RELAY SETTINGS AND CO ORDINATION|PART 1_PHASE FAULT|ELECTRICAL TECHNOLOGY AND INDUSTRIAL PRACTICE

แชร์
ฝัง
  • เผยแพร่เมื่อ 22 ธ.ค. 2024

ความคิดเห็น • 97

  • @VineethKumar-o5d
    @VineethKumar-o5d หลายเดือนก่อน

    Very good illustration of relay co-ordination. Thanks for making this video.

  • @AminulIslam-we3kd
    @AminulIslam-we3kd 3 ปีที่แล้ว +1

    Excellent explanation of relays, the most important protection devices

  • @chintanvaria2238
    @chintanvaria2238 5 ปีที่แล้ว +4

    Excellent explanation. Very clear and to the point. 1st video I have ever watched for such clear explanation about relay coordination on TH-cam. Thank you. Keep making videos like this. 👍

  • @hassanmohammady9827
    @hassanmohammady9827 2 ปีที่แล้ว

    It was really helpful and precise. Thanks a lot

  • @amitagrawal7383
    @amitagrawal7383 3 ปีที่แล้ว

    Excellent brother. Good work. Thanks.

  • @selvammurugaiah2074
    @selvammurugaiah2074 3 ปีที่แล้ว

    Very informative.Good way of explanation.👍👏

  • @soulofcinder2351
    @soulofcinder2351 2 ปีที่แล้ว

    amazing work

  • @rajeshparmar6944
    @rajeshparmar6944 ปีที่แล้ว

    Sir thx.one small query @about not clear if dot represents inrush current in tht case LV curve shown below dot is means tht LV ACB or relay operating lower than inrush or inrushblocking is used pl.clarify. Regards.

  • @lovemybrothers727
    @lovemybrothers727 5 หลายเดือนก่อน

    Great effort friend

  • @fatjr.6287
    @fatjr.6287 4 ปีที่แล้ว

    Thank you for this, waiting for differential protection discussion from you sir.

  • @adityatiwari8044
    @adityatiwari8044 4 ปีที่แล้ว

    Sir I have an etap software but the basic problem is that in case of differential protection or in case of relay coordination it does not have an option of PS class CT please provide suggestions for this

  • @prashanthgaitonde3451
    @prashanthgaitonde3451 2 ปีที่แล้ว

    best video on youtube

  • @Vishal0106-m4p
    @Vishal0106-m4p 4 ปีที่แล้ว

    Is this co-ordination good for numerical relays, since they have inrush protection in them

  • @allthingsinonemedia3579
    @allthingsinonemedia3579 2 ปีที่แล้ว

    Sir, would you gave me more information parallel transformer protection coordination in double bus-bar
    and also about protecting only selected transformer from the parallel one.
    Thanks for willingness

  • @shrutikaushik8086
    @shrutikaushik8086 5 ปีที่แล้ว +2

    Superb explanation , thanks a lot sir , please make more and more technical videos like this , it helps a lot

  • @gustavomarcelo7250
    @gustavomarcelo7250 ปีที่แล้ว

    Sir.
    What if the system is supplied by 2 parallel Tx?

  • @Saharjunaid87
    @Saharjunaid87 4 ปีที่แล้ว

    Amazing video

  • @parthapratimnayak5791
    @parthapratimnayak5791 3 ปีที่แล้ว

    Sir pl a video for ht industrial meter showing 02 nos kvar reading in secure premier e3m051 .pl clarify two reading parameter

  • @md.nazmussadat3263
    @md.nazmussadat3263 5 ปีที่แล้ว

    Great initiative. Please Continue 👌👌👌

  • @imanrezaei8767
    @imanrezaei8767 4 ปีที่แล้ว

    Thanks alot. How can i coordination o/c relays when 2 motors exist on LV busbar

    • @electricaltechnologyandind5335
      @electricaltechnologyandind5335  4 ปีที่แล้ว

      Motors are instantaneous or 0.05 second delayed. With breaker operating time it will be around 0.11 sec. Now co ordinate accordingly

    • @imanrezaei8767
      @imanrezaei8767 4 ปีที่แล้ว

      Can i have your email sir due to sent network to you.i coordinated one network.could you please check it

  • @vineshvinod4603
    @vineshvinod4603 4 ปีที่แล้ว

    Good class....need class for machines

  • @sohrabalmajose4082
    @sohrabalmajose4082 ปีที่แล้ว

    thank you very much on your video

  • @sathaendi5224
    @sathaendi5224 4 ปีที่แล้ว

    Hai can you explain about Synchronoscop...

  • @BiswajitGhosh-gy1sc
    @BiswajitGhosh-gy1sc ปีที่แล้ว

    Please make a video of Battery sizing calculation by IEEE method.....

  • @rengaramanujan
    @rengaramanujan 5 ปีที่แล้ว

    Could u please clarify the difference between 51G and 64R and please explain if the relay actuated which breaker I.e either hv to be trip or LV to be tripped

  • @Infiniteknowledgenikhilrathod
    @Infiniteknowledgenikhilrathod 3 ปีที่แล้ว

    Which book due you referenced?

  • @josefinaiipolicarpio6647
    @josefinaiipolicarpio6647 4 ปีที่แล้ว

    I see youre blogspot what you mean by B/C AND I/C and PCC, what does it stands for?

  • @pemalhaden9268
    @pemalhaden9268 3 ปีที่แล้ว

    Please can you show us how to do baseline data calculation for over current relay coordination in transmission line using software digsilent.

  • @papakaaccountmummykaphone571
    @papakaaccountmummykaphone571 9 หลายเดือนก่อน

    Sir,Pl make video on different IEC Characteristic and relay coordination using them

  • @lokchand7962
    @lokchand7962 ปีที่แล้ว

    What is psm and tsm in numerical relay . i don't find that tipe of setting in numerical relay?

    • @electricaltechnologyandind5335
      @electricaltechnologyandind5335  ปีที่แล้ว

      PSM you need to calculate if you go by the hand calculation. Yes it is not an input setting to numerical relays. TsM is the time setting or time multiplier

    • @lokchand7962
      @lokchand7962 ปีที่แล้ว

      @@electricaltechnologyandind5335thank you very much for your response.😍😍

  • @anwarhussainansari13
    @anwarhussainansari13 3 ปีที่แล้ว

    Sir which book u follow ? Is this overcurrent protection scheme ?

  • @g.r.akashprbhagar9927
    @g.r.akashprbhagar9927 8 หลายเดือนก่อน

    Bro which software are you using for explaining this ?

  • @nishananda9838
    @nishananda9838 4 ปีที่แล้ว +1

    Thank you for vdo..
    I hv one question..How to select transformer withstand capacity?

    • @ShaileshKumarchetty
      @ShaileshKumarchetty 4 ปีที่แล้ว

      As IEC 60076 (Standard for Transformer) withstand time is 2 sec for through fault.

    • @electricaltechnologyandind5335
      @electricaltechnologyandind5335  4 ปีที่แล้ว +1

      A trafo shall be capable to withstand for two second with one end short circuited and rated voltage applied at the other end

    • @ShaileshKumarchetty
      @ShaileshKumarchetty 4 ปีที่แล้ว

      @@electricaltechnologyandind5335 good job, I liked your video. Quality content !

  • @jameslee7004
    @jameslee7004 3 ปีที่แล้ว

    Thank for your video. In the primary side, pickup current = 1.3x FLA, but secondary side, pickup current = 1.2 x FLA.. Is there any reason with two different value?

  • @khan_tanzeem0521
    @khan_tanzeem0521 4 ปีที่แล้ว

    Excellent explanation..how can I calculate relay 67 / 67N and 32 if my load is 6MW can you please explain....I am looking for manual calculation without using software...voltage 4.16kV..

  • @anwarhussainansari13
    @anwarhussainansari13 3 ปีที่แล้ว

    Phase fault is same as Overcurrent ?

  • @saurabhlangave3528
    @saurabhlangave3528 5 ปีที่แล้ว

    Sir can u please suggest book for relay coordination for numerical relay ,As well as what type of protection we should provide for different types of electrical equipment .

  • @Little_paaw
    @Little_paaw 5 ปีที่แล้ว

    Sir can you please make the video of how digital relay like schinder abb work? I have seen many time there is using logic gate how they help for working the relay?

  • @manmohandhir9117
    @manmohandhir9117 ปีที่แล้ว

    Setting of 50 hv1 should be higher than secondary short ckt. reflecting on the primary. Setting at lower level will affect coordination

  • @rezamagham4495
    @rezamagham4495 ปีที่แล้ว

    Perfect

  • @shamirdebnath7407
    @shamirdebnath7407 4 ปีที่แล้ว

    Good explanation but i have a question. when 2.5 MVA transfo switched on inrush current will flow. as 50(HV1) consider inrush, this will allow it. but 51( HV1) has lower limit of pick up current. Does this allow inrush current to flow?

    • @electricaltechnologyandind5335
      @electricaltechnologyandind5335  4 ปีที่แล้ว

      51 will pickup but won't trip because inrush will be decreasing in nature. So the relay operating time will increase. And before tripping the inrush will be ended

  • @adelino19701
    @adelino19701 4 ปีที่แล้ว

    My question is why in setting of 51(HV2) the short circuit fault current is considered?. I understand that ansi code 51 is for phase time overcurrent and ansi code 50 is instantaneous overcurrent. Therefore such short circuit fault current should be considered in setiing of 50 (HV1) and not 51(HV2)

  • @vineshvinod4603
    @vineshvinod4603 4 ปีที่แล้ว

    Great

  • @Moon3pell
    @Moon3pell 2 ปีที่แล้ว

    Very good presentation. But the question is why 51(HV2) does not have any instantaneous element 50(HV2)? and only 50(HV1) has instantaneous?

  • @parthapratimnayak5791
    @parthapratimnayak5791 3 ปีที่แล้ว

    Lt 3phase motor safety overload realy setting combination of thermal relay and electronics relay

  • @jimuelvillaoz4238
    @jimuelvillaoz4238 4 ปีที่แล้ว

    Hi Sir, May I please know where exactly I can find the relay time selection as you mentioned in this video? Can you please provide me the specific link? Many thanks!

    • @jimuelvillaoz4238
      @jimuelvillaoz4238 4 ปีที่แล้ว +1

      I am really hoping that you will notice my post the soonest and get a feed back on this. Many thanks!

    • @electricaltechnologyandind5335
      @electricaltechnologyandind5335  4 ปีที่แล้ว +1

      The relay timing I explained is my experience and some calculation regarding the fault withstand capability of bus bar, cables, transformer etc.

  • @pcselvam
    @pcselvam 4 ปีที่แล้ว

    Very nice explanation sir......what about unbalance current in one phase... current circulate line CT? Trip?

    • @electricaltechnologyandind5335
      @electricaltechnologyandind5335  4 ปีที่แล้ว +1

      If there is negetive sequence then you have to give elnegetive sequence relay, if earth fault then earth fault relay will trip

  • @jkj1459
    @jkj1459 4 ปีที่แล้ว

    THANKS YOU SO MUCH SIR , HOW WE DEDUCE PSM FORMULA

  • @jameslee7004
    @jameslee7004 3 ปีที่แล้ว

    Can you please show same topic using ETAP for next video if possible?

  • @syedhajamuyinudeensaiyadya2960
    @syedhajamuyinudeensaiyadya2960 3 ปีที่แล้ว

    👍👍👍

  • @97542729
    @97542729 ปีที่แล้ว

    What are difference relay cordnetion between 400/200/132/33 KV Substation to 33/11kv substation earth fault over current Numerical relay cordnetion please suggest me

  • @jayantkumardas1987
    @jayantkumardas1987 3 ปีที่แล้ว

    Thank you so much

  • @aliamoor1541
    @aliamoor1541 5 ปีที่แล้ว

    thank you sir : the equipements of electrical power system are transformer , medium voltage cable , bus bar and motor electric so we have different zones of protection in our electrical system and we must be provided by relays according to type of défaut electric my question is how to choose type of relay (50/51) and its calculations

    • @electricaltechnologyandind5335
      @electricaltechnologyandind5335  5 ปีที่แล้ว +1

      calculation of 50 and 51 is already there.. you can watch it

    • @aliamoor1541
      @aliamoor1541 5 ปีที่แล้ว

      Thanks a lot sir when we use IDMT relay or instantaneous relay or both in different zone of electrical system

  • @Liguritio
    @Liguritio 4 วันที่ผ่านมา

    Why no 50 HV2 function ?

  • @Nivupedia
    @Nivupedia 4 ปีที่แล้ว

    Superb illustration, can you make video on Fault current calculation?

    • @electricaltechnologyandind5335
      @electricaltechnologyandind5335  4 ปีที่แล้ว

      I will make. I am out of my home town. So dont have the set up. Hopefully from October end such videos will come

    • @Nivupedia
      @Nivupedia 4 ปีที่แล้ว

      @@electricaltechnologyandind5335 Great 👍

  • @prabhaamjmurali8379
    @prabhaamjmurali8379 4 ปีที่แล้ว +1

    Thanks for the video. Very clear explanation. Can you make video for directional over current with 2 sources??

  • @durangi3716
    @durangi3716 5 ปีที่แล้ว

    Thank you very much!

  • @shihabahmedalkatrani3050
    @shihabahmedalkatrani3050 5 ปีที่แล้ว

    Thank you very much

  • @surendranram4364
    @surendranram4364 4 ปีที่แล้ว

    at 9.25 seconds setting for 51LV you calculated sec. current without pf. why? then why restricted and differential relay is not part of coordination?

    • @electricaltechnologyandind5335
      @electricaltechnologyandind5335  4 ปีที่แล้ว

      Transformer is rated in kva. So how power factor will come in picture??? Restricted earth fault relay is instantaneous relay, special type of protection...

  • @ats3389
    @ats3389 5 ปีที่แล้ว

    Sir,A minor mistake is there in full load current calculation .. the values are correct but the formula is given like this Power/√3 /voltage....It should be like this Power/√3*voltage

    • @electricaltechnologyandind5335
      @electricaltechnologyandind5335  5 ปีที่แล้ว

      you are also wrong.... it is power/(√3*voltage).
      i hope you have understood the difference, and why the values have been correct....

    • @ats3389
      @ats3389 5 ปีที่แล้ว

      @@electricaltechnologyandind5335 yes sir i am also wrong. sorry

  • @shashankkumar7770
    @shashankkumar7770 4 ปีที่แล้ว

    Thanku sir..

  • @kiagengreksapati
    @kiagengreksapati 4 ปีที่แล้ว +1

    I offer to addmit translate or english subtitle on this video, that will be very helping.

  • @narayanaswamygunasekaran521
    @narayanaswamygunasekaran521 4 ปีที่แล้ว

    Font size may be increased not readable or video may be done in more close up position

  • @nduduzozondi8953
    @nduduzozondi8953 4 ปีที่แล้ว

    Thank you for this content. Can you please make a video on Mini substation, Kiosk and electrification

  • @bongbengsiong5545
    @bongbengsiong5545 5 ปีที่แล้ว +1

    sir, I love u

  • @anilchopra83
    @anilchopra83 4 ปีที่แล้ว

    thanks but audio quality not good

  • @ahmadrazarizvi7819
    @ahmadrazarizvi7819 3 หลายเดือนก่อน

    Noise issue

  • @pcselvam
    @pcselvam 4 ปีที่แล้ว

    Pl reply sir......

  • @Invisionmedibihar
    @Invisionmedibihar 3 ปีที่แล้ว

    sir can you explane in hindi

  • @dilipsahusahu680
    @dilipsahusahu680 5 ปีที่แล้ว

    Hindi

  • @albertos8809
    @albertos8809 4 ปีที่แล้ว

    Subtitles please I can't understand because of the accent