crank is not necessary, crank is only used to economise construction. if crank is not provided than u have to provide more extra top bars, so here more extra bars r provided in stead of crank, this is not economic construction but definately not faulty construction if extra top bars r sufficient to countract nagative moment...
Kya bhai sap aap video banakai thiksai bana nehi paya, rod niche ply sai kitna inches chhodkai rakhna chahiye, aur kaisai ply board ko touch nehi hoga,uska process, voice recording saath karna tha, aur camera bi slowly ghumakai shooting karna tha, ye video mai adha samajmai aaya adha nehi aaya.
Very good
The video is great, the bar arrangement is so smart
Thank you so much for making helpfull & knowledgeable video, best wishes from Pakistan.
Thank you for giving me knowledge about main bar and distribution bar but not clear about chair bar
th-cam.com/video/5yNmlBEJnNI/w-d-xo.html
crank is not necessary, crank is only used to economise construction.
if crank is not provided than u have to provide more extra top bars, so here more extra bars r provided in stead of crank, this is not economic construction but definately not faulty construction if extra top bars r sufficient to countract nagative moment...
Akash Gohel civil engineering is all about safety economy and time
Great work keep it up
@@idreesnisar6906 but if u say this construction technique is wrong than u r probably wrong....
There r lots of comments regarding this...
What kind of slab is this I know it's a solid slab but why top at beam areas
Nice work
th-cam.com/video/5yNmlBEJnNI/w-d-xo.html
Maadi veedu centring ethana mm kambi poduvanga
NICE
What is the thickness of the slab and cranked bar is also not provided.
Full length or room by room?
I really like in contruction.by the way,what size of the beam and matel for beam ? Thanks
th-cam.com/video/5yNmlBEJnNI/w-d-xo.html
Amazing video
Nice
Nice video
Simple idea
Near beam, lapping length is less. Why?
Lapping length is provided at the end of the support why
I think all beams are T-beams, so there is no need for cranking
Crank bar not given but extra bar took😀😀
Mention bar size plz
Nice video hai bhai!!!.Keep it up.Project ka start to end tak voice recording ke sath hi dalo to jada views aur like milega .
Corner Torsional Mesh in the slab for discontinuous end is not shown in the video.
Alternate bup bar not given...only extra top bar provided
th-cam.com/video/5yNmlBEJnNI/w-d-xo.html
No cranking of rebars?
Have you seen the automatic gun that ties the rebar togeather ?
Nic
you did not put concrete spacer
How are u find level of slab
Sleb Vance bhi nahi he
Kya bhai sap aap video banakai thiksai bana nehi paya, rod niche ply sai kitna inches chhodkai rakhna chahiye, aur kaisai ply board ko touch nehi hoga,uska process, voice recording saath karna tha, aur camera bi slowly ghumakai shooting karna tha, ye video mai adha samajmai aaya adha nehi aaya.
Where is crank in bottom reinforcement..less economical.
Where is crank??
how about safety
Safety nil
छत के बाहर बीम कितना निकाल सकते है
th-cam.com/video/IoAtBgmpBHo/w-d-xo.html
Can l get employed in your company as engineer
How many inches is the Ha
How many in is the hagh
th-cam.com/video/IoAtBgmpBHo/w-d-xo.html
किती mmm आहे गज
677
Why crank is not needed in this sla reinforcement
Exactly my doubt
SARTHAK MOHAPATRA cz there is enough covering on slab
Iska jo room ka bich ka bhag he vo kuch salo me juk sakta he
Sleb bandha vo galat
Must be huk 2 inch
Ye sarasar galat he
ঘভঙ
Not prfact
Very good
The video is great, the bar arrangement is so smart
Nice work