vajah sey. Mera video why transformer neutral is connected to earth dekho,
Sir if we don’t repair the first fault between phase and earth in insulated neutral system - in this condition what will be impact in PCB components or they stop working they take stress.?
G K Agrawal thanks Sir is any way to meet you we r looking a person like you who can study our site related issue and support us on remotely or some time in site commercial terms will be discuss
When using an isolating transformer in the insulated neutral, during short Ckt, why the primary side mcb will not trip? sec side mcb will not trip because there electrical isolation. if the primary mcb trips the trafo will trip.
Sir, In insulated neutral system, if we test phase wire with line tester, then the small amount of current will flow from line tester & our body and the tester bulb will flow. Then how it is possible that when there is a fault between live wire and earth, the current will not flow?
But Sir in your latest video "Electric shock by walking on the earth road without touching wire" @ time 5:48 , there you have mentioned that there can be a resistive and capacitive effect between primary and secondary and hence there is a chance of shock, So this effect will play here na, and there is a chance of shock, This is just my doubt can you please explain me this too
Sir ji 🙏🙏🙏🙏 mere yha earth to neutral 250 volt 💡 Earth to phase 407 volt 💡 Neutral se phase 235 volt 💡 aa rha h ye kaisa fault h sb kuch shi chal rha h koi dikaat nhi Dono pe tester glow 🌟 ho rha h Neutral aur phase pe 200 watt bhi glow krke dekha neutral to earth 💡 glow krta h Aur phase to earth pe full glow krta h Bhut jyada jese fuse hone wala ho 💡💡1 -2 second hi lgaya phase to earth
Neutral aur phase mein 230 volt normal h sir ji Earth se neutra aur phase mein 250 aur 400 volt aa rhe h Aur yeh ek mhine se bhi jyada ho gya isko dekhte hue transformer pe lge sbhi ghro mein shi light aa rhi h koi dikkat nhi
सर हमारे तरफ घरों में जिस खंभे से लाइट आती है उसमे न्यूट्रल है ही नहीं। केवल 3 फेस वायर ही हैं। न्यूट्रल हमलोगों ने जमीन में गड्ढा करके उससे ली हुई है। अब अर्थ कैसे लें?
Watch video on a floating system and may join ( optional) channel
th-cam.com/channels/O31rZS4_EDYJ8CGXiRZdxg.htmljoin
youtube ka sab se best chainal hai aap ka sir
Comments welcome
Awesome explanation sir... please make a video on earthing in HVDC system
आप बहुत अच्छा समझाते है sir , आपसे सीख ने मिला बहुत कुछ
धन्यवाद आपका
Many a times I used to touch live bushings of DTR after isolating it's earth and didn't ever get electric shock but with the concept that the circuit wasn't complete. Surprised to know that even in these conditions Circuit could get complete due to capacitance. Thank you for adding a new jewel to my knowledge.
We should always follow safety rules. As there may be knowledge gap or some unknown phenomenon. Watch my video on How we get electric shock during walking on the earth.
Very good explained as always
Gopal sir you rock....Simplest and most detailed explanation of everything...Best circuit diagrams....Keep up the good work.
Keep watching my all 350 videos and share link of videos on your social media to spread the knowledge.
Lajawaab shaandaar
Nicely elaborated
Wonderful and very exclusive
Thank you so much for the information..
Good Explain।।
Reactor .... please sir......
Tomar lecture Ami Khoob bhalo Lage Che.......
Always best♥️♥️
Good, that you like the video
You are great , Sir.
Sir please make a video on rotey encoder with practical
sir,nomoste
aap ka soute rohe sunkor bht acha laga
Shandaar
Very informative ......Plz make video on detailed electrical SLD
Expecting more
Insulated neutral ma phase ma tura current ka loss hoga na
I knew this that the APC UPS use Isolated Transformer for precious human life safety. Once upon a time I used an isolation transformer for my clinic locale.
Sir please MOV K say select karain is per video banayen
Love u sir thanks for your information
Sir make a video series for those UPSC Civil Service exam for those students whose optional paper is Electrical Engineering. Most of your videos is useful but make a single package playlist. And make explanation video in simple language for previous year questions....
ac power ka jagah agar dc power source ho to ckt ka behaviour same hoga ya different ?????????
Sir ek Baar sabhi electronic component ko check krne ka video banaye Jaise SCR IGBT
zener diode sur mosfet check karney key video hai
Thankyou sir.
Sir single phase me single earthing or double or three phase equipment ke liye double earthing ka KYA istamal Kiya jata hai ya nahi. Agar Kiya jata hai to kyo.
Is video me apne kaha ki pehla fault insulate neutral system me aane par ham use sense Karte hai taki use repair kiya ja sake.par ye sense ham kaise krenge?please sir reply
By monitoring voltage of the neutral. However it is advance subject. This is used in some train engine.
Sir Corona effects & farranty effects par video banay pls sir.
Sir body earth me nutral line de sakte हैं।
Question not clear.
@@GKAgrawal2 body earth me
Neutral (-) line de sakte hai
🙏🏽
Sir kya hum ghar me neutral ko earth kar sakte hai jis se mcb trip ho jaye
Good evening sir,
House wiring ke liye single line diagram par ek detail video bana dijiye..
Sir ismein pahla fall kaise pata chalega Aaya hai.
Line aur earth key beech kaa voltage measuring circuit sey measure kar saktey hai
Should we use isolation Transformer at home??
No
Insulated Natural system ma Single ya First fault ana pr kasa pata chalta hai ki fault aya h?
Kayo ki isma ko MCB trip nhi hui?
Isma Electric equipment wor kr rahai hai?
Measuring units using electronic circuit, voltage devider etc sey.
Sir Jab phase aur Earth aapas Mein short hoga to MCB trip ho jayegi lekin Agar Ham isolation Transformer use Karenge tab hi trip Nahin Hogi
Sir can we use line tester for insulated neutral system??
No
Insulated Transformer kon sa hota hai?
U need big txr. As per load size. Maha nga padega
Sir..mera sawal yeh hai electricity board wale isolated neutral kyu use nhi krte....???
isolated neutral open road per nahi allowed hai safity, protection and use ki vajah sey. Mera video why transformer neutral is connected to earth dekho,
Ok sir aabhi dekh rhe hai
Sir agar insulated neutral system me machine body phase k sath short ho jaye to current lagne k chances kitne h
Current shock sey hamesha safety rule follow hona chahiye. Watch my video, Electric shock during walking on the road.
Sir,Insulated earth system me phase jab earth se short circuit hoga, tub kya MCB trip nahi karegi👈
Eska uttar video mey hai.
Sir if we don’t repair the first fault between phase and earth in insulated neutral system - in this condition what will be impact in PCB components or they stop working they take stress.?
No problem all will work after 1st fault. But after 2nd fault, repairing becomes must, you can not wait further.
G K Agrawal thanks Sir is any way to meet you we r looking a person like you who can study our site related issue and support us on remotely or some time in site commercial terms will be discuss
G K Agrawal But sir in our case (telecom equipment) some of diodes and other components are burt?
You can connect to me at linkden profile G K Agrawal and introduce yourself and your business. You can see my detail profile also there.
When using an isolating transformer in the insulated neutral, during short Ckt, why the primary side mcb will not trip? sec side mcb will not trip because there electrical isolation. if the primary mcb trips the trafo will trip.
Watch this video again.
Sir,
Kya DC Supply me bhi same isi tarha hota hai.
No
Sir, Dharti ko agar high voltage ke line se connect karde to kya jitne log Dharti par hai unhe shock lagega?
Nahi lagegaa.
@@GKAgrawal2 sir, please kyo nahin lagega iske upar bhi ek video banaiye. Please
Yeh earth fault se related hai. Maney many videos MCB, RCCB aur electrical shock per banaye hai. Aap vah sab dekho.
Thank you
Sir agar isolation transformer ka neutral earth kr de to kya problem hone lgega
Then 1st fault mey hi trip hoga.
Apna ghar ma Leakage current kasa dunda?
Sir,
In insulated neutral system, if we test phase wire with line tester, then the small amount of current will flow from line tester & our body and the tester bulb will flow. Then how it is possible that when there is a fault between live wire and earth, the current will not flow?
Watch this video again with concentration.
Sir insulted neutral me agar earth fault ayega to earth bhi phase k potential pr a jayega kya?
No
@@GKAgrawal2 us case me kya hoga sir ? But phase ne to earth ko touch kr diya h
@@GKAgrawal2 sir thoda explain kr dijiye please
Jab kisi equipment ko earth se connect kiya ho,aur uski body per current flow kare tub kya MCB trip nahi karegi.
Mera video MCB RCCB difference dekho.
But Sir in your latest video "Electric shock by walking on the earth road without touching wire" @ time 5:48 , there you have mentioned that there can be a resistive and capacitive effect between primary and secondary and hence there is a chance of shock,
So this effect will play here na, and there is a chance of shock,
This is just my doubt can you please explain me this too
Yes, shock possible. But
MCB will not trip. As MCB require large current to trip.
@@GKAgrawal2 Thanks Sir,
🙏⏳⏳🙏
Sir ji 🙏🙏🙏🙏
mere yha
earth to neutral 250 volt 💡
Earth to phase 407 volt 💡
Neutral se phase 235 volt 💡 aa rha h ye kaisa fault h sb kuch shi chal rha h koi dikaat nhi
Dono pe tester glow 🌟 ho rha h Neutral aur phase pe
200 watt bhi glow krke dekha neutral to earth 💡 glow krta h
Aur phase to earth pe full glow krta h
Bhut jyada jese fuse hone wala ho 💡💡1 -2 second hi lgaya phase to earth
Yesa fault kaa mainey ek video banaya hai, over voltage due to neutral breaking. usko dekho.
Apkey aaspaas kisii ghar mey power nahi aa rahi hogi.
Neutral aur phase mein 230 volt normal h sir ji
Earth se neutra aur phase mein 250 aur 400 volt aa rhe h
Aur yeh ek mhine se bhi jyada ho gya isko dekhte hue
transformer pe lge sbhi ghro mein shi light aa rhi h koi dikkat nhi
सर हमारे तरफ घरों में जिस खंभे से लाइट आती है उसमे न्यूट्रल है ही नहीं। केवल 3 फेस वायर ही हैं। न्यूट्रल हमलोगों ने जमीन में गड्ढा करके उससे ली हुई है। अब अर्थ कैसे लें?
वही अर्थ है और कुछ नहीं कर सकते ।
@@GKAgrawal2 Thank you sir 🙏
Toh phir Earthed Neutral banane ki zaroorat hi kyon hai.?
Agar Insulated earth me bhi safety hai toh.....
Watch my video on We why transformer neutral is connected to earth
Sir Ghar pe hum neutral KO earth Kar sakte hai kyu sir
Nahin
@@GKAgrawal2 kyu sir
Neutral distribution transformer se break hone par 440 may Neutral earth protect karta hai
Ghar par laga hai nikal do
Please sir
Mera video Neutral earth difference dekho