For 19ft Span - Size of Footing , Column and Beam Reinforcement Details

แชร์
ฝัง
  • เผยแพร่เมื่อ 21 มิ.ย. 2021

ความคิดเห็น • 80

  • @truedecors5941
    @truedecors5941 2 ปีที่แล้ว +1

    Super explanation direct to core content

  • @venu511
    @venu511 2 ปีที่แล้ว +1

    Good video sir..more information 👌👌👌👌

  • @bollusrinivas
    @bollusrinivas 3 ปีที่แล้ว +4

    Column size 9/15 with 6 Rods(16mm 4bars and 12mm 2bars with 8mm rings @6inch) and distance between two columns is 15.8feet. two rooms, each 12feet/15.8feet. Footing 6.5feet depth width 4x4, with 1feet 40mm and 2.5feet 20mm. Is this good for g+2 residential building?

  • @identidem
    @identidem 2 ปีที่แล้ว

    Thanks a lot o was looking for this for a long time but didn't find much info.
    The span I have is 22 ft.
    Columns 9*14inches, 4 bars16mm and 2 bars 12 mm door/lintel beam is 6inches and the roof beam is 12 inches deep 16mm bars. Will it be sufficient?

  • @nsubugadeo7256
    @nsubugadeo7256 11 หลายเดือนก่อน +2

    Nice lecturer🎉

  • @anilshukla8075
    @anilshukla8075 2 ปีที่แล้ว +1

    Excellent knowledge

  • @ameehasa5504
    @ameehasa5504 3 ปีที่แล้ว

    How many crank bar we should use? I hope if u have video for framing on all type of soil

  • @pradeepSuriyabandara
    @pradeepSuriyabandara ปีที่แล้ว

    Thanks for the lesson what about if this G + 2 story with 5 ton of load

  • @KusaasiraNoah7421
    @KusaasiraNoah7421 2 ปีที่แล้ว

    can you use 16mm diameter bars in columns and 20mm in beams?

  • @murthyau6620
    @murthyau6620 3 ปีที่แล้ว +3

    Can we know from you, the load bearing of our existing Residential structure, to go for further floors, at professional consultation. Then how to communicate, please. Regards.

  • @kennethwhite5158
    @kennethwhite5158 2 ปีที่แล้ว

    Sir, If we have four steel rods on the bottom of the beam and three steel rods in the column to tie off to how is it possible to tie the two middle rods in the beam to one middle rod in the column? I'm confused.

  • @ph6263
    @ph6263 3 ปีที่แล้ว +1

    Sir My newly constructed house have one of the beam of length of 5.2 m (16.5 ft) and one secondary beam is tested on it. It is 230×300mm but we used 4 no of steel bars of 16 mm at bottom and 2 nos of 16 mm + 1 no of 12 mm at top.
    So ll it sustain to that amount of load for longer period or developed crack???
    As I see many engineers recommend more than 450 mm deep beam.

  • @dreamer69223
    @dreamer69223 2 ปีที่แล้ว

    Is 12mm 5 bars, 16 mm 1 bar enough For 14 feet beam ( top 3 - 12mm, bottom 2 - 12mm and 1- 16 mm)??

  • @mohammadmuslim5694
    @mohammadmuslim5694 2 ปีที่แล้ว +1

    Good lecture

  • @syedabdulquddus3469
    @syedabdulquddus3469 2 ปีที่แล้ว

    supper sir, Thank you very much

  • @engrraufkhan9876
    @engrraufkhan9876 3 ปีที่แล้ว +7

    Nice lecture,sir Explain Difference between Tie beam and plinth beam

  • @fasterfaster5960
    @fasterfaster5960 3 ปีที่แล้ว

    Baraka lahou fikkk

  • @faruqahmedbusiness1105
    @faruqahmedbusiness1105 3 ปีที่แล้ว +1

    Will you show the analysis. Formula or thumb rule for column and footing design like beam depth formula l/20 for depth.

  • @hemantasingh8606
    @hemantasingh8606 3 ปีที่แล้ว +2

    6 nos of 16mm in beam (10X12) for 20 feet span.column (12x12) 4 nos 16mm &4 nos 12mm for single room .can we build g+2?

    • @kswvidioyoutube8816
      @kswvidioyoutube8816 3 ปีที่แล้ว

      It's possible even I'm doing my own house with four 16 mm andtwo 12 mm in one biller size is 8/10

  • @ariezaziziacahlebih2637
    @ariezaziziacahlebih2637 3 ปีที่แล้ว +2

    Salam sir, does this can apply to 21 ft span?

  • @amols9634
    @amols9634 3 ปีที่แล้ว

    L/20 for 19 feet span 285mm depth so safer side you have to take 230x 380

  • @byrappakaramaradi4070
    @byrappakaramaradi4070 2 ปีที่แล้ว

    What should be the height of building?

  • @paonamdineshmangang6179
    @paonamdineshmangang6179 3 ปีที่แล้ว

    Sir is it OK to put 4 Steel rod of 16mm on top and 4 on bottom of 17.5 feet long beam

  • @javedalibukhari2326
    @javedalibukhari2326 29 วันที่ผ่านมา

    1 thing missed 😊
    If the size of crank bar 19 fit what is the size of carnk position. What is the is the distribution size..
    It is important as well.

  • @defersonlyngdohmawlong708
    @defersonlyngdohmawlong708 3 ปีที่แล้ว

    G 1 G2 G3 means what? Does it mean 1floor 2floor

  • @phyohtetkoko929
    @phyohtetkoko929 2 ปีที่แล้ว

    Thanks For Teaching Sir

  • @Mithushahome
    @Mithushahome 3 ปีที่แล้ว

    Super bro

  • @namahshivay8978
    @namahshivay8978 ปีที่แล้ว

    Thanks 👍❣️

  • @moamar7585
    @moamar7585 2 ปีที่แล้ว

    what is the thickness of footings?

  • @khan52310
    @khan52310 2 ปีที่แล้ว

    If I have 24 feet span and other side is 26 feet span for G plus 1 story home only, please reply

  • @ayaan5633
    @ayaan5633 3 ปีที่แล้ว

    Can you do your future video measurements in feet and inches.?

  • @waluohopaulo2116
    @waluohopaulo2116 3 ปีที่แล้ว

    Well understood

  • @sridharsahoo489
    @sridharsahoo489 3 ปีที่แล้ว

    Sir u could not say top reiforcement which mm bar used in this video

  • @ningthoujamnewtonmeitei5137
    @ningthoujamnewtonmeitei5137 3 ปีที่แล้ว

    Sir can it apply in normal residential building

  • @akojuravisankar3492
    @akojuravisankar3492 2 ปีที่แล้ว

    Thank you for giving good information about construction building.

  • @premjitchakpram4201
    @premjitchakpram4201 3 ปีที่แล้ว +1

    How about if we made column size 12x12 for G+2 residential house with steel rod of four 16mm and four 12mm?

  • @kaungsettlinn1179
    @kaungsettlinn1179 4 หลายเดือนก่อน

    ACI code(Beam is. span× 0.75=beam depth)

  • @manjunathbc3655
    @manjunathbc3655 ปีที่แล้ว

    What should be size of beam and column and size of steel which is 7 meters and roof size and steel size G+3

  • @lakshmanang8316
    @lakshmanang8316 3 ปีที่แล้ว +1

    Need plinth beam design

  • @intkhabahmad453
    @intkhabahmad453 ปีที่แล้ว

    Steel volume should be 1-2% of RCC volume for beam. Calculate it

  • @aemisection4460
    @aemisection4460 2 ปีที่แล้ว

    please post a video for culvert reinforcement details and designs

  • @muruganmuthusamy9976
    @muruganmuthusamy9976 3 ปีที่แล้ว

    Fine

  • @chatpatgamingyt2707
    @chatpatgamingyt2707 2 ปีที่แล้ว +1

    What will be the size of footing for same building if soil bearing capacity is 70kn/m2?

    • @SandeepKumar-eg1kw
      @SandeepKumar-eg1kw ปีที่แล้ว

      It is good decision to choose deep foundation than shallow foundation if you cam to know soil is till 70kn of bearing

  • @nyantehemmanuel7089
    @nyantehemmanuel7089 9 หลายเดือนก่อน

    maximum span between columns

  • @UmeshSahu-di2ee
    @UmeshSahu-di2ee 2 ปีที่แล้ว

    Wow bhai....

  • @muhammadtahirmushtaq6300
    @muhammadtahirmushtaq6300 2 ปีที่แล้ว

    good mashallah

  • @lakshmanang8316
    @lakshmanang8316 3 ปีที่แล้ว

    I have one doubt ,
    In your previous video you say As per Indian standard min depth of beam is d/16 = 19/16= 1.2 ft but you say now 1 ft is enough . how !?

  • @kswvidioyoutube8816
    @kswvidioyoutube8816 3 ปีที่แล้ว

    Very nice explaination but not for the poor peaple it's too much and it will be very expensive less size column beam can biuld G+2

  • @salimmahmud1614
    @salimmahmud1614 2 ปีที่แล้ว

    Maa shah Allah

  • @himangshupatra5000
    @himangshupatra5000 3 ปีที่แล้ว +1

    SIR I HAVE 16 feet span G+1.stroy, i have provide beam ( 9 inch *12 inch ) , with 16 mm 2 bar, and 12 mm 1 bar at bottom, and 2 bar of 12 mm at top with 8mm stirrups @150mm c/c spacing, is it safe?? Also column size -(9"*15")

    • @ayaan5633
      @ayaan5633 3 ปีที่แล้ว

      absolutely save for G+1

    • @trishan2739
      @trishan2739 3 ปีที่แล้ว

      Can you explain that what is column and beam size with how many steel used with size
      Also length and width distance of each column

  • @logisticsh.n.a.a4136
    @logisticsh.n.a.a4136 3 ปีที่แล้ว

    Do pakistan and india have the same engineering principles for rcc construction .

    • @MehrbanRana
      @MehrbanRana 3 ปีที่แล้ว +1

      Dear All over the world is same principles.
      Even here in GCC countries are same principles.

    • @logisticsh.n.a.a4136
      @logisticsh.n.a.a4136 3 ปีที่แล้ว

      @@MehrbanRana thanks .

  • @engrijazali282
    @engrijazali282 ปีที่แล้ว

    if the span btween 2 column is 16ft...and the building is G+1+2 than explain size of column and beam...

  • @ramakantapradhan7932
    @ramakantapradhan7932 2 ปีที่แล้ว

    If column to column clear span 19', i want provide 6 nos 12mm bar in column and in beam 16mm 4nos bar, any problem plz solve it

  • @izharulhaq8435
    @izharulhaq8435 3 หลายเดือนก่อน

    And calculate the no. Of beams for 40 by 16 feet

  • @musahhamid5461
    @musahhamid5461 2 ปีที่แล้ว

    Pls I need picture of G+1 and G+2 story building

  • @awishhamza6368
    @awishhamza6368 7 หลายเดือนก่อน

    12x9'' beam isn't safe for 19-20 feet span in beam column structure. do stress analysis

  • @izharulhaq8435
    @izharulhaq8435 3 หลายเดือนก่อน

    Please answer my question

  • @DeepakKumar-oo9si
    @DeepakKumar-oo9si 2 ปีที่แล้ว

    18fit distance mi kon sa colum lgta hi

    • @mpannirselvam9512
      @mpannirselvam9512 2 ปีที่แล้ว

      36/60 what is the size of the pillar snd besm

  • @izharulhaq8435
    @izharulhaq8435 3 หลายเดือนก่อน

    No. Of beams used for 40 by 16 feet

  • @palashmatubber8496
    @palashmatubber8496 2 ปีที่แล้ว

    I love u sar

  • @nawalshrivastav6032
    @nawalshrivastav6032 ปีที่แล้ว

    Please hindi Language used.

  • @muhammadafzaal8670
    @muhammadafzaal8670 3 ปีที่แล้ว

    Agr urdu mai lecture daitai to aor acha hota......

  • @intkhabahmad453
    @intkhabahmad453 ปีที่แล้ว

    Your beam steel is not correct for 19 ft span... Moreover depth of beam is also very less for 19 ft... It should be minimum 19 ft... Rest of the calculation and suggestions are well.

  • @shanjaiks7583
    @shanjaiks7583 2 ปีที่แล้ว

    We are watching a religious programe . Inshallah

  • @muzammilkhan3054
    @muzammilkhan3054 2 ปีที่แล้ว

    Abhe main br 16 mm aygi

  • @idriveridesharing6493
    @idriveridesharing6493 2 ปีที่แล้ว

    It's all confusing

  • @252adeshpatade3
    @252adeshpatade3 2 ปีที่แล้ว

    Sir for 3 storey house
    6 no 12mm bars are sufficient or not
    Column size 9 * 15 "
    Please guide

  • @faritherwandy2126
    @faritherwandy2126 3 ปีที่แล้ว

    Not economical.