    TECHNICAL PARAMETERS
    Rated Power (kW) GM10500IETC 8.5(GAS.)/8.0(LPG)/6.8(NG)
    Max. Power (kW) 10.5(GAS.)/9.5(LPG)/8.4(NG)
    Engine Model 460i
    Valve Clearance Input valve: 0. 10-0. 15 mm,
    Output valve: 0. 15~0.20 mm
    Stroke × Bore (mm) 92×69
    Engine Type 4-stroke
    Displacement (cc) 458
    Gas Distribution Mode OHV
    Cooling Mode Forced cooling Air
    Rated Speed (RPM) 3600
    Starting Method Recoil start/Electrical start/Remote start
    Fuel Tank Volume (gal) 6.9(26L)
    Fuel Type and Grade unleaded gasoline
    Lubricating Oil Capacity (gal) 0.3(1L)
    Lubricating Oil Model SAE 10W/30
    Noise dB (at 7m)(25% load) 62db
    Rated Voltage (V) 120/240
    Rated Frequency (Hz) 60
    Rated Power Factor 1
    Phase Number single phase
    Run Time @ 25% (h) 14
    Fuel Consumption Rate (25% load (L/h) 2.195
    Fuel Consumption Rate (100% load)(L/h) 5.9
    LPG Consumption Rate (25% load (kg/h) 1.65
    LPG Consumption Rate (100% load(kg/h) 3.43
    NG Consumption Rate (25% load)(m’ /h) 1.296
    NG Consumption Rate (100% load)(m? /h) 3.27
    THD 3%
    Overall Dimension (in.) 30.9×22.6×29.3(785×575×745mm)
    Net Weight (Ib.) 247(112kg)

ความคิดเห็น • 259

  • @GH-wt7ww
    @GH-wt7ww 4 หลายเดือนก่อน +19

    Its Monday 5/20/24 and I'm watching this again because of the power outages going on now . I like your idea if you ever move you take it with you. The whole home back up generator business is going to boom in Houston and I will not pay those high prices. This is a great alternative but I'm concerned of the long term reliability of the genny. Thanks Gavin for your videos and hope you got power.

    • @GeneratorReviews
      @GeneratorReviews  4 หลายเดือนก่อน +6

      Thanks for watching and subscribing, we finally got power back

    • @keletienne7947
      @keletienne7947 2 หลายเดือนก่อน

      I have the Genmax9000ied - got me thru the derecho and now Beryl running my whole home (including central air). With a soft start on your a/c and the setup like Gavin does so you can just plug into your house and switch it to run it all, its the way to go if you live here. Am upgrading to this one though to be able to run off natural gas. For the money, think it will get you thru a few years, when the next greatest thing is available.

  • @michaeldezelar6264
    @michaeldezelar6264 ปีที่แล้ว +10

    This is a great machine. I got mine on Friday!
    I did learn, though, that while they kindly include a 120v style plug (NEMA 5-15P) as a ground-neutral bonding plug, the GFCIs on the generator don't really like it and will trip, which cuts off the neutral path and breaks the bond (I was running it stand-alone not connected to my inlet and this generator is floating neutral). My fix, since I'm not using the 50 amp outlet and that outlet is not GFCI protected, was to take the 50 amp plug that they include and made it into a ground-neutral bond. Problem solved!

    • @normangarrett1033
      @normangarrett1033 ปีที่แล้ว +3

      Yes, I don't think you can use bonding plugs on GFCI outlets, so your solution is great. If one is using the 50 amp plug, you could use the 30 amp for the bonding plug as well. Of course, the bonding plug just lets you use the outlets like a worksite machine, so it's not something you would be using while the unit is plugged into your house.

  • @rscutub
    @rscutub 3 หลายเดือนก่อน +1

    Thank you so much. I was looking for inverter generator tri-fuel to power my 5-ton AC and your video has everything that i needed. Even the AC LRA. Perfect.

  • @patrickcoleman5867
    @patrickcoleman5867 ปีที่แล้ว +3

    I really love the table cover you made for your Generator. If you see the shed i made for my Westinghouse 28000 Generator you would think i had my own power plant running my house i really over did it. i wish i saw this first.

  • @garden-queen2393
    @garden-queen2393 ปีที่แล้ว +3

    Great video of the New 10500 inverter generator. Can’t wait to see what else it can do in the load tests. 👍

  • @rocketj7449
    @rocketj7449 2 หลายเดือนก่อน +1

    That Genmax sounds just as good as my Kohler! Nice product.

  • @stevesmith1291
    @stevesmith1291 10 หลายเดือนก่อน +2

    Nice review. Just grabbed this bad boy on an Amazon lighting sale for $2465 (15% off). Can’t wait to get it and fire it up.

    • @yvonnecates511
      @yvonnecates511 2 หลายเดือนก่อน

      How was your delivery? Go smooth?

  • @thesistersofbollocks
    @thesistersofbollocks ปีที่แล้ว +1

    Intelligente Lösung mit dem Tisch, Danke!

  • @steveddavis
    @steveddavis ปีที่แล้ว +1

    Tri-Fuel is such a great way to go!

  • @mackware5889
    @mackware5889 ปีที่แล้ว +2

    All of your videos and reviews are extremely helpful. Thank you!

  • @ChatGPT1111
    @ChatGPT1111 ปีที่แล้ว +2

    Love these trifuel inverter gennys. This one has a lot of great features. I will probably get one to back up my 2 year old 22kw Generac whole-house since it is not very reliable.

    • @ClintEastonz
      @ClintEastonz 11 หลายเดือนก่อน +4

      I gave up on installing a 22kw standby since everyone wants $500 per year to maintain it in the DC Metro area.

    • @KevinNorris-ke5fx
      @KevinNorris-ke5fx 11 หลายเดือนก่อน +3

      Wow really they don't talk about that

  • @KevinNorris-ke5fx
    @KevinNorris-ke5fx 11 หลายเดือนก่อน +2

    Just joined young man love The load test I have a 30 amp class c I me own the 3400 champion quiet inverter and the 2300 duel feul max pro love them both

  • @ginginthing
    @ginginthing 4 ชั่วโมงที่ผ่านมา

    Great review. I've been looking at which generator to get for a few years. Recently found out the benefits of the inverter gens. And yes, the soft start is a must have even without the need for a gen. And natural gas is also the way I want to go. Perfect setup. U covered it all in a great video. The only concern I have is the warranty on this gen. Parts? I also want to find out how to bypass the CO sensor which is not only a weak point in these inverter gens, but while they are connected, you can enclose these units in a properly vented sound shield box.

  • @JaromMcallister
    @JaromMcallister ปีที่แล้ว +1

    That is a sturdy-looking table.

  • @mwahlert
    @mwahlert ปีที่แล้ว +3

    A wireless display (or smart phone app) to monitor power utilization, fuel level, and better yet, a way to toggle smart idle on and off, would all be awesome and welcomed features!
    I installed a magnetic drain plug and magnetic dipstick in my Predator 9500. Genmax should include them from the factory as another bonus feature. (Or preferably switch to pressurized lubrication and an oil filter, but I’m asking for a lot.)

    • @GeneratorReviews
      @GeneratorReviews  ปีที่แล้ว +1

      I don’t think it’s asking for a lot. It’s just the price increase would also have to be excepted

  • @steveknick1978
    @steveknick1978 ปีที่แล้ว +4

    DuroMax just dropped a 16kW dual fuel inverter for $5000 today. Price is too high but they moved the bar. XP16000iH

    • @GeneratorReviews
      @GeneratorReviews  ปีที่แล้ว +3

      Yes, I should have it on the channel soon

    • @mbecker163
      @mbecker163 ปีที่แล้ว +5

      I saw that but for a little more, you could buy two of these and run them in parallel. Plus (for me) this is a tri fuel and I plan on using NG. Also, I just spoke with Gavin and he confirmed the two units running in parallel will be running a lot quite that this one.

  • @Steven-gv1ke
    @Steven-gv1ke ปีที่แล้ว +7

    The "ultimate" generator is a diesel generator that runs at 1800 rpms, but has been converted to run on natural gas. I'm currently looking at a 14.5k watts for $8,700. The system is rated for 30,000 hours before it needs to be overhauled. They also have a 21k version for $10,000. It uses very little fuel compared to a 3600 rpm generator. You can directly plumb it into your home's natural gas supply and have unlimited fuel.

    • @mwahlert
      @mwahlert ปีที่แล้ว +1

      Everyone has a different definition of “ultimate”. I agree that a diesel 1800rpm machine makes for an excellent permanently installed standby generator, but you can’t easily pick that up and take it with you. These higher capacity portable inverter units are so versatile.

    • @mandharbag6162
      @mandharbag6162 ปีที่แล้ว

      ​bnnnnn

    • @fb510m
      @fb510m ปีที่แล้ว

      You would be also hard pressed to pick up this 247 pound beast and take it w you… id like to see how folks put this in the back of the truck? Lets do a vid on this please…Gavin this sounds loud?

    • @Moondoggy1941
      @Moondoggy1941 2 หลายเดือนก่อน

      What is the name of the diesel generator and can you purchase it in the US?

    • @donm3844
      @donm3844 12 วันที่ผ่านมา

      ​@fb510m I have a similar model that's 13k ,I see no reason to transport my home generator to different locations, It's just for my home ,so if you want something to take to different locations , get a smaller model possibly, Mine has wheels and I have a small 12 foot trailer with a drop down ramp, if I did want to transport it, that isn't a problem and can be loaded in 2 minutes,I feel a generator is a tool that you use a limited number of times in 5 years, so just having it available to run your heat, ac ,refrigerator and freezer in case of emergency, That is the main thing ,it's just to get you by till power is back, we had a tornado come thru 2 years ago, we had no power for a week, my portable generator powered my entire home for 1 week until we got power back, we ran it from 6 am till 9 pm daily, then went to bed and it was fine, From 9 until 6 am ,we plugged our refrigerator and freezer into a bluetti inverter battery in the evenings when the gas generator was off and this system worked great while others had nothing for a week in our area, All I can say is for the 1 time or 2 you may need a generator every few years , the money is well spent .

  • @ACommenterOnYouTube
    @ACommenterOnYouTube 26 วันที่ผ่านมา +2

    11:25
    What you should do is cut the NG off 1st and let it stall out, then power the generator down.

  • @Skippy145
    @Skippy145 ปีที่แล้ว

    Thanks for this genmax video. What a great machine!!!

  • @athenanimbuss6826
    @athenanimbuss6826 ปีที่แล้ว

    Gavin, thank you for another awesome video/review! 👍🙏❤️

  • @brianh2497
    @brianh2497 ปีที่แล้ว

    Love the table, great video as always!

  • @khiaraslaw
    @khiaraslaw ปีที่แล้ว +2

    nice unit very quiet

  • @hwrk777
    @hwrk777 หลายเดือนก่อน +1

    This GENMAX is a twin to the PULSAR PGD105TISCO - 10500W TRI FUEL INVERTER GENERATOR

  • @toddgiumenti5380
    @toddgiumenti5380 ปีที่แล้ว +2

    You do amazing unbiased videos, but I have to ask. What is your go to reliable generator that you use for your RV and home?

    • @GeneratorReviews
      @GeneratorReviews  ปีที่แล้ว +1

      This is the generator I use for my home but for my RV I use the genmax 7250 W

  • @RayLacks
    @RayLacks 4 หลายเดือนก่อน +1

    looks good but who services this unit? I like to keep with Honda because everyone works on them

  • @gscharles
    @gscharles ปีที่แล้ว

    I just bought my GM9000ied two months barely 😢 wish I could get this one.

    • @simplecyberclub
      @simplecyberclub 10 หลายเดือนก่อน

      Just buy another and parallel them and get more power. Great to have a backup if one goes down too. 😊

  • @donaldbeal6953
    @donaldbeal6953 ปีที่แล้ว +3

    What is the manufacturer's recommended maximum continuous runtime on natural gas

  • @ACommenterOnYouTube
    @ACommenterOnYouTube 26 วันที่ผ่านมา +1

    6:12
    Wrong .... those 22kW home stand by are about $6k .... plus install which is $500 ....
    This unit is about $2500 which is a little bit less than half
    But yes this one you can move and take to the next home where the other one is a somewhat "permanent" install.

  • @chelo3510
    @chelo3510 2 หลายเดือนก่อน +1

    Great video! Can you provide link for soft start you used?
    Also been seeing a lot about floating neutral vs bonded. Did you have to change generator to floating neutral since you’re connected to your house panel?
    If you want to use the generator for potable use do you have to bonded it again?

    • @GeneratorReviews
      @GeneratorReviews  2 หลายเดือนก่อน +1

      This generator is floating neutral no need for conversion
      Micro air EasyStart

    • @chelo3510
      @chelo3510 2 หลายเดือนก่อน

      Good to know! Thank you.

  • @88KeysOnFire
    @88KeysOnFire 3 หลายเดือนก่อน

    Assuming you have enough battery capacity to last for several days, if a secondary dedicated solar recharge panel array failed to charge the batteries, the generator would be the solution for automatic failover to recharge them. At that a lower capacity generator.

  • @willg6997
    @willg6997 วันที่ผ่านมา

    I think I saw somewhere that Genmax was making an EFI model upgrade to this. What would be the advantage and disadvantage of EFI vs Carb version?

  • @BrianAckley
    @BrianAckley 2 วันที่ผ่านมา

    Can you do a review on the A-Ipower GXS7600iRD

  • @donhgr
    @donhgr 10 หลายเดือนก่อน +2

    During natural disasters they cut natural gas a lot of times because of fires so that’s really not as dependable as propane in my opinion. I’ve worked for the utility company over 40 years and absolutely have propane stored for my emergency use.

    • @GeneratorReviews
      @GeneratorReviews  10 หลายเดือนก่อน

      Agreed 👍🏾

    • @davidlemay4761
      @davidlemay4761 5 หลายเดือนก่อน

      Just use gasoline propane is just to expensive.

    • @MartinD9999
      @MartinD9999 5 หลายเดือนก่อน

      You’re claiming propane is more expensive than gasoline🤨 How much is gasoline in your area?

    • @Moondoggy1941
      @Moondoggy1941 2 หลายเดือนก่อน

      I have never heard of them shutting off NG prior to or during a disaster.

  • @samanthadykes6090
    @samanthadykes6090 ปีที่แล้ว +2

    Am i correct in understanding the only items running other than the central AC was the refrigerator and 2 ceiling fans?

    • @mbecker163
      @mbecker163 ปีที่แล้ว +1

      Good question

  • @TheModelmaker123
    @TheModelmaker123 ปีที่แล้ว +1

    Love your generator reviews. Can you compare the Genmax to the Predator 9500 in terms of sound levels, maintenance accessibility, performance? What size gas hoses and do you have a link?

    • @GeneratorReviews
      @GeneratorReviews  ปีที่แล้ว +3

      Links in the description and yes I will do that video for you 👍🏾

  • @BarryBianculli
    @BarryBianculli ปีที่แล้ว +1

    Hey Gavin - a bit off topic here, but have you seen the new Duromax XP16000iH? Looking forward to your test on that beast!

    • @GeneratorReviews
      @GeneratorReviews  ปีที่แล้ว

      Yessir, I have and ones coming my way from Duromax for reviewing

  • @stevesmith1291
    @stevesmith1291 11 หลายเดือนก่อน

    Have you made a video yet on the proper break in steps/procedures that you recommend for these generators?

    • @GeneratorReviews
      @GeneratorReviews  11 หลายเดือนก่อน

      Not yet but I’ll will be making one soon

  • @ACommenterOnYouTube
    @ACommenterOnYouTube 26 วันที่ผ่านมา +1

    Let me correct you on your Generator:
    Its NOT 10.5kW on NG ... as you keep stating.
    Its 8400W starting and 6800W running on NG ...
    You were at 5700W with that 5 ton AC which means you were at 83% capacity. If you were to run the microwave or stove or dryer while the ac was ON, you would blow that breaker on the generator.

  • @TheSnakeman3
    @TheSnakeman3 ปีที่แล้ว +2

    What are the inrush amps on your AC now with the soft start?
    I’ve got a large standard generator, but I need to get a large inverter one. Maybe next year. I will be sure to buy it from you.

    • @Krautastic
      @Krautastic 9 หลายเดือนก่อน +2

      On my 3.5ton heat pump/ac I went from over 100amps of locked rotor rating (I never actually measured starting amps before) to 25amps with a microair easystart. Not only is it a much better ball park for a generator, my utility bills went down and lights don't dim when it comes on which was a problem in certain rooms, usually those with dimmer switches.

  • @joshgomez5263
    @joshgomez5263 2 หลายเดือนก่อน

    Interested in the soft starter for the compressor
    Also I have a 5000 watt genny on NG running whole house with 2 freezer 1 full size refrigerator 1 smaller
    Can use heating but won’t handle Ac
    So this genny with with the soft starter would be awesome
    Next what is the difference between the 13000 watt reg vs the 10000 inverter

    • @GeneratorReviews
      @GeneratorReviews  2 หลายเดือนก่อน

      Also, this one is an inverter pure sine wave so you get less than 3% THD clean power so you want to harm any of your sensitive electronics and appliances

  • @Andrew-vt7mi
    @Andrew-vt7mi 2 หลายเดือนก่อน

    Hey Gavin, I just bought the Pulsar version of this generator, trying to run a 4 ton Carrier AC unit with a soft start on natural gas, just like you.
    Unfortunately, mine won’t start it! It actually wouldn’t even start a 3.5 ton unit while it was on low idle mode.
    The only difference I can see between your setup and mine is that I am using the 30A outlet, not 50A. My old Champion 100520 could start that AC on 30A, so I expected the Pulsar could too. I’m not tripping any breakers on the house or the generator, so I can’t really process through why I would need a 50 amp instead of a 30 amp, but again it’s the only difference I see from where you were able to do this successfully.
    Am I wrong? Do I need a 50A inlet for the pulsar to kick on the AC with the soft start?

    • @GeneratorReviews
      @GeneratorReviews  2 หลายเดือนก่อน

      Try a 50amp inlet with 6 gauge wire and you will be able to get your unit running plus what soft start are you using

  • @jkim412
    @jkim412 4 หลายเดือนก่อน

    Positive Comment!!!

  • @lambert6473
    @lambert6473 ปีที่แล้ว

    Yes sir

  • @melvinhanson3659
    @melvinhanson3659 8 หลายเดือนก่อน

    Can you use the 30amp plug on the generator to connect the house or its best to use the 50amp? As always great video plug

    • @GeneratorReviews
      @GeneratorReviews  8 หลายเดือนก่อน

      Yes, you can use your 30 amp plug to connect to a 30 amp inlet.

  • @greglewis1332
    @greglewis1332 10 หลายเดือนก่อน

    What would be your choice between the Genmax 10500 TriFuel or a Pulsar 9500 Dual Fuel Inverter Generator? It will be used on a bbq concession trailer with a 50 AMP plug. It has a Pioneer mini split but needs an additional A/C installed on top.

    • @GeneratorReviews
      @GeneratorReviews  10 หลายเดือนก่อน +1

      Hey Greg
      Thanks for the email looking forward to hearing from you

  • @TwinStarGenny
    @TwinStarGenny 4 หลายเดือนก่อน

    Can you please focus/report on long term reliability & testing? Parts availability and reliability.

    • @TwinStarGenny
      @TwinStarGenny 4 หลายเดือนก่อน

      Meant to say ease of repair on last word.

    • @GeneratorReviews
      @GeneratorReviews  4 หลายเดือนก่อน

      th-cam.com/video/qof2INa7Q2w/w-d-xo.htmlsi=ftKIaw9as9qH9hcg

  • @hooznxt04
    @hooznxt04 ปีที่แล้ว

    Been looking at the Genmax brand but only a 1 yr warranty has kept me from completing the purchase.

    • @GeneratorReviews
      @GeneratorReviews  ปีที่แล้ว +1

      Genmax stands behind the warranty. You shouldn’t have to worry about anything.

  • @amelsfr
    @amelsfr ปีที่แล้ว +1

    very good, but nobody talks on how to have it run when it's flooding... where do you put it? even stand-by generators are usually installed on the ground, which doesn't make any sense

    • @fb510m
      @fb510m ปีที่แล้ว +1

      Free wooden pallets

    • @GeneratorReviews
      @GeneratorReviews  ปีที่แล้ว +1

      I guess in case of flood I’m putting mine on top of its cover. Thanks for that great idea honestly, I never thought of it.

    • @amelsfr
      @amelsfr ปีที่แล้ว +1

      @@GeneratorReviews I know... it seems nobody thinks about that, but to me, that's the main concern...

    • @ChatGPT1111
      @ChatGPT1111 ปีที่แล้ว

      Thanks for showing your soft start system. I think my electrician pulled a fast one on me. My soft starts on both A/C units have no external boxes at all. They took my money though.

    • @classicjay7786
      @classicjay7786 ปีที่แล้ว

      @@ChatGPT1111it also be installed internally not all of them install on the outside. Depends on how old and model of your AC

  • @jidic1845
    @jidic1845 2 หลายเดือนก่อน +1

    I don't believe this unit can run a whole house. Its producing maybe 40 Amps. I may be wrong but when the HVAC is running then the fridge compressor fires up, your finished.

    • @GeneratorReviews
      @GeneratorReviews  2 หลายเดือนก่อน +2

      We just had a tornado last month and a hurricane this month I lost power for six days both times I ran my 5 ton AC, three ceiling fans, refrigerator, lights, and microwave the entire time.
      I have customers who did it for 18 days straight with no power.

  • @2ndAmendProtector
    @2ndAmendProtector วันที่ผ่านมา

    Gavin. Thanks for all the vids. With a 5-ton A/C with Micro Air Flex Soft Start, after this Genmax 10500 gets up and running, will I be able to run my two standard sized refridgerators also? What will happen when the A/C turns off and then later on turns on again? Will I just leave my two fridges plugged in and running and it will start the A/C without an issue?

    • @GeneratorReviews
      @GeneratorReviews  วันที่ผ่านมา

      Yes, you will be able to do that with no issues👍🏾

    • @2ndAmendProtector
      @2ndAmendProtector วันที่ผ่านมา

      @@GeneratorReviews Gavin. I located these two Inverter generators, which would you choose for my set up? Same price for both, shipping is free for both. $2,500
      Genmac GM11000iET 11,000/8500 ratings......or.....DuroMax XP11000iH 11000/9000 ratings.........................thanks.

    • @2ndAmendProtector
      @2ndAmendProtector 22 ชั่วโมงที่ผ่านมา

      Oh....I forgot. I have a 28kw tankless water heater. Will either of those generators be able to handle that, with the A/C running, as long as we only use one shower or one faucet at a time while using the generator?

  • @dj5752
    @dj5752 9 หลายเดือนก่อน

    Great video. What size wire did you run from your outlet box to I guess your double pole 50 amp breaker in the panel. Thanks

  • @paxrom1
    @paxrom1 4 หลายเดือนก่อน

    I just bought the sam's club model

  • @lowriderssux
    @lowriderssux ปีที่แล้ว

    Gavin, do you know when the larger V twin Genmax inverter generator will be hitting the market? I am getting ready to pull the trigger on a Westinghouse Wgen12000dfc but really like these Genmax generators. Hopfully the Vtwin version will have a spin on oil filter.

  • @iembalm3328
    @iembalm3328 7 หลายเดือนก่อน

    Great video. Will this run a 50 amp fifth wheel with 2 15,000 btu A/C units? What would the run time be? Thanks

    • @GeneratorReviews
      @GeneratorReviews  7 หลายเดือนก่อน

      You’ll probably get about 24 hours per tank but it would run absolutely everything in that RV

  • @JaredCarter84
    @JaredCarter84 ปีที่แล้ว

    Nice

  • @raymondyunker9962
    @raymondyunker9962 ปีที่แล้ว

    Thanks for the great content. I will have a similar issue of NG and electric far apart like you. Please provide a link for that 50’ NG hose. What length is the NG hose that comes with the generator? Can they be connected to each other for additional length if needed?

    • @GeneratorReviews
      @GeneratorReviews  ปีที่แล้ว

      Hi
      The hose is 25ft and I will post the links to my website

    • @robgilbert1946
      @robgilbert1946 ปีที่แล้ว

      @@GeneratorReviews couldn't find it on your website. Is it 1/2 or 3/4"?

  • @MrSkunks
    @MrSkunks ปีที่แล้ว

    New pulsar 4000 DF generator video! It’s hard to believe what they get out of a 47 pound machine. Also dedicating a segment to run times, testing things like propane and gas run times, eco mode vs no eco mode, same wattage inverter vs standard generator, different load types and how they affect run time, oil additives that claim to increase mpg, etc etc

  • @nm12300
    @nm12300 11 หลายเดือนก่อน

    Hello Gavin. Can you do a parallel 10,000 and the 9,500 to charge a Tesla and see how long it takes to charge it with those two generators together pushing all that power. I’m thinking it will hopefully be like plugging it to a super charging station.

    • @GeneratorReviews
      @GeneratorReviews  11 หลายเดือนก่อน

      Check out this video. It’s almost what you’re asking for.
      th-cam.com/video/9c_YJ4jhB2g/w-d-xo.htmlsi=xP5ST3CYiOxUz6KP

  • @rjakeyno9065
    @rjakeyno9065 2 หลายเดือนก่อน

    how hard/heavy is it to move the generator from one place to another? Iam concerned about the weight and the noise level. Thank you.

    • @GeneratorReviews
      @GeneratorReviews  2 หลายเดือนก่อน +1

      It is very easy to move it around thanks for the handleand the wheels

  • @TexanSince1828
    @TexanSince1828 หลายเดือนก่อน

    Can you parallel 2 of these generators on Natural gas to use as a whole home unit on a 2500 square foot house.

  • @johncarr123
    @johncarr123 5 หลายเดือนก่อน

    I guess it does not matter how long your natural gas hose is from the source to the generator?

    • @GeneratorReviews
      @GeneratorReviews  5 หลายเดือนก่อน

      I would try and keep it under 100ft if at all possible.

    • @johncarr123
      @johncarr123 5 หลายเดือนก่อน

      @@GeneratorReviews Great, I ordered a 40 ft hose

  • @johncarr123
    @johncarr123 ปีที่แล้ว +1

    Were did you purchase your custom NG line?

  • @MS-tu2lm
    @MS-tu2lm ปีที่แล้ว

    Good

  • @MorCoutureMenswear
    @MorCoutureMenswear 11 หลายเดือนก่อน

    Are you going to review the Pulsar 9500W Tri Fuel Gasoline Propane Natural Gas Portable Inverter Generator ?

    • @GeneratorReviews
      @GeneratorReviews  11 หลายเดือนก่อน +1

      I’m currently getting all the tri fuel to do a comparison video. Thanks for asking. Should be doing it soon.

  • @onlywenilaugh6589
    @onlywenilaugh6589 ปีที่แล้ว

    The noise level shot up quite a bit pulling just about 6 amps it seemed on the camera audio at least.

  • @antcentral
    @antcentral 2 หลายเดือนก่อน

    Can you show us your gas meter? is it upgraded?

    • @GeneratorReviews
      @GeneratorReviews  2 หลายเดือนก่อน

      No, my gas meter is not upgraded

  • @jbhobbyist9372
    @jbhobbyist9372 23 วันที่ผ่านมา

    How big is the natural gas meter that your Genmax is running off of. If I buy this generator I want to make sure my meter and piping will handle it.

    • @GeneratorReviews
      @GeneratorReviews  22 วันที่ผ่านมา

      Half-inch line 35,000 BTU

    • @jbhobbyist9372
      @jbhobbyist9372 22 วันที่ผ่านมา

      @@GeneratorReviews How big is the GAS METER on your HOUSE that feeds the generator? What is the C.F.H and the PSI on the METER?

  • @bdkbdk8005
    @bdkbdk8005 2 หลายเดือนก่อน

    Anyone know what the reliability is on the Genmax? Overall on Amazon most have lower reviews than other brands.

  • @johnnyhotrod
    @johnnyhotrod ปีที่แล้ว

    Any long term reliability on these engines?Do we know if we can reliably get a few thousand hours on these?Thanks

    • @GeneratorReviews
      @GeneratorReviews  ปีที่แล้ว

      I currently have around 20 of them running on food trucks 8 to 10 hours a day so far they’re doing great. Haven’t seen any issues on running them that hard.

    • @johnnyhotrod
      @johnnyhotrod ปีที่แล้ว

      @@GeneratorReviews Awesome to know,thanks for the reply.I need a backup for my backup,gonna try one of these.

  • @hoserack2
    @hoserack2 ปีที่แล้ว +1

    Gavin, can you do the same video paralleling a 9000 IEU unit on gasoline? I have the 9000 unit on your recommendation from your videos. I am now getting the 10,500 Tri-Gas and connecting it to my gas line here at the house. I wonder how well paralleling the 9000 would work? Would I be able to run both of my AC units and everything else in the house?

    • @GeneratorReviews
      @GeneratorReviews  ปีที่แล้ว +1

      As long as you have soft starts and paralleling two generators you should be able to do it

  • @fb510m
    @fb510m ปีที่แล้ว

    Sorry G; what are the dimensions of the table. That table is a great design!! Thanks

  • @AdamFeldman42
    @AdamFeldman42 ปีที่แล้ว

    Is the fuel selector a solenoid or motorized ball valve? I read about the solenoid failing on similar models.

  • @philipjacobson7094
    @philipjacobson7094 2 หลายเดือนก่อน

    Gavin, I have a 4 ton unit with same softstart. My house is about 1900 sq ft. Will it be able to run whole house easily? I have a westinghouse 9500 gas and its no problem.

    • @GeneratorReviews
      @GeneratorReviews  2 หลายเดือนก่อน

      Yes, my AC is a 5 ton

    • @philipjacobson7094
      @philipjacobson7094 2 หลายเดือนก่อน

      @@GeneratorReviews thanks for the fast respoinse. And is the generator not truly 50amp? I keep seeing mixed answers on this.

    • @philipjacobson7094
      @philipjacobson7094 2 หลายเดือนก่อน

      @@GeneratorReviews Also I meant on natural gas.

  • @danielschrall5400
    @danielschrall5400 วันที่ผ่านมา

    Is this generator floating neutral or bonded?

    • @GeneratorReviews
      @GeneratorReviews  วันที่ผ่านมา

      This generator is a floating neutral

    • @GeneratorReviews
      @GeneratorReviews  วันที่ผ่านมา

      generator-superstore.com/product/genmax-gm10500ietc-tri-fuel-portable-inverter-generator/

  • @garynickel648
    @garynickel648 11 หลายเดือนก่อน

    Please tell me how long is the warranty, and do they have extended warranty? If I order it from you do I go to you for warranty, if needs be?

    • @GeneratorReviews
      @GeneratorReviews  11 หลายเดือนก่อน

      The warranty is a one-year warranty. If you have any concerns, you can call me or you can call Genmax direct I don’t have extended warranty and honestly I don’t think it’s needed.
      If you have any concerns, you can call me right now. I’ll be happy to help.

    • @garynickel648
      @garynickel648 11 หลายเดือนก่อน

      Thanks for the reply, can you please send the phone number to Genmax and customer support.

  • @ACommenterOnYouTube
    @ACommenterOnYouTube 26 วันที่ผ่านมา +1

    7:50
    2 ceiling fans are about 100 watts LOL ... thats nothing to a 10kW generator LOL

  • @mosescastillo1371
    @mosescastillo1371 2 หลายเดือนก่อน

    Can you just turn off your natural gas at the connection from your home first. Then let the generator use up all the gas in the 50ft hose till it shuts off on its own??

    • @GeneratorReviews
      @GeneratorReviews  2 หลายเดือนก่อน

      Yes, that’s the best way to do it

  • @jbhobbyist9372
    @jbhobbyist9372 27 วันที่ผ่านมา

    How much natural gas does it need to run?

  • @ebonyjackson3198
    @ebonyjackson3198 2 หลายเดือนก่อน

    I know this video is over a year old, but what kind of automatic transfer switch is compatible with this generator?

    • @GeneratorReviews
      @GeneratorReviews  2 หลายเดือนก่อน

      I have yet to find one that works with the seven pin ATS

  • @gymtanningduty
    @gymtanningduty ปีที่แล้ว

    What size natural gas line do you run from house to generator ?

  • @oscardominguez5786
    @oscardominguez5786 4 หลายเดือนก่อน

    Did the AC unite work with 10500 watts generator everybody show videos but I don't see they turn on the AC unite to test they only turn the lights and ceiling fans but don show the AC compressor runing

    • @GeneratorReviews
      @GeneratorReviews  4 หลายเดือนก่อน

      Check out the videos at 9.49

  • @wfodavid
    @wfodavid 4 หลายเดือนก่อน

    Can you suggest an ATS that will cut on/off generator automatically and work with the Genmax ATS cable.

    • @GeneratorReviews
      @GeneratorReviews  4 หลายเดือนก่อน

      Genmax is still in the process of developing this ATS unit

  • @purplerose9041
    @purplerose9041 2 หลายเดือนก่อน

    What was the installation cost to get this going?

    • @GeneratorReviews
      @GeneratorReviews  2 หลายเดือนก่อน

      Parts and labor usually start around 800

  • @lentaylor4528
    @lentaylor4528 10 หลายเดือนก่อน

    Gavin not a question about the 10500iETC but on the Genmax 6000. I takes for ever to start on propane. Should I install a purge button in line and would that help. I don't like having to add gas just to start the generator then switch to propane.

    • @GeneratorReviews
      @GeneratorReviews  10 หลายเดือนก่อน

      You could purge the line before tightening it all the way, but at least the unit will try again automatically.

  • @NurseAcrobat
    @NurseAcrobat 9 หลายเดือนก่อน

    I haven't seen this issue mentioned much so maybe it's a non-issue, but I'm wondering if people have problems running a heat pump with their generator when the heat pump enters a defrost cycle. Since connecting my air handler to an emporia energy monitor I've realized that my air handler jumps from 500 watts to 10kw for a couple minutes every couple hours, likely running heat strips during a defrost cycle.
    The rest of the time my whole house including the 3 ton heat pump uses under 7kw. I'm left wondering if even after installing an easy start I'll need to find a way to disable the aux heat for defrost cycles, or if I should just plan on using space heaters unless I get a 2nd 10500iETC to parallel.

    • @GeneratorReviews
      @GeneratorReviews  9 หลายเดือนก่อน +1

      It’s most likely exactly like you said your heat strips are coming online requiring a higher demand. Is there anyway you can deactivate that?

    • @NurseAcrobat
      @NurseAcrobat 9 หลายเดือนก่อน

      @@GeneratorReviews From what I've read so far, heat strips in the air handler can be either triggered by the thermostat for aux/emergency heat or by heat pump itself for maintaining comfort when the heat pump goes into defrost mode and basically switches to ac mode blowing cold air for a couple minutes.
      Nothing I do at the thermostat can prevent the communication coming from the heat pump for heat strips to come on during defrost so the advice I've seen is to disconnect the W wire from the low voltage junction box at the heat pump, with it making no difference in the defrost performance, just the comfort of anyone near the hvac vents while defrost occurs. I'm hoping it would work to install an inline low voltage switch somewhere between the heat pump and the air handler so that I can just disable the heat strips when needing to use generator power vs needing to open the panel and insert/remove a wire if/when I want to change it.
      All of this is odd because I didn't even think the air handler had heat strips since the paperwork I received with the house listed heat strips as an option that wasn't selected and even on days when the temperature has been below 20F my whole house energy use has rarely topped 7kw per hour, so it was a surprise to see energy use for the air handler alone bump up to 10kw. The frequency and duration matches when I should expect defrost to occur. The air handler and heat strips must share a circuit as there is only one cable going to it, rated at 60 amps/240 volts, on a 90 amp subpanel running nothing else. The large gauge wiring had been reused from the prior system so I had thought it was simply funny to have a 500 watt fan on a 90 amp dedicated panel. The heat pump is on a separate 40 amp circuit on the main panel.

    • @NurseAcrobat
      @NurseAcrobat 9 หลายเดือนก่อน

      @@GeneratorReviews I unhooked and capped the white low voltage thermostat wire from the heat pump defrost board and now defrost runs fine without triggering the heat strips. I haven't noticed any discomfort from the heat strips not running. It would be easy to reconnect if desired.

    • @projectswithjw
      @projectswithjw 8 หลายเดือนก่อน

      Heat strips typically have a dedicated breaker in the panel. Find that and turn off. Defrost will blow cold air while heat strips are disabled but will be fine as long as the compressor can still generate heat with the outdoor temperatures. Some compressors are disabled in negative temps and heat strips become primary in that situation. Then it would be better to throw the compressor breaker off and run strips in emergency heat mode.

    • @NurseAcrobat
      @NurseAcrobat 8 หลายเดือนก่อน

      @@projectswithjw A separate circuit would be helpful. My air handler apparently shares a 60 amp circuit with the heat strips. My heat pump manual has heat efficiency data down to -5F. It's only twice as efficient as resistance heat at 10F but it rarely gets below 15F here in NC.

  • @ericmartinez5051
    @ericmartinez5051 2 หลายเดือนก่อน

    Can you run a generator with NatGas with more than 60% load for days in an outage?
    If NatGas running watts total is 6800 and the load in the video with a/c and a few fans/lights is 5900, then that is 88% load and does not much room for refrigerator, tv, or etc.
    Am i mistaken?

    • @GeneratorReviews
      @GeneratorReviews  2 หลายเดือนก่อน

      Yes, you can. That’s actually the perfect percentage.

  • @vertigo_one
    @vertigo_one 2 หลายเดือนก่อน

    What is the NG size here? 3/4? 1/2?

  • @tszczyrek28
    @tszczyrek28 ปีที่แล้ว

    How warranty work on that one. If I buy extended one where is should go if something happens to it ?

    • @GeneratorReviews
      @GeneratorReviews  ปีที่แล้ว

      You would contact the manufacturer and set up a warranty service

  • @nharri100
    @nharri100 หลายเดือนก่อน

    Can I run it on natural gas and keep it inside garage

    • @GeneratorReviews
      @GeneratorReviews  หลายเดือนก่อน

      No!!! You cannot have the generator inside of the garage

  • @patgavin1232
    @patgavin1232 5 วันที่ผ่านมา

    How long of an NG hose come with a unit?

  • @Randy-vk7pj
    @Randy-vk7pj 8 หลายเดือนก่อน

    Gavin, can you parallel the Genmax GM 10500 with the genmax 4000 inverter generators together?

    • @GeneratorReviews
      @GeneratorReviews  8 หลายเดือนก่อน

      Unfortunately, No you can’t because the 4000 is 120 V inverter and the 10,500 is a 240 V inverter they’re not compatible to parallel

  • @leguirerj
    @leguirerj ปีที่แล้ว

    My natural gas connection is about 50 ft from my 50 amp inlet box. What is the inner diameter of your natural gas hose?

    • @michaeldezelar6264
      @michaeldezelar6264 ปีที่แล้ว +1

      The provided hose is half-inch with half-inch quick connect fittings.

    • @GeneratorReviews
      @GeneratorReviews  ปีที่แล้ว +1

      Mine is about 75 feet are used 50 feet of holes and 25 feet of power cable and it worked just fine

  • @dragally1
    @dragally1 ปีที่แล้ว +4

    I like your videos but I have to say, these Genmax gens are a piece of junk. I've had my 6000i for just a year and now its out of time and Genmax wont help with either fixing it or helping me find someone to fix it. Genmax AND Westinghouse are CHIT!

    • @GeneratorReviews
      @GeneratorReviews  ปีที่แล้ว +1

      Sorry for the bad experience

    • @dragally1
      @dragally1 ปีที่แล้ว +2

      I had to throw it away as they refused to honor the warranty, and nobody works on them. Thanks for encouraging me to spend my hard earned money on this junk.

    • @toneycopen
      @toneycopen 2 หลายเดือนก่อน +1

      I have a brand new westinghouse 12000DF that took a dump on me after 12 hours. Complete garbage.

    • @Killa_Grizz
      @Killa_Grizz 4 วันที่ผ่านมา

      @@dragally1victim mentality

  • @aholmes6612
    @aholmes6612 8 หลายเดือนก่อน

    Does it auto switch from 120/240 or is it manual switch?

    • @GeneratorReviews
      @GeneratorReviews  8 หลายเดือนก่อน +1

      If you keep the switch in 120/240 you can run both loads

  • @chauhankp1
    @chauhankp1 2 หลายเดือนก่อน

    How much gas does it consume? Can you share some data?

    • @GeneratorReviews
      @GeneratorReviews  2 หลายเดือนก่อน

      With a 6.9 gallons fuel capacity, it can operate for around 8.1 hours at 50% load with a full tank of gasoline (fuel consumption around 0.85 GPH). When using propane, it can run for around 4 hours (estimation based on a 20 lbs tank - propane consumption around 1.18 GPH).

  • @DanielDaniel-eu9yq
    @DanielDaniel-eu9yq ปีที่แล้ว +1

    This unit is very noisy idled at 70 dB. It would need to be enclosed and soundproofed... in cold climates it needs to be sheltered anyway to protect it from the snow.

  • @marklauritsen6782
    @marklauritsen6782 ปีที่แล้ว

    Should an inverter generator be able run indefinitely at 80% of its rated output? My new Genmax 9000 trips its overload breaker after running at 5700 Watts for about 5 minutes. Is that normal?

    • @GeneratorReviews
      @GeneratorReviews  ปีที่แล้ว

      Something is overloading did you turn off your water heater? Make sure you turn off all the circuits that’s not being used

  • @whatsthedileo
    @whatsthedileo ปีที่แล้ว

    Did it come with that 50 foot NG hose?

  • @chelo3510
    @chelo3510 หลายเดือนก่อน

    Can someone explain the low idle function? Will the generator adjust to more power if needed while low idle is on or does it have to be off?

    • @GeneratorReviews
      @GeneratorReviews  หลายเดือนก่อน +1

      Eco mode or low idle will adjust automatically as load is increased. It helps with fuel economy.

    • @chelo3510
      @chelo3510 หลายเดือนก่อน

      @@GeneratorReviews thank you!!

  • @gymtanningduty
    @gymtanningduty ปีที่แล้ว

    Do you think I could run a 4 ton central AC 109 LRA with a soft start and two refrigerators with this on NG?

    • @GeneratorReviews
      @GeneratorReviews  ปีที่แล้ว +1

      Yes with the soft start I think it will work 👍🏾

    • @gymtanningduty
      @gymtanningduty ปีที่แล้ว