If we get sprinkler sprinkler distance 10 ft . Than branch to branch distance come out to 225/10 = 22.5 . Is very high from branch sprinkle to other branch sprinkler.
As salam alaikum sir Sir ap videos ki ek list bane fire fighting ke liye jis mein ek fresher ko konsi video pahle dekhni hai phr uske baad konsi is tarike se take koi confusion na ho samjhne mein.
Sir as per NFPA 13 distance between two sprinklers is 14ft as per you But we are making fire sprinkler system for 34floor building we are keeping distance between two sprinkler is 3mtr less than 14ft Will you please explain what is right distance ?
Hello sir nice video very understanding one. But i have doubt please can you clear it. Remote area breadth= distance between branch + distance between branch and wall = 16+16+8+5.33 = 45.33 right . Why didn't take 8 sir . Thank you in advance
why did you 16 by 3, as 16 is length between two branches and 3 sprinkler are in with side(42' side) could we not calculate it by simple 8+16+16 as 8 is distance from wall and 16 between two branches. waiting for your response
Part-2 Fire Sprinkler Hydraulic Calculation in Light Hazard : th-cam.com/video/Y4TSjrKh14M/w-d-xo.html
Insha'Allah, I will make video
Best Chanel to gain design of fire protection system
Thanks
Alhamdollilah Tenweer Ahmad Bhai sb
Apke Vedio dekh kar bahut Knowledge Mila hai
Allah Apko hamesh khush rakhe/ shehatmand rahe
Thanks
Very informative videos, you made sir
Thank you.
Welcome
Very informative video jazakalla sir g
Thank you
God bless u
Thanks
You are great sir. i really so much respect you.
Alhamdullah
Easy understandable and very informative lecture sir.... Love from Nepal❤❤
Welcome
If we get sprinkler sprinkler distance 10 ft . Than branch to branch distance come out to 225/10 = 22.5 . Is very high from branch sprinkle to other branch sprinkler.
Follow as guided in video
SALAM HY GOOD VIDEO
W.Salam
thanks you tanveer bhai
Welcome
BAHUT ACHA BHAI
Thank you
Walikum salam sir from India 🇮🇳
Jazakallah
Please provide calculation and selection of jockey pump main pump and sprinkler pump
This calculation excel sheet is attached in this video description
Attached in description
Thank you sir..👍
Welcome
Nice video thank you bro..
Welcome
Nice Sir
Thanks
nice, lecture but for us not hindi or what language his using.. need to read sub. but informative. i appreciate it. Thank you for your knowledge
Thank you
As salam alaikum sir
Sir ap videos ki ek list bane fire fighting ke liye jis mein ek fresher ko konsi video pahle dekhni hai phr uske baad konsi is tarike se take koi confusion na ho samjhne mein.
Insha'Allah I will prepare
can u please tell me about the specific sections of NFPA 13 , i mean what sections should i need to studty in order to do hydraulic calculation
One chapter is given about designing
Sir as per NFPA 13 distance between two sprinklers is 14ft as per you
But we are making fire sprinkler system for 34floor building we are keeping distance between two sprinkler is 3mtr less than 14ft
Will you please explain what is right distance ?
Depends on designer
Sir plz tell me the Sara kuch to ap remote area Kay liay Niall rahay Hain to dosray areas Kay liay kaisay Karain gain
Other area will not calculate. Only remote calculate of different hazards.
One more doubt if actual hydraulic area exceeds the hydraulic area . Is that fine ?
Actual area is greater but design area shall be taken according to NFPA requirements
Thank you sir
Welcome
Convencing speed to high.
Ok
Hello sir nice video very understanding one. But i have doubt please can you clear it.
Remote area breadth= distance between branch + distance between branch and wall = 16+16+8+5.33 = 45.33 right . Why didn't take 8 sir . Thank you in advance
If not taken then add it
@@TanweerAhmed no sir . I m not telling your wrong or your mistaken . I m asking did you missed or should calculation as you did ? Thank you
mention timestamp then i will watch and update accordingly@@malsitechproject
Sir 14.35 to 16.45 time gap
Why all data given in FPS system please make video in MKS system.
You can convert yourself
That was easy to grasp... Can you please guide about In rack system sir?
Insha'Allah in future
Can we connect with storage tank and swimming pool parallel?
You can but as per NFPA requirements, water shall be reserved for firefighting always. Additional water will be connected
What is the main purpose of pressure/Air vessel in fire protection system ???
To absorb water hammering
64 pendent sprinkler on 1 floor or pump is down comer than what hp pump is required sir or how can we calculate this one.
Same pattern is designed
Please share pump design calculation for sprinkler and hydrant system seperately
Ok
Please use International units
Ok boss
why did you 16 by 3, as 16 is length between two branches and 3 sprinkler are in with side(42' side) could we not calculate it by simple 8+16+16 as 8 is distance from wall and 16 between two branches. waiting for your response
If you think something is wrong in calculation then do it correct. I want to clear concept of calculation.
Can you post your videos on fire fighting in English?
My all videos are in Urdu, I am subtitling videos in English
Telegram link not working sir
Ok let me check
sir Drawing Wrong H . Ya To calculation Wrong H
Wrong H
BRACH CALCULATION
DEKHIYE 8+16+16+16+8=64 Hota h
AAP Ne bata diya drawing m 56 ye Kaise???
Let me check
I have rechecked.There is no mistake or wrong. @@AUTOCADWALA_07