How to fix FLO problems (and other hot tub things)

แชร์
ฝัง
  • เผยแพร่เมื่อ 7 มิ.ย. 2019
  • The flow problem is happening because water is literally not flowing through the pipe. You probably see a "FLO" error code on your hot tub panel/display. It could be lots of different things, and I go through them in this video.
    I made this video for the next poor soul who is trying to learn everything there is to know about their hot tub. I have an "Adventure Hot Tub" by L.A. Spas. More importantly, the control board is a Gecko IN.XE-5-11-H4.0.
  • เกม

ความคิดเห็น • 21

  • @alanstendal2962
    @alanstendal2962 2 ปีที่แล้ว +3

    Thank you for taking the time to document your repair. I learned a lot from it.

  • @toddalexander2354
    @toddalexander2354 ปีที่แล้ว

    Thanks! I replaced the pack, but it was set for a spa with a circ. pump, and I didn't have one. I was able to program in the correct LL3 and it worked fine.

  • @walkjw44
    @walkjw44 3 ปีที่แล้ว +2

    Your video was very helpful. Holding down the pump button for 30 seconds then pressing the light button reset my spa, same control panel as you have. Thank you!

    • @rshillington
      @rshillington  3 ปีที่แล้ว

      Glad it helped! Thank you for letting me know.

  • @ChauLy703
    @ChauLy703 2 ปีที่แล้ว +1

    Thanks!! I have a diff control panel but I managed to change the LL code from 4 to 5, then set it back to 4. It fixed the heating issue I had.

    • @sethscofield
      @sethscofield 2 ปีที่แล้ว

      how did you change the LL code?

    • @rshillington
      @rshillington  ปีที่แล้ว

      @@sethscofield That's explained in this video. Basically hold the Pump 1 button down for 30 seconds.

  • @zeropointzeroband
    @zeropointzeroband 4 ปีที่แล้ว +2

    Thank You!

  • @patrickdubeau7131
    @patrickdubeau7131 2 ปีที่แล้ว

    Hi Ryan, Thanks for all your tips! I wonder if you can help? I had a tree that fell on my electrique lign and broke it...so since that event, my spa won't start! Like there's no électricity at all. I checked the fuses wich seems ok, all breakers on and the spa technicians are way expensive here in Québec. Do you have any tips?

    • @rshillington
      @rshillington  ปีที่แล้ว

      If there's no electricity at all (use a voltmeter to check the incoming lines) then you need to trace back the power line. There's likely an on/off breaker for your hot tub that's nearby. If there's power coming in but the control panel isn't registering anything, then you're probably best getting a new control board.

  • @charlesbakes2855
    @charlesbakes2855 2 ปีที่แล้ว +1

    Where pump one is plugged into the Orange connector. How do you remove the plug I cannot get it out of the Orange connector?

    • @rshillington
      @rshillington  ปีที่แล้ว

      Press down the tab at the top and wiggle it free.

  • @tomskerven5375
    @tomskerven5375 2 ปีที่แล้ว

    How do you know which LL program to run? I have changed my heater because of FLO code. Still same problem. Iam wondering if it's the LL program. I had it on 1. Pump 1 wouldn't turn off. I now have it on 4 now I can individually turn on and off each pump.

    • @rshillington
      @rshillington  ปีที่แล้ว

      There's a piece of paper that comes with your pump that explains what the different LL values are. Watch out! They're different even for the same model but different software versions they've loaded on the control board.

  • @titoforsythe1033
    @titoforsythe1033 3 ปีที่แล้ว

    Every once in awhile I go out to my tub and the jets that are suppose to always be running, pushing flow towards my filters, are not running. I turn off the power and they start up again. I read that they are alway suppose to be running. What would cause this, it’s not my filters I took them out and replaced them

    • @rshillington
      @rshillington  3 ปีที่แล้ว

      No motor should ever be running all the time, 24 hours a day. It's neither economical nor good for the motor.

  • @1Patient
    @1Patient 2 ปีที่แล้ว +2

    😃 9:51 Neighbor's Yard 😃

  • @kennedymiller3627
    @kennedymiller3627 ปีที่แล้ว

    Wrench symbol and 3 dotted lines flashing in right top corner??? Same control panel same hot tub

  • @katrinadillard7282
    @katrinadillard7282 3 ปีที่แล้ว

    I drained and cleaned my hot tub and everything worked fine. 2 days later I get the flo error and only one side of hot tub is working. Any suggestions?

    • @1Patient
      @1Patient 2 ปีที่แล้ว

      Replace Flo Sensor and remove all air from the system...bleed the system

    • @rshillington
      @rshillington  ปีที่แล้ว +1

      @@1Patient Yup. This! See the part about the red hoses that help bleed the system.