Wago's vs. Wire Nuts - How To Wire Outlets During Rough In

แชร์
ฝัง
  • เผยแพร่เมื่อ 23 ก.ค. 2024
  • *$25 OFF the Sense Home Energy Monitor for Subscribers using code BENJAMIN!
    *
    CLICK HERE: store.sense.com/discount/BENJAMIN
    My Favorite Tool: amzn.to/3NIFJuO
    Wago Push Style Wall-Nuts: amzn.to/2Ph81kV
    Wago Lever-Nuts: amzn.to/2qQozHe
    Traditional Wire Twist Connector Nuts: amzn.to/2EdNDec
    Tools I Recommend: www.amazon.com/shop/benjamins...
    In this video we are wiring general purpose receptacles in a "daisy chain" using the pigtail method.
    In the first box we use Wago Wall-Nuts or "push in connectors" and in the second one we use traditional twist style wire nuts. What do you think of the two methods?
    Thanks for watching and subscribing! As an Amazon affiliate I earn from qualifying purchases. Thank you for your support!
    0:00 - Wago's Vs. Wire Nuts Intro
    0:08 - The Cable Run
    1:12 - How To Strip The Electrical Wires
    2:06 - Wire Connectors We Will Be Using
    2:16 - Wago Push-Style Connectors
    7:01 - Traditional Wire Nuts
    8:41 - Why They Are Called Wago's
    9:09 - Electrical Wiring Notes
    10:45 - SUBSCRIBE!!!
    Blessings from Minnesota,
    Ben

ความคิดเห็น • 1.4K

  • @ajfarms630
    @ajfarms630 4 ปีที่แล้ว +12

    Boy I have got to say you are Neat, Clean. I'm proud of you. I watched you install a breaker box and you inspired me to go back and clean up my own breaker box. I'm sure glad I did it causes you to have a little more pride in your work!

  • @jacobplank
    @jacobplank 3 ปีที่แล้ว +3

    A great informative videos especially for beginners and myself, (close to 4 years as an electrician). We don't ever pig tail If it's just 2 sets of wires, but also we never do prepping until we come back to trim out, of course it would save time in the end to do it while roughing in. Great video keep it up 👍

  • @BenjaminSahlstrom
    @BenjaminSahlstrom  4 ปีที่แล้ว +3

    *$25 OFF the Sense Home Energy Monitor for Subscribers!*
    CLICK HERE: sense.refr.cc/bensahlstrom
    Here are some hand tools that I highly recommend: www.amazon.com/shop/benjaminsahlstrom
    Really appreciate all of your comments and the discussion here! Let me know what thoughts you have! If you use one of tha above links it will also help support the channel at NO cost to you. I wouldn't be able to do this without you guys.
    Blessings,
    Ben

  • @KienTran
    @KienTran 4 ปีที่แล้ว +29

    Recently discovered the lever Wagos and it’s a life changer as I’ve been replacing all my switches and outlets with decora style ones! It’s so much simpler!

    • @RoastedHVAC
      @RoastedHVAC 4 ปีที่แล้ว +2

      Yes! Love the levers...

  • @normhodgkinson6965
    @normhodgkinson6965 4 ปีที่แล้ว +10

    Nice job with the wiring, and nice job with the tutorial. Been using Wago's for last couple years, and once in awhile wire nuts when necessary.

    • @buzzincalifornia
      @buzzincalifornia 3 ปีที่แล้ว

      I only use wire nuts when I’m working in older women’s homes, older women don’t understand wagos, but they do understand twisting nuts

  • @tompeters4234
    @tompeters4234 4 ปีที่แล้ว +9

    This is a great video once again. I'm catching up on ones I've missed. I appreciate the detailed explanations and still make it easy to watch. You're explanations and reasoning are usually aligned with my views and you cover a lot of the little details (like showing the run from breaker, through hole, wire staples etc).
    I bought some knock-off Wago Lever Nuts. Haven't used the lever nuts yet, but the push style is kinda intriguing. I never looked into them to see they were removable (and so easy it seems unless that was a cut scene). I got the Lever Nuts for a quick temp project//test bench to test a motor or temp wiring lighting (of course not to code).
    Problem is I don't do a ton of electrical so I have a supply of wire nuts to last a lifetime for me. Maybe I should donate my little pile of old style winged wire nuts to you LOL.

    • @kooale
      @kooale 4 ปีที่แล้ว +2

      Maybe u should read all the comments herein by other electricians b4 u do that

  • @robertlane6675
    @robertlane6675 4 ปีที่แล้ว +5

    I use the lever Wago's for low voltage wiring. Derail circuits for ski hill chairlifts often have 24awg solid and 14 or 12 awg stranded wire connections. Lever Wagos work much better for fault isolation because they allow you to open and close the splice cleanly in addition to easily adding or removing a single wire for testing.

  • @marksandlin8376
    @marksandlin8376 4 ปีที่แล้ว +3

    I like the lever locks for temporary connections. I sometimes have to connect up transformers for load testing and high potting, lever locks are great. They also work will if you are using solid and stranded wire together. They also make great cap offs for roughed in electrical boxes. The push in ones are great when reworking an old installation with not enough room to strip extra wire for a pretwist. It makes it super easy to make sure each wire is in all of the way.
    I do agree with never stabbing a receptacle or switch and it seems like the industry is moving away from that to the screw clamp method in the newer hardware. I've used a lot of Hubbell connectors and that seems to work.

  • @amrosla67
    @amrosla67 4 ปีที่แล้ว +6

    Thanks for a great video Benjamin!!!
    I like how professional your work ethic is and the pride you take in editing your videos!!!
    Have a safe and happy holiday season!!!
    Art
    PS: unless you have a video already published, can you make a video on hooking up a new 200amp service in a house or shop???

  • @anthonymitchell6831
    @anthonymitchell6831 4 ปีที่แล้ว +327

    good habit is to point wagos and wirenuts up to keep mosture from settling in outdoor boxes. I know your indoors but it becomes habit if you always point them up.

    • @Ed-uu9eo
      @Ed-uu9eo 4 ปีที่แล้ว +21

      That's how i was taught as well. I always have my wire nuts facing up.

    • @johnhanes5021
      @johnhanes5021 4 ปีที่แล้ว +6

      Yes, especially with low voltage control wiring. Condensation can settle in the down facing wirenut and corrode the connection.

    • @amastri1
      @amastri1 4 ปีที่แล้ว +9

      also cant fall up as in they cant fall off of they r pointed up

    • @steveblauvelt6312
      @steveblauvelt6312 4 ปีที่แล้ว +10

      @@amastri1 That is my reason for pointing up, never thoght about the moisture. Now I have 2 reasons.

    • @poursergio
      @poursergio 4 ปีที่แล้ว +5

      Just logged in because of this comment: I was hoping to read someone's comment about this. YES, if you are experienced enough, you should always push your wires in the box with the connectors UPWARDS. Now THAT's a real electrician. Learn there Benji

  • @jrmcd322
    @jrmcd322 4 ปีที่แล้ว

    Love the electrical videos. I have recently just finished a complete rewire of my two story 1870s home. I had initially decided to use wire nuts, but discovered the Wago Lever-Nut. The Wago is quick and simple. Plus if you have bad wrists, like I do, they are a big help. I did use wire nuts and pre-twist the wires under the house just because I have just started using the Wagos and had a little reservation about how they may hold up here in humidity of South Carolina since it is just a crawl space and not a climate controlled basement.

    • @davidetcheverry944
      @davidetcheverry944 4 ปีที่แล้ว

      I use a drill attachment to twist the nuts Jacob.

  • @davidyuko5142
    @davidyuko5142 4 ปีที่แล้ว +21

    Great comments down here Ben, looks to me like your efforts to build community and conversation are working... Keep up the good work.

    • @BenjaminSahlstrom
      @BenjaminSahlstrom  4 ปีที่แล้ว +5

      Yeah I really enjoy the comments for the most part! It's fun learning from people who have significant experience & knowledge.

  • @Cheva-Pate
    @Cheva-Pate 4 ปีที่แล้ว +13

    I have used Wago’s reuseble with a opener 2, 3 and 5 for like 10 years, never had any problem! I work with refridgeration/ heatpumps, i think they are great!

    • @brianreinhardt4050
      @brianreinhardt4050 4 ปีที่แล้ว +1

      th-cam.com/video/2uYD8e7idnY/w-d-xo.html

    • @B5Blue1968
      @B5Blue1968 4 ปีที่แล้ว

      @@brianreinhardt4050 The pinch ones i agree are not worth a damn. But this style Wago work great and are reusable. www.amazon.com/Wago-221-413-LEVER-NUTS-Conductor-Connectors/dp/B077WZV3D4/ref=sr_1_6?crid=DNL0365UX9DQ&dchild=1&keywords=wago+lever+nut&qid=1590717478&s=hi&sprefix=wago%2Ctools%2C171&sr=1-6

    • @curtisbme
      @curtisbme 4 ปีที่แล้ว

      @@brianreinhardt4050 Are you trying to show this as a proof point that Wago connectors aren't good?!? Aside from the fact that he was talking about the lever nuts, where aren't used here, the WAGO here didn't fail until after the entire wire was essentially on fire. That is absurd to try to draw any conclusion that any connection type is the problem here other than your house will burn down before you connection fails if somehow all the other safety measures had failed.
      If anything, I would want my connection to fail in an electrical box long before the wire got hot enough to melt the sheathing of the wire running though the wall but that doesn't happen with any of these.

    • @brianreinhardt4050
      @brianreinhardt4050 4 ปีที่แล้ว +1

      @@curtisbme I was just providing proof positive that there should be no question regarding amperage overages and burning/igniting. I've got no problem with them...

    • @ttiwkram
      @ttiwkram 3 ปีที่แล้ว

      You've been lucky so far.

  • @paulblais6796
    @paulblais6796 4 ปีที่แล้ว +4

    Great video here. Thanks for doing such nice and clean work. I have two suggestions...
    1- I think striping off the romex before going into the box is a bit faster and causes less damage to the coductors. I have seen some guys scratch enough of the conductor to cause a hot spot in the wire.
    2- Rolling wires into the box leaves you open to more damage potential from the drywallers. I always fold the wires into the box for two reasons. The first is that if the drywallers do actually hit the wires, then the damages is limited to the first two inches of the wire instead of the first four inches of the wires. The second is that the wire will already have the shape memory when installing the device.
    Regardless, your work looks great! I'd be proud to have you as an employee in my company.

  • @thepressedpig5397
    @thepressedpig5397 4 ปีที่แล้ว +2

    I used these for my rough in as a beginner it made it really easy!

  • @Robert-jt6eo
    @Robert-jt6eo 4 ปีที่แล้ว +2

    Very very informative and easy to follow. I will be waiting for whatever you post next.

  • @bourneelectricalable
    @bourneelectricalable 4 ปีที่แล้ว +40

    In the UK I've been using wago connectors and different variations (ideal and hellermann tyton) for 10 years. We used to have wire nuts under the brand screwit. I will not use any other form of connection now other than these mechanically maintainance free types. As for carrying full load current there is a video by a man called john ward where he carries out destructive testing and they are a lot more robust than everyone is saying. The single pinch point of the connector is a thing however on the opposite side of conductor the spring is pushing it onto a large flat conductive plate and so contact csa is not hindered. However not every one likes change and I cannot say there aren't those in the UK who are simply stuck in their ways and don't like progression.

    • @brianreinhardt4050
      @brianreinhardt4050 4 ปีที่แล้ว

      th-cam.com/video/2uYD8e7idnY/w-d-xo.html

    • @13ryanheartbreaker27
      @13ryanheartbreaker27 4 ปีที่แล้ว

      You can keep the “Change.” With your progressive cents talking bout points and tips, let’s just terminate every wire with terminal, distribution, junction blocks/strips. With compression fittings 😎 sorry I’m stupid when I drink.

  • @robinj1052
    @robinj1052 4 ปีที่แล้ว +6

    I use the Wagos with levers on low voltage systems (24VDC) and they are ideal. Have them in use on several offshore locations (non-ATEX) and have not had a single failure. In particular very useful in junction boxes where signal wires are connected: just use a Wago with more slots than wires and you always have an access point to get access to with the probe of the multimeter.

    • @broccoliman2293
      @broccoliman2293 2 ปีที่แล้ว

      Why not use them on (110-240). They are rated for those voltages and i use them on 230.

    • @robinj1052
      @robinj1052 2 ปีที่แล้ว

      @@broccoliman2293 I only work with 12/24VDC systems

    • @broccoliman2293
      @broccoliman2293 2 ปีที่แล้ว

      @@robinj1052 Oh ok. my bad

  • @666mrgene
    @666mrgene 3 ปีที่แล้ว +1

    Have been converted to using Ideal Insure type connectors for a couple of years now. Way to Go !!

  • @mattharding586
    @mattharding586 4 ปีที่แล้ว +2

    One thing that may make life easier, strip the sheathing before putting the wire into the box. It just makes it so you don’t have to reach in the tight box. I usually pull the wire next to the box, Mark it with my thumb and give an extra inch of seething or so inside the box. Just a tip. I’ve definitely forgot that step and done it they way you’ve done! I like watching your videos, your very clean and thorough

  • @donkmeister
    @donkmeister 4 ปีที่แล้ว +8

    Wagos are awesome. I discovered them rewiring my house about 12 years back and never use anything else. I didn't see you mention this in your video, but if you look on the non-cable entry side of the connector, you'll see a small hole/slot. This is so you can insert a probe when testing. Wagos are about the only electrical thing I can think of that is basically ubiquitous around the world... You won't find US cable in Europe, or British plugs in America, but you will find Wagos in all three.

    • @RadioRich100
      @RadioRich100 ปีที่แล้ว

      You will also find corruption in all 3 whats your point? They are still just a shortcut and not the best method. They are popular in foreign countries because of convenience only.

  • @danstheman33
    @danstheman33 3 ปีที่แล้ว +3

    You can use green grounding nuts to simplify your process, use less wire, and take up less space in the box. They're like regular wire nuts except they have a hole in the end- You leave one of the bare grounding wires long and push it through the hole, than twist it along with the other wires. That long wire coming out is your pigtail, no need for a separate one.
    Also, an automatic wire stripper is much faster, easier, safer and more consistent. It strips both the romex sheath and individual conductors, and with an easily adjustable strip length. I use an Irwin one and it's awesome.

    • @benjamintorres9211
      @benjamintorres9211 ปีที่แล้ว

      Green wirenuts are a nightmare to work on afterwards especially if the idiot before hand cuts off the twisted wires all the way to the back of the box

  • @richardbedard1245
    @richardbedard1245 3 ปีที่แล้ว +2

    When I wired my shop I used wire nuts because that's all I knew about. I'm going to find these wagos when I wire my cabin. Thank you!

    • @jonanderson5142
      @jonanderson5142 3 ปีที่แล้ว

      Don't stick to wire nuts..

    • @Nate-ud2yt
      @Nate-ud2yt 3 ปีที่แล้ว

      Ah. I get it. you want your cabin to burn down in 10 years so you can use the insurance money.

    • @wizard3z868
      @wizard3z868 3 ปีที่แล้ว +1

      spend the extra money and get the lever ones easy to remove better hold i think

  • @carolinewells4355
    @carolinewells4355 ปีที่แล้ว

    thank you so much for this, it is the first video that showed me how to pigtail or Wego the three sets of wires in 1 box.

  • @91156
    @91156 4 ปีที่แล้ว +13

    Wago type connectors is about all they use in Europe. Most over there don’t even know what a wire nut is.

    • @verlicht
      @verlicht 3 ปีที่แล้ว +1

      Certainly not true. Even the young sparkies get taught to use wire nuts in school.

    • @alexanderm.3644
      @alexanderm.3644 3 ปีที่แล้ว +1

      @@verlicht and they are also taught what it is by definition: crap!
      Wire nuts were widely used in the 60s as a fast alternative to screw type connectors. Especially if a house was not painted for some time you could see destinctive black discoloration above many connector boxes. Using this stuff today is pretty dare devil for a market that builds most of its homes from wood.

  • @Lorddarthvader1701
    @Lorddarthvader1701 4 ปีที่แล้ว +8

    New sub, I have used the Wago's myself in my new shop. I have had no problems with them. Yes I have looked at them after 6 months of table saw and other tool usage in my shop. No signs of issues. I used the lever type by the way. Just MHO...Now some of my outlets like the 240 and possible multiple draw outlets I used wire nuts....

    • @brianreinhardt4050
      @brianreinhardt4050 4 ปีที่แล้ว +1

      th-cam.com/video/2uYD8e7idnY/w-d-xo.html

    • @daveb5540
      @daveb5540 3 ปีที่แล้ว

      The lever kind have much more surface contact than the push type. I believe the lever ones are rated for 20 Amps, push type 15 Amps

  • @AMentorway4u
    @AMentorway4u 4 ปีที่แล้ว +1

    Wow. Thank GOD I love watching what you work on. Never new those wagos existed before. Pays to be a sub to your channel. Thanks for sharing your knowledge. Great work.

    • @dontblameme6328
      @dontblameme6328 3 ปีที่แล้ว +2

      Careful what you trust. Several bad techniques here... The biggest being the use of push connectors out of pure laziness.

    • @buzzincalifornia
      @buzzincalifornia 3 ปีที่แล้ว

      Jay, I bet that’s what your dad said when wire nuts came out and wires didn’t have to be soldered....LOL just kidding.

  • @keithratliff2347
    @keithratliff2347 2 ปีที่แล้ว

    I have been electrician for 35 years I am always learning something new when I watch Ben videos

  • @samuelt2072
    @samuelt2072 4 ปีที่แล้ว +5

    I'm not a electrician ( "technician" - wire puller) but have been using Wagos for years with no problem. They've been used for years in Europe and they don't seem to have an excess of related problems (ie, fires, arcing, etc)
    Like anything there is a bit of a learning curve with them (wire properly stripped & inserted fully).

    • @hugh007
      @hugh007 4 ปีที่แล้ว +5

      240 volt appliances likely use about half the current as we do in North America, watt for watt. Possibly the WAGOs last longer there.

    • @samuelt2072
      @samuelt2072 4 ปีที่แล้ว

      @@hugh007
      A possibility

    • @arnewemken6416
      @arnewemken6416 3 ปีที่แล้ว +2

      @@hugh007 We have also curcit with up 32A or more in Workshops . Deppendent on the type of the wago it goes up to 40A. So no problem with by high current with 500VAC. Normal rate is 10A to 16A in an house for a curcit in Germany. Very much but it is possible.
      Also normal Terminal Block from Wago or Phonix Contact are with Push In. We use them in industrie facilaties with up to 64A.
      If you are not sure, look in the Datasheet. Als product in Germany for electrical equipment must be prove on VDE or EN standards. If they write wromg limits on the datasheet, they will get trouble as VW 😬 with exhaust.

    • @professorg8383
      @professorg8383 ปีที่แล้ว

      @@hugh007 That is indeed why there have been failure of these in the US and not in Europe. The spring clamp type connector (Wagos have the highest resistance of of all the typical connection types, (wire nuts, screw terminals and crimps. Doing voltage drop testing at 20 amps I've seen 4 or more times the resistance of a wire nut.
      Where this because more significant is with higher currents, when current doubles the heating goes up by 4 times because it's "I^2 X R", ""I squared R".
      At 20 amps, the heat dissipated in that connection is about 1 watt. That doesn't seem like a lot, but because the contact area is so small, at that point, the heat becomes concentrated and significantly hot. The other type connections cover many times more surface area and they are much tighter than the little WAGO spring can make it.
      I've seen some test where the run 40 amps or more through them and the don't fail but get very hot. The trouble is a one time overload condition is unlike to fail catastrophically. Where the problem will arise is in repeated heat/cool cycles. That will anneal the spring, weakening it. I've done some repeated heat/cool cycles at a full 2o amps and the measured voltage drops again. The résistance goes up. More resistance means more heat.
      I think these things will work OK with low currents, but because of the "Current squared" factor they will begin to breakdown. If this happens in a box, you'll probably fail open and it probably is unlikely to cause a fire. I just think it's a bad idea to make a high resistance connection when we have ways that are much better. They are quick and easy, but I'd rather have the best connection I can make.

    • @professorg8383
      @professorg8383 ปีที่แล้ว

      @@arnewemken6416 The thing about that that isn't obvious is that you are talking about IEC or EN standards. The WAGO 221 says right on it 32 amps. But if you dig into the UL standards for use in North America, the rating is 20 amps. Also, the EN/IEC standards is at 85 C where as the UL standard is 105 C. The EN/IEC has them rated to 450 volts, but the UL standard calls for 600 volts.
      You have to dig into the weeds a bit to find these differences. WAGOs are UL listed for use in the US, however, not at the EN/EIC specs. The standards are not interchangeable. Of course our electrical systems are not interchangeable either. Even the way that the standards organizations work, are hugely different. Similar in some way, but way different in others. It's not apples to apples.
      I can just tell you this, I've spent many years in Industry and NEMA, (North American Manufactures Association), was the design spec guys. But in the last two decades or so, a lot of IEC stuff has made its way into industry. Bottom line is that you can build machines way cheaper using IEC specs than NEMA specs. The best way I can describe it is that the NEMA stuff is built far more beefy and robustly. For typical industrial control components, the NEMA stuff is twice the size or more than the IEC stuff. Prices for the same functional component is 3 to 5 times more than its IEC counterpart. Most NEMA stuff was designed to be repairable where as the IEC stuff is throwaway. Generally speaking, the NEMA stuff was designed with a much larger safety factor. where as the IEC stuff has little if any margin.
      To be completely honest, I hate the IEC stuff. And we have American companies making stuff to the IEC secs now too. Even though very little of it is actually made in the US. The IEC stuff is definitely more economical. I have seen much more catastrophic failure with IEC stuff. To the eye, it seems obvious that the IEC stuff is much more cheapy made. But the engineer side suggests that generally speaking our big industry has a much more robust power grid and short circuit fault currents are likely much higher too. That might explain why IEC that fails, seems to explode into pieces, where as the NEMA counterpart shows damage but can often be cleaned up and repaired and put back into service.

  • @jimdavis6833
    @jimdavis6833 4 ปีที่แล้ว +18

    When I did this kind of roughing in, I used a Romex stripper, not a utility knife. I found them to be safer and faster.

    • @hornetd
      @hornetd 4 ปีที่แล้ว +5

      Amen to that. Once they became available I would use jacket cutting pliers on the cable before inserting it into the box and then pull the jacket off after insertion. Before the pliers became available I used the cable rippers with the small cutting tooth inside a groove just wide enough for the cable. 12 Gauge cable on one side and 14 gauge cable on the other. The cutting tooth wasn't long enough to cut the wire insulation.

    • @jamesdavies686
      @jamesdavies686 3 ปีที่แล้ว +1

      I've always lightly scored the outer sheath until the last inch then I cut deeper, then I use the pulling motion to tear the wire inward. I always worried I'd scrape a conductor bare.

    • @13dart84
      @13dart84 3 ปีที่แล้ว

      i wish they made a romex stripper where 12-2 was on the very tip

    • @buzzincalifornia
      @buzzincalifornia 3 ปีที่แล้ว

      @@13dart84 Kline makes a 12,2 stripper, you use it the same as cutting wire, but the cutter only cuts the protective sheeting and not the wire insulation

    • @13dart84
      @13dart84 3 ปีที่แล้ว

      @@buzzincalifornia yeah I know I have one but the tip is the 14-2 and the more inside one is 12-2. Easier to un sheath the 14-2 because it’s on the tip

  • @Aepek
    @Aepek 4 ปีที่แล้ว +1

    Like using the WAGO 221-4xx & 221-6xx series lever nuts. Really does make wiring outlets, switches (boxes etc....) little faster & easier. The other nice thing is; able to energize the circuit & use the test points on the lever nuts to find any “issues” you may have...as doing “trouble shooting work” w/ these does make things go a little faster & easier, etc...👍🏻
    Let’s hope the WAGO Lever Nuts work well & the “compression fitting” can withstand the constant “power” being “turned” on/off over the years & last.....
    Do know one thing, even though they are a bit more expensive than the traditional wire nut....they sure are easier to work w/; & can make retrofits/remodels in older houses a lot easier to “wire up” when one doesn’t have a lot of “extra” wire coming from a box (ya know what I mean....LOL. Always a pain when take a plate off an outlet/switch & come to find out you have maybe 1-2 inches of wire to work with, not fun or easy😡, but using a WAGO really does come in handy at these moments👍🏻).
    Cheers✌🏼

  • @pattognozzi
    @pattognozzi 4 ปีที่แล้ว +1

    Great video! The Wago Lever Nuts are much better in my opinion than the push in type.

  • @andrewt9204
    @andrewt9204 4 ปีที่แล้ว +17

    When I use Wagos, I wrap a bit of tape around the wires at the base of the wago after inserting them all, puts less torque on the connector itself when shoving them in boxes and only takes an extra few seconds. I also pull on every wire pretty hard after inserting, I've had a few pull out!! I just cut it off and toss it. Don't want to mess around with loose connections.

    • @mikep490
      @mikep490 3 ปีที่แล้ว +1

      Good point, Andrew.

    • @cengeb
      @cengeb 2 ปีที่แล้ว

      nowhere in the instructions does it say to tape them...it's as dopey as taping twist wire connector, useless and made up nonsense

  • @richardnoggin8696
    @richardnoggin8696 4 ปีที่แล้ว +17

    They are great ! FYI do not force 12ga wire in deep, the wire will transfer heat to the plastic case and separate in the future. of the 12000 we have installed in the early years (2001) maybe 4 failed up to around 2010 . I also learned to cut stranded 12ga. wire on a slight angle to ease installation !

    • @RadioRich100
      @RadioRich100 ปีที่แล้ว

      None should have failed, but you dont know many failed, unless you attached your phone number to each one?

  • @petertate3436
    @petertate3436 3 ปีที่แล้ว

    Wow... makes me glad I’m in Australia guys.
    We have similar to your yello stuff but you twist the conductors together. The back of the power point has the screw lock down type connections.
    You’d have no trouble twisting three active wires together in the back of the point. Power circuits here are 2.5mm even with us having 240v.
    In the average home here it’s either metal studs or wood. With most of the walls gyprock (drywall).
    If the points are put in at the start of a house biuld. There is a metal frame that gets nailed to the stud for the sparky to fit the point to later (after the walls go up). If it’s done after there are things called c clips.
    We don’t do the box in the wall. The back of the point is open to the inside of the wall. The point does all the joining and holding. Much faster.

    • @johndododoe1411
      @johndododoe1411 2 ปีที่แล้ว

      Also in 230V land here. We have a choice and mix of 4 box types: On-wall boxes that are fully on the surface. Front-inserted boxes that are pushed into a hole and clamp themselves to the back of sheetrock or wood panels. In-wall regular boxes that can protrude to the surface but not beyond and cemented-in boxes that can be pre-installed (without wires) in concrete walls, connected by equally cemented in pipes at the prefabricated wall factory. Once the concrete walls are up, the state licensed electrician can pull wires and install outlets without weakening the load bearing walls.

  • @tommymadux3646
    @tommymadux3646 4 ปีที่แล้ว +1

    Same I only use the push in connectors when I have to and it’s more of a temporary fix. I don’t trust them one bit plus the clip on the wire just like back stabbing outlets does and look how that turned out over time. Same concept just different housing. Nothing beats a good name brand wire nut and pre twist the wire. I have pulled out many outlets and junction boxes and have seen the connections just come right apart even though the wire might was twisted down super tight but the wire was not pushed in far enough when installed or when there is more then 2 wires there’s not enough wire making contact to the wire but and two will stay in buy one falls out. I pretwist my wires and once twisted cut the end at a slight angel and in some cases use a 5/16 nut driver to spin on the wire nut. I never have a connection come undone or fall apart unless you want it to.

  • @danharold3087
    @danharold3087 4 ปีที่แล้ว +11

    Looks great but I have had bad luck with push in outlet wiring.

    • @cengeb
      @cengeb 3 ปีที่แล้ว

      that's cus you did it wrong

  • @usmc6153
    @usmc6153 4 ปีที่แล้ว +4

    I didn't know you could remove them. Nice tip!

    • @Dennis-ys8ho
      @Dennis-ys8ho 4 ปีที่แล้ว +2

      Don Brooks FYI -- you can only reuse with the same gauge wire or larger, NOT smaller.

    • @SRT480HP
      @SRT480HP 3 ปีที่แล้ว +1

      The fact that you can remove them so easily should be the first indication that they shouldn’t be trusted.

    • @tommymack3210
      @tommymack3210 3 ปีที่แล้ว

      @@SRT480HP lol

  • @ggrosklos2
    @ggrosklos2 4 ปีที่แล้ว

    I am removing a wall (top half) my wiring for the stove is in. I have to extend the wiring around and back to the same location these will work on extending the wring ? I will be using a junction box also where the wagos would connect the exsisting to the extension

    • @BenjaminSahlstrom
      @BenjaminSahlstrom  4 ปีที่แล้ว

      As long as your connections are made inside of the junction box then you should be fine! Just make sure that the wagos that you use are rated for the size wires that you are using. Good luck on your project!

  • @Anon21486
    @Anon21486 4 ปีที่แล้ว

    I saw these being used for a light company display (displaying LED lights) and they connected many of these (their display was 3 pieces and set up was roughly 10 minutes to connect 10-15 different lights with these connectors). I find them completely intriguing as these seem to be a much easier solution for 18AWG cables I have to connect from time to time.

    • @wizard3z868
      @wizard3z868 3 ปีที่แล้ว

      if you are going to be reusing a lot of the time look into the lever wagos .

  • @robertstonebreaker8394
    @robertstonebreaker8394 4 ปีที่แล้ว +6

    That’s all I ever use these days lever wagos nuts perfect connections got their own buss bar and they take up less space in box’s !! Good video

  • @walterb299
    @walterb299 4 ปีที่แล้ว +11

    I always strip the sheath off the cable before entering it into the box way easier and faster.

    • @SuperVstech
      @SuperVstech 4 ปีที่แล้ว

      Walter B that is a bad idea, the jacket protects the conductor insulation during penetration of the box gripping, also, the ease of getting the correct conductor length and jacket entry if done inside the box.

    • @benevolenthighwayman882
      @benevolenthighwayman882 4 ปีที่แล้ว +2

      I always slit the cable before entry but leave the sheath on until inserted.
      For the ground, I spin them together inside the box, install a crimp sleeve and trim off all but one wire for the pigtail to come out 4 inches. This keeps the cables from being pulled out of the box. Also, I turn the neutral and ground counterclockwise and the hot clockwise so that the neutral ends up on the left and hot on the right, directly behind the outlet. Also, I insure that all wagos are installed with the open side down to prevent debris and moisture from collecting.

    • @Nate-ud2yt
      @Nate-ud2yt 3 ปีที่แล้ว

      @@benevolenthighwayman882
      You dont mind using wagos then? they dont arc over time?

  • @wb5mgr
    @wb5mgr 4 ปีที่แล้ว +1

    A few years ago I quit using wire nuts and moved to Buchanan Connectors. If you’ve never used them before they are a copper sleeve that crimps over the group of wires with a compression tool and then they are capped with cap which resembles a marrett that snaps over them.
    Voltage drop with these style connections is much less under load than any other style I have used.
    The wago connectors are easy, but I find they don’t carry high current nearly as well as a marrett style or better yet the Buchanan style.

  • @_1ben
    @_1ben 3 ปีที่แล้ว

    Thank you for taking the time to share

  • @seanthiar
    @seanthiar 3 ปีที่แล้ว +36

    I'm german and my first qualification was as an electrical engineer. There are three things I saw that I felt to be wrong even in the USA. There were more things that let me cringe like the cable nuts and the blank copper but that's the difference between Germany and the USA.
    1. Never remove the cable insulation with a knife - you can a) destroy the insulation of the single wires and b) damage the copper in that way that the gauge changes. There are tools for removing insulation without any danger for the inner wires and they are designeed in a way that even with little space you got no problem to strip the insulation of.
    2. Whereever you install a cable - Always leave the groundwires longer than the other wires. That makes sure that when somebody rips for example an outlet out of the wall that the last wire that disconnects is the ground and not a live wire. A still connected live wire could endanger a person. For example electric heater and somebody falls over the cable in a way that rips the socket out of the wall. It's possible that because of that accident the case of the heater is internally connected to the phase and if somebody touches the case the body is used as a way to ground. If ground is the last that disconnects the danger is less that any touchable part of the heater is on a live wire without a blowing fuse.
    3. Connectors always face up and are at the highest point of a receptacle. If water gets into the receptacle because of a leaking roof, leaking water pipes or condensate etc. it does not collect in the connectors if they are on the highest point.
    And because I'm sure some will ask what let me cringe - two additional things. First the blank ground wires. If you got a defective insulation you could get the live wire connect to the ground wire and as far as I know in the US is no GFCI for the whole house like in germany that react as soon as a groundwire touches a live wire. They exist only for some outlets in the US or with some extension cables - please correct me if I'm wrong. And the second is the cable routing. To remove danger all cables in germany are in an area between two inches and a foot from the ceiling and at every outlet the cable goes vertical in the direction of the cable area near the ceiling and goes in that area to a central junction box in the room. Outlets are not daisy chained over more than a distance less than an inch. You only daisy chain if the receptacles are side by side. The same rules are for water oulets etc.That is because when somebody works at the wall - putting a nail in it, a screw, cutting a part out of it, you can always be sure that without needing to check it a cable will always be only above an outlet or near the ceiling. No danger to hit a live wire with a nail when you put a picture on the wall. If somebody want to read about the german rules for electrical installations just search for VDE DIN 0100.
    BTW WAGO connectors are used in germany since the 1970's, because WAGO is a german company with it's headquarters in Minden Germany. And the WAGO connectors that are used today were invented in the 1980's.

    • @kentuckybeardsman
      @kentuckybeardsman 2 ปีที่แล้ว +2

      bro get out of the books and get into the field. I've stripped back miles of wire never once cut the single wires insulation. not once!!! second if you have water 18" up to the elec box or even water running down the wall into your box, the water getting into the wago is the least of your problems. lol

    • @tristanedwards1340
      @tristanedwards1340 2 ปีที่แล้ว +1

      Okay true king of Gondor

    • @rkalle66
      @rkalle66 2 ปีที่แล้ว

      @@kentuckybeardsman In US homes are framed and so leaky that you are right. Water will not collect but rotting the house.

    • @kentuckybeardsman
      @kentuckybeardsman 2 ปีที่แล้ว

      @@rkalle66 do you live here? Have you worked in and around houses here? Have you worked for a good crew in the states?? No, oh well I guess your not speaking from experience but just assumptions and I would have to wager you know what they say about assumptions!?

  • @jdboy9
    @jdboy9 4 ปีที่แล้ว +4

    I've had lever lock wagos pop open when pushing wires into the box. I've started taping them for added security. I've never used the push in style because I mix stranded with solid so not really useful for me. Hopefully they hold up better than the push in outlets but time will tell.

    • @SgtZima
      @SgtZima 3 ปีที่แล้ว

      They can pop-up halfway sometimes but you still can't remove the wire. That requires you to fully disengage the lever, which requires a little bit of thumb force.

    • @jdboy9
      @jdboy9 3 ปีที่แล้ว

      @@SgtZima one time I had one lever open all the way causing connection issues. Partially my fault because I didn't nose the connector towards the back of the box.

  • @MrMultitool
    @MrMultitool 4 ปีที่แล้ว +2

    Way to Go WAGO! I love these connectors. Don't really care for leverlocks at all. Good demo Ben.

    • @MrMultitool
      @MrMultitool 4 ปีที่แล้ว +2

      UPDATE! I think I like the lever locks better now that I know the proper way to use them. The newer ice machines with 209 uses them.

  • @TheBalajivt
    @TheBalajivt 3 ปีที่แล้ว

    I love your videos and very helpful. I’ve a query to pass my rough.
    I’m running 12/2 wire for 10 outlets with 20amp breaker switch in my home theater room. Can I daisy chain the same 12/2 for the lights & switches in the room or I should run separate 14/2 wire with 15amp breaker switch?

  • @MrTooTechnical
    @MrTooTechnical 4 ปีที่แล้ว +6

    Great vid. I only use wago lever nuts. They rock. And I only do pigtails.

    • @aaron74
      @aaron74 4 ปีที่แล้ว

      Yes, pigtails are really a must. Not a must in the strict sense, but a practical sense... you SHOULD pigtail to receptacles.

    • @sinistersparky9657
      @sinistersparky9657 4 ปีที่แล้ว

      It IS a code requirements for commercial and industrial but for Residential I prefer side-wire loop-through topology - it's faster, easier to troubleshoot, and every bit as secure as pig tailing. AND I can have an apprentice wire receptacles and switches and still be able to inspect the work. I can't trust an apprentice to get a wire nut on properly in pigtails so then I have to troubleshoot their work.
      But to each their own right? Pig tailing has advantages for sure but it has drawbacks as well. My 2 cents

    • @aaron74
      @aaron74 4 ปีที่แล้ว

      @@sinistersparky9657 Check out backwire devices. Those are the best of both worlds: you can insert two conductors per screw, so you have essentially a pigtail and tap in one.

  • @GeoFry3
    @GeoFry3 4 ปีที่แล้ว +12

    Love the lever versions the best.

  • @safffff1000
    @safffff1000 4 ปีที่แล้ว +2

    I like the wagos with clip downs much better for undoing them forany reason and reuse

  • @pbertf24
    @pbertf24 3 ปีที่แล้ว

    Great video ! thank you for sharing the knowledge

  • @arturorgarcia1089
    @arturorgarcia1089 4 ปีที่แล้ว +10

    I WOULD ALSO COVER THE OUTLET BOX WITH A PIECE OF CARDBOARD OR MASKING TAPE TO KEEP OUT THE CRUD FROM THE DRYWALLERS AND PAINTERS.CLEANER RESULT.

    • @sinistersparky9657
      @sinistersparky9657 4 ปีที่แล้ว +4

      Yes, and a side benefit is being able to still read writing on the wires. I hate scraping that crap out of my boxes - some hacker tapers will even clean their knife on the box 🤯

    • @sinistersparky9657
      @sinistersparky9657 4 ปีที่แล้ว +1

      @@treyhart6861 indeed - I go back (or send an apprentice) after the 4 way inspection is done - I've also had an inspector ask me if we were going to tape the boxes up lol 🤷‍♂️⚡
      Admittedly though, I haven't done a tract house in twenty years - I'm mostly commercial/ industrial and do a custom home occasionally. Those jobs afford a little more time for that kind of thing versus production home building 👷🏻‍♂️👨‍🦳

    • @ikester475
      @ikester475 3 ปีที่แล้ว

      But only inside the box. Covers extending outside the box would be ripped off as drywallers want/need the outside edge of the box as a reference for their drywall cutting tool.

  • @rayflint261
    @rayflint261 4 ปีที่แล้ว +4

    When you roll the wires into the box, you are now allowing the Sheetrock guy to cut the middle of your wires with his roto zip. You should zigzag the wires into the box so if he does screw up with the roto zip, he will only zip off the very outer insulation.
    R

  • @anthonymiccijr6380
    @anthonymiccijr6380 3 ปีที่แล้ว

    Nice clean work!!

  • @leopoldogonzalez8068
    @leopoldogonzalez8068 4 ปีที่แล้ว

    Not too concerned about the best utility knife, but it was a very informative presentation as to how to do the boxes with a receptacle. I liked it, and thanks for letting me know about the wagos? I'll sure check them out.

  • @alphasaiyan5760
    @alphasaiyan5760 3 ปีที่แล้ว +4

    A “gut hook” blade is the best I’ve found in my 21 years of electrical work for cutting the sheath of Romex.

    • @user-dr2pg8fk2i
      @user-dr2pg8fk2i 3 ปีที่แล้ว

      Like a roofing blade or...?

    • @alphasaiyan5760
      @alphasaiyan5760 3 ปีที่แล้ว

      RJ na it’s a knife that has a hook on the end of the blade.

    • @ikester475
      @ikester475 3 ปีที่แล้ว

      @@alphasaiyan5760 so like a roofing blade then.

  • @terencegrace8246
    @terencegrace8246 4 ปีที่แล้ว +110

    I definitely twist current carrying conductors when using wire nuts

    • @jimdavis6833
      @jimdavis6833 4 ปีที่แล้ว +14

      ALWAYS! Do it well the first time and you seldom get call backs. Call backs are on you.

    • @zalmaflash
      @zalmaflash 4 ปีที่แล้ว +47

      I am a licensed electrician and I will NEVER use a Wago type connector or use the "push-in" type switches or receptacles. Bad connection/fire hazard...

    • @waggtech8793
      @waggtech8793 4 ปีที่แล้ว +4

      Never have seen a failure with that method.

    • @REXXSEVEN
      @REXXSEVEN 3 ปีที่แล้ว +3

      @@zalmaflash as soon as I heard that the wago connectors use a push in and release latch on the wires my mind went straight to that. I have seen a video or two on TH-cam with electricians strongly recommending against using any kind of electrical device such as a receptacle or switch or anything that is going to handle household electrical wire by using push in connectors.
      Thanks. I will just keep on using wire nuts. I hardly ever do this kind of work because I'm a do-it-yourselfer, but I'll stick to the wire nuts thank you.

    • @markchidester6239
      @markchidester6239 3 ปีที่แล้ว +5

      NEC use to at least say that you have to have two twists on the wires before installing a wire nut.
      Maybe that was before they started putting the metal insert into the wire nut.
      Try doing that with 4 #12 wires.

  • @samuelt5131
    @samuelt5131 2 ปีที่แล้ว

    Been using Wagos for a long time. And the ones with the levers are even better.

  • @patrickpeterman8736
    @patrickpeterman8736 ปีที่แล้ว

    Very informative great video'!! I,m installing a 12-volt dc light switch; how would I wire this using WAGO, S I have 14/2 Romex for the line power and 14/2 for the load side; I,m just a little confused about using pigtails to power the switch without blowing fuses everywhere; any advice would be appreciated; the switch is an SPST 2 PRONG 12 VOLT SWITCH: thanks again,PJP

  • @cravinbob
    @cravinbob 4 ปีที่แล้ว +22

    There is a tool for cutting the shield plastic on Romex type wire. Razor knives are handy but you will cut into the wire often.

    • @wilbready
      @wilbready 3 ปีที่แล้ว

      I bought that tool a few months ago and love it! Never cut my hand or the wires but the potential was there every time.

    • @itaintrocketscience
      @itaintrocketscience 3 ปีที่แล้ว

      Never seen a electrician use one on the job.
      Electrician here 25 years

  • @curtdenson2360
    @curtdenson2360 4 ปีที่แล้ว +11

    As A Master electrician for over 40 years and still working the wago is 16 psi, a wire nut installed properly is 10,000 PSI lots of fires were started by outlets with the same principle as a wago, while the new led light does not draw like the old incandescents, I don't recommend the wago for anything but the ground, Grasshopper. Trading an old fire problem for a new fire problem (wago) is not desirable, turn the wire nut approx 9 times pull all wires to ensure a proper installation Check the code now only one set of wires to each electrical device, we used to soldier these same connections it was not desirable either heat at the connection always causes a downstream failer. it is also a good Idea in outdoor or damp areas to apply GE Silicone its also listed for this purpose corrosion is always a problem around any connection. long term. Real on the ground experience, Millions of units installed.

    • @--JohnDoe
      @--JohnDoe 4 ปีที่แล้ว +1

      You say only one set of wires to each receptacle? Where at in the nec does it say that? Thank you.

    • @renteria4540
      @renteria4540 4 ปีที่แล้ว

      As experience man on electricity is true tha the breaker has to be same brand as the panel box? I'll appreciate your answer thanks

    • @emotionz3
      @emotionz3 4 ปีที่แล้ว

      That’s an interesting perspective. It does seem that arc fault breakers are necessary for WAGO’s to be long term safe since they definitely have a higher failure rate. It’s better to trip the circuit before there is a total short from a melted wago.

    • @kikiv1993
      @kikiv1993 26 วันที่ผ่านมา

      Fortunately, all of Europe has come out of the 20th century and uses WAGO and for some reason there are no problems with them.

  • @jerseyjim9092
    @jerseyjim9092 3 ปีที่แล้ว

    Nice tutorial. I've been curious about wagos but I've always put them on the same level as the back push pins on receptacles which Ive never trusted. You've given me good reason to give them a try. I also in the pretwist group. It may not be required but I guess I like being able to visually see that the wires are secured. Maybe they should make clear wire nuts 🤔

    • @wizard3z868
      @wizard3z868 3 ปีที่แล้ว +1

      look into the lever wagos

  • @TheLostAdventuress
    @TheLostAdventuress 2 ปีที่แล้ว

    Clean video demonstration

  • @glamdring0007
    @glamdring0007 4 ปีที่แล้ว +14

    I use Wago lever locks all the time...best improvement in home electrical in decades.

    • @SgtZima
      @SgtZima 3 ปีที่แล้ว +3

      The new lever nuts are the BEST. I really don't like push-in connectors.

    • @tommymack3210
      @tommymack3210 3 ปีที่แล้ว +2

      @@SgtZima Have you seen the new push in WAGO? WAGO 2273 series. If you are tight in space, these are SUPER slim. Even slimmer than the lever wagos.

  • @herbward5240
    @herbward5240 4 ปีที่แล้ว +11

    I am definitely in the camp of a wire loop under a tight pan head screw which makes a better and more reliable connection. But the lever locks do look to be well made.

    • @mrromantimothy
      @mrromantimothy 4 ปีที่แล้ว

      You get a thousand pounds of pressure with a tight screw I'm not so sure you get any of that with the waggle

  • @bondo1955
    @bondo1955 4 ปีที่แล้ว +1

    I pre twist with duck bill vise grips trim extra bare copper then wire nut but I love to try the wago

  • @SadieBenz317
    @SadieBenz317 2 ปีที่แล้ว

    i have a 123 volt wires that i'm using for lights on a headboard and wires that connect to the switch broke what size wire connector would you recommend ? my dog chewed right through them

  • @bryanwight765
    @bryanwight765 4 ปีที่แล้ว +20

    They seem to have less “bulk” in the box alsp

  • @TNFTAW
    @TNFTAW 4 ปีที่แล้ว +111

    I'm a 20 yr service electrician. Always find failed wagos, rarely find a failed wirenut splice.
    Take that for what it's worth.

    • @jamesbarca7229
      @jamesbarca7229 4 ปีที่แล้ว +20

      I can't say I've come across many Wagos, but I can't even count how many times I've found failed connections when push connectors are used on the back of receptacles. I don't see how Wagos are any better. I always say that no electrician worth his salt uses push connectors. It's just asking for trouble down the road.

    • @joeborovina4769
      @joeborovina4769 4 ปีที่แล้ว +5

      amen to that , that's what we do splice, trying to make a trade with out required skills. No electrician should ever stab wire a receptacle. That is the meaning of lame...

    • @ACDC940
      @ACDC940 4 ปีที่แล้ว +7

      Jason Weiner you are so correct and the other problem is not enough surface contact with wagoS which is the same when not using the screws on a receptacle versus the push tabs. Constant full load causes the push tabs to fail because of the high resistance do to very little contact between wire and tab

    • @cumberland1234
      @cumberland1234 4 ปีที่แล้ว +16

      From a UK sparky I am surprised you still use wirenuts, we used to have them and only come across them nowadays in old installations, usually when trying to find the break in the circuit. I don’t know if the wirenuts you have are different to the type we used to have though. When I used to do installation work I used connector strip though the industry now seems to be going towards the push (maintenance free) connectors. Wago is a manufacturer of these and there are also poorer quality copies about, personally I don’t know of any failures of genuine Wago connectors which have been fitted properly but we do run all domestic circuits on 230v so our current will be lower. Also we wouldn’t connect like you do in a back box, we’d connect all the conductors to the socket outlet (receptacle) albeit ours are quite a bit different to yours.

    • @seanclark8452
      @seanclark8452 4 ปีที่แล้ว +4

      @@jamesbarca7229 My whole house was done with push ins dammit. The receptacles and switches are actually splitting apart so I'm having to change everything out (and use the screw terminals. sheesh)

  • @stefandotp
    @stefandotp 2 ปีที่แล้ว

    Love Wagos. First got introduced to them when I did an internship for an electrician in Germany back in 2011

    • @Tattboy1000
      @Tattboy1000 2 หลายเดือนก่อน

      Do u still love them

  • @thomassemich4627
    @thomassemich4627 4 ปีที่แล้ว +2

    I have always stripped the Romex before I put the cables in the box. It is much easier. Just hold the Romex alongside the side of the box, get an idea how much insulation you want sticking in past the clamp if there is one, mark it with your thumb and strip it. Then insert it in the box. Just the way you would strip MC cable.

  • @DashPar
    @DashPar 3 ปีที่แล้ว +8

    I always pre-twist my wires with lineman’s pliers. Which is why I love the Wago idea!

    • @leekumiega9268
      @leekumiega9268 3 ปีที่แล้ว +1

      Do you use the push in feature on the back of cheap receptacles? It is the same type of holding mechanism. I do not trust them in the long run.

    • @DashPar
      @DashPar 3 ปีที่แล้ว

      @@leekumiega9268 I don’t use the push-ins on the back of receptacles, not because they don’t hold, but because I don’t want all that juice flowing through the receptacle. Which is why we use pigtails. But wagos seem to work well where I have used them on low voltage applications.

    • @leekumiega9268
      @leekumiega9268 3 ปีที่แล้ว

      @@DashPar Yes WAGO's are probably fine for low power demands like a standard light circuit but would not trust them in the long term for feeding a receptacle that could high amperage draw.

  • @MacDaddyRico
    @MacDaddyRico 4 ปีที่แล้ว +98

    I've pulled too many receptacles out of their boxes with the push-in type wire installation, and the wires come right out of the receptacle...the insulation of several of which were burnt to a crisp.
    That said, I'm not too fond of the push-in type devices, including these things.

    • @turboflush
      @turboflush 4 ปีที่แล้ว +9

      They are fine untill they get movement (loose recepticle) or excess current over time.
      Tests out there show the clip style nuts working fine under load.. but every one I have taken apart after it has been in the wall for years.. is loose or falls apart (heat). Usually when a recepticle has issues.. is because the push terminals were used.
      Just more contact area with a wire nut.
      Can't wait for the breakers in the panel to get these. Hahahaaa. Ooo maybe the main feed. JOKE

    • @wb5mgr
      @wb5mgr 4 ปีที่แล้ว +13

      There is a reason that commercial installations won’t generally allow push in connections on their receptacles . A spring loaded connection can’t offer a long term quality connection.

    • @nachtdiertje1972
      @nachtdiertje1972 4 ปีที่แล้ว +12

      We only use wago's and don't use wirenuts for decenia. I'm 27 year in the trade of electrician and if I've made 200 wirenutconnections, it is lot. Only wago's and especially the new ones with the little levers are ideal. The only thing is that you have to strip them accordingly to the measurements given on the packaging. Depending on your gauge you have to strip them correct, not longer, not shorter. If you do that correct, no problem.

    • @hornetd
      @hornetd 4 ปีที่แล้ว +21

      I have 45 Years of active service as a volunteer firefighter. 35 years of that was as in a rather busy suburban station. We stood watches because the calls were too frequent to wait for people to come from work or home. I would not care to have to count the number of times we responded to a fire or, when the occupant was luckier, to an odor of smoke and found a push in receptacle or switch as the root cause of the problem. Yes it is true that we ran calls were receptacle failures which involved bad screw wrap connections and worn out contact wipers arcing were the cause but no ware near a fourth of what we saw with the push in connections. My bread work was as an electrician but I thought I'd share what my experience with the spring contact connections in the failure mode context.
      Tom Horne

    • @mrromantimothy
      @mrromantimothy 4 ปีที่แล้ว +7

      @@nachtdiertje1972 I've made hundreds of thousands of terminations , if you want keep using them cuz I get a lot of troubleshooting calls and it's those Waggles I just have to replace them ,easy money as long as the place don't burn down and nobody gets hurt

  • @victornunez9204
    @victornunez9204 2 ปีที่แล้ว

    Awesome video thanks again very interested and informative 👍🏽

  • @tjalessi
    @tjalessi 3 ปีที่แล้ว

    Nice video Ben.

  • @hylogibbon
    @hylogibbon 4 ปีที่แล้ว +8

    In technical school (LATTC) we were taught to always pre-twist when using wirenuts.

    • @cengeb
      @cengeb 3 ปีที่แล้ว

      not in mfg instructions, unnecessary

  • @chrisf9607
    @chrisf9607 4 ปีที่แล้ว +6

    i pre twist the copper and the insulated part of wire trim copper to fit in wirenut and cap it

  • @RedArrow73
    @RedArrow73 4 ปีที่แล้ว

    Because many are just learning of Wago for the first time here!

  • @MrFranksplace
    @MrFranksplace 3 ปีที่แล้ว

    When i worked for comcast we used a three m type connector for phone as we added the security option . and i worked for a few electrical companies also and i asked which wire nut to use on pre-wire and was told whatever fit 😂 .like the wagos best .

  • @michaelm3255
    @michaelm3255 3 ปีที่แล้ว +3

    I like the lever-type Wagos when connecting stranded or a mix of solid and stranded wire. These are clamp connectors, not push ones. I have found old wire nuts that have loosened with stranded. If you use stranded ground pigtails, these are a good solution for grounding in junction boxes. I stick with wire nuts when the load may be high.

  • @xcmskim4
    @xcmskim4 4 ปีที่แล้ว +5

    I like the push in connectors but you cant beat the price of wire nuts!

    • @jamesdavies686
      @jamesdavies686 4 ปีที่แล้ว

      For an electrician yes, for a DIY weekend job it will be a difference of $5. I've used the wago lever nuts on my bedroom addition and they worked great.

    • @raycarter1588
      @raycarter1588 4 ปีที่แล้ว +2

      Your time is worth money. If it saves enough time then it’s worth it. I prefer wagos also because I have spent too many years making revisions and upgrades to old work. I always tell anyone on my crew, “Remember some day someone will work on this. That someone could be you”

  • @1hogchop
    @1hogchop 2 ปีที่แล้ว +1

    Great video my only suggestion especially for the occasional DIY'er or newbie would be to invest in a dual wire stripper (IDEAL® Reflex™ 12-2/14-2 Wire Strippers ) these strippers safely remove the romex sheath instead of using a utility knife that may nick the wire or the installer . Worth the money!

  • @naoabreg7413
    @naoabreg7413 2 ปีที่แล้ว

    So practical thanks you

  • @Dirkga
    @Dirkga 4 ปีที่แล้ว +5

    Wire nuts give less resistance between the connections If you use equipement that draw a lot of amps. Because wago`s only have a point connection it will then (by drawing higher amps) result in a voltage drop in the rest of the outlets within the same circuit. 😉 for in home use it can be okay. but for industrial use you always need wire nuts.

    • @sinistersparky9657
      @sinistersparky9657 4 ปีที่แล้ว +2

      The Lever Lock Wagos are every bit as good as a wire nut, sometimes even better because a wire nut is only as good as the installer - but even an apprentice can handle a lever 😑

    • @johndododoe1411
      @johndododoe1411 2 ปีที่แล้ว +1

      As long as the contact surface is larger than the wire cross section, it should be fine. WAGO claims their original products are designed to do that.

    • @Dirkga
      @Dirkga 2 ปีที่แล้ว

      @@johndododoe1411 Indeed but most of these have less contact surface then the cross section of a wire and that is when problems like voltage drop does occur.

  • @peterwhite51
    @peterwhite51 4 ปีที่แล้ว +10

    The TH-cam test on Wago current capacity was carried out by a UK spark called john Ward. Solid cable actually failed before connector despite all plastic having burnt away.

    • @brianreinhardt4050
      @brianreinhardt4050 4 ปีที่แล้ว

      You sir are incorrect. The WAGO connector burned FIRST and was the first to fail. Yes, the wire covering burnt off but the first connector to FAIL was the WAGO.
      th-cam.com/video/2uYD8e7idnY/w-d-xo.html

    • @krehbein
      @krehbein 3 ปีที่แล้ว

      @@brianreinhardt4050 kind of a moot point since in that test he was pushing 70amps through the connectors. Breaker would have tripped way before any wire burning.

  • @stevereese1943
    @stevereese1943 4 ปีที่แล้ว +2

    I just used wagos for the first time in my basement remodel and felt the same way. Why haven't I done this before? For 14ga I don't mind wire nuts, but for 12ga Wago's are just so much easier and can really cut down space in some 3 or 4 gang boxes with special switches (motion, dimmer, etc) One feature I liked was having an open hole on the wago, (i.e. a 4 hole wago for 3 wires) so I could easily add another wire in the future

    • @MookieMan1
      @MookieMan1 4 ปีที่แล้ว

      Steve Reese one thing to keep in mind is it’s super easy to use the correct size wago now and replace with a larger one down the road if needed. Saves money upfront.

    • @johndododoe1411
      @johndododoe1411 2 ปีที่แล้ว

      I loved switching from "choc-block" screw clamps to WAGO, wire nuts are not a thing here and screw connections need to be retentioned after the copper has been allowed to "flow" for a few weeks.

  • @efixx
    @efixx 4 ปีที่แล้ว

    Do you use the Wago 221s?

  • @Sjf542
    @Sjf542 3 ปีที่แล้ว +12

    You won’t see anything like wire nuts in Europe. Over here, twisting wires is a bad practice nowadays - too much installation error and makes testing and fault-finding a mess. Wago connectors hold the cable more than tight enough, there’s no need to twist the life out of it!

    • @paulgeorge1069
      @paulgeorge1069 3 ปีที่แล้ว +2

      You are so wrong those piece of shit wagos fail all the time twist those fucking bare ground wires and use a crimp sleeve. I've been doing electric for 40 years. If we go to troubleshoot can lights that aren't working properly and I see they are wired with wagos we cut them off and wire but them. But bye watching this guy use wire nuts he sucks look just like the ones a home owner does. The wire nuts should be tight enough to pick yourself off the ladder hanging on to them. When you twist them back off the wires should stay together. It's not rocket science. If using wagos was a good idea then it would still be leagle to stab #12's into a receptical. Many many houses have burnt to the ground because of that. That's why it's not leagle. So explain to me how a wagon differs from a receptical with stab ins. I realize loose plugs from poorly mounted boxes is the difference but if you are troubleshooting then you are moving them around and they fail. Throw those pieces of SHIT in the garbage please I'm tired of fixing crappy work. Electrical requires hand strength. Twisting the shit out of the wires does not break them they break because they are not properly stripped. You guys are as dumb as the yachting guys they write their own code witch calls for boat cable witch is fine stranded tinned copper and wire nuts are illeagle. I wire houseboats sometimes and when you run three ways it's a pain in the ass because just making up the nuetrals you have to use multiple crimp sleeves and jumper them together. The dumbest thing ever. Tinned wire for 120v in fresh water is assanine.

    • @FrozenThai
      @FrozenThai 3 ปีที่แล้ว +4

      @@paulgeorge1069 Personally think lever Wago (221) is the best connector and it has many benefits. I actually do the same as you. I remove wire nuts and toss them in the trash.
      On another note, how does the Wagos fail all the time? And is it really as bad as you make it out to be considering how many millions of homes they are currently in?
      And what type of stab in receptacle are you referring to? I assume it's the US-style one, and I think based on the picture I found that connection looks different and worse than Wago.

    • @SgtZima
      @SgtZima 3 ปีที่แล้ว

      ​@@paulgeorge1069 Most LED ceiling lights come with push-in connectors, but these are NOT Wagos, they're cheap knockoffs. I always snip them off and use Wago lever nuts, which are amazing. As far as wire nuts go, they're just not used in Europe and haven't been for a long time, and houses aren't constantly burning down there.

    • @paulgeorge1069
      @paulgeorge1069 3 ปีที่แล้ว +1

      @@SgtZima ya the lever nuts work good but are way too expensive. Very useful on 16 and smaller wires though.

    • @SgtZima
      @SgtZima 3 ปีที่แล้ว +1

      @@paulgeorge1069 they are pricey yeah. Great for connecting stranded to solid wire though

  • @RC-qb1dz
    @RC-qb1dz 3 ปีที่แล้ว +4

    I only use romex strippers and strip it before jabbing it into the box. Safer (for the wireman and the wire) and faster.

    • @danlux4954
      @danlux4954 3 ปีที่แล้ว

      Strip before installing in the box.

  • @abdulelkhatib2674
    @abdulelkhatib2674 3 ปีที่แล้ว

    I bought some of the newer wagos with the lever to lock and unlock them and they're great I haven't used a wirenut since. The only issue I've had with them is if rhe wire isn't straight or pushed in good it won't grab so give it a little pull to double check.

  • @PCJ52
    @PCJ52 4 ปีที่แล้ว

    Good information, thanks.

  • @raymondknappJr
    @raymondknappJr 4 ปีที่แล้ว +5

    After I was introduced to Wago's that is all I use. It seams to be a lot cleaner.

  • @ForgottenLore
    @ForgottenLore 3 ปีที่แล้ว +8

    I think most people get that feeling when they first use wagos, especially the fancy lever style ones for lighting.

  • @TheHighKirk
    @TheHighKirk 3 ปีที่แล้ว

    I wired and rewired some very large houses and shops with multiple breaker boxes and prefer the Wago over wire nuts any day of the week. Never had a problem with pull-outs or any other type of failure.

  • @Goodellsam
    @Goodellsam 4 ปีที่แล้ว +2

    You are a great teacher

    • @BenjaminSahlstrom
      @BenjaminSahlstrom  4 ปีที่แล้ว

      I do my best but I have a lot to learn myself! Thanks for being a subscriber!

  • @kylewells6871
    @kylewells6871 4 ปีที่แล้ว +13

    I like the wago lever nuts myself. And the best utility knife is actually the milwaukee fastback knife, trust me, I wont even entertain the idea of using anything else.

    • @Nitehouse
      @Nitehouse 4 ปีที่แล้ว

      Best blade I've used...

  • @alphasaiyan5760
    @alphasaiyan5760 3 ปีที่แล้ว +10

    The way I see it is , if the connector is UL listed , then it’s acceptable.

    • @paulgeorge1069
      @paulgeorge1069 3 ปีที่แล้ว +2

      Said olny by a person who doesn't do it for a living. 😕

    • @alphasaiyan5760
      @alphasaiyan5760 3 ปีที่แล้ว +3

      @@paulgeorge1069 lol I didn’t say just because it’s UL listed it’s the best for the job. I just said it’s acceptable. Also, I am a full time self employed electrician. Some municipalities require different connectors and different types of connections. But they all must be UL listed.

    • @Krankie_V
      @Krankie_V 3 ปีที่แล้ว +2

      Back-stabbing is covered by UL listing and accepted by code but it's still a garbage, failure prone connection. I just went through my home and replaced all the receptacles and did away with all the back-stabs and I noticed, the lights don't dim while the vacuum cleaner is on anymore like they used to. That's all the proof I need that a back-stab is a terrible connection.
      Nothing even appeared to have been hot, no charing or melting or anything like that. No burning smells. But there was clearly a problem somewhere which is now gone.

    • @alphasaiyan5760
      @alphasaiyan5760 3 ปีที่แล้ว +1

      @@Krankie_V I agree with you on that. A lot of my service call troubles are because of failed back stabbed receptacles.

    • @buzzincalifornia
      @buzzincalifornia 3 ปีที่แล้ว

      @@alphasaiyan5760 backstabbers in homes keep me in business, but i do replace them with straight wire screw-in outlets… i can never remember what they are called

  • @mikeratkowski3506
    @mikeratkowski3506 3 ปีที่แล้ว

    Great video

  • @kengodfrey9737
    @kengodfrey9737 3 ปีที่แล้ว +1

    Always use the pigtail method you used here. I have found melted receptacles when using the pass through (using all four receptacle screws) method of wiring.

    • @wr6392
      @wr6392 3 ปีที่แล้ว

      That's called series wiring. I hope you're not working with electricity if you don't even know that term.