Repairing a 20 Year Old Rheem Heat Pump!

แชร์
ฝัง
  • เผยแพร่เมื่อ 5 พ.ย. 2024

ความคิดเห็น • 262

  • @andreeriner811
    @andreeriner811 หลายเดือนก่อน +1

    I used to have the best little vacuum pump. I love that thing. It was small and lightweight. Did not kill myself caring it along with everything else. It finally blew up on me one day I miss that thing.

  • @alandahlstrom7213
    @alandahlstrom7213 2 หลายเดือนก่อน +3

    In all my years of HVACR one unmistakable truth is, no one is more critical of a service tech than another service tech. There is sometimes more than one right way to do a job properly and I have to say that after watching a few of your videos, I like the way you do things. Nothing made me happier than when you cleaned out those leaves and washed the coil. So many techs would not have bothered cleaning out that debris and it is this attention to detail that sets you apart.

    • @a.v.3726
      @a.v.3726 2 หลายเดือนก่อน +1

      Way to go the extra mile, the mark of a good technician 👍🏼

    • @StevenBowron
      @StevenBowron 2 หลายเดือนก่อน

      @@alandahlstrom7213 the job being done is no better than the person doing that job, no matter what fanciful company they call out to fix the problem

  • @billyk5107
    @billyk5107 5 หลายเดือนก่อน +37

    I was at a job yesterday and the guy told my customer he needed new equipment he couldn’t get the unit to run . He had wired the capacitor wrong and when I turned, the unit on the fan was running backwards I rewired the capacitor the right way, and the unit came on and is running fine. No need for new equipment ya baby

    • @joshcade918
      @joshcade918 5 หลายเดือนก่อน +2

      No parts required!

    • @1985230ce
      @1985230ce 4 หลายเดือนก่อน +1

      Probably did it on purpose so he could sell a new unit.

    • @billyk5107
      @billyk5107 4 หลายเดือนก่อน

      @@1985230ce yeah right I wouldn’t doubt it

    • @adamrspears1981
      @adamrspears1981 2 หลายเดือนก่อน +2

      If a unit is out of warranty, I give my customer both options & let them decide how to spend their money:
      For this price, I can repair it.
      For this price, I can replace it.
      Which one do you want to do?

  • @robalexander7348
    @robalexander7348 5 หลายเดือนก่อน +8

    Nice repair Curtis, this will keep it running for a few more years 👍 Au

    • @HVACGUY
      @HVACGUY  5 หลายเดือนก่อน +3

      Hope so

  • @dperreno
    @dperreno 5 หลายเดือนก่อน +6

    Glad to see that you were able to patch that up and get it running again.

  • @andreeriner811
    @andreeriner811 หลายเดือนก่อน +1

    Everybody’s different but I always bend a couple of inches on my solder when I’m going around the bottom of a fitting. I’ve just always done that.

  • @staind288
    @staind288 5 หลายเดือนก่อน +5

    I'm so happy that you did this for the customer.

  • @stevencossaboon3237
    @stevencossaboon3237 5 หลายเดือนก่อน +8

    Nice work Curtis. Another one brought back.

    • @HVACGUY
      @HVACGUY  5 หลายเดือนก่อน +2

      Thanks

  • @props-model-shop
    @props-model-shop 5 หลายเดือนก่อน +21

    I have had mutiple Rheem units lasting over 35 years. They were built like tanks back in the day.

    • @STho205
      @STho205 5 หลายเดือนก่อน

      Not this one. This model is a lemon.

    • @joshcade918
      @joshcade918 5 หลายเดือนก่อน +2

      @@STho205 Yup nailed it on the head... Only been over 20 yrs running... Replaced the caps and had to repair a line that rubbed against another component. If my eyes don't know what a lemon looks like, they sure do now!

    • @STho205
      @STho205 5 หลายเดือนก่อน +3

      you don't know how often this thing has been repaired. I had one on a property that had to be repaired every 2 to 3 years for it's life. It chewed through capacitors regularly, overdrew power, loud as hell even when new, burned out a blower fan twice, the top fan once....and the coil lines also wiggled and rubbed on each other causing leaks that got brazed and refilled three times.
      Being a Pkg unit it is hard to replace with anything better as only a couple of companies make them...and then brand names get riveted on. Most Pkg units are crap built for old mobile homes, school portables and construction trailers
      To put in a competitive traditional unit a complete re-ducting gut job is needed to the house...as well as finding an air closet for the inside handler. This is why people keep patching it. The $6000 duct work atop a new $4000 unit.
      As to this job, He's awfully high as it is a 1 yr patch....but he was really trying to sell one of 2 or 3 new unit quotes (likely over $8000 each). The $2000 repair was to nudge him. However he didn't have the cash or will to drop another $10k on this aging house....so he got it repaired and agreed to the quote
      If someone tells you they'll pay $2000, few AC companies say ..ahhh kidding, it's just $500

    • @STho205
      @STho205 5 หลายเดือนก่อน +1

      @@joshcade918 if good multizone mini splits existed 40 to 25 years ago, then these underhouse bad duct units should have never been installed in old houses that didn't have ducts originally.

    • @glennschlorf1285
      @glennschlorf1285 4 หลายเดือนก่อน

      @@STho205 its still crooked way to manipulate

  • @jthonn
    @jthonn 5 หลายเดือนก่อน +26

    I didn't think that was going to happen. I guess it is still cheaper than a new install, if it holds up for a while. Nice work

    • @HVACGUY
      @HVACGUY  5 หลายเดือนก่อน +3

      Thanks

  • @rcf8367
    @rcf8367 5 หลายเดือนก่อน +6

    Great job keeping that running Curtis!

  • @lazyjack8081
    @lazyjack8081 5 หลายเดือนก่อน +10

    Tough place to braze. Had an old hand back in day tell me "Solder down and braze up". Took me a few time to get the hang of it, but way better . You get the hidden part done first, before eyes are watering from the brazing fumes.

  • @TxGuitarPlayer
    @TxGuitarPlayer 5 หลายเดือนก่อน +9

    Best tools in the business. Sure enjoy watching you. I almost try to climb through my screen to help sometimes lol😅. Especially on those self tapping screws mounting those capacitor straps 😂

    • @billybobosullivan7084
      @billybobosullivan7084 5 หลายเดือนก่อน +1

      me too. I had to jump forward a couple of minutes during that. I couldn't look, it was too painful.

  • @danburch9989
    @danburch9989 5 หลายเดือนก่อน +14

    Other than the compressor, evap & condenser coils and motors, I can't see the need to replace an entire unit just because it's 20 years old unless parts aren't available. I would have to budget $100/mo to cover the cost of two heat pump units for my home. Probably a little more to account for 15 years of inflation. In my previous home, I paid $3000 for a roof top heat pump. I never had it serviced. To maintain the 10 year warranty, I had to have it serviced 2x/yr (cooling & heating seasons). I didn't have it serviced. That saved me $50 x2 per year on service costs. It finally failed in its 11th year. Cost of repair $495. My current home with two heat pumps needed 2 motors and two capacitors over the 20 years we've been living in the homo. Annual service would not have prevented those failures. I keep the filters changed and the coils clean.

  • @gpowerdragon9852
    @gpowerdragon9852 หลายเดือนก่อน

    20 years old and Still no rust man the Paint is really Quality 👌

  • @OcRefrig
    @OcRefrig 5 หลายเดือนก่อน +6

    Good video ! Rheem units - nothing better !!! curtis - anything under 299 is ok on old r-22 systems remember head was 30 over in those days.

  • @DWNTWN-iu8vf
    @DWNTWN-iu8vf 5 หลายเดือนก่อน +9

    I gotta say that you really keep your tools & equipment well organized!

  • @kelvinandrewssr9194
    @kelvinandrewssr9194 4 หลายเดือนก่อน +5

    As a residential roofer over 33 yrs , yes the price exactly right. When we disturb or move these old units causing damage to the lines.

  • @danobrien3109
    @danobrien3109 5 หลายเดือนก่อน +6

    Nice save on an old unit Curtis.👍👍🇨🇦

    • @HVACGUY
      @HVACGUY  5 หลายเดือนก่อน +1

      Thanks 👍

    • @thepoopsoup
      @thepoopsoup 5 หลายเดือนก่อน

      New units cost less than 1/2 on energy cost to run

  • @mikephillips8648
    @mikephillips8648 3 หลายเดือนก่อน +1

    I have no idea why I like this channel but I do !

  • @billsimpson604
    @billsimpson604 5 หลายเดือนก่อน +7

    I've been running a 4 ton R22 unit without a dryer for 12 years. Worse, the people who installed the new condenser unit never evacuated the system. They just blew some nitrogen through it and charged it with R22. I expect failure any day, so I got one of those portable AC units, so I don't die waiting to get it replaced when it does go out. I noticed that it wasn't level, but decided that trying to level it after years of running the scroll compressor like that might mess it up, or crack the copper lines going into the brick wall. So I left it alone, remembering the saying, 'If it ain't broke, don't fix it'.
    Once the capacitor running the fan motor failed while I was cutting the grass. The motor got so hot that it boiled off the water when I first tried to hose it down. That was about 6 years ago, and the motor is still running. It was made in India. They made a good motor !

    • @SkilledLabor
      @SkilledLabor 5 หลายเดือนก่อน

      They most likely sweeped it with R-22 instead of pulling a vacuum.

  • @frarob6139
    @frarob6139 5 หลายเดือนก่อน +9

    A voiceover explaining what you are doing, kind of gases being turned on and off, etc would give you a wider audience for your videos. You do a great job having the camera pointed at what you are doing.

    • @pogonomyrmexrugosus6240
      @pogonomyrmexrugosus6240 4 หลายเดือนก่อน +3

      This isn't supposed to be a tutorial. You do a great job at bitching about content you're not paying for.

  • @kg4muc
    @kg4muc 5 หลายเดือนก่อน +4

    Great job on the fix!!

    • @HVACGUY
      @HVACGUY  5 หลายเดือนก่อน +1

      Thanks 👍

  • @abtechgroup
    @abtechgroup 2 หลายเดือนก่อน

    The bottom of the meter is a bar graph representation of the numbers (the 4 blocks on the left side are the Negative side - the 3 blocks on the right are the Positive side) - and it has 3 different views 1) the 10 second average of the change in pressure per minute; left side blocks are filled would be decreasing; right side blocks filled would be increasing; and no blocks filled means no change. 2) the non averaged real time change. 3) graphical view of the measurement - all blocks on is no vacuum - all blocks off is lowest possible vacuum. These 3 views are selected in rotation with the "next" button. Fieldpiece is a great little tool. Love your videos

  • @woodystokes1543
    @woodystokes1543 5 หลายเดือนก่อน +3

    Tech tip for the hoses appion makes a plastic threaded piece that will keep it clean.

  • @ricardocastaneda4541
    @ricardocastaneda4541 5 หลายเดือนก่อน +1

    Idk if anybody else has mentioned it but I appreciate the fact that your always changing/improving your work bags etc , I’ve been disliking my Victor tote & been looking for an alternative , ima give what your using a try.
    Awesome videos , I enjoy watching on my lunch break sometimes 🔥

  • @panamacitybeachbum
    @panamacitybeachbum 5 หลายเดือนก่อน +38

    Sweating in a drier that close to the TXV can be detrimental. Applying heat sink gel, or wrapping the TXV with a wet rag just makes sense.

    • @Mapdotgolf
      @Mapdotgolf 5 หลายเดือนก่อน +3

      Yeah crazy how much heat he got and brazing like that next to txv 🤣

    • @Harold-si7eh
      @Harold-si7eh 5 หลายเดือนก่อน +3

      Brush on and heat sodder gel get where you can not see!

    • @jamesbaker429
      @jamesbaker429 4 หลายเดือนก่อน

      You could see that rad covered in dried grass so a third of cooling compromised taking off the covers and doing it properly is another job adding to bill ,service seems to have been ignored on this old installation,hence it's cost them more to run then if service had been done.

    • @Eric-696
      @Eric-696 4 หลายเดือนก่อน

      Man that thing was dirty!!!😅

  • @moshemoshe-yy8hj
    @moshemoshe-yy8hj 5 หลายเดือนก่อน +6

    Very funny everybody has an opinion you doing the right job keep giving it an option

  • @AaronPowellvox
    @AaronPowellvox 5 หลายเดือนก่อน +8

    Now they have at least 2 degrees less cooling capacity. I just hate those replacements but they are necessary for jobs just like this. The cost of R22 would not have made sense to use. Great work as usual.

    • @justincrafton6105
      @justincrafton6105 5 หลายเดือนก่อน +4

      For what he charged to repair that unit, he should have put R22 instead of R438a. If I'm not mistaken, the repair quote was $2000 ! Way overcharged for that repair, in my opinion !

    • @joshcade918
      @joshcade918 5 หลายเดือนก่อน +2

      @@justincrafton6105 Not sure if it is in my area... A new neighbor thought they got a wonderful deal on an entire replacement of their HVAC system, ductwork and all, for 20k. Their current system was functioning too... But apparently they decided to shop around and replace everything anyway after moving in. Fascinating, isn't it.

  • @abcdefghi2175
    @abcdefghi2175 5 หลายเดือนก่อน +4

    curtis please wear gloves you know what they say neglected infected disconnected LOVE YOUR VIDEOS

    • @joshcade918
      @joshcade918 5 หลายเดือนก่อน

      What?

  • @stephenhubbinett1287
    @stephenhubbinett1287 5 หลายเดือนก่อน +4

    great job

    • @HVACGUY
      @HVACGUY  5 หลายเดือนก่อน +1

      Thanks

  • @thesilentonevictor
    @thesilentonevictor 5 หลายเดือนก่อน +4

    Great job under this situation just want to know could you not find any other location to place the dryer and the discharged line

  • @franciscotejeda1461
    @franciscotejeda1461 5 หลายเดือนก่อน +3

    Good video Mr Curtis

    • @HVACGUY
      @HVACGUY  5 หลายเดือนก่อน +1

      Thanks

  • @alejandromata825
    @alejandromata825 2 หลายเดือนก่อน

    I had a very, very small stress fracture on a compressor’s piping in a condenser split system on a roof that I just couldn’t pin point and had to use dye like a goober and then drape a bunch of drop cloths over it like a really hot Indian sweat lodge to make it dark enough to see the dye. Lost so much water that day I had to deal with leg cramps at night.

  • @orinmangar2333
    @orinmangar2333 5 หลายเดือนก่อน +7

    Sometimes it is nice to bring the old unit back to life. They r built like tanks.

  • @shermanmaddoxrcpc774
    @shermanmaddoxrcpc774 5 หลายเดือนก่อน +3

    0:58 I guessed a jbweld fix. Of course I could be wrong 😂

  • @browntigerus
    @browntigerus 5 หลายเดือนก่อน +1

    That is very sweet nitro regulator.. Good job in a very tough spots.

  • @edtruax7721
    @edtruax7721 4 หลายเดือนก่อน

    Enjoyed watching!

  • @brianward2250
    @brianward2250 5 หลายเดือนก่อน +1

    I did like the video. Nice work man.

  • @michaelhancock9098
    @michaelhancock9098 4 หลายเดือนก่อน

    Your knowledge is impressive

  • @tkonzl6059
    @tkonzl6059 5 หลายเดือนก่อน +1

    I realize that the leaking areas need to be cleaned, but are there particles getting into the pipes? If so, do they need to be cleaned out? If so, how does this happen?

  • @FrankCastle-he8fl
    @FrankCastle-he8fl 2 หลายเดือนก่อน

    My I suggest a shop vac for cleaning up all the debris and not catching anything on fire when you are brazing

  • @darongilliam3585
    @darongilliam3585 5 หลายเดือนก่อน +6

    Why didn't you use a two-way filter made for a heat pump?

  • @jasonwood7340
    @jasonwood7340 2 หลายเดือนก่อน +1

    I liked your video, you may want to double check your acetylene regulator pressure. In the red ain't good.

  • @badger305
    @badger305 2 หลายเดือนก่อน

    Who makes the carry case for your oxy acetelyne tanks and hoses? It looks like some type of canvas tote.

  • @Alex-kv8zy
    @Alex-kv8zy 5 หลายเดือนก่อน +2

    do you wear shaded glasses for brazing? should i as someone new in the field

    • @bobward7489
      @bobward7489 3 หลายเดือนก่อน

      Yes, nothing super dark, the darkness of regular sunglasses does the trick

  • @JustinMiales
    @JustinMiales 3 หลายเดือนก่อน

    We used to buy these Rayovac pool heaters now Rheem bought them out, is there a good units to mice don't get in there and show all the wiring up but they just need to be cleaned every season, diesel gas heaters for swimming pools not the heat pumps.

  • @NoahbHvac
    @NoahbHvac 5 หลายเดือนก่อน +3

    Just worked on the same unit but had an audibly leaking evap. Customer wants to replace it…

  • @ThomasWalker-m2y
    @ThomasWalker-m2y 5 หลายเดือนก่อน +1

    Another Great repair under
    your belt and bucks in your pockets.
    Repair made by the GEORGIA EXPERT OF HVAC.

  • @jamminwrenches860
    @jamminwrenches860 5 หลายเดือนก่อน +11

    Positive pressure when sanding. That hole was big enough for debris to enter the system.

    • @markbeiser
      @markbeiser 5 หลายเดือนก่อน +1

      He set up his nitrogen purge before he started sanding.

    • @doorguru168888
      @doorguru168888 19 วันที่ผ่านมา

      @@markbeiser Don't confuse the expert. I wonder if he even watched the whole video.

  • @christopherdelon3026
    @christopherdelon3026 5 หลายเดือนก่อน +3

    So that unit come from the factory without a filter dryer?

    • @HVACGUY
      @HVACGUY  5 หลายเดือนก่อน +3

      Yes

  • @altechy7304
    @altechy7304 4 หลายเดือนก่อน

    Great job and video as well. What was the last part you installed like you inserted a cylinder in a pipe. Why install it if it wasnt there originally?
    Thanks for sharing with the world

  • @JustinMiales
    @JustinMiales 3 หลายเดือนก่อน

    I know automobile air conditioning is it the same where you have to vacuum purge the unit to get any contaminants out ?

  • @woodystokes1543
    @woodystokes1543 5 หลายเดือนก่อน +1

    Nice 😊 work 😊

  • @butlerstouchHVAC
    @butlerstouchHVAC 5 หลายเดือนก่อน +2

    what tool bag model is that for the torches?

  • @hvachacker586
    @hvachacker586 4 หลายเดือนก่อน

    Whats your subcool (TEV system)? Whats the point of having a four port manifold if your purging refrigerant? Where is your scale? Also installing a biflow drier per most units should be on mixed gas side in heating mode. You now will run her starved on gas in the highest compression ratio mode of that unit. Last please wrap the TEV with a wet rag.

  • @ivanbg5167
    @ivanbg5167 หลายเดือนก่อน

    Why is the dryer pointing the wrong direction in cooling mode? I see you installed a bidirectional dryer.

  • @a.v.3726
    @a.v.3726 2 หลายเดือนก่อน

    He charged for his time, experience, overhead, parts and labor. $2000? In New York, this would have been $5000+. Keep up the good work, brother 👍🏼

  • @jamesstumpff5877
    @jamesstumpff5877 2 หลายเดือนก่อน

    Is he replacing that with R 22 or bluon ?

  • @gregsidel3557
    @gregsidel3557 5 หลายเดือนก่อน

    Great video good job I'd like to know what you did after that head pressure was going up

  • @justincrafton6105
    @justincrafton6105 5 หลายเดือนก่อน +18

    Can someone please explain why this repair cost $2,000 ?

    • @anthonylewis8733
      @anthonylewis8733 5 หลายเดือนก่อน +1

      I’m not an HVAC guy but I assume labor was about 2 or so hours total for about $300, parts of $50 or so and the rest Freon cost. Freon had to be completely refilled and Freon is never cheap.

    • @CarlosTorres-tf6il
      @CarlosTorres-tf6il 5 หลายเดือนก่อน +5

      Finding a leak, welding a leak, vacum and charging the unit. These repairs are not cheap. 2000 is a fair price.

    • @CarlosTorres-tf6il
      @CarlosTorres-tf6il 5 หลายเดือนก่อน +3

      I'm in los angeles California area.
      Most companies will just try to sell you new equipment for $20,000.00 dollars

    • @robertwittenburg6143
      @robertwittenburg6143 4 หลายเดือนก่อน +3

      @@CarlosTorres-tf6il Bullshit. There should be a labor rate per hour and looks like this guy's rate was over $400.00 an hour. R22 replacement refrigerant costs about $30.00 a pound so at most $300.00 for that system. Total ripoff. Ignorance on the homeowners part for agreeing to that price.

    • @glennschlorf1285
      @glennschlorf1285 4 หลายเดือนก่อน

      ​@@robertwittenburg614330 a pound for refrigerant really... R22 has been discontinued its in short supply

  • @johnhovorka3062
    @johnhovorka3062 หลายเดือนก่อน

    Flux around the tubing should have pulled that solder in.

  • @doorguru168888
    @doorguru168888 19 วันที่ผ่านมา

    many from the last video were thinking you should charge $19.95! They have no clue what is involved.

  • @gaoutdoor4372
    @gaoutdoor4372 5 หลายเดือนก่อน +4

    Good job my friend! What camera do you use , video quality very good.

    • @HVACGUY
      @HVACGUY  5 หลายเดือนก่อน +3

      GoPro 12

  • @adamrspears1981
    @adamrspears1981 2 หลายเดือนก่อน

    You might of burned that TXV. I hope you didn't though.
    I recommend using Viper Wet Rags.

  • @philiph1234
    @philiph1234 5 หลายเดือนก่อน +1

    It’ll live a few more years ! What was your torch tip ?

  • @Sattracer
    @Sattracer 5 หลายเดือนก่อน +1

    You do know that you can put some lab grade alcohol in your charging line as you add coolant and it will aid in preventing icing inside a line that has been open to the air and had to be resealed? I've seen that done many times in south Mississippi. It must be pure alcohol, the purest. It prevents the drier from clogging with ice.

    • @1985230ce
      @1985230ce 4 หลายเดือนก่อน

      What kind of alcohol?

    • @Sattracer
      @Sattracer 4 หลายเดือนก่อน

      @@1985230ce 99% Isopropyl Alcohol just fill your hose on the low side and fit back onto your gauges. Open the line and fill with coolant.

  • @Hvacnc
    @Hvacnc 5 หลายเดือนก่อน +4

    I say anything below 1000 microns is good. I was taught 500 in school but when I replaced some trane compressors they would say anything below 1000 is good 🤷‍♂️

  • @frankveronese1290
    @frankveronese1290 5 หลายเดือนก่อน

    Maybe someone knows yesterday on a 7 year ago Lennox had to have the air handler blower motor replaced. The new motor spools up or starts low then goes to full speed. Is this now normal on new motors.

  • @mkl5448
    @mkl5448 4 หลายเดือนก่อน +1

    To everybody complaining about the money, nobody made the customer agree to the repair. He could have shopped it out, got three different estimates, and still went with this guy. Maybe that's the going rate in his area, yes it seems a little pricey, yes I'm not sure I would have put the money into it, but at the end of the day it's not my money. So everybody is simply relaxed and enjoy the work.

  • @dondesnoo1771
    @dondesnoo1771 5 หลายเดือนก่อน +1

    There was a alcohol could be added yrs ago when a dryer was impossible dont know about today legal w new refrigerants

  • @randyprentice9292
    @randyprentice9292 2 หลายเดือนก่อน

    Why would you not change the schrader valves while the system was empty? Those tools are for a fully charged systems. You made it harder than you needed to. And yes that old system will still outlast a brand new one.

  • @fidelgarcia5683
    @fidelgarcia5683 5 หลายเดือนก่อน

    no superheat or subcooling?

  • @garfieldwood8315
    @garfieldwood8315 2 หลายเดือนก่อน

    16:50 WHERE IS YOUR CORDLESS SHOP VAC?

  • @EdwinSemidey
    @EdwinSemidey 4 หลายเดือนก่อน +1

    I never understood why people don't maintain their outside units

  • @DavidJohnson-yd2jw
    @DavidJohnson-yd2jw หลายเดือนก่อน

    After 40 years as an HVAC owner and tech, the biggest killer of any heat pump is Green Slime, when moisture gets into the unit and mixes with the compressor oil due to a refrigerant leak when during low pressure it will allow the sucking in moist air into the unit. This unit will probably die this summer or during next winter. You should have condemned this unit, Next time using a torch near the expansion valve use a wet rag to keep it cool, it does not take too much heat to damage it. You did use a bi-flow filter this was correct. Were you able to check the air filter?

  • @gabrielstern4992
    @gabrielstern4992 5 หลายเดือนก่อน +6

    Nice job Curtis I guess you must put a little more MO 99 in as a replacement for r 22 to compensate for the capacity loss or put the factory amount in first of the mo99 to get the system running then add the amounts of extra mo99 as needed until the pressures and temps read like it did when it had r 22 in it and sweats back properly. While monitering the high and low side pressures.
    Also I hope mo99 is not one of the refrigerants bieng phazed out I know 407 c is and honestly if the custumer wanted to pay extra you could have dumped out the mineral oil and replaced it with poe 32 and put 407 c in it but the again what refrigerant would have made a good replacement for that unless mo 99 can work with poe oil. They just made it too complicated when the switch to 410 a happened when they should have just switched to 407c and instructed hvac techs to dump out the mineral oil and replace with poe and flushed out the linesets and evap coil then vacaum for 40 minutes to remove the residual flush solutions and replace the receiver dryer or filter I see you replace often on the linesets just like when the switch on cars happened in 1994 from r 12 to 134 a and Curtis the instructions on cars were dump out all old mineral oil flush linesets out flush the condenser and evap using nitrogen or compressed air and flush solution until it comes out clear the add Ester oil to compressor and new reciever dryer. Then hook up vacaum out system for 40 minutes then let sit for 20 minutes to make sure it held the vacaum the charge up with r 134 a and those same concepts should have been applied to residential hvac not all this extra mumbo jumbo and use this refrigerant that refrigerant it's about what works. And converting should have been done 15 years ago.
    Not like what's happening now anyway good job as usaul

    • @HVACGUY
      @HVACGUY  5 หลายเดือนก่อน +4

      It almost always takes a little more than factory charge. That’s just a starting point.

    • @gabrielstern4992
      @gabrielstern4992 5 หลายเดือนก่อน +4

      @@HVACGUY thanks Curtis as I am considering maybe studying for hvac and taking the tests just so I can do my own stuff in my condo community. But first I need to finish getting this lyme desease out of my body which could take several months as it had went after my eyesight which is now really starting to come back but also ended up rupturing my ear drum which is still healing and caused a lot of swelling and inflammation in my feet and all over my body. I just wish more techs were like you and took the time to do just do what the custumer needs and wants without pushing constantly new systems on them. As they can't always afford them right away.

    • @gabrielstern4992
      @gabrielstern4992 4 หลายเดือนก่อน

      @@hilljack6765 you were lucky did you use an ester oil charge or a, pag oil charge. But if you converted you should have disconnected the lines removed the compressor dumped compressor oil out and either filled with pag 100 or ester oil.
      Then flushed out the line sets condenser and evaporator and used pressurized air from a compressor to blow until clear. And that's do to possible sludge and debris. That's why you do it that way on a old scholl car the new style car condensers you cannot flush out but they are only around 100 dollars. Maybe it's just me but I don't like cutting corners

    • @gabrielstern4992
      @gabrielstern4992 4 หลายเดือนก่อน

      @@hilljack6765 I know that but you still have to dump out the mineral oil from the compressor and disconnect the lines then do a, system flush then vac for 40 minutes then you can do the charge otherwise it's acid city.

  • @donmarion8808
    @donmarion8808 2 หลายเดือนก่อน

    The customer had the option of getting more bids based on what this gentleman estimated. This is what he accepted. Could he have gotten it cheaper? Maybe, maybe not. You pay for quality. In Arizona, it would have been expensive.

  • @davidca96
    @davidca96 5 หลายเดือนก่อน +6

    Hope that lasts a while for them, sure isnt what id want with a system that old but old stuff was made better so, he may get a lot out of it. Curtis gets paid either way so 😁

  • @garypoplin4599
    @garypoplin4599 5 หลายเดือนก่อน +1

    15:13 - Oooh! _That_ doesn’t sound good!!

  • @mcdonamw
    @mcdonamw หลายเดือนก่อน

    Is this the $2000 repair quoted from last video?

  • @edenmolinar2086
    @edenmolinar2086 5 หลายเดือนก่อน +2

    A portable shop-vac would be handy... and a bud light girl to keep you cool in that hot weather.😁

  • @chuckmayerchak3071
    @chuckmayerchak3071 5 หลายเดือนก่อน +5

    I watch a lot of your videos, yesterday you said it was a 2,000 dollar repair. I'm just trying to figure how you justify that price. Parts and misselanius expendables your cost giving a wide margin for error 400 dollars. 60 percent mark up total 640 dollars service call 175 dollars? 4 hours labor?? Doesn't seem to add up.

    • @Mapdotgolf
      @Mapdotgolf 5 หลายเดือนก่อน +5

      Cause when you run a business you have more thing to pay for. You got van maintenance, gas oil tires, you got insurance for your business and your self. There a lot you don’t understand until you run a business and understand why we charge what we charge.

    • @Mapdotgolf
      @Mapdotgolf 5 หลายเดือนก่อน +2

      If he did that job for 1000 or less. He ain’t make any money.

    • @chuckmayerchak3071
      @chuckmayerchak3071 5 หลายเดือนก่อน +5

      All I know is I was a service Manajer in a Ford dealership for 50 years. If we made 40 % on parts and 150 dollars per hour on labor we were living large!!! And people call dealerships crooks!!! I was in the wrong profession!

    • @Mapdotgolf
      @Mapdotgolf 5 หลายเดือนก่อน +4

      @@chuckmayerchak3071 you sit in ac all day and we’re suit, not much to do selling a car. We work hard in heat and way more then you think. Most people can’t last doing our job

    • @homecraftsolutions3506
      @homecraftsolutions3506 5 หลายเดือนก่อน +4

      3 hours labor at 150/hr is 450. 50 in parts. 200 for freon at most. 50 trip charge. 750 to 1000. you must be a pretty good salesman. I have run a carpentry and a handyman business for the last 10 years and this seems like a rip to me. I know we need to make money but we don't have to make it all on one job.

  • @garfieldwood8315
    @garfieldwood8315 2 หลายเดือนก่อน

    14:40 "I didn't want that to get in the dirt"
    (Gived it a quick puff of air instead of flushing the line out with the bottle)
    15:00 Proceeds to connect line to vacuum pump
    15:15 "Great! Got dirt in it" )Turns vacuum pump on, alliwing dirt to be drawn through the vacuum pump)
    Wonders why his vacuum pump is worn out...

  • @jeremyfogt6798
    @jeremyfogt6798 5 หลายเดือนก่อน +4

    Looked like a bi flow dryer, so why would it only work in cooling mode? I like the fix, for some reason I thought you would cut out and put new pipe in. I guess the nitrogen keeps it from going in the pipe.

  • @jonrod8731
    @jonrod8731 4 หลายเดือนก่อน

    How much of the $2k was profit?

  • @buffalobobbayoushow6040
    @buffalobobbayoushow6040 5 หลายเดือนก่อน +2

    Some times an old evaporator will begin leaking after you pull the system into a vacuum. The coil has been at positive pressures for years and the copper turns can’t take the contraction that the vacuum creates. Make sure the customer understands this can happen when making the decision to repair or replace!

  • @steveprice-n9b
    @steveprice-n9b 4 หลายเดือนก่อน

    NEVER quote what you are charging people on these kind of channels that should be common knowledge by now!

    • @badger305
      @badger305 2 หลายเดือนก่อน

      Why not? Unless you are ashamed of the amount you are gouging people for!

  • @jimdavis6833
    @jimdavis6833 4 หลายเดือนก่อน +1

    Curtis, that's a bi-directiional drier. Sorry, I had to say it.

  • @alfredocuomo1546
    @alfredocuomo1546 3 หลายเดือนก่อน

    So which filler rod do you use BCuP or BAg alloy and why.

  • @churchlj8055
    @churchlj8055 4 หลายเดือนก่อน +1

    You guys complaining about the repair. This refrigerant costs more than gold these days.

  • @peterking1134
    @peterking1134 5 หลายเดือนก่อน +3

    Why did you not use a bi directional filter?

    • @HVACGUY
      @HVACGUY  5 หลายเดือนก่อน +10

      I did

    • @TheFatesLieutenant
      @TheFatesLieutenant 5 หลายเดือนก่อน +6

      Looked like it had a bidirectional arrow on the dryer.

    • @peterking1134
      @peterking1134 5 หลายเดือนก่อน +3

      @@HVACGUY that’s not what I heard in your comments ?

    • @uzlonewolf
      @uzlonewolf 5 หลายเดือนก่อน +4

      @@peterking1134 Normally heat pumps use 2 TXVs, one at the evap and one at the condenser, giving you a line that is always liquid which you can install the filter/dryer in. This unit, however, uses a single TXV that meters in both directions. This means for one direction (cool, in this case) the filer/dryer is going to be on the wrong side of the TXV and thus is going to see a mix of liquid and vapor instead of just liquid.

  • @davidwaite3420
    @davidwaite3420 2 หลายเดือนก่อน

    Just remember that he is not setting the price his company is!!

  • @Always1fisherman
    @Always1fisherman 2 หลายเดือนก่อน

    It would have been nice if the debris had been cleaned out.

  • @randyjennings9853
    @randyjennings9853 4 หลายเดือนก่อน

    I believe R22 is over a hundred dollars a pound.

  • @StevenBowron
    @StevenBowron 2 หลายเดือนก่อน

    Was that the 2000 dollar zip tye

  • @JimJr1962
    @JimJr1962 4 หลายเดือนก่อน +24

    I never make negative comments but this $2000 repair gives new meaning to the old phase Highway Robbery.

    • @TheMongoose69
      @TheMongoose69 4 หลายเดือนก่อน +7

      It's only highway robbery when you don't know what you do and you're charging people and exorbitant amount for doing crappy work if you're trained and perfect at what you do or at least close you're charging for your knowledge not the hours

    • @Lividash
      @Lividash 4 หลายเดือนก่อน +4

      he qouted a fix and a replacement. this is what they went with. customers choice here, no highway robbery.

    • @hoktang1
      @hoktang1 4 หลายเดือนก่อน +2

      You have to take into consideration that unit used r22. R22 runs at 150 to 200 a pound. Depends on how many pounds he has to replace. That is most of the cost of the repair. I think atleast 1400 of the bill is for the r22. Or they could have went with newer models to have a cheaper refrigerant in uses.

    • @gregdouglas5405
      @gregdouglas5405 4 หลายเดือนก่อน +1

      Why would it cost 2000 to braise this.

    • @hwesson75
      @hwesson75 4 หลายเดือนก่อน +1

      @@hoktang1 He used r438a, not r22. That's more like $20/lb.

  • @henryduke722
    @henryduke722 4 หลายเดือนก่อน

    He should have clean all the pine needles out

  • @jeffkablock3229
    @jeffkablock3229 5 หลายเดือนก่อน +1

    man you need to use a number 2# tip and 7/11 on your oxg and cet

    • @philiph1234
      @philiph1234 5 หลายเดือนก่อน

      What is his torch tip?

  • @ChrisHall02
    @ChrisHall02 3 หลายเดือนก่อน

    $2,000 - easy, $450 of R22 marked up to $900, because he has to buy it, and keep it on his truck and eat any losses. 2 service calls, run capacitor, 4-5 hours of time, materials fees for things like solder, zip ties, screws, gas, etc. And, enough profit to pay for the truck, insurance, health, dental, income, sales and medicare/SS taxes if he's self-employed, and the cost of a potential callback, and then savings for retirement because no pension or 401k. The fastest way to go broke as a contractor is to charge too little for a job. This guy knows how to run a profitable business.