What are the Differences between DCS and SCADA?

แชร์
ฝัง
  • เผยแพร่เมื่อ 21 ธ.ค. 2024

ความคิดเห็น • 140

  • @realpars
    @realpars  2 หลายเดือนก่อน +1

    Want to learn industrial automation? Go here: realpars.com
    Want to train your team in industrial automation? Go here: realpars.com/business

  • @RemixProf
    @RemixProf 5 ปีที่แล้ว +32

    I will start a new job in automation using plc and scada, thank you for sharing this knowledge. I am truly grateful.

    • @realpars
      @realpars  5 ปีที่แล้ว +4

      That is amazing! You are very welcome. Best of luck on your new job!

    • @sivakumarss7979
      @sivakumarss7979 2 ปีที่แล้ว

      Did you start your career in plc and scada?

    • @RemixProf
      @RemixProf 2 ปีที่แล้ว +2

      @@sivakumarss7979 yes i did, 2 years ago :) I have done many scada and dcs projects with different brands of plcs

    • @joshuajavier5158
      @joshuajavier5158 2 ปีที่แล้ว

      @@RemixProf In your experience Sir what is the main difference of Dcs and Scada..

  • @ardentdfender4116
    @ardentdfender4116 5 ปีที่แล้ว +30

    I’m no expert and far from it, but I happen to work in Industrial Automations Controls Systems and work for an OEM who supplies major Plant Package Water Systems to Energy Sector clients, mostly Power Plants. The difference between both SCADA & DCS used to confuse me a lot. So much so I use them interchangeably. Yet, I kinda knew some differences just harder to explain and in that SCADA was more like a mishmash of systems all controlling everything unlike a DCS with an overall unified control system. Still even when a plant has a DCS, it still has SCADA systems of sorts that operate in the field with a server and maybe the other client workstation in the DCS Room but not connected to their actual DCS. Sometimes it’s connected, sometimes it’s not from our PP customers. So customers kinda have both. It required more work though to Modbus connect it all data wise to their DCS. However, I now understand some real differences via the video. Weintek I think it’s called is another cheaper HMI similar to Redlion. Good stuff though. RealPars rules. Jabs at needing more Allen Bradley content here and on the RealPars site.

    • @realpars
      @realpars  5 ปีที่แล้ว +4

      Hi Ardent,
      Thanks for your comment and sharing your experiences! It is amazing to hear that our video has been able to clear those confusions for you.
      I will also surely forward your suggestion for some more Allen Bradley content to our creator team.
      Thanks again for sharing and happy learning!

    • @Techwem
      @Techwem 3 ปีที่แล้ว

      For more videos related to DeltaV, Honeywell, Yokogawa or ABB DCS, Visit our Channel and Subscribe.

    • @willnewcomer2125
      @willnewcomer2125 4 หลายเดือนก่อน +2

      More Allen Bradley please

  • @jsrrrmg
    @jsrrrmg 3 ปีที่แล้ว +8

    Seems like if you have multiple independent process working unified for a goal (example a poultry processing facility using Ishida, Sandiacre, Modicon, Allen Bradley which all have an equal hierarchy of control) a SCADA system is the way to go. Verses, if you have a facility that uses mainly one control system ( a power plant that has one system with main hierarchy, while able to utilize subsystems with lower hierarchies ), a DCS is they way to go.

  • @jaymehta8484
    @jaymehta8484 2 ปีที่แล้ว +2

    You're not building knowledge to today's youth but you're building thier future👍

    • @realpars
      @realpars  2 ปีที่แล้ว

      Thanks a lot for your kind compliment, Jay!

  • @AlevtinaKulikova
    @AlevtinaKulikova ปีที่แล้ว

    You really knows how to set up this indicators. Good work

    • @realpars
      @realpars  ปีที่แล้ว

      Thank you!

  • @tennisgigi1626
    @tennisgigi1626 5 ปีที่แล้ว +3

    Good explanation. This tutorial is very useful to support discussion with a non specialist of SW/HW.

    • @realpars
      @realpars  5 ปีที่แล้ว

      Thanks a lot!

  • @Haithem0007
    @Haithem0007 4 ปีที่แล้ว +1

    Thank you for your attention and the huge amount of information 🙏

    • @realpars
      @realpars  4 ปีที่แล้ว

      You are very welcome, Haithem! Thanks for your support.

  • @mohamedfaroukzmw
    @mohamedfaroukzmw ปีที่แล้ว +2

    Expected to mention the redundancy capability for the dcs as the main advantage for safety

    • @plchacker
      @plchacker 11 หลายเดือนก่อน

      Redundancy is available with AB CLX (ControlLogix.) In fact CLX offers many of the same features that the video points out as DCS specific. This focused on Siemens which in my personal opinion is far behind in technology. Siemens uses slower 16 bit processors, slower networks and their on-line capability is very limited. The programming style is very different and uses extremely limited timer functions among other irritating restrictions. If you move to Honeywell, ABB or Delta-V DCS, then certainly the differences start to appear. True DCS (Delta-V for example) is far more robust with many added safety features not found in the PLC world. One example is intrinsically safe I/O systems. Another is the built in database functionality. Safety PLC's are a different world altogether. They have comparably simple tasks and are very redundant. They are also often used in conjunction with DCS systems to provide an extra layer of safety.
      The differences between Allen Bradley and Siemens is rooted in the initial goals of design. Allen Bradley gets its roots from the original PLC team (Modicon) and kept the idea that electricians should be able to troubleshoot systems easily. The Siemens folks decided that this should be restricted to engineers and dedicated programmers. Initially, Siemens was focused on statement list programming, which is faster on the keyboard, but troublesome when you get online. Allen Bradley perfected ladder logic right from the beginning. They also focused on online capability and memory management. Both are very capable and will solve most manufacturing controls issues. I have lived and worked in both worlds.
      DCS is primarily for process controls. While it does have discrete capability, it is slow and not as flexible in the discrete world. For analog signals though DCS is difficult to beat. Even with the advanced capabilities of AB CLX, DCS still shines in the petrol-chemical and power generation worlds.

  • @QuestionableAdviser_
    @QuestionableAdviser_ 2 ปีที่แล้ว

    Easy to understand, easy to get.
    Thanks for the video

    • @realpars
      @realpars  2 ปีที่แล้ว

      Glad you liked it!

  • @julionavas5626
    @julionavas5626 2 ปีที่แล้ว +4

    Also there is an aspect regarding the geographical area of the process to supervise and control. SCADA philosophy is more appropiate for macro control of a process distribuited geographically, like a Power Utility System, where generation, tramsmission and distribution facilities needs to be managed and cordinated as a whole.

    • @realpars
      @realpars  2 ปีที่แล้ว +1

      Thanks for adding that, Julio!

  • @vannrodriguez5162
    @vannrodriguez5162 2 ปีที่แล้ว

    this video tutorial so pretty awesome... i understand very well

    • @realpars
      @realpars  2 ปีที่แล้ว

      Glad you liked it!

  • @_stardust__
    @_stardust__ 5 ปีที่แล้ว +7

    Such a useful channel. Love your work! Keep going. Animations & overall presentation of the video is superb.

    • @realpars
      @realpars  5 ปีที่แล้ว

      Hey Dipankar!
      Thanks a lot for your kind compliment! We are always extremely happy to hear such positive feedback! If you ever have any questions, feel free to reach out to us.
      Happy learning!

  • @abdelwahabkara8019
    @abdelwahabkara8019 5 ปีที่แล้ว +2

    The best channel!!!
    Thanks a million dear

    • @realpars
      @realpars  4 ปีที่แล้ว +1

      Great! Thanks a lot!

  • @steffenpo
    @steffenpo 4 ปีที่แล้ว +21

    Very good tutorial, unfortunately not all aspects of a DCS system are mentioned. An PLC system is likely used for a dedicated application where the DCS is more used for controlling a whole plant. In most of the plants they use both at the same time, connected together (SCADA, Hardwired, OPC, Modbus...). Where the DCS is on top of the PLS system. And if the installation was good they can still work independed in case the PLC or the DCS got a problem. Thats why most PLS even they are connected to a DCS have got an HMI panel.

    • @realpars
      @realpars  4 ปีที่แล้ว +2

      Thanks for your comment, and sharing your knowledge with us!

    • @_Iokanaan_Marusidze_
      @_Iokanaan_Marusidze_ ปีที่แล้ว +2

      Thanks 👍

  • @renatooviedopecho5828
    @renatooviedopecho5828 3 ปีที่แล้ว

    Friend, I really love you, you are the best explaining your videos

    • @realpars
      @realpars  3 ปีที่แล้ว

      Thanks for your support! :)

  • @eliosgreek8028
    @eliosgreek8028 5 ปีที่แล้ว +6

    It's a great video.
    please make video on power system automation.

    • @realpars
      @realpars  5 ปีที่แล้ว +1

      Hi Ellios,
      Thanks for your comment and your suggestion. I will pass this on to our course developers!
      Thanks for sharing and happy learning!

    • @Techwem
      @Techwem 3 ปีที่แล้ว

      For more videos related to DeltaV, Honeywell, Yokogawa or ABB DCS, Visit our Channel and Subscribe.

  • @zeealpal
    @zeealpal 4 ปีที่แล้ว +6

    Love your videos, very interesting.
    There are circumstances where the cost of a DCS software such as PCS7 will cost more than Step7/WinCC to perform the same tasks, (at Siemens) I was working on the data analytics side helping an integrator who had installed a brewery control system, the decision (by the integrator) to go with S7-1500 + ET200s was based on software cost rather than anything else. They did already have their own libraries to run this however.
    I believe that in TIA at least, PLC tags can easily be dragged across onto a HMI, and easily searched/selected if needed. No need to manually export and import the tag lists that is handled automatically.

    • @realpars
      @realpars  4 ปีที่แล้ว +2

      Thanks for sharing your knowledge and experience with us, we always appreciate that!

    • @sreeram5217
      @sreeram5217 4 ปีที่แล้ว

      Do xssvv

  • @soumitrabarman3638
    @soumitrabarman3638 5 ปีที่แล้ว +12

    Can you please tutorial Videos on safety elements like safety relay, safety contactor and different protection levels like protection level 3, 4 etc.

    • @realpars
      @realpars  5 ปีที่แล้ว +7

      Hey Soumitra!
      Thanks for your comment and your suggestion. I will pass this on to our course developers!
      Thanks for sharing and happy learning!

    • @subramanianpalaniappan9475
      @subramanianpalaniappan9475 3 ปีที่แล้ว

      @@realpars
      . 00000
      0
      0.000000000. 00000000000
      0000
      0
      0🔊
      📯👓0👓🔊👍👍👍👍👝👍👍👍👍🔊🔊🔊🔊🛍️🔊👍👍👍👍👓👍 🔊🔊🔊🔊👍👓🔊👍👍👍👓👓🔊👍👍🔊👍👍🔊🔊🔊👓📯🔊🔊👓👍👍🔊👓👓😊🎉🎉🎉👓👓😊🔔🔔📣📯🔔🔔📯🔔🔔📯👓👓

    • @kevintam3525
      @kevintam3525 3 ปีที่แล้ว +1

      No

  • @shahabuddinshaikh1274
    @shahabuddinshaikh1274 3 ปีที่แล้ว +1

    Thanks a lot Sir

    • @realpars
      @realpars  3 ปีที่แล้ว

      Most welcome!

  • @tinmyint1158
    @tinmyint1158 ปีที่แล้ว

    Love your videos, very interesting

    • @realpars
      @realpars  ปีที่แล้ว

      Glad you think so! Thank you for sharing

  • @adelabdul-aziz8066
    @adelabdul-aziz8066 3 ปีที่แล้ว +1

    Thank you

    • @realpars
      @realpars  3 ปีที่แล้ว

      You're very welcome!

  • @shivamRudram
    @shivamRudram 2 ปีที่แล้ว +1

    Can we describe SCADA as networked PLC's ? Where as the DCS being single or multiple controllers for entire plant

  • @obeydaalmuhaisen5863
    @obeydaalmuhaisen5863 5 ปีที่แล้ว +4

    Good illustration for both systems thank you

    • @realpars
      @realpars  5 ปีที่แล้ว

      Hi Obeyda,
      Happy to hear that! Thanks for sharing.

  • @rammilanthakur9363
    @rammilanthakur9363 4 ปีที่แล้ว +1

    Very good and supportable videos..
    Like it..👍👍

    • @realpars
      @realpars  4 ปีที่แล้ว

      Thank you!

  • @sakmee6808
    @sakmee6808 3 ปีที่แล้ว

    Thanks for your information.

    • @realpars
      @realpars  3 ปีที่แล้ว

      You're more than welcome!

  • @sherifeissa6709
    @sherifeissa6709 5 ปีที่แล้ว

    Great effort RealPars, best wishes to you

    • @realpars
      @realpars  5 ปีที่แล้ว

      Thanks a lot, Sherif!

  • @bourun790
    @bourun790 3 ปีที่แล้ว

    Thanksអគុណ👏

  • @ChaseMyles
    @ChaseMyles 5 ปีที่แล้ว +2

    You guys left out Omron! One software for both PLC and HMI, as well as global variables that when created in one pop up in the other. Super easy and quick for programming.

  • @sohailjanjua123
    @sohailjanjua123 3 ปีที่แล้ว

    Hi, I like your lecture. Thanks

    • @realpars
      @realpars  3 ปีที่แล้ว

      You are welcome!

  • @kunli275
    @kunli275 2 ปีที่แล้ว

    Thanks. Very good training tutorial. Can I ask do we have comparison between IoT and Scada?

    • @realpars
      @realpars  2 ปีที่แล้ว +2

      Thanks for your kind comment! That would make for a great topic suggestion. I will be happy to pass this on to our team for a possible future video course.

  • @WansHD
    @WansHD 5 ปีที่แล้ว +5

    Maybe there is another parameter that missing, how about data acquisition at SCADA and DCS? This is really important, but i hope you could make another video about this :)

    • @realpars
      @realpars  5 ปีที่แล้ว +2

      Hey!
      Thanks for your feedback! I will definitely forward this to our creator team, hopefully they can create a course video about that.
      Thanks for sharing and happy learning!

    • @ericramey6503
      @ericramey6503 3 ปีที่แล้ว

      No you don't.

  • @mahmoudhossamel-deen2559
    @mahmoudhossamel-deen2559 3 ปีที่แล้ว

    Very good, Thank you.

    • @realpars
      @realpars  3 ปีที่แล้ว

      Our pleasure!

  • @filimniko
    @filimniko 5 ปีที่แล้ว +2

    Great Thanks for Your Job!

    • @realpars
      @realpars  5 ปีที่แล้ว

      Thanks for your support, Nikolai!

  • @ramzyaboudaya3484
    @ramzyaboudaya3484 ปีที่แล้ว +1

    Thanks for sharing, but as far as I know dcs have a faster processing time than scada due to its use in real time fast processes but here you said scada has faster processing times. Can you elaborate please.

    • @realpars
      @realpars  ปีที่แล้ว

      This was the case in the early 2000s, but with the introduction of bigger and faster processors, there is little difference in speed between DCS, PLC, and the supervisory SCADA systems. In reality speeds of processors are faster than the requirements for data updates. Most DCS systems update values from 4 to 10 times per second. This is on par with modern SCADA systems, so the differences are less pronounced than 10 - 15 years ago.

  • @hanhkhong2468
    @hanhkhong2468 4 ปีที่แล้ว +2

    Hello RealPars,
    Can you please elaborate why the DCS has more advantage in safety? What component or functionality of DCS make it more preferable?
    Thanks,

    • @realpars
      @realpars  4 ปีที่แล้ว +3

      Thanks for the topic suggestion, I will definitely go ahead and forward this to our creator team. Happy learning!

  • @kevinwikram1245
    @kevinwikram1245 ปีที่แล้ว

    great video thank you

    • @realpars
      @realpars  ปีที่แล้ว

      You're very welcome!

  • @laithjawad9208
    @laithjawad9208 3 ปีที่แล้ว

    Thanks- could you please gave some videos about Delta V

    • @realpars
      @realpars  3 ปีที่แล้ว +1

      Hi Laith!
      Thanks for your comment and your suggestion. I will pass this on to our course developers!
      Thanks for sharing and happy learning!

  • @sameersalem1827
    @sameersalem1827 5 ปีที่แล้ว +1

    Great work I really enjoyed it.

    • @realpars
      @realpars  5 ปีที่แล้ว

      Thanks for your support, Sameer!

    • @ericramey6503
      @ericramey6503 3 ปีที่แล้ว

      No you didnt.

  • @amilisgenderov6675
    @amilisgenderov6675 ปีที่แล้ว

    Just great 👍

    • @realpars
      @realpars  ปีที่แล้ว

      Thank you!

  • @seyiotuks8680
    @seyiotuks8680 4 ปีที่แล้ว +2

    I got a lead Engineer interview which asks me to have advanced knowledge of SCADA/DCS systems. What sort of questions might they ask me that would trip me up?

    • @Techwem
      @Techwem 3 ปีที่แล้ว

      For more videos related to DeltaV, Honeywell, Yokogawa or ABB DCS, Visit our Channel and Subscribe.

    • @elliot1784
      @elliot1784 7 หลายเดือนก่อน

      How’d it go?

  • @Logixcontrol
    @Logixcontrol 3 หลายเดือนก่อน

    Need more substation RTU programming, possibly GE-D20 conversion to Novatech LX+.

  • @sadarksoul
    @sadarksoul 3 ปีที่แล้ว +5

    SCADA is centralized and DCS is distributed, one of the main things in the video is wrong 😑
    SCADA systems are highly distributed systems used to control geographically dispersed assets, often scattered over thousands of square kilometers, where centralized data acquisition and control are critical to system operation. They are used in distribution systems such as water distribution and wastewater collection systems, oil and natural gas pipelines, electrical power grids, and railway transportation systems. A SCADA control center performs centralized monitoring and control for field sites over long- distance communications networks, including monitoring alarms and processing status data. Based on information received from remote stations, automated or operator-driven supervisory commands can be pushed to remote station control devices, which are often referred to as field devices. Field devices control local operations such as opening and closing valves and breakers, collecting data from sensor systems, and monitoring the local environment for alarm conditions.
    DCS are used to control industrial processes such as electric power generation, oil refineries, water and wastewater treatment, and chemical, food, and automotive production. DCS are integrated as a control architecture containing a supervisory level of control overseeing multiple, integrated sub-systems that are responsible for controlling the details of a localized process. Product and process control are usually achieved by deploying feed back or feed forward control loops whereby key product and/or process conditions are automatically maintained around a desired set point. To accomplish the desired product and/or process tolerance around a specified set point, specific PLCs are employed in the field and proportional, integral, and/or derivative settings on the PLC are tuned to provide the desired tolerance as well as the rate of self-correction during process upsets. DCS are used extensively in process-based industries.

    • @realpars
      @realpars  3 ปีที่แล้ว +5

      Thank you for your comments. The point about distributed components was made clear from 1:00 to 1:30 in the video and SCADA clearly is designed to operate across multiple locations. To be honest, the terms SCADA DCS are becoming "worn", as many hybrid systems have com onto the market that look and act a little like each type of system. Originally, the "D" in DCS, or distributed, referred to the separation of I/O and controller hardware within the same local system. Per the "classic" definition, the video is correct. Both types of systems are becoming closer in function, as explained in the video, and also in hardware. The true differences lie in two areas: DCS systems still have more of a reliance on a single vendor for hardware, and DCS systems tend to be configured from common component libraries and tag databases that are shared among components in the system.

    • @sadarksoul
      @sadarksoul 3 ปีที่แล้ว

      @@realpars thanks for replying

  • @johanburger4454
    @johanburger4454 2 ปีที่แล้ว

    Can HMIs still be utilised in a DCS system? This graphical interface that is mentioned that is integrated into the system, does it contain HMIs or is it similar hardware with touch screen capabilities?

    • @realpars
      @realpars  2 ปีที่แล้ว +2

      HMI, referring to the terminal used to display operator graphics, is used in DCS, SCADA, PLC, and hybrid systems. For DCS systems, the software used to generate screens and execute them is typically integrated into the DCS system, and likely is part of a single software suite. For the other systems, the HMI configuration and server applications may be stand-alone, with communication connections to the controllers to access process data.

    • @johanburger4454
      @johanburger4454 2 ปีที่แล้ว

      @@realpars perfect! thanks for the that👌

  • @tonyz6672
    @tonyz6672 3 ปีที่แล้ว

    thank you!

    • @realpars
      @realpars  3 ปีที่แล้ว

      You're welcome!

  • @MD-cd7em
    @MD-cd7em 5 ปีที่แล้ว +1

    THANKYOU

    • @realpars
      @realpars  5 ปีที่แล้ว

      You are very welcome!

  • @kevinblacksmith2705
    @kevinblacksmith2705 4 ปีที่แล้ว

    By subscribing to your courses would there be an HMI programming course available to me?

    • @realpars
      @realpars  4 ปีที่แล้ว

      Hi Kevin,
      Thanks for your comment!
      Sure, you will obtain full access to our complete course library (400+ video courses) by subscribing to either our monthly package for €22.12 a month or our yearly package for €159.28
      We currently have the following video courses covering HMI, feel free to check them out learn.realpars.com/search?q=hmi
      I hope this helps- please let me know if you have any other questions, and I'll do my best to assist.

    • @kevinblacksmith2705
      @kevinblacksmith2705 4 ปีที่แล้ว +1

      @@realpars Thank you for your reply, will you have some courses on the systems other than Siemens such as Allen Bradley, Emerson, GE, or Schnider?

    • @Techwem
      @Techwem 3 ปีที่แล้ว

      For more videos related to DeltaV, Honeywell, Yokogawa or ABB DCS, Visit our Channel and Subscribe.

  • @maliklao8917
    @maliklao8917 3 ปีที่แล้ว

    what is the differences between wincc flexible scada and pcs7

    • @realpars
      @realpars  3 ปีที่แล้ว

      Hi Malik,
      Great question! This would actually make for a very good video course. I will pass this on to our course developers as a topic suggestion for a future video course.
      Thanks for sharing!

    • @tennisgigi1626
      @tennisgigi1626 2 ปีที่แล้ว

      In my opinion wincc flexible is not a real Scada, not all functions and features present in Wincc 7.x are on board. I don't suggest Flexible for large number of tag or plants.

  • @yahyamazlomyar7099
    @yahyamazlomyar7099 3 ปีที่แล้ว

    same always great videoes

    • @realpars
      @realpars  3 ปีที่แล้ว

      That's amazing! Thanks for your positive feedback!

  • @MrSidra2009
    @MrSidra2009 2 หลายเดือนก่อน

    Awesome

    • @realpars
      @realpars  2 หลายเดือนก่อน

      Thanks!

  • @Jin-iq6gg
    @Jin-iq6gg 4 ปีที่แล้ว

    may I ask for an explanation of the "W@de RTU w320e" working system for running a 3 phase electric motor

    • @realpars
      @realpars  4 ปีที่แล้ว

      Hi Arief!
      Thanks for your comment and your suggestion. I will pass this on to our course developers!
      Thanks for sharing and happy learning!

  • @arafatrahman4476
    @arafatrahman4476 4 ปีที่แล้ว

    Hi Realpars
    Great the video to learn about DCS and ASCDA.
    Can you please help to get wincc software.

    • @realpars
      @realpars  4 ปีที่แล้ว

      Thanks for your support, Arafat!
      Yes, we sell a variety of software, including WinCC software over at our online store bit.ly/2WJOxd3
      Feel free to reach out to us over at hello@realpars.com, if you have any questions.

  • @mohdaqib2978
    @mohdaqib2978 3 ปีที่แล้ว +2

    If in a interview it is asked what is the difference between SCADA and DCS what i should answer as they look almost same from this video..😅

    • @joshuajavier5158
      @joshuajavier5158 2 ปีที่แล้ว

      Do you know the answer already it is confusing actually..

  • @farabielec
    @farabielec 5 ปีที่แล้ว

    Thanks 👍

    • @realpars
      @realpars  5 ปีที่แล้ว

      You are very welcome!

  • @001prk
    @001prk 5 ปีที่แล้ว +1

    HI
    Can you throw some light on Ground Protection System

    • @realpars
      @realpars  5 ปีที่แล้ว

      Hi Prakash,
      Thanks for the topic suggestion, I will make sure to forward this to our creator team.
      Thanks for sharing and happy learning!

    • @001prk
      @001prk 5 ปีที่แล้ว

      @@realpars Hi thanks for your reply. At the outset i would like to thanks you for videos, as coming from Mechanical Engineering your videos are very well designed for basic understanding and as I have to look the control part of Marine Machinery. So, thanks and keep uploading

  • @ezenwadiwe7514
    @ezenwadiwe7514 5 ปีที่แล้ว

    Good job

    • @realpars
      @realpars  5 ปีที่แล้ว

      Thank you, Eze! Happy learning!

  • @fajarrukmo
    @fajarrukmo 3 ปีที่แล้ว +1

    when you say nowadays PLC and DCS become similiar, why big company still release PLC and DCS Separately. Like S7 1500 and PCS7
    would be great if you make video about that.

    • @realpars
      @realpars  3 ปีที่แล้ว +1

      Hi Fajar!
      Thanks for your comment and that is indeed a great topic suggestion. I will happily pass this on to our course developers!
      Thanks for sharing and happy learning!

  • @automationpk6720
    @automationpk6720 5 ปีที่แล้ว

    You must add Mitsubishi

  • @gene_Code
    @gene_Code 2 ปีที่แล้ว

    Seems the same to me. 🤷
    Also scada has Secure Auth protocols these days and SIL ratings.

  • @APatriarch
    @APatriarch 8 หลายเดือนก่อน

    Let me save you a video. DCS is one OEM products. SCADA system, is many OEM products that need scada s/w to synchronise them.

  • @trentbergen7100
    @trentbergen7100 ปีที่แล้ว

    After 15 years in control systems. Odysseus has no safer than SIL 3 rated PLC. In fact with the lag time of a DCS I would say it's less safe.

  • @sidraali5159
    @sidraali5159 5 ปีที่แล้ว +1

    is DCS programming the same as PLC programming?

    • @realpars
      @realpars  5 ปีที่แล้ว +4

      No. DCS systems are partially configured and partially "programmed". The tags, I/O, loops and alarms are typically all configured using wizards, tables, and menus. Device and control loop logic is typically provided as pre-configured internal blocks where the "programmer" simply makes connections between the tag table and these blocks. In PLC programming, more choices are available for creating logic, such as ladder logic, structured text and function blocks. While there are many items like tag tables that are configured much the same as in a DCS, there is more "programming" effort in the PLC environment, but there is somewhat more flexibility as well compared to a DCS. DCS systems are more efficient for process that are heavy in analog inputs and outputs. PLC systems are more efficient for process that are heavy in digital inputs and outputs.

  • @kdgr
    @kdgr 3 ปีที่แล้ว

    👍

  • @Roslinification
    @Roslinification ปีที่แล้ว

    So basically.
    DCS = Apple
    SCADA = Android

  • @Vetiverv
    @Vetiverv 5 ปีที่แล้ว +1

    hi, you have forgotten, some dcs systems completely open to all forms of communication, but above all in a ring with intersected servers, with an intuitive man-machine interface, giving the company the possibility to remain active and productive 365 days a year, the ABB system six system and the new one, but not least the yokogawa system, with modular redundancies, which can take on parts of the ring out of use without causing the system to stop, keeping it ALWAYS efficient and above all PRODUCTIVE THE SITE, unlike an independent system without redundancy, like the SCADA

    • @realpars
      @realpars  5 ปีที่แล้ว +1

      Hi Marco,
      Thanks for sharing your knowledge with us. We appreciate that!

  • @_Iokanaan_Marusidze_
    @_Iokanaan_Marusidze_ ปีที่แล้ว

    Thanks 👍

    • @realpars
      @realpars  ปีที่แล้ว

      You're very welcome!

  • @ekkapanrattanazoot6079
    @ekkapanrattanazoot6079 ปีที่แล้ว

    Thanks!