Electrical Output Testing Procedure

แชร์
ฝัง
  • เผยแพร่เมื่อ 31 ม.ค. 2025

ความคิดเห็น • 49

  • @t.d.harris1311
    @t.d.harris1311 ปีที่แล้ว +14

    Thanks for these videos, you are the only power equipment company that offers this type of support to your customers.

  • @joecool4656
    @joecool4656 5 หลายเดือนก่อน +9

    Thank you. This video was easy for me to follow. I discovered my friend’s stator coil was fried from letting a friend borrow it and let him “run a sump pump” (that’s a lie it was backfed by the grid obviously). The key here was measuring for voltage coming from the plug into the AVR block. There was no voltage! I realized then the stator may be damaged, and removed the AVR to discover extensive stator and rotor damage and burning!

  • @radiolandia
    @radiolandia 9 หลายเดือนก่อน +2

    I have seen about 50 videos, but this is the shortest and most accurate on this topic. Thank you very much for sharing

  • @nkem5908
    @nkem5908 6 หลายเดือนก่อน +1

    Thanks for the video it really helps me alot my generator is bringing power after watching your video doing the same test found out one of the brushes is eating ❤❤❤❤❤

  • @joepadilla7173
    @joepadilla7173 8 หลายเดือนก่อน +2

    You the best explain troubleshooting produre. Thanks you the best ...

  • @leroijr407
    @leroijr407 3 หลายเดือนก่อน

    Your videos are awesome. I have 2 champion generators. I am testing my model #100165, but do you know why does it has 4 wires out of the stator instead of 3 lioe my 10 starting watt does? It has a black, red and 2 of the blue wires. The blue connect together though.

  • @Rein_Ciarfella
    @Rein_Ciarfella 10 หลายเดือนก่อน

    I have been teaching myself small engine work for almost 3 years. I am currently restoring my second generator. This seems to be an excellent training video except for one detail which to me makes no sense.
    From 2:07 to 2:40 the Exciter Field is being tested. The narrator states that the voltage SHOULD be between 4 and 8V AC, but then immediately states if this IS the case the AVR needs to be replaced. Those two statements on their face seem contradictory (because of the word "should", which implies correct or acceptable). I suspect the explanation could be written more clearly and it ought to read thus - The voltage WILL read between 4 and 8 if the AVR IS FAULTY and DOES need to be replaced. If the voltage is OUTSIDE those parameters then the stator will need to be replaced.
    Do I understand that correctly?
    Thank you very much for this video - it has increased my knowledge in this area greatly! I will be referring to the links provided as well as your TH-cam channel for more knowledge.

    • @ChampionPowerEquipmentHQ
      @ChampionPowerEquipmentHQ  8 หลายเดือนก่อน

      We will be sure to review this. Thank you for your feedback!

    • @huntjunky1
      @huntjunky1 7 หลายเดือนก่อน

      That is correct...If the voltage in reading as indicated, the exciter field is working properly and the avr is the source of the problem.

  • @leroijr407
    @leroijr407 5 หลายเดือนก่อน +1

    Hi. My 2 year old generator from TSC was hooked up with the red wire from the AVR going to the right side prong on the brush, which is the outer i believe. Is that the correct side? I read that plugging backwards will fry the small circuits in the AVR. My unit is a 10k watt starting.

    • @ChampionPowerEquipmentHQ
      @ChampionPowerEquipmentHQ  5 หลายเดือนก่อน

      Hello. Please email us pictures of said wire to support@cpeauto.com, so we can verify this. Thank you.

  • @KoRnEdaddy87
    @KoRnEdaddy87 ปีที่แล้ว +1

    My brush test was above was like 40v and my stator test was between 4-8v.
    White wire connector on brushes is a bit burnt and black.
    AVR need replacing? My lights in the house are flickering when big loads come on and off and generally fluttering a little bit all the time.

    • @ChampionPowerEquipmentHQ
      @ChampionPowerEquipmentHQ  ปีที่แล้ว

      The brushes & AVR may need replacing. Please email us at support@cpeauto.com with the results of each test, so we can confirm what the culprit is. Thank you!

    • @KoRnEdaddy87
      @KoRnEdaddy87 ปีที่แล้ว +1

      Got sorted with your love chat. AVR and Brushes are in the mail. Thanks!

    • @davidstevens7809
      @davidstevens7809 10 หลายเดือนก่อน

      Mine did exactly what yours is..I used 600 grit emery cloth and cleaned the rings that the brushes rub against..after i did that the brushes didnt get hot.and the generator no longer flashed ( pulsed) lights when loaded..

    • @KoRnEdaddy87
      @KoRnEdaddy87 10 หลายเดือนก่อน +1

      I replaced the AVR and brushes with newly supplied ones from champion. It’s still doing the same thing. 🤷🏼‍♂️

  • @leroijr407
    @leroijr407 6 หลายเดือนก่อน +1

    Hi. When testing the Exciter field, if the voltage is in the good range between 4-8 volts AC, what else could be the issue besides the AVR? Could it be a bad circuit breaker? I am only getting 23 volts AC to the circuit breaker line side, and load side. But when I test the circuit breaker while removed from the generator, there is no continuity when switched on for the positive to positive terminal. The negative to negative has full continuity. Edit. When testing the circuit breaker again, now the positive has continuity. Huh. Maybe just a bad voltage regulator? I have champion power generator, model #201035, 10k watt max starting. Which AVR do I order if this is the case? Thank you. Your video makes me stay with getting champion. No one else, not one manufacturer I see helps their customers like you. My generator is only 1 year old from tractor supply. Please help.

    • @ChampionPowerEquipmentHQ
      @ChampionPowerEquipmentHQ  6 หลายเดือนก่อน +1

      We are sorry to hear this. If the voltage range is reading between four & eight volts, then it's the AVR that would need replacing. If you are within the generator's three-year warranty, please give us a call at 1-877-338-0999 or email support@cpeauto.com. Make sure to have the sales receipt handy. If out of warranty, the AVR is item 75 on page five in the owner's manual: www.championpowerequipment.com/wp-content/uploads/2021/01/201035-EPL-English-all.pdf

    • @leroijr407
      @leroijr407 6 หลายเดือนก่อน +1

      ​@@ChampionPowerEquipmentHQ is the outer slip ring supposed to have the white lead, and the inner slip ring have the red? When connected that way, it gets the 38v you do in the test, which is above the 15v required you said. My generator has someone place them on the opposite ways. They put red on the inner ring on the white lead, and outer on the red lead. Which way is correct? And would that destroy the AVR? Possibly fry it? Thank you.

  • @newlifemarine1476
    @newlifemarine1476 ปีที่แล้ว +2

    Interesting. My rotor is reading approx 900 ohms across the slip rings - any idea where to go from here? Thanks

    • @ChampionPowerEquipmentHQ
      @ChampionPowerEquipmentHQ  ปีที่แล้ว

      We're sorry to hear this! At your earliest convenience, please give us a call at 1-877-338-0999 or email us at support@cpeauto.com. 👍

    • @newlifemarine1476
      @newlifemarine1476 ปีที่แล้ว

      @@ChampionPowerEquipmentHQ hi guys - I replace the AVR and brushes and now the generator works perfectly. I think the brushes were ok, I just replaced them as one was shorter than the other.
      I think the main problem was a blown AVR. All good now :)

  • @RaleighWood901
    @RaleighWood901 7 หลายเดือนก่อน

    I have spark on the white wire and Intelligauge shows 120V, but only getting 79V to the plug. Any Ideas? Thanks

    • @ChampionPowerEquipmentHQ
      @ChampionPowerEquipmentHQ  7 หลายเดือนก่อน

      We are sorry to hear this. At your earliest convenience, please give us a call at 1-877-338-0999 or email us at support@cpeauto.com. Thank you.

  • @jamesmnoblesjr9062
    @jamesmnoblesjr9062 9 หลายเดือนก่อน

    Where can I buy a Champion 4500 generator rotor?????

    • @ChampionPowerEquipmentHQ
      @ChampionPowerEquipmentHQ  9 หลายเดือนก่อน

      To place an order for a new rotor, please give us a call at 1-877-338-0999 or visit our online parts store: shop.championpowerequipment.com/en-us/

  • @nasrulsherul2059
    @nasrulsherul2059 3 หลายเดือนก่อน

    Hi. My generator show nominal voltage between 220-240v. But when i plug in an equipment, my equipment show sign like it has low voltage. Can u explain why?

    • @ChampionPowerEquipmentHQ
      @ChampionPowerEquipmentHQ  3 หลายเดือนก่อน

      We are sorry to hear this. Please perform the electrical output testing procedure & call 1-877-338-0999 or email support@cpeauto.com with the results. This will help us verify the issue completely. help.championpowerequipment.com/article/YRqK59KpFU-electrical-output-testing-procedure

  • @TheSamplebridge
    @TheSamplebridge 4 หลายเดือนก่อน

    I have a 100165 and I get 250K ohms at slip rings. This means the rotor is bad?

    • @ChampionPowerEquipmentHQ
      @ChampionPowerEquipmentHQ  4 หลายเดือนก่อน

      We are sorry to hear that. We will need to verify your ohms reading because 250k is extremely high. We will also need you to provide the remaining results, so we can ensure that only the rotor is bad. Before concluding that the issue lies with the rotor, please call us at 1-877-338-0999 or email your results to support@cpeauto.com. This will allow us to assess your unit more accurately. Thank you for your patience.

  • @davidstevens7809
    @davidstevens7809 10 หลายเดือนก่อน

    I have spark at the brushes but no ac output from generator..

    • @ChampionPowerEquipmentHQ
      @ChampionPowerEquipmentHQ  10 หลายเดือนก่อน

      We are sorry to hear this. We recommend next testing the rotor. For further assistance, please give us a call at 1-877-338-0999 or email us at support@cpeauto.com. Thank you.

    • @davidstevens7809
      @davidstevens7809 10 หลายเดือนก่อน

      @@ChampionPowerEquipmentHQ I found the problem.. corrosion / compromised brush lead in wire was heated and dropped voltage possibly. I also unplugged the harness from avr and sprayed wd-40 in connectors..and plugged them back in . made sure the brush spade connector was tight..started it and its charging..by the way I have 49 ohms on rotor..so thats good. THANKS FOR YOUR VIDEOS.

  • @olegsmolinets169
    @olegsmolinets169 ปีที่แล้ว

    Mine shows 1 when connecting to the copper rings, am I doing something wrong ?

    • @ChampionPowerEquipmentHQ
      @ChampionPowerEquipmentHQ  ปีที่แล้ว

      At your earliest convenience, please email us a photo showing one to the copper to support@cpeauto.com, so we may help to verify if there are any issues. 🙂

  • @jamesmnoblesjr9062
    @jamesmnoblesjr9062 9 หลายเดือนก่อน

    A very good video. However showing 38 v on the 13v test doesn’t help

    • @ChampionPowerEquipmentHQ
      @ChampionPowerEquipmentHQ  9 หลายเดือนก่อน

      Sorry about that. If you require assistance performing this procedure, please give us a call at 1-877-338-0999 or email support@cpeauto.com. Thank you.

    • @leroijr407
      @leroijr407 6 หลายเดือนก่อน

      They show 38v. Under 15v is bad. So 38v is good. Mine is 43v.

  • @tcellison1998
    @tcellison1998 ปีที่แล้ว +1

    So what do you do when all of theses tests check out fine but your still not putting out power?

    • @ChampionPowerEquipmentHQ
      @ChampionPowerEquipmentHQ  ปีที่แล้ว

      We would then need to have an authorized repair center do a more internal diagnosis of the machine to pinpoint the likely cause. 👍🏽

    • @dukeman7595
      @dukeman7595 ปีที่แล้ว +1

      You need to 'FLASH' (re magnetize the unit). When they sit for a period of time they lose their magnetic charge. Google the process, it will show the steps you need to take. Very simple process, only takes a couple of minutes.

    • @tcellison1998
      @tcellison1998 ปีที่แล้ว

      @ChampionPowerEquipmentHQ sad thing is is my generator is only about 18 months old with maybe 50 hours on it. It's of course still under warranty and northern tool the people that your people sent me to have had my generator for 4 months and won't fix the piece of shit

  • @AhmadAhmadshah-xx5rf
    @AhmadAhmadshah-xx5rf 8 หลายเดือนก่อน

    Sir..i changer avr but still no power..

    • @ChampionPowerEquipmentHQ
      @ChampionPowerEquipmentHQ  8 หลายเดือนก่อน

      We are sorry to hear this. We highly recommend performing the other tests in this procedure to help identify the root of the problem. When that is completed, please give us a call at 1-877-338-0999 or email support@cpeauto.com. Thank you.