WEG CFW300 VFD 3-Wire Control with Forward and Reverse Tutorial at AutomationDirect
ฝัง
- เผยแพร่เมื่อ 27 มี.ค. 2019
- www.automationdirect.com/weg-... - (VID-DR-0093)
- Learn the three steps needed to add forward and reverse control to your 3-wire variable frequency drive controls for your WEG CFW series drive. This is the best VFD, with a super low cost, but with high end features like Dynamic Braking, Fire Mode, PID, 65,000A SCCR, Zero Stack footprint, Multi-Speed, etc., and is even cULus listed!
You can download the software for free at www.automationdirect.com/adc/...
To learn more visit www.automationdirect.com/weg-...
Check out all of our videos at www.automationdirect.com/vide...
To SUBSCRIBE: th-cam.com/users/automati...
Facebook: / automationdirect
Twitter: / automationdirec
LinkedIn: / automationdirect
**Prices were valid at the time the video was released and are subject to change.
Related AutomationDirect.com part numbers: CFW300A01P6S1NB20, CFW300A02P6S1NB20, CFW300A04P2S1NB20, CFW300A06P0S1NB20, CFW300A01P6S2NB20, CFW300A02P6S2NB20, CFW300A04P2S2NB20, CFW300A06P0S2NB20, CFW300A07P3S2NB20, CFW300A01P6T2NB20, CFW300A02P6T2NB20, CFW300A04P2T2NB20, CFW300A06P0T2NB20, CFW300A07P3T2NB20, CFW300B10P0B2DB20, CFW300B15P2T2DB20, CFW300-CRS232, CFW300-CRS485, CFW300-CUSB, CFW300-KHMIR, CFW100-CFW300-MMF, CFW300-IODR, CFW300-IOAR, CFW300-IOADR, CFW300-IOAENC, CFW300-KFA-S1-S2, CFW300-KFB-S2, CFW-WPS, CFW300-FAN-A, CFW300-FAN-B, CFW100A01P6S120G2, CFW100B02P6S120G2, CFW100A01P6S220G2 ,CFW100B02P6S220G2, CFW100C04P2S220G2 - วิทยาศาสตร์และเทคโนโลยี
Perfect explanation of how to wire a this specific vfd so unless you have this make and model don’t waste your time watching.
Thanks George. Yes this video series is specifically for the WEG family of VFDs, but the general idea should be transferable to any VFD.
Thankអរគុណ
Thanks! Make sure to check out more of our videos at www.automationdirect.com/videos/home
is it possible to control a motor with a 3 position switch? Position 1 would be forward, position 2 would be stop, and position 3 would be reverse
Yep ...Check out this video: th-cam.com/video/lE8EA7NzQDM/w-d-xo.html
I want to run my forward reverse in between 2 limit switches, is this possible? Could you please assist with wiring diagram
Hi Quintin, You want to run forward and have it automatically cut off when it hits the forward limit and reverse until it hits it's limit - correct? If so, you want this video: th-cam.com/video/lE8EA7NzQDM/w-d-xo.html and simply put N.C. Limit Switches inline with the two switches.
RED push bottom is NORMALLY CLOSED OR NORMALLY OPEN.???