    Learn What is Anchor Length Why Anchor length is provided and Also learn the basic of Bend and Hook in RC construction from basic mechanics.
    / @tonmoymaity
    Civil Engineers very frequently Encounter a term known as development length during preparation of structural drawing and in the site during construction work. Along with development length Anchor length also associate. There are many engineers who simply either memorize the formula for development length or the value for different different diameter rebar along with their Anchor Length.
    But as an engineer you should know the basic of development length first.
    Only then you can understand the logic behind the derive formula and the value of anchor length for different diameter steel bar which you provide during construction.
    In this video you will understand-
    Why anchor length is provided,
    The mechanics of anchor length,
    How to calculate anchor length,
    Provision in code for anchor length,
    What is bend and hook,
    minimum Bend and Hook Length for different diameter rebar etc.
    ○ Useful BOOK: amzn.to/2UVRuG4
    WATCH NEXT:
    How to calculate unit length of weight?
    • How to calculate weigh...
    What is isolated footing and how to read structural drawing for footing?
    • What is Isolated Footi...
    Different type of Admixture for using in Concrete.
    • What is Admixture Why ...
    Different Grade of Sand.
    • What is Grading of San...
    Water absorption test of Brick: Significance and Procedure.
    • What is Water Absorpti...
    =========================================================
    Don't forget to SUBSCRIBE my channel to get civil engineering video on ANALYSIS. DESIGN. Construction.
    =========================================================
    You may not find your Costly Engineering Class useful. But surely here you will get all the important civil engineering lesson not only FREE but INTERESTING!
    YOU MAY ALSO LIKE:
    Classification of Brick.
    • Classification of Bric...
    Batching of Concrete: Volume and Weigh Batching
    • What is Batching for C...
    Strengthening Process of Cement.
    • What is Hydration of C...
    DISCLAIMER: Links included in this description might be affiliate links. If you purchase a product with the links that I have provided, I may receive a small commission. But there is no additional charge to you! Thank you for supporting me so that I can continue to provide you with free engineering knowledge every week.
    And help you to develop your engineering skill.
  • วิทยาศาสตร์และเทคโนโลยี

ความคิดเห็น • 37

  • @senthilram7727
    @senthilram7727 หลายเดือนก่อน

    I had this doubt for a long time like differ b/w development and anchorage length thank you, make more content like this.

  • @abhijitsnair1950
    @abhijitsnair1950 4 ปีที่แล้ว +1

    Awesome class sir. I definitely share to my friends

  • @DACVL4U
    @DACVL4U 3 ปีที่แล้ว

    Appreciate your endeavor

  • @nirnayshanoo
    @nirnayshanoo 3 ปีที่แล้ว

    Very conceptual

  • @ankusharma7465
    @ankusharma7465 3 ปีที่แล้ว

    sir if we want to provide chajja ( cantilever) we don't use development length concept right???

  • @mangalnganbalairenjam4879
    @mangalnganbalairenjam4879 ปีที่แล้ว

    How to provide anchorage length for top most beam if the depth of beam and dimensions of column are small and size of rebars is large?

  • @civilqaqc9235
    @civilqaqc9235 3 ปีที่แล้ว

    Awesome video...fully clear concept.

  • @mhchow1727
    @mhchow1727 ปีที่แล้ว

    Sir, how about lap length ? Is the lapping length to be provided is similar to the concept of anchorage length? Thanks!

  • @nikhilrana7458
    @nikhilrana7458 10 หลายเดือนก่อน

    sir please clear this doubt Iam not getting the meaning of this codal provision
    Anchorage length of straight bar in compression
    shall be equal to the development length of bar in
    compression

  • @devidassatpute6823
    @devidassatpute6823 3 ปีที่แล้ว

    Thank you sir👍

    • @TonmoyMaity
      @TonmoyMaity  3 ปีที่แล้ว

      You are welcome dear.

  • @funtime8557
    @funtime8557 ปีที่แล้ว

    Thanks a lot

  • @ankitsrivastava8119
    @ankitsrivastava8119 ปีที่แล้ว

    If 4d for each 45 degree bend then how IS 2502 calculate 20d for 90 degree bend stirrups

  • @aliqadri4672
    @aliqadri4672 ปีที่แล้ว

    Approx total Length of bar (L) Measured along center line ...what it mean ???

  • @amartyarandive6078
    @amartyarandive6078 2 ปีที่แล้ว

    Thanks

  • @shivajibangaru7438
    @shivajibangaru7438 4 ปีที่แล้ว

    One doubt sir..
    Already we calculated the Ld so it's the full length we have to provide ..so simply we can bend the remaining length after reach to end of the member..again why we have to calculate to Anchorage length

    • @TonmoyMaity
      @TonmoyMaity  4 ปีที่แล้ว

      Awesome question...let say 1 unit force is coming to the bar. Now remaining length after reach to the end of the member is only one unit. So bearing stress on concrete is force(1)/(length(1)*dia(1))=1. But say allowable bearingstress on concrete is 0.5. so if length is twice it is ok. So, here bearing stress come into the picture.

  • @robertmihalinac
    @robertmihalinac 3 ปีที่แล้ว

    Why dont we check reinfocement in fixed end beams and columns for pull-out and splitting failure?

    • @TonmoyMaity
      @TonmoyMaity  3 ปีที่แล้ว +1

      Pull out check should be done if tension in the bar is too much high which normally doesn't arise in the beam column junction.

    • @robertmihalinac
      @robertmihalinac 3 ปีที่แล้ว

      @@TonmoyMaity Thank you.

  • @jawedkhan7375
    @jawedkhan7375 2 ปีที่แล้ว

    4xdia for each 45 deg is for bot ms or hysd bar ?

  • @robertmihalinac
    @robertmihalinac 3 ปีที่แล้ว

    Does reinforcement in walls and columns have good or poor bonding condition?

    • @TonmoyMaity
      @TonmoyMaity  3 ปีที่แล้ว +1

      Bonding depends on the grade of steel and concrete only.

    • @robertmihalinac
      @robertmihalinac 3 ปีที่แล้ว

      @@TonmoyMaity Thank you. I have B500B, and C30/37. Many people say that in walls and columns are good bonding conditions.

    • @TonmoyMaity
      @TonmoyMaity  3 ปีที่แล้ว

      @@robertmihalinac ha haha

  • @skvirat7404
    @skvirat7404 3 ปีที่แล้ว

    Why bond strength is increased 25 percent in compression zone ?

    • @TonmoyMaity
      @TonmoyMaity  3 ปีที่แล้ว

      For the same reason of why passive earth pressure is more than active earth pressure.

  • @aliqadri4672
    @aliqadri4672 2 ปีที่แล้ว

    Anchor bar or achourage lenght are same ..????

    • @TonmoyMaity
      @TonmoyMaity  2 ปีที่แล้ว

      I don't get you

    • @aliqadri4672
      @aliqadri4672 2 ปีที่แล้ว +1

      @@TonmoyMaity i mean anchourage lenght may jo bar hota hay osko anchor bar bolty hain ???

    • @TonmoyMaity
      @TonmoyMaity  2 ปีที่แล้ว +1

      @@aliqadri4672 yes

  • @santanudas2876
    @santanudas2876 ปีที่แล้ว +1

    Tumi bangla tei bolo dada.english e bolte giye guliye felcho..bangla tei bolo..view o besi hobe..sobai subscribe o korbe

    • @TonmoyMaity
      @TonmoyMaity  ปีที่แล้ว +1

      Ha ha 😂..ja bolecho vai..