Vaillant Ecotec Diverter valve change

แชร์
ฝัง
  • เผยแพร่เมื่อ 21 ต.ค. 2024

ความคิดเห็น • 70

  • @petel5560
    @petel5560 9 หลายเดือนก่อน +1

    Really helpful process tutorial. Best one i have found. Thank you CP Utility.

  • @ahmediqbal2828
    @ahmediqbal2828 ปีที่แล้ว +2

    Thank you for taking the time to make these videos!! Did my first diverter valve change today, myself and this video made it feel like a breeze so thank you bro. Your efforts are hugely appreciated!

    • @cputilitysolutions
      @cputilitysolutions  ปีที่แล้ว +1

      Nice one glad it helped!

    • @GasTraining
      @GasTraining ปีที่แล้ว +1

      Are you a new engineer then? How you finding it? Currently doing portfolio, really interesting work.

    • @ahmediqbal2828
      @ahmediqbal2828 ปีที่แล้ว

      @@GasTraining I am bro yeah, I qualified around 9 months ago in gas . Really enjoying it. Been doing the plumbing for a few years and it all ties in perfectly. I've watched my boss do a few but never actually done much repair work myself but I'm slowly getting the hang of it. Hope your portfolio and exams go well!!

  • @alanwild5890
    @alanwild5890 ปีที่แล้ว +2

    Thank for these instructions. Just replaced one using them 🏆

  • @ArifPolicewala
    @ArifPolicewala 8 หลายเดือนก่อน +1

    Thanks again Chirag.❤ that was another excellent accurate video

  • @macpatel7810
    @macpatel7810 3 ปีที่แล้ว +1

    Another great video CP. Always good to see real life scenarios where it doesn't always go to plan.

  • @gmtplumbing8559
    @gmtplumbing8559 3 ปีที่แล้ว +2

    Great vid been changing these occasionally for years never new about diverter mid position or purge mode ive made a note for next time, and keeping it real with the struggle you had 💪keep them coming✌

  • @sudhiradhikari19
    @sudhiradhikari19 2 ปีที่แล้ว +2

    Came across your channel, very helpful, for new guy like me.

  • @stevenjohnson6082
    @stevenjohnson6082 2 ปีที่แล้ว +6

    for reference take copper pipe off first before removing screws also push turbine clip down its easier

  • @geetee50
    @geetee50 2 ปีที่แล้ว +1

    Great job , I notice the insulation foam was shot. Normally on these the door foam goes brittle requiring a new door at £200+ due to seal failure so worth checking the burner seal with your analyser if you ever come across this condition of the foam insulation.

  • @Razz60
    @Razz60 3 ปีที่แล้ว +2

    Love your videos bro thanks for taking your time to making these helpful vids big respect to you

  • @gunsey876
    @gunsey876 2 ปีที่แล้ว

    Nice work, I had to do one a few months back, the condense had leaked previously an rotted the bottom screw, made it a right treat 😡

  • @dir5155
    @dir5155 2 ปีที่แล้ว +1

    Greetings! The display from 242/3-5 can be put on Vaillant 242/3-3??

  • @richardmoore8439
    @richardmoore8439 8 หลายเดือนก่อน +1

    I can't get the screws out from the back . All my drivers keep slipping as there seriously tight

    • @cputilitysolutions
      @cputilitysolutions  8 หลายเดือนก่อน +2

      Large flathead, tap it fairly hard (within reason) from an angle with a hammer to loosen it off anticlockwise

  • @lloydm2883
    @lloydm2883 7 หลายเดือนก่อน +1

    Thanks for this video. Now l know it's a job for a pro.. not me. What would a plumber charge to do this job???

    • @cputilitysolutions
      @cputilitysolutions  7 หลายเดือนก่อน +2

      Labour I charge 150+vat mate 👍🏾

  • @stevenjohnson6082
    @stevenjohnson6082 2 ปีที่แล้ว +1

    if you turn boiler power off after draining it will tell you if the water pressure sensor is block, if blocked it will still show pressure ie 0.5 or 0.3

  • @SuspiciousPixels
    @SuspiciousPixels 5 หลายเดือนก่อน

    whats the part number mine has the black top and I want to replace it with the new one. My existing part is DIVERTER VALVE 252457

  • @dinosauraccounts1411
    @dinosauraccounts1411 10 หลายเดือนก่อน

    Hi, I’ve changed the diverter valve. But ch-flow pipe getting hot when hot water is on.
    Another problem after Changing divertor - the hot water working fine - but heating goes one and rapidly heats up and cuts out - radiator symbol flashes.
    I did do P0 purging. Still no luck.
    Any help Would be really good.

  • @leeedwards3783
    @leeedwards3783 ปีที่แล้ว +1

    What long length screwdriver set do you have for these. I have one where the screws are shot so i need to drill them out. Anyone any advise on which size drill bit i need to drill out the screws. Thanks. Enjoyed the video

    • @cputilitysolutions
      @cputilitysolutions  ปีที่แล้ว +3

      I've got a 300mm bit holder that I use for these screws. I've had them chewed up before too but I've managed to free it by hammering a flat head onto the screw head and then able to tap it anti-clockwise to free it up

    • @leeedwards3783
      @leeedwards3783 ปีที่แล้ว +2

      @@cputilitysolutions thanks for the reply. Will have a go at tapping a flat head

  • @richardjones3112
    @richardjones3112 ปีที่แล้ว +1

    Great video,well explained,subbed.

  • @johnabiodun5540
    @johnabiodun5540 3 ปีที่แล้ว +2

    Done the exact same job on the same boiler the other day and when I ran the hot tap nothing happened... No tap symbol on the display nothing! Had to put the old motor back in the new diverter then it worked. Have you ever come across this before?

    • @cputilitysolutions
      @cputilitysolutions  3 ปีที่แล้ว +2

      Not come across that before mate, but I've come across a job where I thought it was the diverter as it was passing down heating, changed it and still doing same thing. Ended up being PCB not sending correct voltage to the motor to move it fully back and forth!

    • @stevenjohnson6082
      @stevenjohnson6082 2 ปีที่แล้ว

      if you have right filling tap open no water comes out of hot tap

    • @johnabiodun5540
      @johnabiodun5540 2 ปีที่แล้ว

      @@stevenjohnson6082 Water was coming out of the tap but the boiler was doing nothing.

  • @brahimaitoukharaz3039
    @brahimaitoukharaz3039 5 หลายเดือนก่อน

    hello, I have a vaillant ecotec plus vcw 346 3-5 boiler that works with natural gas and I would like to run it with propane gas. Thanks a lot

  • @blipyoung2180
    @blipyoung2180 3 ปีที่แล้ว +1

    Cheers mate for another great video.

  • @snowmansp
    @snowmansp 3 ปีที่แล้ว +1

    Hi, once this is done do you re test the gas and do flue readings or as it’s only on the wet side you just do Visual checks for leaks

    • @cputilitysolutions
      @cputilitysolutions  3 ปีที่แล้ว +1

      Whenever you've removed a case off a boiler you should do your 26.9 checks 👍🏽

  • @adiivanuta2573
    @adiivanuta2573 2 ปีที่แล้ว +1

    Hi, my boiler is vaillant vuw 260 . The problem is that if the chimney led flashing more than 90 seconds after it doesn't start, just running the pump forever. Any idea why?
    Thank you!

    • @cputilitysolutions
      @cputilitysolutions  2 ปีที่แล้ว +1

      Hi, this would require a diagnosis whilst in front of the boiler

    • @adiivanuta2573
      @adiivanuta2573 2 ปีที่แล้ว

      @@cputilitysolutions Thanks :(

  • @georgerobinson576
    @georgerobinson576 3 ปีที่แล้ว +1

    good job , thanks for showing

  • @parmbansal1
    @parmbansal1 2 ปีที่แล้ว

    Hi. Managed to follow your instructions. Thank you.
    I ended up draining the pump relief valve and now it's dripping outside on the copper pipe, what should I do, any tips what to do please?
    Thanks in advance

    • @cputilitysolutions
      @cputilitysolutions  2 ปีที่แล้ว +2

      Yes - never drain from the PRV! Unless you're planning to change it! There's boilers have 2 drain off points, one on the flow and one on the return. You'll need to either clean and re-seat the PRV or replace it.

    • @parmbansal1
      @parmbansal1 2 ปีที่แล้ว +1

      @@cputilitysolutions thank you so much for your guidance. I have taken it apart/cleaned the PRV sadly it still drips. I guess the only option is now to replace new one, hope that stops it.
      Thank you again! Any other tips would be much appreciated.

  • @Smokeblow
    @Smokeblow 2 ปีที่แล้ว

    Beautiful😍… nice work too 😳

  • @DenisSmart-p1f
    @DenisSmart-p1f ปีที่แล้ว +1

    Some helpful tips 👍💪

  • @rodknee87
    @rodknee87 3 ปีที่แล้ว +1

    Have you ever used the cartridge removal tool and just changed that instead of whole unit?

    • @cputilitysolutions
      @cputilitysolutions  3 ปีที่แล้ว

      I've heard of it but I've never used it myself yet. May give it a try but I've heard mixed reviews about it. Works for some people, but others have said they've been recalled a short while later because it leaks

    • @seangribbin6329
      @seangribbin6329 3 ปีที่แล้ว +1

      @@cputilitysolutions we use them all the time, as long as its installed correctly they are a dream

    • @leeedwards3783
      @leeedwards3783 ปีที่แล้ว

      Interesting. What's the cartridge removal tool.

  • @dir5155
    @dir5155 2 ปีที่แล้ว +1

    Молодец 👍

  • @Pb09120
    @Pb09120 2 ปีที่แล้ว

    Top man brilliant work

  • @raihankhan5638
    @raihankhan5638 2 ปีที่แล้ว +1

    Very useful video

  • @mcginn002
    @mcginn002 3 ปีที่แล้ว +1

    Nice one mate 👍

  • @allsystemsdownagain9553
    @allsystemsdownagain9553 ปีที่แล้ว +1

    Nice.

  • @1Patchilo
    @1Patchilo 9 หลายเดือนก่อน +1

    👏

  • @abualam4418
    @abualam4418 2 ปีที่แล้ว

    Good job mate,

  • @seanmcgee5060
    @seanmcgee5060 3 ปีที่แล้ว +1

    Take the pump out as well, so much easier

    • @cputilitysolutions
      @cputilitysolutions  3 ปีที่แล้ว

      Funnily enough this is what I do when I change the complete pump! It's in my other video 👍🏽

  • @traleyton8057
    @traleyton8057 10 หลายเดือนก่อน +2

    Clearly a very bad design of this 3 port valve. I guess the parts and labor cost exceeded £200. Almost criminal for a inherent bad design.

  • @paulrossiter9567
    @paulrossiter9567 3 ปีที่แล้ว +1

    Good on ya 👌🏻

  • @abchannel3737
    @abchannel3737 2 ปีที่แล้ว

    Excellent

  • @cezars4155
    @cezars4155 3 ปีที่แล้ว

    good stuff bud'!

  • @kapilsammy
    @kapilsammy 3 ปีที่แล้ว

    Bro didn't you forgot to take the diverter valve bracket mount screw when you started wiggling it and then said sh$t should come out lol nice video though

  • @AC_Milan1899
    @AC_Milan1899 9 หลายเดือนก่อน +1

    German build quality is so overrated