Installing a Daikin FLOOR STANDING mini split⎟HVAC Installation

แชร์
ฝัง
  • เผยแพร่เมื่อ 23 ส.ค. 2024
  • By using these links it doesn’t cost you anymore however by doing so you are helping the channel grow.
    Thanks for the support!
    FLUKE HVAC MULTIMETER KIT
    www.amazon.com...
    KNIPEX INSULATED LONG NOSE PLIERS
    www.amazon.com...
    KNIPEX INSULATED SIDE CUTTERS
    www.amazon.com...
    KNIPEX INSULATED PLIERS
    Currently Unavailable.
    KNIPEX INSULATED SCREW DRIVERS
    www.amazon.com...
    KLEIN (MEGGER) CONTINUITY INSULATION TESTER
    (This isn’t the megger I use personally because the one I use isn’t available anymore. I recommend this one).
    www.amazon.com...
    VESSEL ELECTRIC SCREWDRIVER
    www.amazon.com...
    MILWAUKEE BACKPACK
    www.amazon.com...
    KLEIN CABLE STRIPPERS
    www.amazon.com...
    PENCIL
    www.amazon.com...
    RATCHETING RIGHT ANGLE SCREW DRIVER
    www.amazon.com...
    ELECTRICAL LOCK
    www.amazon.com...
    O LIGHT TORCH
    www.amazon.com...

ความคิดเห็น • 55

  • @robalexander7348
    @robalexander7348 ปีที่แล้ว +3

    Hi Mitch,this looks a identicle model to my Daiken 5 kw floor mounted split sysyem, they are very efficient for all weather conditions here in the Southern Highlands NSW... Compliments on a nice neat install 👍

  • @sdgdfgdasdgsdf7354
    @sdgdfgdasdgsdf7354 ปีที่แล้ว +11

    Finally got it up and running. The only delays we had was because we realized we needed some extra parts (I’ll list that below) th-cam.com/users/postUgkxihMYiJNXcHdbH-7ihymsLz61l7jVyb5O . So we have a loft where our current hvac just couldn’t seem to keep cool during the summer. We have been using a window unit since we bought this house over 6 years ago (all the houses in this neighborhood were built in the 80’s and majority of the houses built like ours use a window unit). I hate window units because they are just so noisy and the one we had really only cools one side of the loft. I had contemplated upgrading our current HVAC, but with all the rising prices these days, it would take years before saving up enough to do that. With the advice of my father-in-law (used to run an HVAC business), he recommended we get an inverter instead. We thought we bought everything we needed, but there were just a few other parts we didn’t anticipate needing (which is what caused most of our delay). My friend and father-in-law did all the work to get it installed and running and now we have nice cool air circulating nicely throughout the entire loft. It is very quiet and even the outside unit is much quieter than our main HVAC unit. Saved ourselves thousands getting this.

  • @nixaeagle141
    @nixaeagle141 2 ปีที่แล้ว +1

    That wall radiator is slick .

  • @thearrislawson8537
    @thearrislawson8537 6 หลายเดือนก่อน

    A friend just told me about this type of unit nice install 🔥

  • @salvatoregiovanni8967
    @salvatoregiovanni8967 หลายเดือนก่อน

    2:56 whispers to self: “That’s not going anywhere.”

  • @connorbloom9616
    @connorbloom9616 2 ปีที่แล้ว +1

    Nice work brother! I'm on a job where the client wants 3 floor mount Daikin handlers recessed into the wall of every bedroom, just the smaller gray back. I'll let you know the outcome. Gotta scab in 2×4 to screw into

    • @maracservices
      @maracservices  2 ปีที่แล้ว

      I’m very interested how that will look. All the cuts in the wall will have to be perfect, won’t be easy 😬 good luck brother

  • @suldaancooling4207
    @suldaancooling4207 2 ปีที่แล้ว +1

    Fantastically work thanks eng👍👍🩸

  • @jasonliu9614
    @jasonliu9614 2 ปีที่แล้ว +1

    nice and neat, good one.

  • @benjaminwenman657
    @benjaminwenman657 ปีที่แล้ว

    I've never seen that duct that you use before. Looks like it has way more room then the stuff I've used.

  • @jennamoonchild
    @jennamoonchild ปีที่แล้ว +5

    Hi, did you check what is the minimum pipe length? Usually it is 2 to 3 metres (6 to 9 feets).
    I don't think it's much of a problem, if weather stays over zero Celsius. If weather stays below zero, it will constantly go to defrosting mode.

    • @maracservices
      @maracservices  ปีที่แล้ว +1

      Yep sure did. You’re correct though, this is shorter then the minimum length they state in the specs however I got told that it’s fine in my location by Daikin tech support.
      Long story short, the lowest temp you’ll ever get here on the coldest winters morning is about 6°c and that is rare. Normally a winters morning is about 15°c. I’ve never heard back from the client so I assume all is well.

    • @jennamoonchild
      @jennamoonchild ปีที่แล้ว +1

      @@maracservices Hi Mitch, I was almost sure there are no temps below zero there. I'm from Finland and I have three heat pumps ...and a fireplace ..and a few stoves. And a sauna. I'm like I don't belong in this country, because it's almost spring, when I'm becoming accustomed these freezing temps we have here in winter.

    • @maracservices
      @maracservices  ปีที่แล้ว

      @@jennamoonchild Finnish people must be tougher then Australians because I reckon I would not be able to survive such harsh climates haha. Sauna and ice baths sound crazy to me! A lot of houses here in Australia don’t have insulation in them to save money because it’s not necessarily required with our climate. Although I’d still put it in my house if I had the option.

  • @dylb8801
    @dylb8801 13 วันที่ผ่านมา

    So Ive just provided you with a few more views across you videos lol but noticed you didn't run a vac stat back in the day and vac through gauges/1/4 lines? Seeing you are more evacuation informed do you wish you knew what you knew now back in the day lol

  • @Ani-um3ls
    @Ani-um3ls 11 หลายเดือนก่อน

    Very nice clean work. But the minimum pipe length for all mininsplit type is 3m.
    Look at the manual instalation first.

    • @SilasMoleCatcher
      @SilasMoleCatcher 7 หลายเดือนก่อน

      Why only 3?

    • @jansenspanzu4083
      @jansenspanzu4083 22 วันที่ผ่านมา

      Because the extra meter of pipe needs more refrigerant ​@@SilasMoleCatcher

    • @SilasMoleCatcher
      @SilasMoleCatcher 21 วันที่ผ่านมา

      @@jansenspanzu4083 ??

  • @musakavalci9470
    @musakavalci9470 ปีที่แล้ว

    Excellent work mate. Tidy.
    Not having a pop just a couple of questions. No strength/pressure test before vacuuming lines? what's the minimum lineset recommended for that model unit?

  • @ianorr760
    @ianorr760 2 ปีที่แล้ว +3

    That’s the first time I’ve seen a console install, nice work as usual mate… No room up high I assume???
    My U4 fault had no power on t3, so I swapped out the outdoor board and fan motor and away it went…. Thanks again for sharing 👍🏼..
    Do you use the Daikin global service bank for sourcing the parts/models???

    • @maracservices
      @maracservices  2 ปีที่แล้ว +2

      Thanks mate. Yeah so this room had no room up high (to many windows). That’s good to hear about the U4 fault 👍🏻. I actually haven’t used the global service bank to be honest. I just ring spare parts and get a price and availability over the phone and then send them a purchase order via email. Iv got a few Daikin service call videos I want to get out but unfortunately I’m waiting for the parts to come in stock again. Daikin seem to be struggling to keep everything in stock at the moment.

  • @frankrizzo7307
    @frankrizzo7307 5 หลายเดือนก่อน

    I'm thinking of getting the MFZ-KJ for my basement, but the operation manual mentions nothing about condensate. Is there a built in pump or do you need to add a condensate pump?

  • @alvaroherbert35
    @alvaroherbert35 2 หลายเดือนก่อน

    What Size of electrical wire for thay unit?

  • @charinafarry7149
    @charinafarry7149 ปีที่แล้ว +1

    wow

  • @terrancegrant1664
    @terrancegrant1664 4 หลายเดือนก่อน

    I got one; any ideal of how to clean it?

  • @ssikkema4222
    @ssikkema4222 6 วันที่ผ่านมา

    nice video.. but please the music, autotune hurts my ears. 😅

  • @dukeraul624
    @dukeraul624 2 ปีที่แล้ว +1

    Nice n clean. How many BTU’s?

    • @maracservices
      @maracservices  2 ปีที่แล้ว +1

      3.5kW which if I’m correct is 12,000 BTU’s (I think).

    • @dukeraul624
      @dukeraul624 2 ปีที่แล้ว

      @@maracservices 👍thanks

  • @arishem555
    @arishem555 ปีที่แล้ว +2

    Hey, Mitch. How is the unit doing after 8 months? Can you please share anything? :) Thnx!

    • @maracservices
      @maracservices  ปีที่แล้ว +2

      Running perfectly fine mate. The customer is very happy.

    • @arishem555
      @arishem555 ปีที่แล้ว

      @@maracservices THank you, Mitch. If you don't mind, - cannot find info about drain hose. Daikin specs saying "13/16 connector". But there is no such thing as 13/16 hose available. What hose should I order? both 9000BTU and 18000 BTU units have the same "13/16" connector.

  • @AM-si1jt
    @AM-si1jt 2 ปีที่แล้ว +1

    i want to have one and how much is cost

  • @prowesstv
    @prowesstv 2 ปีที่แล้ว

    No start up vid for the VRV ?

  • @Karma46819
    @Karma46819 4 หลายเดือนก่อน

    Does the floor model not come with the connectors already attached to the indoor unit? My normal Daikin split unit does

    • @maracservices
      @maracservices  4 หลายเดือนก่อน

      Sorry mate dont really know what you mean. Do you mean flare nuts? To connect the pipe to the unit?

  • @SOCIETECDSArnouville
    @SOCIETECDSArnouville ปีที่แล้ว

    Top

  • @agostinhomartins8373
    @agostinhomartins8373 ปีที่แล้ว +1

    Hey mate I have one of these currently flashing green and not working in heating, do you know any possible causes? Can't seem to find this model on any daikin app.

    • @maracservices
      @maracservices  ปีที่แล้ว

      Does it have a remote controller?

    • @agostinhomartins8373
      @agostinhomartins8373 ปีที่แล้ว +1

      @@maracservices yeah it does mate but haven't been out to check it just yet

    • @maracservices
      @maracservices  ปีที่แล้ว +1

      @@agostinhomartins8373 no worries. When you do, hold down the cancel button and scroll through the fault codes mate.

    • @agostinhomartins8373
      @agostinhomartins8373 ปีที่แล้ว

      @@maracservices 👍👍

  • @alisondennis4098
    @alisondennis4098 ปีที่แล้ว +1

    "You're body only make you go lovey dovey"? You have got to be kidding me. Sounds like written by someone who never graduated from high school. Makes me wonder about the quality of Daikin ACs.

  • @milerkos
    @milerkos 2 ปีที่แล้ว +3

    I WOULD LIKE TO HEAR HOW LOUD IS INDOOR UNIT.

    • @maracservices
      @maracservices  2 ปีที่แล้ว +1

      Next time I come across one I’ll make a video 👍🏻

    • @nonfiction_4life156
      @nonfiction_4life156 ปีที่แล้ว

      Don't bother wasting your time showing Miler !! It's so quiet they are used in music recording studios !! Get a hold of yourself Mr. Kos

  • @TheJuice484
    @TheJuice484 2 ปีที่แล้ว +2

    Line set too short

    • @maxd4968
      @maxd4968 ปีที่แล้ว

      Mine comes straight out the back and into the outdoor. It’s been working fine for 18 years

    • @hatenu2
      @hatenu2 11 หลายเดือนก่อน

      No such thing. Short line causes noise

  • @banega2311
    @banega2311 9 หลายเดือนก่อน

    And you are waiting for an electrician to connect three wires, phase, zero and ground??? )))))

  • @daveyboy8907
    @daveyboy8907 ปีที่แล้ว +1

    Music ruins it man.